I have never seen these questions pop up in any of my industrial electrician/ instrumentation job interviews, except for how to measure 4-20mA and what is a TC, RTD. This is some pretty advanced stuff. The ones Ive always been asked are: 1.Explain 0-10V and 4-20mA and pros and cons. 2. What are the color of the leads of a Thermocouple? Which one is + and --? 3. Do you pour water into acid, or acid into water? 4. How do you terminate a shielded cable. Which side of the cable do you ground? 5. What does 3-15 mean? 6. Do you know what zero and span means? 7. How do ultrasonic sensor work? Theres a couple others that always come up. Theyre pretty basic.
What other questions can you think of that would probably come up. Any videos/literature that someone who has been out of the field for a while could use to brush up on instrumentation basics? Thanks
It's very good explication but there are many information at once sow if you dont mind i have a proposition what if you did mini vidéos ans focos on evry part at once thankyou
Hello Alb We have created series of video too. Please see below links. 1. th-cam.com/video/4lbKLuB-cRs/w-d-xo.html 2. th-cam.com/video/4lbKLuB-cRs/w-d-xo.html
Does anyone have any insight into what the physical field evaluation and written evaluation would entail for an E&I Apprentice position? I passed the EEI MASS test and have these coming up. Thanks
Hi Please check the HART videos on our channel, we have videos on the requested topic Let me know if you want us to provide the link in the comment section
I agree. I would think bypass closure would be last. If you open the HP side first with the bypass closed the transmitter would see a very large pressure differential. Example: if the transmitter was taken out of service or replaced on a 450lb steam flow system and you opened the HP side the DPT would see a 450 lb differential. Often times steam flow transmitters are calibrated 0 to 100 inches of water using orface plates so damage could be a real possibility.
Why HP & LP tapping is done at 45 degree in process line for FIT Where K type TC is mostly used Explain transfer of signal from DCS to control valve How to calibrate interface level transmitter. What is actually marshalling cabinet
HP & LP Tapping is done at 45 degree in process line to avoid any entrapped gases & to avoid any pipe dirt particles in pipe lines Type K is commonly used in nuclear applications because of its relative radiation hardness. DCS sends 4-20mA signal to I/P converter. I/P converter converts 4-20mA signal into 3-15 psi signal. Then 3-15 psi signal goes to control valve to control the flow. I have made one video on Interface Level Measurement. Please see below link. th-cam.com/video/Z9S2mgVM3FU/w-d-xo.html The marshalling cabinet acts as an interface between the system cabinet and field junction boxes. The main cables are laid from the field junction boxes to the marshalling cabinet. The prefab cables from the system cabinet IO cards are also terminated in the marshalling cabinet.
@@InstrumentCalibration Guided wave radar type interface level transmitter calibration, what will be zero and 100? Working principle of ESDV and types?
I have never seen these questions pop up in any of my industrial electrician/ instrumentation job interviews, except for how to measure 4-20mA and what is a TC, RTD. This is some pretty advanced stuff.
The ones Ive always been asked are:
1.Explain 0-10V and 4-20mA and pros and cons.
2. What are the color of the leads of a Thermocouple? Which one is + and --?
3. Do you pour water into acid, or acid into water?
4. How do you terminate a shielded cable. Which side of the cable do you ground?
5. What does 3-15 mean?
6. Do you know what zero and span means?
7. How do ultrasonic sensor work?
Theres a couple others that always come up. Theyre pretty basic.
Hello
Thanks for your valuable feedback on this video
Good Comment.
Do you have the answers for those questions?
We do@@MR-nl8xr
What other questions can you think of that would probably come up. Any videos/literature that someone who has been out of the field for a while could use to brush up on instrumentation basics? Thanks
Hi @@imayleakount9610
We have made a decent chunk of videos on HART, CONTROL VALVES, and basic instrumentation interviews. Kindly check those :)
Very useful video
Glad you liked it
Thank you very much. The Q&A is simple to understand and on point . This has helped me a lot .
Thank you. I really appreciate your comment
exelent, GOD BLESS
Thank you sir
Very nice
Thanks Rajesh for watching this video
It’s good one
Thank you
transmitter mounting for steam service .picture equlising valave position check once.
