Testing and Troubleshooting 4-20 mA Control Loops Presented by Fluke and Transcat

แชร์
ฝัง
  • เผยแพร่เมื่อ 19 มิ.ย. 2019
  • This webinar will explore:
    -What a control loop is and how it works.
    -The most common culprits that can negatively impact the performance of a loop - and how to avoid them.
    -Different methodologies and tools to calibrate and troubleshoot 4 to 20 mA control loops.
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 18

  • @JaykeSapalaran-iq3qs
    @JaykeSapalaran-iq3qs ปีที่แล้ว +1

    Great video tutorial ❤ thank you for sharing your knowledge ♥️🇵🇭

  • @anthonyderkyeosei9105
    @anthonyderkyeosei9105 2 ปีที่แล้ว +1

    I love this tutorial because I have ambition to become a great instrumentation technician

  • @llpqazz
    @llpqazz 4 ปีที่แล้ว +2

    Thanks for this presentation.... very useful for remembering 4-20mA troubleshooting steps in field.

  • @SSteelePA1
    @SSteelePA1 3 ปีที่แล้ว

    Thanks for this presentation. Good explanations.

  • @jamesamadi9357
    @jamesamadi9357 2 ปีที่แล้ว

    Detailed explanation, Thanks.

  • @ianpierce7366
    @ianpierce7366 2 ปีที่แล้ว

    very Helpful video!!! Thank you!

  • @juanbr1411
    @juanbr1411 3 ปีที่แล้ว

    Muy buena explicación .

  • @qribhyat7191
    @qribhyat7191 ปีที่แล้ว

    gorduyum en genis ve en etrafli izahdir

  • @walbersoto
    @walbersoto 5 หลายเดือนก่อน

    thanks for the webinar, Could any one please tell me if there is a video where explain how to configure the interface-it software with dry block 9103 or 9009?

  • @mangeshghaware5932
    @mangeshghaware5932 2 ปีที่แล้ว

    I have made the 4-20 mA input & output isolator device.
    when i connect it to any instruments other than PLC then output shows right reading of the current given by my device.
    But when i connect the device to PLC there is slight change in reading on PLC
    e.g if i transmit 4mA to the PLC then PLC shows 4.09 mA.
    What will be the problem need to be corrected in my device to work with PLC also

  • @isaiahmalungane4318
    @isaiahmalungane4318 4 ปีที่แล้ว

    Good Presentation indeed.Very helpful.
    Here i have a problem , the RTD is reading constant value, even if temperature changes. I replace the puk, still the same problem, I replaced the probe, again the problem persists, now I'm simulating 4-20 ma from the line back to PLC, when I give 4 ma and measure ma in series with the fluke to the transmitter I'm getting 27 ma. What could be wrong or problem?

    • @frankperez1626
      @frankperez1626 4 หลายเดือนก่อน

      Did you find out the root of problem? seems to be that a noisy loop or some source of voltage higher than usual is keeping that current above range

  • @williamhudson3418
    @williamhudson3418 2 ปีที่แล้ว +1

    is there a way i can get this as a print out

  • @salemrachdi8704
    @salemrachdi8704 ปีที่แล้ว

    Thanks for this wwebinar. Can get this presentation PDF file?

  • @shamanking5195
    @shamanking5195 2 ปีที่แล้ว

    some times the 4 to 20 ma input in some devices is not isolated and not all manufactures give you the information
    How can I test if the input to a device is not isolated ???
    is there a test to confirm the input is not isolated ???
    Thanks.

  • @josua_htp