How to repair solar Inverter & charger 5000 Watt: White Smoke out of the inverter

แชร์
ฝัง
  • เผยแพร่เมื่อ 23 ม.ค. 2025

ความคิดเห็น • 29

  • @crymeforeverlo3402
    @crymeforeverlo3402 ปีที่แล้ว

    احسنت صنعا..عمل مرتب وفي معلمية واضحة.جزاك الله خير..

  • @Apo5308
    @Apo5308 2 ปีที่แล้ว +1

    Thank you for your informative video! You changed all 4 capacitors - for timing reasons, I think?

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  2 ปีที่แล้ว +1

      You are right
      Because we were not sure of the real cause of the damage
      Of some capacitors
      We decided to replace them all

    • @Apo5308
      @Apo5308 2 ปีที่แล้ว +1

      @@ALayoubiMaintenanceCenter Thank you! You could start video with a picture of the inverter table (on the side wall) - the type and all parameters will be visible - just for info. Thank you very much, again!

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  2 ปีที่แล้ว +1

      I hope you will forgive us
      And you are all right
      But we were sometimes forgetting to show the technical specifications of the device
      We promise to show the special data for each inverter that we tube it later

  • @dama054
    @dama054 2 ปีที่แล้ว +1

    Another really good video thanks

  • @Dc_tech386
    @Dc_tech386 ปีที่แล้ว

    I realize that overload created 10 time the stress on the igbt when the pwm reduces it’s duty cycle I don’t understand the relationship between the duty cycle and pluse current at shortcircuit or overloaded I use a thyristor to turn off the spwm cord because the comparator don’t turn off sometimes causing all igbt to blow it’s gate and dye

  • @mokammalhaque
    @mokammalhaque 2 ปีที่แล้ว +2

    Great job 👏

  • @VM-Ufology
    @VM-Ufology 2 ปีที่แล้ว +3

    great

  • @SylwerDragon
    @SylwerDragon 2 ปีที่แล้ว +2

    Nice video. I think you said something about 'capacitors possible damaged by heat from bottom pad' ..I expect you were talking about that missing pad (heat is going to chassis with it) i did see on some of your videos.. but i think you didn't install it..I understand it wasn't there from start..but maybe it could improve results..maybe..

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  2 ปีที่แล้ว +2

      you are right
      But we didn't forget to put the pad
      We don't have one and we couldn't find one because it has special specifications
      And we explained that the factory did not use a one (factory defect)
      It is a manufacturing defect

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  2 ปีที่แล้ว +1

      We provide free content about manufacturing defect ,We hope manufacturers will follow our channel.. The content may be useful for them And maybe soon the content for manufacturing defect will be paid

  • @MohammadAdnanElectronics
    @MohammadAdnanElectronics 2 ปีที่แล้ว +2

    brother which meter do you used?? please

  • @MikeMcgaskey
    @MikeMcgaskey ปีที่แล้ว

    does the warranty cover this

  • @theheathkitshop2424
    @theheathkitshop2424 2 ปีที่แล้ว +1

    I've spent a lot of time working on my service bench, and For some strange reason, I find watching your guys work on these broke inverters interesting. I have noticed a couple of things, one, no matter the make or model, they are damn near the same inside. Apparently there is one or two companies that make these and then private label them. Two, I never see any schematics so I'm guessing it's shear repetition that allows repair without schematics (and the fact they are almost all the same design) And lastly, how much time delation is used? Does a 30 minute video compress two days of trouble shooting? Or do the repairs appear in real time?

  • @aliislam1479
    @aliislam1479 2 ปีที่แล้ว

    Sir please make a video on fault 06 hybrid inverter 5kw.

  • @falahbo_amar4092
    @falahbo_amar4092 2 ปีที่แล้ว +1

    استمر جزاك الله كل خير

  • @aliislam1479
    @aliislam1479 2 ปีที่แล้ว

    Output voltage is too high ...but the igbt is not sorted.

  • @rcinfla9017
    @rcinfla9017 2 ปีที่แล้ว +1

    63v rated caps have very little design margin for a 48v inverter. 60v equalization charge + battery cable inductance voltage ringing will exceed ratings of caps. Small gauge battery cables increase ripple voltage on caps increasing internal heating.

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  2 ปีที่แล้ว

      You are right my dear friend
      We replace damaged items with the same type
      We do not modify.
      Sometimes we don't show the edit.
      This inverter has weak components..
      In the future, we will be showing videos for membership friends to the channel
      And we appear the modified compmnents
      and spot to weak components..
      This must be 80v

  • @AqibAli-un4ul
    @AqibAli-un4ul 5 หลายเดือนก่อน

    nice