yup!!!!!thank you so much for the confirmation of the check valve. The parts house ACTUALLY had a note, if your switch leaks continuously after shutting off, do not replace this switch!!! Replace or clean the check valve on the tank...your video confirmed the real issue!!! I was one who was saved from replacing the switch unnecessarily. thank you AGAIN. :)
Exactly. Before looking at this video I replaced the pressure switch. With no luck. I watched this and purchased a new check valve. And then everything was fixed. Thanks for the video as I did exactly what you said replacing the pressure switch for nothing. Thanks again!!
Thanks for the vid solved my problem. Early 80s Sears twin 2hp. The unit was apart for a while and some crud got in the check valve. I was happy to find it was serviceable, cleaned it out all good.
Great video! I had a leaking pressure switch, cleaned up the check valve of some corrosion and problem solved. 10 minutes of effort got me up and running again. Thanks for posting!
Sure helped me out. Unloader leaked on old pressure switch and did the same on new switch. Had no idea about this other component. Thanks loads.👍🙏. Yes! I had one of the check valves that can be easily opened. Rubber plug was off center. Fixed. Thanks again.
I have a question, btw, I liked and subscribed because you are very knowledgeable about something I need help with. Well, here goes, I added a series of copper lines (and a water separator just before the tank) in a grid on the wall for cooling, about 70 feet in between the compressor head and the tank to get rid of all the water. When I did, the line isn't letting the check close until all that air in that line empties. The 70 ft. of copper line takes about 3 minutes to bleed out thus wasting a fair amount of air. Is there anyway to fix this and is this doing any harm to my compressor? It did get rid of almost all of the water out of the tank, btw.
Can a load genie be replaced with a conventional check valve if I replace the switch with one that has the 1/4" unloader nipple on it? My old Speedaire doesn't even have a switch. It just plugs in and goes. I like it because it's a quiet oil pump type so I'm hoping to save it. The noise coming off the load genie sounds like a blown rod bearing on a car.
Had a bad check value so i replaced it. Now the compressor pumps up to 125lbs, then over a 3 or 4 hour period it leaks back to 110lbs. Then it stays there. I was wondering if i took it apart and stretched the new spring a little would it help? Please help if you can
My pressure switch leaks air when it's shut off until the tank empties... I replaced the check valve tonight with an oem valve and it did NOT fix the issue... Any help?
What I am seeing is, my exhaust valve is leaking when the compressor starts up. So the whole time it's running, the exhaust valve is leaking. But when it shuts off, the exhaust valve stops leaking and everything works as normal. What would this be?
yup!!!!!thank you so much for the confirmation of the check valve. The parts house ACTUALLY had a note, if your switch leaks continuously after shutting off, do not replace this switch!!! Replace or clean the check valve on the tank...your video confirmed the real issue!!! I was one who was saved from replacing the switch unnecessarily. thank you AGAIN. :)
Exactly. Before looking at this video I replaced the pressure switch. With no luck. I watched this and purchased a new check valve. And then everything was fixed. Thanks for the video as I did exactly what you said replacing the pressure switch for nothing. Thanks again!!
Thanks for the vid solved my problem. Early 80s Sears twin 2hp. The unit was apart for a while and some crud got in the check valve. I was happy to find it was serviceable, cleaned it out all good.
Great video! I had a leaking pressure switch, cleaned up the check valve of some corrosion and problem solved. 10 minutes of effort got me up and running again. Thanks for posting!
Sure helped me out. Unloader leaked on old pressure switch and did the same on new switch. Had no idea about this other component. Thanks loads.👍🙏. Yes! I had one of the check valves that can be easily opened. Rubber plug was off center. Fixed. Thanks again.
Could be weak spring
Very good video and SO informative. Exactly what I was looking for.
fantastic video!!!! i was so close to buying a new switch until i saw your video. Ill be buying my stuff from you guys from now on! tyvm
Excellent. Answered all my questions about what is wrong.
I have a question, btw, I liked and subscribed because you are very knowledgeable about something I need help with. Well, here goes, I added a series of copper lines (and a water separator just before the tank) in a grid on the wall for cooling, about 70 feet in between the compressor head and the tank to get rid of all the water. When I did, the line isn't letting the check close until all that air in that line empties. The 70 ft. of copper line takes about 3 minutes to bleed out thus wasting a fair amount of air. Is there anyway to fix this and is this doing any harm to my compressor? It did get rid of almost all of the water out of the tank, btw.
Thank you, very educational.
Excellent video and explanations.
thank you. can a shut off ball valve be doing work of a air check valve. meaning, can the earlier one replace the check valve pl.
Can a load genie be replaced with a conventional check valve if I replace the switch with one that has the 1/4" unloader nipple on it? My old Speedaire doesn't even have a switch. It just plugs in and goes. I like it because it's a quiet oil pump type so I'm hoping to save it. The noise coming off the load genie sounds like a blown rod bearing on a car.
Thanks God very much sir for sharing your knowledge.
This is a amazing freaking video!!
Thanks for such an informative video.
All hail the Algorithm
Had a bad check value so i replaced it. Now the compressor pumps up to 125lbs, then over a 3 or 4 hour period it leaks back to 110lbs. Then it stays there.
I was wondering if i took it apart and stretched the new spring a little would it help?
Please help if you can
TY for this (very useful) video!
Very pro and knowlegable.
Can a bad check valve cause it to not build any pressure in the tank
yes
Can I put a filter before my check valve? It keeps getting crap in it
My pressure switch leaks air when it's shut off until the tank empties... I replaced the check valve tonight with an oem valve and it did NOT fix the issue... Any help?
Great.
How to order the check Valve
There's are leaking into the oil when I pull the dipstick out air comes rushing out head gasket or check valve
What I am seeing is, my exhaust valve is leaking when the compressor starts up. So the whole time it's running, the exhaust valve is leaking. But when it shuts off, the exhaust valve stops leaking and everything works as normal. What would this be?
Can you adjust the check valve
It’s a one way valve
Thank you so much. Very helpful.
idk why but measuring thread size is more complicated than it needs to be
I'm looking for a replacement compressor for my big tank. I got it at Lowe's 25 years ago.
Me too, 10 hp, twin cylinders
@@stephenbemish5358 Just get online and order the rebel parts and rebuild it way cheaper