  • @JM-yx1lm
    @JM-yx1lm 3 ปีที่แล้ว +4

    Man that's awesome, I just got the same inverter but the 6k version. It's awesome. My stocker for the warranty void was only attached to the cover metal so I opened up the unit and looked around and it's pretty simple inside and very good construction and that transformer is huge!!!

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว +3

      Yes and they sell replacement components for you to have on hand in case of issues. That is a good practice

    • @ramondasta5560
      @ramondasta5560 2 ปีที่แล้ว +1

      @@nubiandavis2610 Do they have any options or ideas for the reduction of fan or fans noisy level?

    • @nubiandavis2610
      @nubiandavis2610  2 ปีที่แล้ว +1

      @@ramondasta5560 no. It's a noisy beast.

    • @davidlong1182
      @davidlong1182 2 ปีที่แล้ว

      Own the same as you on 3 eg4 48v batteries. Flawless communication. Plug n play. Luv that it runs the dryer

  • @texasoffgridguy8749
    @texasoffgridguy8749 3 ปีที่แล้ว +6

    Nice setup I just purchased one for a secondary system and you’re going to make it with 65kwh storage, you’re ready for when the grid fails !!!

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว +2

      Exactly!!! It will fail, it is a matter of time

    • @daniellarno7477
      @daniellarno7477 3 ปีที่แล้ว +1

      To be comfortable if the grid fails. You want around 100kwh of storage .. that would run everything and be sweet as till morning or when your gen kicks in

    • @texasoffgridguy8749
      @texasoffgridguy8749 3 ปีที่แล้ว +3

      @@daniellarno7477 that’s true but That’s only if you running a ac unit without a ac 40kwh to 60kwh is just fine it’s been cloudy and raining in Texas but My system still charge and be at 100% everyday

    • @alexisgueits7684
      @alexisgueits7684 2 ปีที่แล้ว

      I am interested in adding this as a secondary system as well with a 11.3kwh BigBattery. I have so many questions... 🤦🏽‍♂️

  • @carsonlurbanwindandsolar3437
    @carsonlurbanwindandsolar3437 3 ปีที่แล้ว +4

    Man you are ready nice system I like that inverter I have been hearing a lot of good things about them 👍.

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      Yes thank you! I am very impressed with the Growatt inverter so far. Yesterday it ran a 9kw load for 5 hours straight. The battery bank couldn't keep up so I switched to Grid but it did not even hiccup once.

  • @danielkeirsteadsr6939
    @danielkeirsteadsr6939 3 ปีที่แล้ว +2

    HI Tony . The grid is Looking good. 12k awesome.

  • @chrisfryer3118
    @chrisfryer3118 3 ปีที่แล้ว +2

    That's looks like a nice step up, I'm envious.

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      Thanks Chris!! It doesn't take much to put something together. First step, panels.

  • @One.--
    @One.-- 3 ปีที่แล้ว +2

    Growatt are great. I have the 12KW, surge capacity 36,000KW off grid & it does exactly what I wanted it for. That is to run my 4 ton A/C unit 24 KWH Li Ion baterry bank & the load is only 50%.
    During the day it runs like a charm. But at night without the panels I do have switch it back to the grid. I will increase the battery bank. My A/C unit is completely removed from my 6.5KW microinveter system grid tie. Seeing the electric meter running backward for the most part is the best thing any home owner can be please with. Plus saving the world do your part.This Is its little brother which would work too, I went with big brother because it's better off not having a full load on it all the time. Only issue need to hook up external BMS not able to use the. Growth functions to input settings locked in manufactures
    Watch "12KW Growatt Offgrid inverter is a straight beast!!!" on TH-cam
    th-cam.com/video/pp-DaMXd158/w-d-xo.html

    • @TheGuruStud
      @TheGuruStud 2 ปีที่แล้ว

      Solar panels and batts create such highly toxic crap in production, then they can't be recycled (you're being lied to about batteries, no one's gonna recycle).
      You're only polluting.

    • @alexisgueits7684
      @alexisgueits7684 2 ปีที่แล้ว

      Do you have a microinverter solar system and you added this one to a 2nd solar array? I have a few questions for you if that is the case... Thanks

  • @kojakdurham
    @kojakdurham 2 ปีที่แล้ว

    That's really sweet! I have been looking at this unit as well. I was initially thinking about two of the 120v 5-6kw systems running together to get the 240v, but this is much simpler.

