You don't need air conditioning anymore!

แชร์
ฝัง
  • เผยแพร่เมื่อ 14 ต.ค. 2024
  • I made almost free cooling of my workshop with geothermal free energy from the earth.

ความคิดเห็น • 911

  • @Yeet_Sir
    @Yeet_Sir 2 หลายเดือนก่อน +346

    The title of this video is confusing. It should read: `If you have the well from the movie "The RING", this air conditioning system is for you too!"

    • @bertjesklotepino
      @bertjesklotepino 2 หลายเดือนก่อน +5

      I always bury my feet and arms when i am on the beach.

    • @zafergungor1912
      @zafergungor1912 2 หลายเดือนก่อน +1

    • @Ranmauzo
      @Ranmauzo 2 หลายเดือนก่อน +8

      And leaving the cover half off a deathtrap like that will get you a wrathful spirit haunting your ass right quick, too.

    • @bobb.6393
      @bobb.6393 2 หลายเดือนก่อน +1

      @@bertjesklotepinoI tried but Florida sand is too hot

    • @bobb.6393
      @bobb.6393 2 หลายเดือนก่อน

      @@Ranmauzoyes you too can be a spirit

  • @OneWildTurkey
    @OneWildTurkey 2 หลายเดือนก่อน +108

    In 1982 I rented an apartment in a complex with 600 units that had geothermal cooling & heating.
    It was nice, the electric bill was about 1/3 of normal costs.

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน +8

      👍👍👍👍

  • @ljprep6250
    @ljprep6250 2 หลายเดือนก่อน +91

    Very nice. Now insulate the inlet hose from the well to the cooler so you don't lose any coolth there. And if you paint the inside of your shop with pure white paint, it will give you twice the light inside that you have now and require 1/4 to 1/2 the amount of LED lighting to make it very bright. I painted the shop floor white, too, and it makes dropped screws easier to find.

    • @dennissorensen8765
      @dennissorensen8765 2 หลายเดือนก่อน +1

      Paint it with Spectralon next time. 😂😎😎

    • @HelloKittyFanMan
      @HelloKittyFanMan 2 หลายเดือนก่อน +2

      Haha, "coolth." Oh yeah, ended like the word "warmth"! But I wonder why I had never seen or heard that word "coolth" before even though we hear "warmth" fairly often. Hmm!

    • @lajoswinkler
      @lajoswinkler 2 หลายเดือนก่อน +2

      There's no such thing as coolth. There is only heat and less heat.

    • @ohger1
      @ohger1 2 หลายเดือนก่อน +2

      @@lajoswinkler My mother always used "coolth". Good enough for me!

    • @HelloKittyFanMan
      @HelloKittyFanMan 2 หลายเดือนก่อน +3

      @@lajoswinkler: We don't have the word "cool" for nothing.

  • @philjohnson725
    @philjohnson725 2 หลายเดือนก่อน +189

    Nice! Got the fans, got the radiator and pipes. Got the pump. Now I just need the well. Now where to get a well...mmm

    • @azteacher26
      @azteacher26 2 หลายเดือนก่อน +13

      Not just a well but a wide shallow well. My last home had a 7inch well at 400 feet. You can't really make a cost effective system with deep wells. Unless of course you're pumping the water into another insulated container??

    • @werner.x
      @werner.x 2 หลายเดือนก่อน +5

      Underrated comment.

    • @kevingallineauii9353
      @kevingallineauii9353 2 หลายเดือนก่อน +4

      @@azteacher26 pretty sure you can just pump it back into the well. I would not use the same well for geothermal and potable water though.

    • @onmyworkbench7000
      @onmyworkbench7000 2 หลายเดือนก่อน +5

      Got the well but I don't have the fans, the radiator, hoses or the pump.

    • @jipede
      @jipede 2 หลายเดือนก่อน +1

      @@azteacher26 You need a heat exchanger and two circuits, one circuit from the heat exchanger to the well with a pump and then a circuit connected to the heat exchanger to the cooling unit with another pump.

  • @Dr_Larken
    @Dr_Larken 2 หลายเดือนก่อน +75

    So I was trying this on one of our properties, thought I was doing good using the well in the backyard!
    Only to find out later on as I was told, we don’t have well ! It was the septic tank!

  • @Onionbagel
    @Onionbagel 2 หลายเดือนก่อน +80

    I like the video, but lets try to be realistic here' about that last comment you made... A small 5000 BTU A/C is only about 350-500watts. That's all you need for a shed that size. A 3,000 watt A/C would be overkill.
    A/C's have become very efficient over the last decade or so. Other than that, I know it's not really about power-draw and more about sending a message, so still, fantastic video!

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน +8

      👌🤝

    • @WJCTechyman
      @WJCTechyman 2 หลายเดือนก่อน +5

      My thoughts exactly.

    • @chrisdaniel1339
      @chrisdaniel1339 2 หลายเดือนก่อน +5

      I would rather build a cooling system myself than to pay for an air con unit from some faceless mega corporation. He could upscale this with a copper coil in the well, insulating the lines from the well into the house, and use a larger heat exchanger in the house. Or he could use and old HVAC air handler unit from a house and instead of refrigerant he pumps the ground chilled water through the refrigerant heat exchanger and it would even have drip pans to catch the condensate and be easy to hook to a digital thermostat.

    • @DanielJacksonisbiggerinside
      @DanielJacksonisbiggerinside 2 หลายเดือนก่อน

      Agreed. Look at the temperature delta between the water coming in and the water going out. If that's all the temperature differential you needed, there are lots of ways to do it just as efficiently.
      That said, the well is a huge asset. So much thermal capacity, and it's right there. Being able to easily return your cooling water to the well makes the energy transfer potential really big, though it also leads to questions about safety for drinking water. (Not saying you shouldn't try it, just I'm pretty sure regulations prevent us from trying this on a larger scale because safe water is a high priority for municipalities.)

    • @billsmith7673
      @billsmith7673 2 หลายเดือนก่อน +1

      I actually have a 5000 BTU window unit cooling the entire first floor (1112sf) of my house and it is not well-sealed and insulated at all due to undergoing a remodel. I also have a 5000 BTU window unit that does a great job of cooling a 12x24 (288sf) outbuilding that is poorly insulated, and this is in 95deg Southern U.S. weather.

  • @bryansmith2649
    @bryansmith2649 2 หลายเดือนก่อน +37

    The concept is solid, but the straight water through the heater cores will corrode them quickly if they aren’t first plugged by trash in the water from being an open system. Also the condensation on the coils would make a mess in the shop with no drip pan under it. A closed loop system in the well would work better, but antifreeze might leak into the water system eventually.

