3 Phase Direct Online Starter DOL Wiring and Connections Explained

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 ต.ค. 2024

ความคิดเห็น • 35

  • @jonerasmus9399
    @jonerasmus9399 หลายเดือนก่อน

    A tip that helped me as an appreciate was : split the circuit into two parts . 1 part control circuit and 2nd part is the main .
    Knowing that simplifies the wiring a bit more .

  • @UnimportantAcc
    @UnimportantAcc ปีที่แล้ว +15

    I wouldn't worry too much about meticulously learning the DOL.
    In the am2 you are provided with a wiring diagram, so it is very easy to see where the link cable is missing from.

    • @GSHElectrical
      @GSHElectrical  ปีที่แล้ว +1

      Thanks for the feedback 👍🏻

    • @slelectricaleducation129
      @slelectricaleducation129 ปีที่แล้ว

      th-cam.com/video/KF3Va2yIUKM/w-d-xo.html

    • @sunshine3187
      @sunshine3187 ปีที่แล้ว +4

      My dol wiring diagram today went L3-L2-L1 from left to right. Not L1-L2-L3.

  • @Death88758
    @Death88758 9 หลายเดือนก่อน +2

    I WISH you would do a continuity test on this from a three phase board,there is no such thing on TH-cam😢

  • @seanmcneill8899
    @seanmcneill8899 ปีที่แล้ว

    Very informative video on dol motor control. Thanks lads.

  • @princejoseph1349
    @princejoseph1349 ปีที่แล้ว

    Thank you guys ,this is really helping

  • @baaagudubala1363
    @baaagudubala1363 ปีที่แล้ว +1

    You are simply the best

    • @GSHElectrical
      @GSHElectrical  ปีที่แล้ว

      Thanks for the support 👍🏻

  • @joeldwarika8356
    @joeldwarika8356 ปีที่แล้ว +1

    Perfect.🎉🎉🎉tnx guys😊

  • @montystelevision3238
    @montystelevision3238 ปีที่แล้ว +4

    Yes to when a GSH alert pops up.

    • @GSHElectrical
      @GSHElectrical  ปีที่แล้ว

      😁👍🏻

    • @montystelevision3238
      @montystelevision3238 ปีที่แล้ว

      @@GSHElectrical Gaz. I’ve had an interesting email regarding the pulling of service fuses

  • @EdijsUmanecs
    @EdijsUmanecs ปีที่แล้ว +1

    What is the benefit of using a contactor relay? Why not use 3 poles C32 Amper circuit breaker to use it as a switch for more simple schematics?

  • @adamwright5553
    @adamwright5553 ปีที่แล้ว +2

    Just wondering could you post a photo of the single phase and the three phase DOL starter circuit diagram, would be handy to have when on site. Great video 👌

    • @GSHElectrical
      @GSHElectrical  ปีที่แล้ว

      Motors, Starters, Controls, Remote Stop Start - Single and 3 Phase
      th-cam.com/play/PL2Ea5r9gxUUfv51Ld1UlNGR39rfFIExTU.html
      👍🏻

    • @slelectricaleducation129
      @slelectricaleducation129 ปีที่แล้ว

      th-cam.com/video/KF3Va2yIUKM/w-d-xo.html

  • @just_saw_dust
    @just_saw_dust ปีที่แล้ว

    What about VFD. Lots of new IE2 & IE3 3ph motors are designed to be run from single phase supplies via inverters.
    I'd like to see this covered as a video with some reference to the way this works and is wired up with starters and remote controls.

  • @arjansingh4971
    @arjansingh4971 11 หลายเดือนก่อน

    How would u go on testing this using R1/R2??

  • @laurabradley1857
    @laurabradley1857 ปีที่แล้ว +1

    Hi - I love your videos and they have been super helpful in helping me prepare for my AM2s, however I managed to fail my Fault Finding. I know there is some description of a fault where the motor is 'juddering' or something similar but I cant for the life of me remember what the fault was or how to test and then rectify it. Can you help me with this? Thank you!

    • @GSHElectrical
      @GSHElectrical  ปีที่แล้ว +1

      Hi thanks for the lovely message. If a 3 phase motor was juddering it has lost one of it phases. Remember all faults on AM2S are found either visually or by dead testing. All the best and keep me updated 👍🏻

    • @laurabradley1857
      @laurabradley1857 ปีที่แล้ว

      ​@@GSHElectrical I passed by the way!! Thank you! Loving life as a fully qualified spark now!

    • @abdulseaforth6930
      @abdulseaforth6930 ปีที่แล้ว

      @@GSHElectrical yes Gaz- I see. By losing one of the sizes, it’s out of balance so it won’t run so smoothly. It will make sense!

  • @laurabradley1857
    @laurabradley1857 ปีที่แล้ว

    Not specific to Motors but if the motor was turning the wrong way, this is the result of 2 phases being crossed... is this Polarity or is polarity only when the Neutral is involved? Would I just say crossed phases/conductors? I think the terminology I used was wrong last time & I don't want to make the same mistakes!

  • @toughshoe6408
    @toughshoe6408 8 หลายเดือนก่อน

    Do you install a single phase motor on 3 phase in your am2?

  • @benparsons5876
    @benparsons5876 2 ปีที่แล้ว +2

    Is there a connection from terminal 18 to 14?

    • @GSHElectrical
      @GSHElectrical  2 ปีที่แล้ว

      3 Phase Direct Online Starter DOL Wiring Diagram Connections Explained
      th-cam.com/video/mcXxhUaUb94/w-d-xo.html

  • @tylerarmitage1476
    @tylerarmitage1476 ปีที่แล้ว +1

    credit boys very helpful.

  • @seanpritchard2650
    @seanpritchard2650 ปีที่แล้ว

    How would you wire a 415v coil with a pressure switch

  • @brianhewitt8618
    @brianhewitt8618 ปีที่แล้ว +2

    👌

  • @ELECTRICLIFE4U
    @ELECTRICLIFE4U ปีที่แล้ว +1

    👍👍👍👍👍