  • @soulkeeper514
    @soulkeeper514 3 ปีที่แล้ว +1

    i seems that Growatts is now getting on board with Sigineer inverter that is a Sigineer inverter rebrand ,same with Aims, SunGold and others , no surprise is so powerful.

  • @markmeyer9571
    @markmeyer9571 3 ปีที่แล้ว +1

    Awesome setup 💪💪 Thank you for the Video!

  • @Gallardo6669
    @Gallardo6669 3 ปีที่แล้ว +2

    Please, would you be so nice and make a video about all the possible settings and the initial setup??
    That would be very much appreciated!!🤓

  • @dalek.6171
    @dalek.6171 3 ปีที่แล้ว +1

    Awesome Nubian. Like to try the 6K-8K Growatt. Running 4 EPEVERs now with 24 KWHs Lifepo4 & 4860 Watts Solar. Doing surprisingly well for North Indiana.

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว +1

      Definitely give them a shot, they work very well. I am about to get a couple of the 240v 5kw units and use them with a transformer. 450v input voltage is pretty damn amazing. That is like a string of 10-12 panels depending on wattage.

  • @OurBlackCatCottage
    @OurBlackCatCottage 3 ปีที่แล้ว +1

    Very impressive setup!

  • @alexnoff6284
    @alexnoff6284 2 ปีที่แล้ว +1

    Hi Awesome setup. Two questions: Did you bond ground and neutral in the subpanel witch inverter feeds? Did you run a neutral from main panel to subpanel to have a common neutral?

    • @nubiandavis2610
      @nubiandavis2610  2 ปีที่แล้ว

      I have a neutral feed from main box to all subsequent subs down the chain. I also bond ground and neutral in the subs. Works without issue

  • @RobertBurns-ji7ip
    @RobertBurns-ji7ip 2 ปีที่แล้ว +2

    Nubian, will the display show the output of both PV1 and PV2 separately?

    • @nubiandavis2610
      @nubiandavis2610  2 ปีที่แล้ว +1

      The app certainly does. I don't recall if the main display does

    • @josesantiagosanchezsanchez3154
      @josesantiagosanchezsanchez3154 ปีที่แล้ว

      ​@@nubiandavis2610 because my internet is 2.5 and 5g i can't install the wifi dongle...And see if my PV2 is working correctly PV1 i know it does because the wires feel warn and the voltage drops a little but the PV2 is cold don't know if the mppt behavior uses only PV1 if it sufficient... thinking of turning off PV1 tomorrow see how it behaves...

  • @carlosd.9158
    @carlosd.9158 2 ปีที่แล้ว +1

    Any videos on how you tied it into your main panel

    • @nubiandavis2610
      @nubiandavis2610  2 ปีที่แล้ว

      There's a million of those out there really. The unit outputs 240v on two hot 120v legs and a neutral. Path that output into any service panel dual breaker 60a or higher. Run a ground also. You are set.

  • @Ryegraw
    @Ryegraw 3 ปีที่แล้ว +1

    Wow! Super kool. I have a baby system to this

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      Babies must grow up!! Keep adding to it and you will see... it is an addiction! Thank you for visiting and I hope you subscribe

  • @henrymcfarlane9284
    @henrymcfarlane9284 ปีที่แล้ว

    Can you share your setting program (01-28) configuration of the 12kw inverter?

  • @williamseptember640
    @williamseptember640 2 ปีที่แล้ว +1

    Hey, how is the programming set up… to run of solar alone, irrespective of battery levels?

    • @nubiandavis2610
      @nubiandavis2610  2 ปีที่แล้ว

      I am hoping I can get the EG4 units to see the Seplos BMS units via Pylontech emulation. I'll know in s couple of days

  • @vt20247
    @vt20247 3 ปีที่แล้ว +2

    Hi Nubian!
    Nice setup. I do have a question about the display. I saw it has 240v output while you were scrolling through the display.
    Do you have any video or can you provide more details, please? I am curious about the Growatt configuration/setup and how you got setup? I am curious to know if the Growatt output is setup to 240v then how do we use 120v appliance!

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      This unit is a split phase unit for use in the USA. 2 120v got lines and a neutral just as your grid feed does. It can power both 240v and 120v loads.

  • @BEISES_SOLARTECH
    @BEISES_SOLARTECH ปีที่แล้ว +1

    If the GroWatt Pv input is 7000w can I really get the 12kw rated out put from the inverter?

    • @johnettipio
      @johnettipio 4 หลายเดือนก่อน +1

      Yes but, you will drain your battery faster than it is being charged.