    • @shadrach5681
      @shadrach5681 2 หลายเดือนก่อน +17

      Closed system with distilled water. No corrosion and a leak wouldn't matter.

    • @ThiagoMarquardt
      @ThiagoMarquardt 2 หลายเดือนก่อน +1

      And expansion tank

    • @pawelw.9172
      @pawelw.9172 2 หลายเดือนก่อน

      you are looking for problems where there arent any. corrosion? he will replace it, how much stuff you find in the AC unit? there is brass corrossion and radiator corrosion too and lots of electronics.

    • @c.e.ardanaz1234
      @c.e.ardanaz1234 หลายเดือนก่อน

      La idea es ir desarrollando el experimento y mejorándolo, Roma NO se hizo en un dia !!!

  • @maretranquillity
    @maretranquillity 2 หลายเดือนก่อน +93

    You might be surprised to learn that many people do not have a wire feed welder, a shop, a 3D printer, or a deep well, but good for you.

    • @ahuman4386
      @ahuman4386 2 หลายเดือนก่อน +11

      Was going to say something like that too. Its easy and anyone can do it. First, you need a machine shop and thousands of dollars for tools and equipment and a water well handy near by and oh, skills in using all those things too!
      Nah dude, I just buy a $150 5000 BTU running at 300watts and its more than enough, thanks.

    • @masterzloster1198
      @masterzloster1198 2 หลายเดือนก่อน

      Actually you don't need it, it is possible to use indoor or outdoor unit from broken (inop) ac. All you need is to connect some wires and hoses.

    • @gobblinal
      @gobblinal 2 หลายเดือนก่อน +3

      Step 1: Be rich.

    • @bobb.6393
      @bobb.6393 2 หลายเดือนก่อน

      @@gobblinal eminence front "the who"

    • @josephwisniewski3673
      @josephwisniewski3673 2 หลายเดือนก่อน

      My house has a capped well. I've toyed with this idea, on and off, for 30 years.

  • @yargnad
    @yargnad 2 หลายเดือนก่อน +48

    Title: "You don't need air conditioning anymore!"
    Content: Proceeds with building an air conditioner...

    • @klausstock8020
      @klausstock8020 2 หลายเดือนก่อน

      Technically, an "Entwärmungsanlage" ("heat dissipation system").

    • @yargnad
      @yargnad 2 หลายเดือนก่อน +3

      @@klausstock8020 Technically, still "conditions" the air.

    • @klausstock8020
      @klausstock8020 2 หลายเดือนก่อน +3

      @@yargnad Yes. It was just that I wanted to tell you that I'm a nitpicky German without telling you that I'm a nitpicky German 😀

    • @lisescheiman5092
      @lisescheiman5092 2 หลายเดือนก่อน +1

      Is that ether in your pocket?

  • @chronobot2001
    @chronobot2001 2 หลายเดือนก่อน +38

    Nice solution if you have a well available.
    Unfortunately, most people don't.

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน +10

      Unfortunately you are right...

    • @Sekir80
      @Sekir80 2 หลายเดือนก่อน +3

      You don't need a well if you have a property where you can dig a trench a couple dozen meters. Or hundreds. Unfortunately, I haven't find a good tool for calculating soil heat disspation and saturation so I can't calculate the trench length for a given property size to cool. I paste my comment from above I found to do this: dig a 1-2 meters deep (as above) a long trench; put large diameter plastic tubing in it; route one end of the tube out the soil, the other end of the tube into the shed/home; attach fans to the tube. This will blow fresh (and hot) air into the tube, goes underground and cooling down, enter the property cooled.

    • @RuFiOxOG
      @RuFiOxOG 2 หลายเดือนก่อน +1

      It’s not hard to dig your own well depending on where you live, I dug my own a few years ago 20ft deep.

    • @normbograham
      @normbograham 2 หลายเดือนก่อน +1

      in two houses, there were abandoned wells, or old septics, that clearly were full of water. I'd say, lots of people have them, but they are clueless.

    • @jimwing.2178
      @jimwing.2178 2 หลายเดือนก่อน +1

      @@Sekir80 Cool tubes were tried back in the 1970s, they don't produce enough effect to make them worth the hassle, especially dealing with liquid water, high humidity, and mold.

  • @NAVYABHAN
    @NAVYABHAN 2 หลายเดือนก่อน +41

    The Backyard Garage Geniuses are the True Fathers of Technology!

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน +4

      Thank you so much my friend! I'm glad you liked my video. Come back to my channel, there are still a lot of interesting and unusual ideas. I will always be glad to see you. 🤖

  • @scubasmitty5135
    @scubasmitty5135 2 หลายเดือนก่อน +68

    The BEST A/C and heating would be an underground home !!!!

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน +5

      🤣🤣🤣👍👍👍👍

    • @hoekbrwr
      @hoekbrwr 2 หลายเดือนก่อน +10

      My son had a simple 1 floor home in Minnesota with a cellar with the same floor plan. The working area and our guest bedroom were in the cellar. You could live in the cellar during those hot days over there and in winter the top floor could be heated also! That was a simple house but very practical.

    • @darrellturner560
      @darrellturner560 2 หลายเดือนก่อน +9

      Move to Cooper Peddy South Australia. Everyone lives underground.

    • @HeartFeltGesture
      @HeartFeltGesture 2 หลายเดือนก่อน +2

      I think we will be seeing this type of home design more and more as we all start to cook on the surface.

    • @Coladudetje
      @Coladudetje 2 หลายเดือนก่อน +8

      But then you have other issues like radon gas, moisture, bad air.

  • @ILGuy2012
    @ILGuy2012 2 หลายเดือนก่อน +3

    When I was in high school, I considered building something similar to cool my parents' home. We had an old well to use as a source of cooling. I had planned to use a radiator from an old car and use a box fan to blow air through the chilled radiator. My hangup was finding a pump that would be powerful enough to pump the water up from the well and through the hose connected to the radiator. Another issue was how to best capture and remove the condensation water that would be dripping off of the radiator.

  • @baneverything5580
    @baneverything5580 2 หลายเดือนก่อน +3

    There are air conditioners now that use 200-250 watts. My small window ac uses 400 to 500 depending on outside temperature. If it`s only 80 to 85 outside it runs very efficiently. My June electric bill in subtropical Louisiana was $41. I want one of the 200w models with 8000 btu to use with solar but I can get three 5000 btu ones for what it costs.

  • @garrydunkley1000
    @garrydunkley1000 2 หลายเดือนก่อน +21

    It would work better if you put the indoor unit high up to condition the hottest air ! But nice one ,
    I have an ac that runs off my solar system so it’s all good 👍

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน +5

      Thank you very much my friend! I will definitely try to take your advice.

