Common Instrumentation Faults - 4-20 mA Loops

แชร์
ฝัง
  • เผยแพร่เมื่อ 5 มิ.ย. 2024
  • In this vide we are going to look at common instrumentation faults. As an Instrumentation technician a big part of your job is to look into and fix instrument faults. We are going to look at the 6 most common 4-20 mA loop fault types.
    The loop will be a standard Pressure / Temperature / Level or Flow Instrumentation. The loop will terminate into a PLC input card.
    Some of the loop issues will involve electrically issues such as high and low loop resistance, component failure, Calibration error.
    I will talk about some of the fault finding techniques that you can use out there in different industries on different instrumentation.
    ▶▶Check out some of the products I recommend on my website: www.instrumentationcontrol.in...
    ▶▶Check out brilliant T-shirts / Merch at my store: www.redbubble.com/people/rudd...
    ▶▶Check out my website for more articles on Instrumentation: www.instrumentationcontrol.in...

ความคิดเห็น • 33

  • @mareysaad6597
    @mareysaad6597 5 หลายเดือนก่อน +1

    Extraordinary explanation ❤❤

  • @chinokhalifa5537
    @chinokhalifa5537 2 ปีที่แล้ว +3

    🙏 thanks for being back and uploading

  • @leef2267
    @leef2267 2 ปีที่แล้ว +2

    Nice video, well covered in 7 mins! Glad to see you uploading again. Keep them coming :)!

    • @InstrumentationControl
      @InstrumentationControl  2 ปีที่แล้ว

      Thanks Lee. It has taken me a while to get back into it with one thing and another. Hoping to keep the videos more regular. Hope you are well mate?

    • @leef2267
      @leef2267 2 ปีที่แล้ว

      @@InstrumentationControl I saw that you had covid, hopefully you’ve recovered well! Yes I am all good thanks

  • @jeevan1912
    @jeevan1912 2 ปีที่แล้ว +2

    Your channel helps me out on a daily 👍🏽

  • @jurassicsparks5220
    @jurassicsparks5220 2 ปีที่แล้ว +2

    Nice work, Keep em coming 👍🏻

  • @garyverth4887
    @garyverth4887 2 ปีที่แล้ว +6

    I worked in a complex nickel/cobalt plant and using a milliamp clamp meter was more convenient. You can narrow it down fairly quick without disconnecting.
    For Level transmitters of radar or ultrasonic type, a power cycle or removal and cleaning usually remedied.
    For differential transmitters, check the lines are clear through bleeds, if not flush.
    Check operation by hand pumping to 50,100% in relation to the range in kPa etc.. if this is good likely a process issue.
    Using a laptop can be advantageous if possible in sub station rather than a communicator depending on the system you have.
    Always remember to have loops put into calibration before working as process interruptions can happen from you unexpectedly making the instrument read something.

    • @InstrumentationControl
      @InstrumentationControl  2 ปีที่แล้ว +1

      You make some great points here Gary. Having the control room operators put loops into manual is definitely a big one. Thanks for sharing your experience.

    • @HappyHermitt
      @HappyHermitt ปีที่แล้ว +2

      I've worked in the Telephone industry and a bit of access controls even. My hobby is electronics and circuits. I've always been interested in control systems and instrumentation.
      I wish I could go back a few decades and take a different fork in the road..

  • @noelfaithfulkari2857
    @noelfaithfulkari2857 2 ปีที่แล้ว +2

    Very fine knowledge. Thanks alot.

    • @InstrumentationControl
      @InstrumentationControl  2 ปีที่แล้ว

      Glad you enjoy!

    • @noelfaithfulkari2857
      @noelfaithfulkari2857 2 ปีที่แล้ว

      @@InstrumentationControl yes I did. Please I need your support, I'll going for instrumentation interview tomorrow. Any possible guide?

  • @williamcollett4726
    @williamcollett4726 2 ปีที่แล้ว +2

    I used to come across lots of faults on dip pipe level measurement systems, could you do a video on these please? Also just wondering if you ever experienced faults on effluent PH monitoring ?

    • @InstrumentationControl
      @InstrumentationControl  2 ปีที่แล้ว

      Dip pipe level measurements are a simple technology but can work great. Often the issues with these are installation related. I may do a video on them one day. In regards to PH monitoring , calibration errors can cause issues. As well as isolation of process mediums. Thanks for your comment William, nice fish!

  • @gelisiomario5977
    @gelisiomario5977 ปีที่แล้ว +2

    Gold 👌🏿

  • @jasonloveless1499
    @jasonloveless1499 ปีที่แล้ว +1

    Please add more videos mate or contact me directly! Really enjoyed everything you've done so far

    • @InstrumentationControl
      @InstrumentationControl  ปีที่แล้ว

      My email is on my about page if you want to contact me. Thanks for watching

  • @richardsarmiento0526
    @richardsarmiento0526 ปีที่แล้ว

    Hello.
    What will happen on digital display if the termination of wire interchanged on transmitter

  • @Nicofish2023
    @Nicofish2023 ปีที่แล้ว

    Please how to do loop check on a fisher valve fieldbus

  • @EricPham-gr8pg
    @EricPham-gr8pg หลายเดือนก่อน

    Which voltage regulator are reliable ?

  • @angshumandutta7072
    @angshumandutta7072 7 หลายเดือนก่อน

    Make a video on analyser, ph sensor and gas chromatography. It's complete working.

  • @ejchicas7289
    @ejchicas7289 ปีที่แล้ว

    Was wondering where you where at?

  • @user-so9gs1wv3f
    @user-so9gs1wv3f 2 ปีที่แล้ว +1

    Hello... I am a new instrument technician. Are there any technical tips that you can help me with? Thank you

    • @InstrumentationControl
      @InstrumentationControl  2 ปีที่แล้ว +2

      Hi there, it's a great career to be involved in. It depends on industry etc. My best tip would be to never stop learning.

    • @user-so9gs1wv3f
      @user-so9gs1wv3f 2 ปีที่แล้ว

      @@InstrumentationControl thanks a lot 🙏🙏

  • @EricPham-gr8pg
    @EricPham-gr8pg หลายเดือนก่อน

    Resistance change with heat that is why light control is much better but will public trust engineering in military that is the reason for using resistor in circuit

  • @michealplater9007
    @michealplater9007 ปีที่แล้ว

    Spending a lot of time, it's not an electrical issue. It does not work that way, in correct selection, it's turned off, it's has been in fault for weeks, the PLC code has changed overnight, etc. etc.

  • @johnjones5354
    @johnjones5354 หลายเดือนก่อน

    Operators never trust the instrument reading. That's why they are operators..