  • @efficientmewithsomto8020
    @efficientmewithsomto8020 2 ปีที่แล้ว

    Nice setup man

  • @WiSeNhEiMeR-1369
    @WiSeNhEiMeR-1369 2 ปีที่แล้ว

    HOWdy N-D, ...
    Thanks
    COOP
    the WiSeNhEiMeR from Richmond, INDIANA
    ...

  • @vp112358
    @vp112358 ปีที่แล้ว

    Any updates

  • @ihsanhanif3343
    @ihsanhanif3343 ปีที่แล้ว

    What if you only have 1 phase, how do you attach the AC input in cable?

  • @juannistorres393
    @juannistorres393 ปีที่แล้ว

    How many solar panels you have my friend

  • @miabellasalonandmedicalspa2822
    @miabellasalonandmedicalspa2822 2 ปีที่แล้ว +1

    Did you connect your AC output to a breaker box/panel? If you did, are the neutral & ground terminals connected to box?

    • @Mkiepert
      @Mkiepert 2 ปีที่แล้ว

      This is the same question I have. Did you get an answer to this?
      Thanks

    • @miabellasalonandmedicalspa2822
      @miabellasalonandmedicalspa2822 2 ปีที่แล้ว +1

      @@Mkiepert diysolarforum discussion suggests : The output panel would be a separate panel.
      The main panel ONLY provides 240V to inverter, no neutral bond. So the only bond is the ground to the inverter.
      As long as you do not EVER tie the output to the grid, it should be fine. Dont connect output panel's neutral to main because that neutral may output and feed to the grid. So you would have separate panel for output instead of subpanel.

  • @mikemjm748
    @mikemjm748 ปีที่แล้ว +1

    Why is mine only have an arrow line off the negative on display and yours is off the positive on the batt looking icon on the display what does it mean

  • @davidmena4702
    @davidmena4702 3 ปีที่แล้ว

    I have the 6000w growatt with 4 battery 24v 200 in total 400ah it running my two heater and ac unit 36000 btu each one i pay no heate or electric bill for ac they're work perfect

  • @bimmers323ci
    @bimmers323ci ปีที่แล้ว

    Hi can this growatt do AC coupling

  • @richardTEPUZ
    @richardTEPUZ ปีที่แล้ว

    Awesome video

  • @AveRage_Joe
    @AveRage_Joe 3 ปีที่แล้ว +1

    LOVE IT!!!!!

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      Hsy!! Glad you made it over!!! How's your unit doing?

    • @BEISES_SOLARTECH
      @BEISES_SOLARTECH ปีที่แล้ว

      If the GroWatt Pv input is 7000w can I really get the 12kw rated out put from the inverter?

    • @AveRage_Joe
      @AveRage_Joe ปีที่แล้ว

      @@nubiandavis2610 Wow not sure how I missed your comment. My inverter is doin great and doin some WORK!😆

    • @AveRage_Joe
      @AveRage_Joe ปีที่แล้ว

      @@BEISES_SOLARTECH I havent run mine straight at 12kw for long, for me its more in spikes. I could probly give it a go tho!

  • @sk8erboi602
    @sk8erboi602 2 ปีที่แล้ว

    So it looks like you stacked a second charge controller to expand past 7kw PV input.

  • @nicklupien2322
    @nicklupien2322 3 ปีที่แล้ว +1

    Very nice demonstration, one thing that struck me was the wire gauge outputs for the 12kw AC load. At 6gauge, it accounts for the 50A draw, but does not give any room for the 36KW surge. Im hoping to fit 4ga wires on this. Do you suppose that would work?

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว +1

      Remember how energy flows. Even at #6 wire THHN lets say - that will allow energy flow to75 amp indefinitely. A surge of 36000 will theoretically never happen and can be protected against with fuses, etc. 12000w is a VERY large load and while possible, most unlikely. I had to work hard just to get a 12000w load running to test my inverter. #6 wire will run that surge for 10 minutes before heating up to dangerous levels. Your BMS will sense that load and properly manage disconnection if it gets out of spec way before that wire burns. Make sure you are using good BMS systems - I use Daly and they have been very effective to date.

    • @jamesshomesolarmore2223
      @jamesshomesolarmore2223 2 ปีที่แล้ว

      I agree with both of you. I would probably put in a heavier wire for just in case. With that being said each person knows what his home is drawing for a power load. Most of the time my system never draws above 25% of the load. So although I would probably change the wire size? I wouldn’t be in a hurry.