    • @PinePondCTDevilsHopyard-fy3hj
      @PinePondCTDevilsHopyard-fy3hj 2 หลายเดือนก่อน +2

      And add a plastic drip pan with a drain hose for the condensation.

    • @JakeRomanak-vn4sw
      @JakeRomanak-vn4sw 2 หลายเดือนก่อน

      You want to keep the lighter hot air high and let the cool air settle

    • @protorhinocerator142
      @protorhinocerator142 2 หลายเดือนก่อน

      I would install some form of duct work as well, if only to prevent air recirculating through the heat exchanger. You want to pull the hottest air in the room through the fins and have the cold air not mix with the hot inlet air.
      It's most efficient when the cold air goes into the room and does the work before returning as inlet air.
      In a workshop that means pointing the unit to the hottest heat source, which is often the window where the sun comes in. Aim the cold air at the window to do the most work. It sounds counter-intuitive but this will give you the best effect without heat or cold spikes in the room. It will be the most comfortable.
      You could also add a gizzy that activates the device above a set temperature. An old school thermostat with the mercury bulb would probably be ideal.
      Then once it cools down to a reasonable temp, the unit shuts itself off.

  • @juicymelodic
    @juicymelodic 2 หลายเดือนก่อน +8

    This is honestly a lot of work for nothing. You could just pump the cold air out, no need for an elaborate setup. Additionally you'd get fresh great quality air especially if you add zeolite filter. Ground cooling is very popular here in Poland a simple fan cools better than an AC unit.

  • @martyclack8782
    @martyclack8782 2 หลายเดือนก่อน +2

    Nice water cooler. The water on a complete loop thus you have cool air from it. Just a simple design. Awesome.

  • @GothGuy885
    @GothGuy885 2 หลายเดือนก่อน +10

    NOTE: Requires a welder, welding Skills, 3D printer, and a water well on your property.
    Awesome project tho, if you have or can afford all this stuff....

    • @codemaster3696
      @codemaster3696 2 หลายเดือนก่อน

      You can certainly do it without having any of those tools, and in most US locations you can easily bore your own well *with nothing more than a little water pump or electric power washer.

    • @ATomRileyA
      @ATomRileyA 2 หลายเดือนก่อน +1

      You could probably replicate this much cheaper without all those tools,
      Find a old car radiator, then dig some trenches a few feet deep bury some water hose for the cold ground loop, you could use PVC hose pipe although there are better options (Polyethylene or HDPE).
      Would have to work out how much hose and the depth to make it work but typically ground loops are places 3-6ft deep and have a few hundred feet of hose underground but they are large systems for whole house geothermal heater/coolers.
      I bet you could have some success with a much smaller system.
      From what i read 700ft of hose is good for 12000btus for geothermal heaters.
      Need to find a pump but as its not so deep as the well don't need anything crazy i bet some of those aquarium pumps could be used although you would have to work that out. There are tons of heating circulator pumps that would work well and can be found for cheap,
      Get some old solar panels to power it as well.
      I had a idea for using some large pvc pipe buried horizontally say 6 ft buried with the top exposed that way when it rains it fills up with water, get a bunch of these buried and you would have a good amount of water buried keeping cool from the ground temp, then just circulate water through all the pipes and you would have a similar effect to the well.
      Also you could drill them into the ground like they do oil well drilling, but on a smaller scale. Imagine a 2inch pvc pipe with one end cut to be jagged (with the end of this pipe sealed but the jagged part sticking out) so when it is turned by something like a drill it cuts into the soil making it easier to bore into the ground, you might need to build a wooden frame to make this easier.
      You could take small 4ft lengths and then join them together to make longer and longer bore holes until the limit of the drill.

  • @webadage
    @webadage 2 หลายเดือนก่อน +9

    You don't need air conditioning anymore..... but you need a TIG welder, a 3D printer, a couple of perfectly good automobile AC radiators and.... wait for it... a 100 foot open well located near the building that needs to be cooled. It's just that simple is it?

  • @navinyadav864
    @navinyadav864 2 หลายเดือนก่อน +5

    That is really "down to earth" in cooling ,
    i was planning literally the same thing in my house , you put it together already ,
    Itbid awesome bro

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน +1

      Thanks bro! This idea works great. But some minor modifications are needed - condensate removal and a closed circuit can be made.

    • @rogierius
      @rogierius 2 หลายเดือนก่อน

      ​@@Doctor-Robo, please ignore my ignorance, but closed circuit of what?

  • @domirimba
    @domirimba 2 หลายเดือนก่อน

    I like the well as a cold source, but you should consider something to collect condensation at your heat exchanger. If you want to reduce noise you can increase the surface area of your heat exchanger (more radiators) and hang them on the ceiling so the cold air will just drop on you. I myself have a closed loop system at home meaning a heat exchanger 140 m below surface as my cold source with salty water running through it and then through my ceiling to cool us down. It combines very well if you just power it with a solar panel or 2 because when the sun shines you need cooling the most. I keep my ceiling above the dew point to prevent condesation by measuring air temperature and humidity, but for that you need a very large surface area so you have sufficient cooling.

  • @melissasmess2773
    @melissasmess2773 2 หลายเดือนก่อน +5

    My manufactured home used to have ground water cooling for the central air system .😊

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน +1

      👍👍👍👍

  • @billybahlah
    @billybahlah 2 หลายเดือนก่อน +1

    That’s great! I made something similar, unfortunately I don’t have a cold water source, so I use a cold box and filled with bottles of ice.
    However it melted the ice and warmed the water so quickly I gave up the approach.
    Bought a portable AC unit instead

  • @justliberty4072
    @justliberty4072 2 หลายเดือนก่อน +9

    "I printed a control unit." I don't think we are there quite yet...

  • @jimthebutcher99
    @jimthebutcher99 หลายเดือนก่อน

    It is called a swamp cooler. You can buy them just about anywhere in many different sizes but they only work where the humidity is low. If you are in a high humidity area it does not work.

  • @hellopsp180
    @hellopsp180 2 หลายเดือนก่อน +4

    Someone Call Linus. Because this guy just Watercooled his Shed :)

  • @clintstegall1069
    @clintstegall1069 หลายเดือนก่อน

    Man, that was one of the coolest things I have ever seen, no joke, I have been around wells all my life.

  • @rchrdgrn
    @rchrdgrn 2 หลายเดือนก่อน +3

    This only works when ground temperature is significantly lower than Outside temperature. I live in florida ground temperature in seventy two.

    • @PinePondCTDevilsHopyard-fy3hj
      @PinePondCTDevilsHopyard-fy3hj 2 หลายเดือนก่อน +1

      Correct, up here in CT the water from our well is about 55f degrees.