Exallent
Glad you liked it
Excellent❤
Thank you
add questions on Cold Junction compensation?
exilent 👍
Awesome
Thanks for the information
Thank you
you are welcome
Diagrams 5:24 and 5:37 are backwards, if you are showing them in "gravity" fashion.
this video is vwry helpful for interview
Thank you
good😍
Thanks!!
NicE
Thank you
It's very good explication but there are many information at once sow if you dont mind i have a proposition what if you did mini vidéos ans focos on evry part at once thankyou
Hello Alb
We have created series of video too. Please see below links.
1. th-cam.com/video/4lbKLuB-cRs/w-d-xo.html
2. th-cam.com/video/4lbKLuB-cRs/w-d-xo.html
Does anyone have any insight into what the physical field evaluation and written evaluation would entail for an E&I Apprentice position? I passed the EEI MASS test and have these coming up. Thanks
Thank you for the video. Help me send me a video on analog scaling in PLCs
We will send it shortly
Fantastic
Sr i am instrument technician can u tell.me which course i do for furture carrier growth.
Hello Beats
Have you done engineering in Instrumentation and Control?
@@InstrumentCalibration sr I complete.diploma.electeonics and communication and 2 years exp.in instrument and 5+years exp.in electronic
Please make a clear video of AI AO DI DO signal connections from field to dcs
Hello Kiran
I will make clear video on this topic soon.
nice
Supper
Can u explain about working of by pass valves
Hi
Thanks for the comment.
Our tech team is working on this content
Good day, pls I need a video on CALIBRATING TRANSMITTERS USING HART COMMUNICATOR
Hi
Please check the HART videos on our channel, we have videos on the requested topic
Let me know if you want us to provide the link in the comment section
Thank you, almost all important questions are covered. Please do more videos on interview QA
Hello Kiran
Thanks for your comment. I will post more videos on interview questions and answers in future.
How to connect hart communicator to a transmitter
Thanks
Appreciate the feedback
Not Seedback but Seeback effect, you bet!
😍
VIDEO is super nice explain but video is high
I need psychometric test
9:14
Why are we using 4-20mA and not 0-20mA?
Commissioning a DPT is wrong , for some meters this procedure would destroy them straight away.
I agree. I would think bypass closure would be last. If you open the HP side first with the bypass closed the transmitter would see a very large pressure differential. Example: if the transmitter was taken out of service or replaced on a 450lb steam flow system and you opened the HP side the DPT would see a 450 lb differential. Often times steam flow transmitters are calibrated 0 to 100 inches of water using orface plates so damage could be a real possibility.
@@jackfeak2364The steps mentioned in the video is first open EQ and then only HP. Then why do say it is the opposite.
I'm interested in learning about instrumentation and control
What is the easiest way to learn instrumentation
Hello Alwell
You can start with our videos. If you watch all our video, you will definitely get some basic knowledge about I & C.
Search Practical Instrumentation
Channel
Loto explain
Loto-logout tagout
Why HP & LP tapping is done at 45 degree in process line for FIT
Where K type TC is mostly used
Explain transfer of signal from DCS to control valve
How to calibrate interface level transmitter.
What is actually marshalling cabinet
HP & LP Tapping is done at 45 degree in process line to avoid any entrapped gases & to avoid any pipe dirt particles in pipe lines
Type K is commonly used in nuclear applications because of its relative radiation hardness.
DCS sends 4-20mA signal to I/P converter. I/P converter converts 4-20mA signal into 3-15 psi signal. Then 3-15 psi signal goes to control valve to control the flow.
I have made one video on Interface Level Measurement.
Please see below link.
th-cam.com/video/Z9S2mgVM3FU/w-d-xo.html
The marshalling cabinet acts as an interface between the system cabinet and field junction boxes. The main cables are laid from the field junction boxes to the marshalling cabinet. The prefab cables from the system cabinet IO cards are also terminated in the marshalling cabinet.
@@InstrumentCalibration Guided wave radar type interface level transmitter calibration, what will be zero and 100?
Working principle of ESDV and types?
@@InstrumentCalibration When FIT is showing zero what will be position of FCV fully open or close.
@sushildurafe9037 You're like, so smart bro.
@@InstrumentCalibration
Excellent ❤