    • @jamesshomesolarmore2223
      @jamesshomesolarmore2223 2 ปีที่แล้ว

      Agree

  • @gardenmaster2422
    @gardenmaster2422 3 ปีที่แล้ว +2

    Looking Nice brother just subscribed

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว +1

      Welcome!! I am so glad that you have joined my TH-cam family!! I look forward to seeing you and responding to your comments

  • @carlossantini
    @carlossantini 3 ปีที่แล้ว +1

    Nice! Whats the energy consumption of the inverter on idle without solar panels working as UPS with batteries and conected to the utility grid? Batteries charging from the grid. Another question, can you measure the sound of the inverter in db?

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      Never actually tested for it, the book indicates 45w but I believe it to be higher. I might run some tests when I rebuild my battery bank. I have Seplus BMS units coming for my 45kw bank (3 x 15kw) and the BMS units daisy chain and talk to the Growatt via CanBus. I'll start new videos then

    • @carlossantini
      @carlossantini 3 ปีที่แล้ว +1

      @@nubiandavis2610 thxs! Dont forget to test the sound level please. I think this inverter might be to loud for an apartment.

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว +1

      @@carlossantini definitely might want to use the 5000w ES model I have for that, MUCH quieter and they can be paralleled.

    • @davidlong1182
      @davidlong1182 2 ปีที่แล้ว +1

      My 6kw sounds like a sr71 taking off. Both deliver the power and plenty of it considering the trade off

  • @davidrejon2418
    @davidrejon2418 5 หลายเดือนก่อน

    Mines says 0 output and the screen reads 04 error what can be done to make it work

  • @Solar_and_Security
    @Solar_and_Security 3 ปีที่แล้ว +2

    Question: How do you feel about the supplier you found? I'm considering doing the same thing. I'm finding that it's more difficult finding one that doesn't feel they are scammers.

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว +2

      I do not have issues at all with Signature Solar in Texas. Very good people.

  • @chriszbodula1894
    @chriszbodula1894 3 ปีที่แล้ว

    Would you let me know the price you paid and where to buy this inverter. Also, can you confirm it has split phase 220vac/110vac. If it has split phase how important is balancing the load on each 110vac leg.

  • @SpoonerTuner
    @SpoonerTuner 2 ปีที่แล้ว +1

    What's the most amps you've fed into it from a 220vac generator? I just hooked up mine (same 12k watt model ) to my generator for the first time to charge my batteries and heard something blow up but it seems to still be working fine. I was at 50 or 60 amps at 220VAC from the generator.

    • @nubiandavis2610
      @nubiandavis2610  2 ปีที่แล้ว

      My solar arrays went as high as 180a of charging so I cannot understand why the 220 generator would cause issue.

    • @SpoonerTuner
      @SpoonerTuner 2 ปีที่แล้ว

      @@nubiandavis2610 I've seen between 50 and 60 of solar but has never been an issue. I'm wondering if it was the AC Input circuit breaker that tripped. I switched everything off so fast I don't remember if it was tripped or not. Thanks for the reply

    • @nubiandavis2610
      @nubiandavis2610  2 ปีที่แล้ว

      @@SpoonerTuner sure thing. Sometimes things go bad. They are pretty modular and you can get a replacement board I am sure.

  • @miabellasalonandmedicalspa2822
    @miabellasalonandmedicalspa2822 3 ปีที่แล้ว +1

    What BMS are you using and it's size? Cable size from battery to inverter?

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      Daly 200a smart bms (2) 4/0 cabling. Upgrading BMS to three (3) Seplus 200a units to run 3 separate 15ah banks paralleled for 45 kw of storage. Might add one more 15kw bank bringing the total to 60 kwh.

  • @krom6017
    @krom6017 3 ปีที่แล้ว +2

    Could you share your settings in the growatt server and breaker wiring? Thank you

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว +1

      Settings will be specific to your battery bank, etc. I use lifepo4 75 kwh so I charge to 58.4 and down to 46v before back to grid.

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว +1

      Wiring, follow your loads. I have my system prepared to run 12kw loads so I size accordingly. 4/0 battery cable, #8 50a for AC

    • @krom6017
      @krom6017 3 ปีที่แล้ว +2

      @@nubiandavis2610 Thank you for the reply, I built two 4p16s 48v and running 12kw growatt. I'm done with one side of panels and ready to flip the breaks for pv and batteries. I kept finding resources that said float was needed. I was wanting to do 80% 53.20 discharge 20% 51.20. But was not sure of the settings that I should use.