    • @pappapappi9177
      @pappapappi9177 2 หลายเดือนก่อน +1

      The deeper the well, the cooler the water..
      In a region where summer temperature reaches 45-50 Celsius, the water reservoir with mostly surface level two meters deep you would chill by just plunging your hands in a pail of that water.

    • @adrians6740
      @adrians6740 2 หลายเดือนก่อน +1

      Even a 10 degree difference has a big impact

  • @josephwisniewski3673
    @josephwisniewski3673 2 หลายเดือนก่อน

    The first time I encountered a cooling well system, it was considerably larger than yours and used full-up car radiators, not heater cores. It cooled the Riverside roller skating arena in my home town, a western suburb of Detroit. This was around 1972. Dad wanted to drill a cooling well and make a similar system for our home.

  • @ronpalmer1371
    @ronpalmer1371 2 หลายเดือนก่อน +13

    That’s great, all I need now is a similar well in the garden

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน +4

      Be smarter! Bury 10 yards of pipes deep enough in your backyard to replace a well.

    • @rogierius
      @rogierius 2 หลายเดือนก่อน

      ​@@Doctor-Roboindeed, in my part of the world it's 12° to 15° Celsius close to the surface.

    • @chriskopeikin2702
      @chriskopeikin2702 2 หลายเดือนก่อน

      No shit, lol, that’s what I am saying haha. Just need a 20 foot deep well with ice cold water lol.

    • @chriskopeikin2702
      @chriskopeikin2702 2 หลายเดือนก่อน +1

      So you’re able to cool the room because you have access to a never ending supply of super cold water? Is that correct? What if we don’t have that?

    • @ronpalmer1371
      @ronpalmer1371 2 หลายเดือนก่อน +1

      @@Doctor-Robo good thinking 👍🏻

  • @HolicCreation
    @HolicCreation 2 หลายเดือนก่อน

    Great video, I am totally amazed at how you cooled the room with this method. You are a master of ideas.

  • @batuwitamaithri9789
    @batuwitamaithri9789 2 หลายเดือนก่อน +3

    මගේ අදහසනම් හොදම ජිවත්වෙන්න ලංකාවේ පරණ මැටි ගෙවල් සහ පොල් අතු වහල.මැටි පොළව කියල

  • @mikemotorbike4283
    @mikemotorbike4283 2 หลายเดือนก่อน +2

    It's frustrating watching those pipes get pinched by the lid. Otherwise, congrats, great idea and execution!..But a concern is to assure the groundwater flows fast enough through the well. Pathogens, fungus etc grow in heat. Would a larger rad increase the differential between the incoming and outgoing water? I notice briefly on the thermal image the tubes were almost the same colour coming in as going out. Perhaps another rad outside on the returning pipe to dump the heat before reintroducing the water back into the well? It would be interesting to plot the temperatures, because an exterior rad may actually introduce ambient air heat into the well if the temp is still cool leaving the inside rad.
    If you can create a greater difference, you could run your pump and fans less to save money. Of course, a heat pump "water chiller" water to air, might be ideal. Depends on whether the well groundwater flow can remove the heat fast enough, I guess. Your innovation might help a lot pf people, including farmers trying to cool their livestock.

  • @AldousHuxley7
    @AldousHuxley7 2 หลายเดือนก่อน +12

    Very cool I wonder if a single radiator in a buried 55 gallon drum filled w water would do anything

    • @ObsceneSuperMatt
      @ObsceneSuperMatt 2 หลายเดือนก่อน

      If you try it, let us know the results!

    • @azteacher26
      @azteacher26 2 หลายเดือนก่อน +6

      This system works because of the size of the aquafer and the depth under the ground. You take both those advantages away when you reduce the water size and the depth.

    • @ObsceneSuperMatt
      @ObsceneSuperMatt 2 หลายเดือนก่อน

      @@azteacher26 Depends on how deep you bury the barrel. The size of the reservoir only matters if it isn't transferring the waste heat to the surrounding ground fast enough.

    • @kevingallineauii9353
      @kevingallineauii9353 2 หลายเดือนก่อน

      @@azteacher26 That is true. You probably could make an evaporative cooler with a re-purposed AC condenser coil and fan assembly. Just mist the water into the coils. It would comsume a lot of water though.

    • @wintech1969
      @wintech1969 2 หลายเดือนก่อน +1

      I have a discontinued well pipe in a 8x8 foot wellhouse. The newer well is 340 ft deep.
      Dunno about well house obsolete well.
      Does anyone think a car radiator would work? Or, would pressure from pump not be sufficient?

  • @jimlippi4001
    @jimlippi4001 2 หลายเดือนก่อน +1

    Depending on the water corrosion can be an issue. In my area untreated well water eats right through copper . It takes several years and the internal buildup also creates an insulator slowing down the transfer of heat. It's still an awesome idea . One that I still intend to try. 👍.

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน +1

      Thanks a lot! There is an option to make a closed loop by lowering the cooling radiator into your well. A closed loop will allow you to simply cool with coolant and not use hard water.

  • @Jon.......
    @Jon....... 2 หลายเดือนก่อน +4

    Great ... if you have an easily accessible cold, shallow well in your backyard.

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน +4

      There are many more options for using the land. For example, it is possible to bury pipes at a sufficient depth and pass coolant through them.

    • @kevingallineauii9353
      @kevingallineauii9353 2 หลายเดือนก่อน

      @@Doctor-Robo yep, 36" or so and it will be as cold as that well. The only other consideration would be how much pipe you need in the ground. The bigger the room to cool, the more pipe you need. I am sure there is some engineer who has written all this down. Geothermal systems use wells instead of buried coils because wells are usually more cost-effective to install. Someone considering geothermal has to consider that cost when installing a system. Having a well dug in the boondox is going to be a bit more expensive than a few more solar cells and an extra battery bank will be so, as with anything, the cost of installation and ongoing cost of ownership need to be considered.

  • @chrisdaniel1339
    @chrisdaniel1339 2 หลายเดือนก่อน

    You could upscale this with a copper coil in the well, insulating the lines from the well into the house, and use a larger heat exchanger in the house. Or you could use and old HVAC air handler unit from a house and instead of refrigerant you pumps the ground chilled water through the refrigerant heat exchanger and it would even have drip pans to catch the condensate and be easy to hook to a digital thermostat.

  • @johnnyllooddte3415
    @johnnyllooddte3415 2 หลายเดือนก่อน +3

    a/c 2 hours toinstall.. 100 dollars..
    ground loop .. 5000 dollar well.. one week.. build parts 1000 dollars 2 weeks..

  • @Kinetix2
    @Kinetix2 หลายเดือนก่อน

    Yes, a nice idea. But what about the minerals in the water that can corrode the radiator inside? You could make a closed circuit with a coiled copper pipe that will stay in the well, and only distilled water would run through the radiator and pipes. You have to replace the well pump with one that works in home central heating units. Also, a couple of holes in the concrete would let the hoses to pass without being squashed.

  • @luqmanrashid1651
    @luqmanrashid1651 2 หลายเดือนก่อน +3

    looking down a well is always unnerving

  • @NoahTheFacts
    @NoahTheFacts 2 หลายเดือนก่อน +1

    I love the idea, but a 600 watt window AC could also achieve that in a small shed then cycle for even less watts, so it’s probably only ⅓ the power.
    A solar panel powering a DC water pump and fans could be very interesting.
    If the well water is potable, check the water temperature and get it tested. Warming an active well can introduce bacteria.

    • @PinePondCTDevilsHopyard-fy3hj
      @PinePondCTDevilsHopyard-fy3hj 2 หลายเดือนก่อน +1

      Sure thing. With both the supply and return hoses full, the pump can be very small

  • @lamaseth
    @lamaseth 2 หลายเดือนก่อน +4

    If the temperature inside the water well is incredibly low, why not capture the cold air from the hole and channel it into the workshop? It could also go through an air filtration system.

    • @PinePondCTDevilsHopyard-fy3hj
      @PinePondCTDevilsHopyard-fy3hj 2 หลายเดือนก่อน +4

      May be too far and difficult to duct. Insulation on the water supply would be a plus.

  • @netsurfers9357
    @netsurfers9357 2 หลายเดือนก่อน +2

    Every home should have this!

  • @DivineMisterAdVentures
    @DivineMisterAdVentures 2 หลายเดือนก่อน +3

    EXCellent!!
    UNFORTUNATELY this requires a well, though maybe it would work with tap water.
    FORTUNATELY - I have ANOTHER ONE for you - EVAPORATION. If you use just 10 gallons a day - you can wipe 30 degrees off your internal temperature for that little shop - just sprinkle the roof on a timer twice an hour from about 8 AM until 5PM. This worked so well that after a single visit, my kid remembered it 20 years later and used it on his 35' RV.

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน

      Great idea - I'll definitely try it!

  • @BornFreeFilms
    @BornFreeFilms หลายเดือนก่อน +1

    Makes me wish I had a water table under me, but, I was already wishing that. lol

  • @CarlAyers-x8h
    @CarlAyers-x8h 2 หลายเดือนก่อน +5

    My electric bill running too small air conditioners in 14× 65ft Mobile home..40$ a month.

    • @kimmer6
      @kimmer6 2 หลายเดือนก่อน

      You definitely don't have electricity from Pacific Gas and Electric. They charge me 43 cents a kilowatt hour which rises to 52 cents a kilowatt hour about 2/3rds through the month.

    • @lolatu8255
      @lolatu8255 หลายเดือนก่อน +1

      @@kimmer6 That is insane! I will guess that you are in Kalifornia?

    • @kimmer6
      @kimmer6 หลายเดือนก่อน

      @@lolatu8255 Yup, the PRK...People's Republik of Kalifornia where insanity governs.

  • @tonytan0
    @tonytan0 2 หลายเดือนก่อน

    suggestion if the well is not being used for consumption. An idea would be to clean up the tubing and just dig a hole, add your container for your reservoir. That way you don't have an obstacle while mowing or have to look at the plastic tubing

  • @coachgeo
    @coachgeo 2 หลายเดือนก่อน +3

    may not be legal in many places... as in the water going back into the ground is now potentially contaminated. Especially after lot of use... AKA bacteria grows in the cooler/exchanger and your sending that right back into the water supply of those around you. Even if your worried about the laws.... treat the returning water via UV system or mist it into the air to fall on your land and let mother nature re-filter it. Might could introduce it back into ground via a leaky pond (with fountain to ward off mosquito) or buried poly drums with gravel to get the water to seep back into the ground. Now run all that on solar.
    Problem with above... now your more expensive than a cheap AC..... and even with paying monthly elec. Problem more expensive too.
    also minerals in the well water will very possibly clog up those coolers very quickly.

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน +1

      You are partly right, but I show ideas and execution. There are many options for execution, as you said - barrels with gravel and the like. You can even make a closed system with a cooling circuit inside the well and the water will not be affected at all.

    • @GlueTubber
      @GlueTubber 2 หลายเดือนก่อน +1

      just close the loop - put another radiator in the well to shed heat, and then cycle it back up to the shop.

    • @PinePondCTDevilsHopyard-fy3hj
      @PinePondCTDevilsHopyard-fy3hj 2 หลายเดือนก่อน +1

      A Michigan company Well Connect Geo makes units, they use well water and send the used water to the garden or a drywell.

  • @johnwang9914
    @johnwang9914 2 หลายเดือนก่อน +1

    New and unusual as in the ancient Romans did this with their country villas. Why do people insist in thinking they are so clever for reinventing the wheel.
    The ancient method of just having air tubes buried underground to cool the air and painting your chimney black to create an updraft hence pulling air through the buried air tubes into your house is also a passive system while your solution requires pumps and fans.

  • @EssGeeSee
    @EssGeeSee 2 หลายเดือนก่อน +10

    “Using the cheapest car parts” - like a welder.

    • @TobiArcher
      @TobiArcher 2 หลายเดือนก่อน +4

      Cheap parts, not cheap Tools.

    • @protorhinocerator142
      @protorhinocerator142 2 หลายเดือนก่อน +1

      You only need to buy the welder once. Then you could build kits like these for the neighbors and turn a profit.

    • @Romiman1
      @Romiman1 2 หลายเดือนก่อน +1

      or a 3D printer...

    • @chrism3839
      @chrism3839 2 หลายเดือนก่อน

      Yeah I get it, but its semantics, with woodworking skills and tools you could do the same thing, or 3d print it all with those skills and equipment. Many ways to skin the cat, if you don't have some other accompanying skills, DIY might not be the best option for you. Welders nowadays might be one of the cheapest options of all the things I just listed.

    • @protorhinocerator142
      @protorhinocerator142 2 หลายเดือนก่อน

      @@chrism3839 Have you ever used JB Weld? That stuff is pretty amazing.

  • @TheRealCheckmate
    @TheRealCheckmate 2 หลายเดือนก่อน

    WELL, I thought about doing the same thing, except the water in my well is about 24C or 75F. I concluded that it probably wouldn't do me much good, as the temperature in the hottest part of my house is typically ~88F on a hot day.