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว +1

      @@krom6017 those settings are very conservative and will save your battery life, probably extending it to over 20 years. I'm a Believer and getting max out of batteries therefore I'll run them all the way up to 58.4 and all the way down to 44 volts I mean the difference is 15 years versus 20

    • @krom6017
      @krom6017 3 ปีที่แล้ว

      @@nubiandavis2610 The issue I'm having is the manual and voltage settings correct. postimg.cc/NLXRGK5Q Does not show neutral being hooked up but I have see pictures where neutral is connected. I have the growatt set to 240v but have not load tested yet as the manual is not every explicit about it.

  • @bmwhp4709
    @bmwhp4709 2 ปีที่แล้ว

    I have a question on ERROR messages. You are scrolling the menu and at 2:59 minutes there is 511 with a 810 and then to the right is 01 .. what is this error message mean? I have one of these inverters and even upon turn on stone cold I get this error. Now my point is that Signature Solar told me the error was that my inverter was 196F ... impossible however. The day was only 57F degrees and I just turned it on and this error was there. What do you think?

  • @miabellasalonandmedicalspa2822
    @miabellasalonandmedicalspa2822 3 ปีที่แล้ว +1

    How's it handling your AC unit and what size? I have 4 ton, which the vendor claims the inverter can handle fine. I have the same goal to power all my loads.

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว +2

      It handles any load, period. 5 ton AND a 3 ton. Never breaks a sweat.

    • @srica7366
      @srica7366 2 ปีที่แล้ว +1

      You can add a soft start kit too if it's too many amps. I dropped from 65 amp start to 25 amp on start up on a 3.5 ton. 13.5 amps running, 240v.

  • @MM-uw4lc
    @MM-uw4lc 2 ปีที่แล้ว

    How do you tolerate that fan noise. My neighbors and me are having a terrible time with the noise. How to control it.

    • @nubiandavis2610
      @nubiandavis2610  2 ปีที่แล้ว

      I have an external 4 car building that I use for my equipment so we never hear it

  • @raffiqhaniff581
    @raffiqhaniff581 3 ปีที่แล้ว +1

    Where can I buy this 12 kw inverter. I live in South Africa

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      Reach out to Signature Solar in Texas

  • @sebastienstephanno6814
    @sebastienstephanno6814 3 ปีที่แล้ว +1

    Great video Nubian
    How many watts power solar do you recommend to best perform/run on this unit.
    I’ve recently bought a battery Bank of 26.4KW -48 V 550AH (6 V cells )
    I currently looking at a Growatt 12k
    We’re currently consuming an average of 24k per day.
    Your video is extremely helpful for anyone who’s wanting to back themselves up from the gridd.

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      Excellent start. Those 6v cells are they lead acid or lithium? Welcome to the channel!!

    • @sebastienstephanno6814
      @sebastienstephanno6814 3 ปีที่แล้ว +1

      @@nubiandavis2610 thanks for your prompt reply.
      Lead carbon batteries, from my recherche they’ve a high cyclic life of 7000 cycles (30% depth of discharge), extended lifespan of up to 20 years, and resistance to sulfation. These are some of the best off grid batteries available in the Australian market to date.

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      @@sebastienstephanno6814 that is excellent. I remember Outback Power making such batteries a few years ago

  • @lizaramos412
    @lizaramos412 3 ปีที่แล้ว +1

    How do you add LiFePo4 batteries later without damaging their DOD or life cycle?

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      Create a new 16s bank and add away. All my cells are pretty new so it will not pose any issue

    • @lizaramos412
      @lizaramos412 3 ปีที่แล้ว

      @@nubiandavis2610 I have bought the same inverter, Growatt 12kW. Could you please be more specific on how I should connect a second battery bank?

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      @@lizaramos412 you must parallel the 2 banks. Positive to Positive and negative to negative of the 2 banks to a bus bar then feed the inverter from the bus bar

    • @lizaramos412
      @lizaramos412 3 ปีที่แล้ว +1

      @@nubiandavis2610 What I heard from the Dyness manufacturer is that mixing different chemistry can damage the Lithium batteries and mixing different old and new batteries could affect batteries life.

    • @lizaramos412
      @lizaramos412 3 ปีที่แล้ว +1

      @@nubiandavis2610 I will follow your setup, will look for the bus bar here in Paraguay, which is a little more difficult than in the US :)

  • @JimNichols
    @JimNichols 3 ปีที่แล้ว +1

    I didn't see the primary solar array output on the inverter.... I looked into a system like this and the cost is prohibitive in Thailand. Ample sun, cells are cheap, inverters are cheap here (as they are made in country) but LiPos are crazy expensive as they are not made in country and face a HUGE VAT tax.