  • @TexasScout
    @TexasScout 2 หลายเดือนก่อน +4

    That’s real cute, but here in South Texas the ground temperature is 100°

    • @brusso456
      @brusso456 2 หลายเดือนก่อน +1

      “The temperature of the Earth down 20 or 30 feet is a relatively constant number year-round, somewhere between 50 and 60 degrees” F,

    • @TexasScout
      @TexasScout 2 หลายเดือนก่อน +2

      @@brusso456 that’s true, my water wells 400 feet deep in the water coming out of the ground is 72° year-round.

  • @thatfeeble-mindedboy
    @thatfeeble-mindedboy หลายเดือนก่อน +1

    For those few of us who no speaky de Celsius, according to him, that well water remains about 41 F in summer; his rig brought the inside temp. inside down to about 64 F. This might be possible in the UK, but here in S.Central Texas, this strikes me as implausible at best, but would certainly be better than nothing. Having THAT quantity of water at THAT temperature THAT close at hand is what makes this whole idea work. The Texas version of this would be need to include an existing well more like 200’ (61M) deep, an insulated shed with exterior (including roof) painted with that new IR-rejecting paint. It would be worth it to either position the shed under shade trees, or build a canopy over it with more of the overhang positioned over the south and west walls. Out here, ANY un-air conditioned structure just sitting out in the sun is going to quickly become a solar oven by the middle of the day no matter how much ventilation is available. A “breeze” of 105 F (50 C) air isn’t going to help. That means for at least 4 months out of the year, it is very unpleasant if not totally uninhabitable.

    • @Doctor-Robo
      @Doctor-Robo  หลายเดือนก่อน

      👍👍👍🤝

  • @Ayvengo21
    @Ayvengo21 หลายเดือนก่อน

    I think it could be optimized further. Instead of using big pump you could make closed loop with small pump similar for heating for water circulation. The advantage is much lover power consumption, you could use distilled water so your radiator won't die because of scale.

  • @terrellstewart4071
    @terrellstewart4071 2 หลายเดือนก่อน +3

    You made a swamp cooler not an a/c and instead of contaminating your well use an ice chest to circulate the water.😊

    • @melbayer596
      @melbayer596 2 หลายเดือนก่อน +3

      It is understandable why you might think this is a swamp cooler but swamp coolers work on a different principle. They evaporate water to cool the air. This one is using a heat exchanger to draw the cool temp out of the well water as the air is driven past the fins of the exchanger. The pump then sends that warmed water back into the well for recooling. Rinse and repeat... as others have mentioned it could even be modified to be a closed system unlike the swamp coolers that have to constantly have their water replaced as it evaporates. In dry climates swamp coolers are very effective to a certain temp in the high 90s after which they are useless because all they do then is blow hot air. The system would remain cool at any temp although the effective size would have to be modified based on the highest temps and the size of the room to be cooled. My 2 cents... hope this help.

    • @lolatu8255
      @lolatu8255 หลายเดือนก่อน

      Nope

  • @NeutralSmith
    @NeutralSmith 2 หลายเดือนก่อน

    Temperature goes down, humidity goes up.
    Maybe you could capture the condensation on the radiator and drain the water back outside (or at least to a place where it can't evaporate indoors again).

  • @adairjanney7109
    @adairjanney7109 2 หลายเดือนก่อน +6

    nah a small ac wont take no 3000 watts

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน +1

      Is that the only thing you didn't like about my idea?

    • @adairjanney7109
      @adairjanney7109 2 หลายเดือนก่อน +2

      @@Doctor-Robo I think its a great idea, just saying a small window ac might take 500-800 watts

    • @lawerancelanham
      @lawerancelanham 2 หลายเดือนก่อน

      ​@@adairjanney7109he said he only uses @300w though.

    • @janipulkkinen8065
      @janipulkkinen8065 2 หลายเดือนก่อน

      My full house ac is keeping the 240m2 at 22°c and the average electric input power for the past 22 days is 240,72 watts. I'm running a mitsubishi heavy industries twinscroll inverter split ac with larger than "normal" condenser and radiator.
      If intrested here is the math i used:
      22days x 24h = 528h
      Used electricity during last 22 days is 127,1kWh.
      127,1kWh/ 528h = 0,24072kW
      Conversion to watts:
      0,24072 x 1000 = 240,72W

  • @brunodiben
    @brunodiben 2 หลายเดือนก่อน +1

    Great video, I think you can enhance the system with peltier modules, such system will sit outside, use your refrigeration to cool/warm the side of the peltier you need to keep stable, and transfer to the inside via the other radiator

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน +2

      Great idea, I will definitely try this in my future videos! 🤖

  • @maretranquillity
    @maretranquillity 2 หลายเดือนก่อน +1

    You might be surprised to learn that many people don't have a wire feed welder, a shop, or a deep well, but good for you.

  • @cherylwin9364
    @cherylwin9364 4 วันที่ผ่านมา +1

    WOW THAT’S PRETTY COOL 😇👍🏾

    • @Doctor-Robo
      @Doctor-Robo  3 วันที่ผ่านมา

      Thank you. I'm glad you liked it.🤝

  • @offgrid2010
    @offgrid2010 2 หลายเดือนก่อน +1

    Good job!. I've always wondered how to make use of the colder temp's below ground but I never thought of accessing a well. Taking a compressor out of the equation is a really big deal!

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน

      Thanks a lot! I will be glad to see you again on my channel next time! 🤖

  • @alexlavertyau
    @alexlavertyau 2 หลายเดือนก่อน +2

    Maybe it's just the parent in me but I feel that well should be fenced off and also have an internal ladder in case someone falls in it.. that well is giving me the heeby jeebies... 😅

  • @algercomalekmalki7997
    @algercomalekmalki7997 หลายเดือนก่อน

    All the technologies used leaves me astonished ! 3D printers , thermometers etc…

  • @dus10dnd
    @dus10dnd 2 หลายเดือนก่อน

    This only works for cooling. It doesn't work for heating above that ambient temperature. In fact, when I state this... a lot of responses are that "but it will help!" No, not really. If you want a temperature above that, it impedes you. You still need a heat pump. Not, this system can be used to effectively turn an air source heat pump into a geothermal heat pump without all of the upfront costs. That will improve the efficiency a ton and decrease the operating costs. Plus, with all of the money that you say, you could buy some solar panels and run it from that!

  • @Joey-kv6qr
    @Joey-kv6qr 2 หลายเดือนก่อน

    I think 300 watts is still a lot of power being used. I have a 8,000btu Midea U shape window a/c and its using less than 200 watts once the room has been brought down to temperature its pretty much a mini split. With enough batteries and solar panels on the roof you can easily have limitless cooling as well but its nice to see this can be done with a water well. You can even dig and burry coiled copper water pipes and achieve almost the same just about anywhere on Earth. I would use a less powerful water pump and bring those watts down then you can easily use solar panels and batteries to run it 24/7

  • @missy3609
    @missy3609 2 หลายเดือนก่อน

    That is so cool, no pun intended, lol. Its awesome that you could use a 3d printer for some of the parts.

  • @kenibnanak5554
    @kenibnanak5554 2 หลายเดือนก่อน +1

    The first US White House air conditioner (19th century) used a similar water cooling system.

  • @Nonononono_Ohno
    @Nonononono_Ohno 2 หลายเดือนก่อน +2

    You don't need air conditioning anymore. All you need is an endless abyss, staring at you from the depths of the Earth.

  • @greggv8
    @greggv8 2 หลายเดือนก่อน

    Paint the outside of the shed with primer then gloss white paint, and insulate inside with foam board and your cooler will be able to keep it cool easier.

  • @gamingtonight1526
    @gamingtonight1526 หลายเดือนก่อน

    I have 4 small (18 inches tall) fans that have tanks for ice-water, ice cubes or ice-blocks, they are portable, and between all four they cool the living room where I spend most of my time. They cost £48 and connect via USB, so cost about 1p per hour per fan! It is easy to take one or two to the bedroom if it's going to be a warm night! Being small, they are very quiet!

  • @seja9031
    @seja9031 2 หลายเดือนก่อน +1

    To mnie się podobało, masz tego layka i suba bo wygląda na to że warto. Nawiasem geotermalne chłodzenie i geotermalne ogrzewanie a jednak nie stoją w opozycji i się wzajemnie nie wykluczają. Mnie puki co właśnie chłodzenie bardziej interesuje gdzie równierz ogniwa Poeltiera wydają się być przełomowe i to co do obu powyższych, ale jeszecze mi się to musi posklejać w głowie, kto wie co wyjdzie poza ekstra temperówką? ;) Myślę, i robię nie że nie robię, bo mam już własną elektrownię teraz ją sperpeciam bo jest mocno perpećna ale to taka moja słodka tajmnica, w magię skrzyneczki zaklęta bez wiedzy żywiołów czy ich żrudeł.

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน +1

      Bardzo się cieszę, że spodobał Ci się mój film. Będzie mi bardzo miło ponownie zobaczyć Cię na moim kanale! Dziękuję! 🤖

  • @GypsyPriest
    @GypsyPriest 2 หลายเดือนก่อน

    THIS IS GREAT!!! Now if I could just find me a nice 12 meter deep well.

  • @sreed16
    @sreed16 2 หลายเดือนก่อน

    I built this for my computer: It's a 8' tall Water Bong. Hot water falls from the top.. hot air gets vented out of the top.. hot water drops down into the 'well' reservoir which has hundreds of salt water aquarium filter balls. It just uses a water pump, truck oil cooler, and a couple 125mm computer fans.

  • @reinermbivz3278
    @reinermbivz3278 หลายเดือนก่อน +1

    Was für ein Riesenaufwand mit Schweißgerät und 3D Drucker und dann werden am Schluß nur noch 7000 Liter Wasser im eigenen Brunnen gebraucht. Wirklich etwas für Jedermann 😎

    • @Enno79
      @Enno79 หลายเดือนก่อน

      Jup zumal moderne inverter Klimaanlage wie die neue Midea PortaSlit gezeigt haben das sie auch nur im Schnitt 350W benötigen wenn man Sie nicht auf volldampf laufen lässt. Die hier gezeigte Pumpe hat ja auch schon 200 Watt und die Lüfter ziehen auch noch was.

  • @jrgordon47
    @jrgordon47 หลายเดือนก่อน +1

    Yup all ya need is a 60 meter well, that's still wet, and not used for domestic water... and you're in the breeze...

  • @marcoaurelio296
    @marcoaurelio296 2 หลายเดือนก่อน +1

    Excelente!! Una genial idea! Voy a aportar un dato: Por más que se abra la tapa del pozo, el aire caliente del exterior no ingrasará nunca porque no hay posibilidad de circulación y por una cuestión de menor densidad del aire caliente exterior. Y por el contrario, el aire adentro del pozo no sale porque es más denso que el aire en superficie.

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน

      ¡Muchas gracias! Pero también existe una ley de la física, como la difusión en los gases. ¡Vuelve a mi canal, siempre estaré feliz de verte! 🤖

  • @stuartbailey6201
    @stuartbailey6201 2 หลายเดือนก่อน

    Good grief “ I love it when people do smart stuff and then share it “ absolute brilliance.

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน

      Thanks a lot. Come back to my channel, I will always be glad to see you here. There are many more interesting videos here! 🤖

  • @dixter1652
    @dixter1652 2 หลายเดือนก่อน

    we have geothermal... my entire utiliity bill is right around $50/month and that includes electric/water/sewer... so thats not too bad... I do like your design... good job

  • @CIS101
    @CIS101 2 หลายเดือนก่อน

    This is probably the best solution all around. He could easily air condition the entire house.

  • @DavidPsCaddy
    @DavidPsCaddy 2 หลายเดือนก่อน +1

    Excellent Idea!!! Cooling for a small fraction of the price of a normal A/C system!!! You've basically made a 'GeoThermal' system for penny's!!! I wish I had a well I could use where I am ... 😞True Genius on a budget ... 🙂

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน

      Thank you so much my friend! I'm glad you liked my video. Come back to my channel, there are still a lot of interesting and unusual ideas. I will always be glad to see you. 🤖

    • @snakeinthegrass7443
      @snakeinthegrass7443 2 หลายเดือนก่อน

      New radiators.$ Welder.$ Fans.$ 3D Printer.$$ A deep well with a huge cover on it.$$$ The experience needed to do this...priceless.
      AC units in the windows and solar panels on the roof. In the northern climate of the US, that's all that is needed. In the South, more AC and more solar panels.

  • @momos5585
    @momos5585 2 หลายเดือนก่อน

    Depending on the TDS of the well water, you will liking over time develop mineral deposit in the coils resulting in loss of heat transfer. But its probably still advantageous to run this if its your only option. Good job.

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน

      The TDS of well water is excellent. Thanks a lot! Come back to my channel, there are many more interesting videos! 🤝

  • @KentuckyRanger
    @KentuckyRanger 2 หลายเดือนก่อน

    I always thought, that this would be an awesome project, for water cooling a PC, but a room?
    Interesting!