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      The screen is a toggle per page so you must cycle through to get to the information that you want. Too bad about Lifepo4, they are what you will need primarily

  • @JohnWick-xz9tc
    @JohnWick-xz9tc 3 ปีที่แล้ว +1

    looking good

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว +1

      thanks!! I cannot believe what this thing can handle. I have not seen load handling like this since my Outback Radian 8048a

  • @iancampbell1526
    @iancampbell1526 2 ปีที่แล้ว

    However isn't this inverter only take in 150vdc how did you get the array to carry that 5kw load

  • @JungleJargon
    @JungleJargon 3 ปีที่แล้ว +1

    Believe it!

  • @duunoit
    @duunoit 3 ปีที่แล้ว +1

    Is the 2nd MPPT Charge Controller (Outback?) wired in to the Growatt? I saw that it was possible and I see it on your LCD, but didn't see anything in the manual on how it would be done. Thanks

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว +3

      No, the outback goes directly to the bus bars to feed the batteries. The Growatt has 2 of it's own mppt controllers 60a each 120 total (7000 watts)

  • @iancampbell1526
    @iancampbell1526 2 ปีที่แล้ว

    This is nice

  • @JonOffgrid
    @JonOffgrid 3 ปีที่แล้ว +1

    i like Growatt

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว +1

      A few bugs but they can power loads. That's the long and short of it

  • @rustusandroid
    @rustusandroid 3 ปีที่แล้ว +1

    Good stuff. Solar is FUN, isn't it :)

  • @One.--
    @One.-- 3 ปีที่แล้ว

    2 huge transformers

  • @Engraveyourgift
    @Engraveyourgift 3 ปีที่แล้ว +1

    Dos your inverter turn off randomly during a weak of operation?

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      No it is always on 24/7

    • @Engraveyourgift
      @Engraveyourgift 3 ปีที่แล้ว +1

      @@nubiandavis2610 then mine is definitely defective. The thing is it turns right back on and you don’t even notice it. Unless you have an energy monitor. And you can see it in the run time history.

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      @@Engraveyourgift If you got it from Signature Solar, call support and tell them you need a replacement system board. It is a very easy swap and you will get the new model of it that has the ability to read grid consumption. The original board did not do this. I received an upgraded board from Growatt direct in China a while back but all of the new ones they send out to therir distributers is the newer model.

    • @Engraveyourgift
      @Engraveyourgift 3 ปีที่แล้ว +1

      @@nubiandavis2610 yes I did buy from Signature Sola. But for me the customer service has been a nightmare. And I do not trust that company at all. Thank you for the tip.

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว +1

      @@Engraveyourgift give them another chance, they are pretty good.

  • @mitchrothermel8157
    @mitchrothermel8157 3 ปีที่แล้ว +1

    Can you use ac coupling ??

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      I suppose you can however the Growatt platform is a off grid solution therefore it does not have the logic to work in that fashion. My Outback Radian 8048A could do that. I know the Solark can. The issue is the Solark and Outback systems cost twice as much as the Growatt 12k. Just not worth it to me. I can craft how many panels I need and how much battery storage I require to run solar days / batteries night. That is exactly what I set this up to do. I do wish Growatt had 10kw of solar input and not limit it to 7kw, that would have been a plus.

    • @mitchrothermel8157
      @mitchrothermel8157 3 ปีที่แล้ว +1

      @@nubiandavis2610 I see, I have an existing 2.6. Kw powering a Sma sunny boy grid tie with another 2.5 going to a 18kw battery (Chevy volt battery)that I am using a 1.7kva ups to run my house at night. And that works perfect but my day grid solar goes out and I don’t get compensated for it. I have an growatt and another 22kw of lifepo4. I just didn’t want to waste that system and buy another mppt charger and rewrite my solar for the lower volt charger. I know there is 600v but it’s just to much right now.
      Thanks
      Mitchell

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว +1

      @@mitchrothermel8157 I have learned over time that you will ALWAYS be building your system. I have a lot of duplicate items but remember this - 2 is 1 and 1 is none. Get what you need now - trust me, the rainy day is definitely coming

  • @efrainpatino5637
    @efrainpatino5637 3 ปีที่แล้ว +1

    Hi, what's the maximum PV voltage that this Inverter handles? - I Read the specifications and it said 150VDC, is there any problem with the 176VDC of your video ?