  • @chetmarcotti4953
    @chetmarcotti4953 2 หลายเดือนก่อน

    Really nice presentation and good use of common tools and parts to reach your goal. Just awesome. Wish I had a well at this point. Thanks

  • @TaterPS
    @TaterPS 2 หลายเดือนก่อน +1

    What is the humidity like? Humidity tends to make most people feel more uncomfortable than higher temperatures.

  • @davidjondoh8671
    @davidjondoh8671 2 หลายเดือนก่อน +1

    Great idea. But the giant and deep hole in the ground filled with water looks like a big safety concern, especially to curious children.

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน +1

      Thank you! My well is tightly closed with a heavy lid that cannot be opened. Everything is safe. 🤖

  • @ljalpena3552
    @ljalpena3552 หลายเดือนก่อน

    I used an automotive used radiator in my window with a box fan ,Run water through it. Cooled house nicely. That was 50 yrs ago.

    • @Doctor-Robo
      @Doctor-Robo  หลายเดือนก่อน

      👍👍👍🤝🤖

  • @AF-bv7tb
    @AF-bv7tb หลายเดือนก่อน

    Great work...👍
    You guys... _you three_ *_in particular..._*
    *ARE* indeed having a positive effect...!!! 👍
    *_Thanks for your work...!_*

  • @greenwolf401
    @greenwolf401 2 หลายเดือนก่อน +1

    Now just figure out a way to collect all of the condensation that is sure to follow. Use the collected water for gardening or filter it for human use. If you don't want to chance drinking it, then use for doing laundry, dishes, bathing or the toilet.

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน

      Yes, condensation is not shown in the video, but it appears during system operation. I am already making a humidifier from this condensate to humidify the room. 🤖

  • @antibrevity
    @antibrevity 2 หลายเดือนก่อน

    Excellent project and experiment. Condensation will become a problem except in the driest of conditions and the well water temperature will likely increase as the weeks pass unless there's an underground flow of groundwater that keeps cycling water through the well. It's still a great setup and it would be interesting to see how it performs over a longer period and how you deal with the condensation. Thanks.

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน

      Thank you too! Yes, condensation is not shown in the video, but it appears during system operation. I am already making a humidifier from this condensate to humidify the room. The water will not heat up in the well. I have an underground river and the water level is renewed constantly. The volume of the well is 7 tons of water and it is constantly renewed. Come back to my channel again, there are still a lot of interesting videos)). I will always be glad to see you. 🤖

  • @RuFiOxOG
    @RuFiOxOG 2 หลายเดือนก่อน

    I dug my own well a few years ago and have been meaning to set something like this up!!

  • @ltgood
    @ltgood 2 หลายเดือนก่อน

    Great project. A well 12m deep is not an endless abyss? The hoses are crushed which will inhibit water flow and insulating the hose will increase efficiency. I like it a lot tho.

  • @AutoNomades
    @AutoNomades 2 หลายเดือนก่อน +2

    Nice system, I have tought about doing the same, but i'm a bit scared of polluting the water quality of the underground spring by heating the water, wich original temperature allows it to conserve well..... What about starting first to insulate well the cottage with load bearing strawbale walls woated with earthen plasters, then add a little more freshness (if it is still needed)....?

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน +1

      My water has groundwater circulation, I have a subterranean river underground. The volume of the well is about 7 tons of water. Water has a very high heat capacity and it is almost impossible to heat it even by 1-n degree Celsius. It is also possible to make a closed circuit with a cooling radiator in the well and the system will become hermetic. Thank you. Come back to my channel again, I will always be glad to see you! 🤖

    • @AutoNomades
      @AutoNomades 2 หลายเดือนก่อน

      @@Doctor-Robo Ok good to know, thanks for your explaination ! :) Would it still be interesting to moove air in place of water ? (I was thinking to use thermosyphon with a solar chemney pulling hot air from the room, bringing cold air from the well pipe ...

  • @straightopoint
    @straightopoint หลายเดือนก่อน

    This is great for someone that has a well. Not feasible in a high rise apartment building

  • @theclearsounds3911
    @theclearsounds3911 2 หลายเดือนก่อน

    A small space like your shop can easily be cooled by a 5,000 BTU air conditioner for less than $200, and its power consumption should be only about double what yours is, NOT 10 times! However, if you don't have a well, it will cost $thousands to drill one. You'll never make up that cost compared with just buying a cheap air conditioner. Scale this up to a full size house, and the well starts to make sense.

  • @zer0tzer0
    @zer0tzer0 2 หลายเดือนก่อน

    You could improve the efficiency of the system by venting the hot air to the outside, however given the temperature you've achieved it seems unnecessary under those conditions..

    • @Doctor-Robo
      @Doctor-Robo  2 หลายเดือนก่อน +1

      There is no point in letting the hot air outside, it circulates inside the room and cools down. With each air revolution - the air portion has a lower temperature than it was and is cooled down even more. Thank you. Come back to my channel again, I will always be glad to see you! 🤖

  • @stanjohnson7849
    @stanjohnson7849 20 วันที่ผ่านมา

    Some comments say that they don’t have cold water from well… but tap water will work good too…. But not good in high humidity, but in desert 🌵 you should be able to drop the temperature almost 30* f Go for it

  • @mlangfordoutdoor
    @mlangfordoutdoor หลายเดือนก่อน

    Always wanted to watch a welders arc

  • @eve6936
    @eve6936 หลายเดือนก่อน +1

    Dr. Robo, please include “a deep Well “ to the list . It’s hard to find in stores. But thanks.

  • @Sb129
    @Sb129 2 หลายเดือนก่อน +1

    During the Arizona summer, Even the ground is hot. Turn on the 'cold' tap and it comes out warm. Only the water in the pipes with the cool house is cold. Lol.

  • @SkylosSobaka
    @SkylosSobaka 2 หลายเดือนก่อน

    Its pretty well established that open loop geothermal is by far the most energy efficient heating/cooling system - unfortunately, it costs $20K-$50K to create such a well if you don't already have one...

    • @Diviance
      @Diviance 2 หลายเดือนก่อน

      DXG is very close in efficiency to open loop and, well... way more affordable if you don't have easy access to groundwater (or the local government bans open loop stuff like that).
      The efficiency gains are kind of offset by the additional well pump and the increased maintenance costs of open loop.

    • @SkylosSobaka
      @SkylosSobaka 2 หลายเดือนก่อน

      @@Diviance True story. Closed loop is very close to open loop in efficiency, and is more affordable. I'd probably have to spend 5-10K in excavation and another 5-10K in heat exchanger installation though, bringing me perilously close to open loop build cost. And some offset for maintenance, but more in the 'your refrigerator won't last forever without maintenance" sort of way, not in a "you have to do something every month" sort of way.