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      I have the HV edition which can handle 250v DC input x 2 PV inputs. 3500w each totalling 7000w.

    • @efrainpatino5637
      @efrainpatino5637 3 ปีที่แล้ว +1

      @@nubiandavis2610 great!! How do i know if my edition is HV too?

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      @@efrainpatino5637 the model number tells what the voltage is

    • @josesantiagosanchezsanchez3154
      @josesantiagosanchezsanchez3154 2 ปีที่แล้ว

      @@nubiandavis2610 GREAT VIDEO...spf 12000t dvm - mpv is the model for 250v cant find it as HV... READY TO PULL THE TRIGER ANY MINUTE ,,,THANKS FOR THE INFO...

  • @ai4px
    @ai4px 3 ปีที่แล้ว +1

    What is the 48v idle current on that inverter?

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      Honestly, for my use case it is never idle. I can try and find out for you.

    • @ai4px
      @ai4px 3 ปีที่แล้ว +1

      @@nubiandavis2610 Thanks so much! I'm very curious. I have a pair of sunny islands that make 12kw and they draw 1.2amps @ 48v at idle. That's remarkably low so I'd love to compare. Hey do you have a video on your battery?

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      @@ai4px those SI units are very efficient. I wanted to actually get a pair when they were all over last year but never did. This is a working unit and gets absolutely zero downtime. Check my videos, I am sure I detail my battery somewhere.

    • @ai4px
      @ai4px 3 ปีที่แล้ว +1

      @@nubiandavis2610 Ok, thanks... I've been watching a lot of your stuff today. Great info. As for our sunny islands, I wanted to grab a spare recently and the price is back up high again... wish I would have gotten more when they were $1200 on ebay. They are the Cadillac of inverters.... lots of over load capacity and very low idle current.

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว +1

      @@ai4px yes definitely at 1200. Not at what they cost now. Easier to get a 12kw Growatt

  • @mikemjm748
    @mikemjm748 2 ปีที่แล้ว

    Where did u buy this and can I parallel x2 12kw together for a total of 24 kw system ?

    • @martinkeding4228
      @martinkeding4228 2 ปีที่แล้ว

      According to the spec sheet, you can’t parallel these. However the 5k model can be paralleled up to 6 units. You may also need a transformer for 120/240 as the 5k does not have this built in.

  • @noahjohnston
    @noahjohnston 3 ปีที่แล้ว +1

    I'm liking most things about this, except that it's so dang noisy I'd need a spare room just to keep the noise away. I live in LA, and I can't afford an extra 200k of house just to have a place for the inverter.

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      Its true, very loud fans to move that heat away. Most put it in the garage

    • @One.--
      @One.-- 3 ปีที่แล้ว

      Stick it in the garage man

  • @defjamsgreen
    @defjamsgreen 3 ปีที่แล้ว +2

    Subscribed to ya . The Growatt LF inverter is sure a beast when it comes to running almost every heavy loads in the whole house . We DIY preppers are #1 when we depend on power , quality and efficiency in our system at this time & age when it is needed during any outages or to save on the light bill at will . When you get a chance , check out my solar videos , hit like , leave a message and subscribe . May the solar be with you .

  • @onthelake9554
    @onthelake9554 3 ปีที่แล้ว +1

    So how long have you ran it at 12k output continuously ?

  • @jonathnrivers6730
    @jonathnrivers6730 3 ปีที่แล้ว

    Cool 😎

  • @mehmedmehmedov5901
    @mehmedmehmedov5901 2 ปีที่แล้ว

    wery nice

  • @MM-uw4lc
    @MM-uw4lc 2 ปีที่แล้ว

    Now my fans activate every 5 minutes when in solar.

  • @JonOffgrid
    @JonOffgrid 3 ปีที่แล้ว +1

    They are nice but fan runs all the time on our s

  • @Gallardo6669
    @Gallardo6669 2 ปีที่แล้ว

    READ THIS !!!!
    I bought this inverter because I wanted to generate solar power, using this solar power and feed in additional grid power at the same time whenever solar isnt enough. I wanted to use the battery power only for grid outages OR, eventually use battery power during a few hours per day, when our utility company charges higher rates during peak hours. This inverter cant do this, even the seller told me it would do this!
    Issues i had in detail:
    No 1: Inverter cant provide solar and grid source simultaneously
    Either if setting Menu 1 is SOL or SBU, the inverter is always using battery power when solar isnt enough, until the battery reaches its low voltage setting from menu 12. That means throughout the day the inverter is hundred of times tapping into the battery, back and forth switching. This wears on the battery and the internal relay.
    No 2: PV charging current is always wrong ( display " Input PV A")
    This value is always wrong. For example I could prove with Amp clamp/Voltmeter a production at the moment of 1,6kw, the PV Voltage stated 130 Volt and PV charging current stated 32Amp. This turns out to be almost twice as much as my panels are rated for.
    No 3: Wrong display information
    PV charging power ( "PV Batt kw") is actually NOT the charge power. It is indeed the actual solar production and this number is way off of what is described under No 2.
    The actual charge power is always way less, proven by Voltmeter and Ampclamp. PV charging power is actually production, proven by Voltmeter and Ampclamp.
    No 4: Solar production limited
    For a long time I scratched my head why this system isnt producing what it should. the battery is constantly making up for the difference to supply the load. Then i found out that" PV charging power" is actually production in watt and was LIMITED by the inverter: It makes no sense at all that the actual production drawn from the panels is reduced by setting Menu 2. Menu 2 supposed to limit the maximum charge current (as per manual), to protect the battery of getting overworked or hot. Menu 2 should be totally independent from the actual production, every single watt not going into the battery should be available for the loads.
    As soon as I changed setting menu 2 from 30 to 100 the production went up, and what I measured with voltmeter and ampclamp was indeed matching PV Batt W, which want to be a "charge power".
    No 5: In regards to a question to Error 61 I was sent information on how to calibrate the voltage measuring feature. No I wont do it, thats something a manufacturer has to do, thats not the customers job.
    No 6: No clean solar cut in/out
    When solar production reaches its threshold the build in charger should read the low Amps and cut in or out one single time. Instead the charger toggles maybe 20 or 30 times on and off until solar is clearly beyond the treshold. this doesnt make sense at wears out relays or switches.
    Seller and user manual cant describe owner what menu 26 is for....
    If there is never enough solar power for the loads the inverteris wearing out batteries prematurely. Settings dont make sense and work counter productive. Values given in the displays are wrong. The user manual is misleading and lacks a lot of explanation.

  • @fred8565
    @fred8565 3 ปีที่แล้ว +1

    man that's very noisy

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว +1

      It is a 12000w low frequency high power inverter. It is not meant to be quiet, it is meant to power loads 24/7 with 89% efficiency. Put it in a outbuilding.

  • @bobbythomas5357
    @bobbythomas5357 2 ปีที่แล้ว

    Quite noisy

  • @johnschnee3934
    @johnschnee3934 2 ปีที่แล้ว +1

    We are Saved by Grace Through FAITH NOT WORKS. Salvation is a free gift from GOD given to those all who will believe LORD JESUS CHRIST DIED AS A SALVATION LAMB for our sins by the BLOOD OF LORD JESUS CHRIST HIS BLOOD CLEANSES Our SINS !

    • @hufartd
      @hufartd ปีที่แล้ว

      Speak for your own sins buster,
      The most of us are managing not to be shits to each other without an omnipresent overseer.

  • @TheFatman819
    @TheFatman819 3 ปีที่แล้ว

    It can only handle 9k of solar and cannot be paralleled, not a beast. The Sol-Ark runs all over this

    • @nubiandavis2610
      @nubiandavis2610  3 ปีที่แล้ว

      I would imagine the sol ark should run all over this thing that it cost twice as much.

    • @TheFatman819
      @TheFatman819 3 ปีที่แล้ว

      @@nubiandavis2610 Did you know Growatt software allows them full access to your system, they can even turn it off?
      I have been watching them for the past year, how much control do people want to give away.

    • @jeffbowers950
      @jeffbowers950 2 ปีที่แล้ว

      At 3-4 times the price. And the sol-ark will NOT produce 12 KWh continously. Deceptive marketing on their part which is too bad. I like their products but I will not pay top dollar for a product advertised as 12 KWh when in reality it is only 9 KWh.
      That equates to a lie in my book.

  • @mars-cs4uk
    @mars-cs4uk 2 ปีที่แล้ว

    This is only for rich people who don't know what to do with their money. I can build one with less than 50 grand.

  • @Gallardo6669
    @Gallardo6669 2 ปีที่แล้ว

    I have some issues to understand the manual and display. Is there a way you would support me? Email or text/ call? Would highly appreciate it!

  • @yarah12stones94
    @yarah12stones94 ปีที่แล้ว

    Suggestion, fear Yahawah and Keep his commandments. Shalam Malak