Generator Automatic start with ATS (Automatic Transfer Switch)

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ส.ค. 2024

ความคิดเห็น • 38

  • @gbmelectricalairconditioni9845
    @gbmelectricalairconditioni9845 3 หลายเดือนก่อน

    thanks po sir sa video mo very useful po sir.

  • @electricalworksstudio3558
    @electricalworksstudio3558 2 ปีที่แล้ว

    Informative video Sir para sa mga baguhan p lng na electricians..

  • @antonioamata9101
    @antonioamata9101 5 หลายเดือนก่อน

    Thanks po sa kaalaman..

  • @jonelrito477
    @jonelrito477 11 หลายเดือนก่อน

    Salamat po idol sa tutorial, God bless po

  • @Chill-GamingYT
    @Chill-GamingYT ปีที่แล้ว +2

    kolang po sa safety sir
    paano kung naka connect na sa ats
    tapus ang generator naka on na tapos bigla nag black out
    mag auto start na ang genset mo galing sa ats mag contact na naman ang timer ng start command at naka andar na
    walang interlock sa ats to generator
    kung naka set ng auto yung ats sa mdp
    tapos sa contact galing relay at timer to generator start pero kung naka manual pina andar ang genset at may nag manual sa ats sa mdp mag ka double start ang starter
    meron akong interlock from alternator kapag naka andar na hindi na pwede mag command ng start at kapag bumalik na normal power mag command ang ats ng cool down o off signal with timer bago mamatay ang generator
    kung sakali failure to first start meron din follow up until 3 to 5 times starting contact
    mag interlock ang timer sa alternator signal na omandar na at tigil na ang pag start
    off signal to key switch off by jog stop after time to off during cool down

  • @xmatvlog5648
    @xmatvlog5648 2 ปีที่แล้ว

    Great explanation great tips ito

  • @mariejoycacay4840
    @mariejoycacay4840 2 ปีที่แล้ว

    Salamat po sa dagdag kaalaman God bless po

  • @cezar2606
    @cezar2606 ปีที่แล้ว +1

    yung po sanang automatic stop. kasi po pag tulog kana tuloy parin takbo ng genset mo

  • @adrianbabaran8661
    @adrianbabaran8661 2 ปีที่แล้ว

    Maraming salamat boss master!

    • @adrianbabaran8661
      @adrianbabaran8661 2 ปีที่แล้ว

      Sir, pano naman yung pag shutdown sa genset pag bumalik ang normal power. Thanks in advanced!

  • @mamichielcomaling
    @mamichielcomaling 5 หลายเดือนก่อน

    Good job po, may itatanong Lang.. Pag may currente na uli ang grid line paano mag shutdown ang engine ng generator?hindi Ata nasama sa iyong diagram...

  • @kensombise504
    @kensombise504 ปีที่แล้ว +2

    Master clarification lang. Kapag bumalik na po ba yung normal power automatic din ba maooff yung generator? ang naintindihan ko po kaso is yung basic starter circuit lang ang mag di-disingage kapag balik ng normal power?

  • @artartmg6191
    @artartmg6191 2 ปีที่แล้ว

    God bless po

  • @danilocabigaojr3827
    @danilocabigaojr3827 หลายเดือนก่อน

    Master yan pubang additional control panel eh available na mabibili sa market salamt po

  • @monseratmeneses1197
    @monseratmeneses1197 ปีที่แล้ว

    Dapat may cooling off ang shutdown ng genset. Kahit ilan segundo lang.

  • @Chill-GamingYT
    @Chill-GamingYT ปีที่แล้ว +1

    pwede ba kokoha tayu ng signal normally open contact series to key switch supply para pag bumalik ang power e off nya ang generator tru contact disconnection naka sa additional timer to cool down at pasa sa timer naman to off contact sa key switch?

  • @juniloencendencia5188
    @juniloencendencia5188 6 หลายเดือนก่อน

    Sir paano pag nasira ang timer coil or 12v battery while umaandar ang generator? Hindi Kaya delikado ang starter gear natin?

  • @ronygonzaga6217
    @ronygonzaga6217 หลายเดือนก่อน

    Good Day, if the normal power return how do to stop the generator? thank you

  • @manuelroxas3005
    @manuelroxas3005 2 ปีที่แล้ว +1

    Sir tanong Lang if 400 amprs ang MDB ko ganun din ba gagamitin Kong amprs Para sa ATS ko manual or automatic na ATS.. Salmat sir sa sagot

    • @masterjoeelectrical
      @masterjoeelectrical  2 ปีที่แล้ว +1

      Tama po master para lhat ng load mo sa normal ay magagamit din sa emergency dapat ang generator ay kayang dalhin ang 400a load merry Christmas God bless

  • @jackyianpo1584
    @jackyianpo1584 2 ปีที่แล้ว +1

    Sir prang hindi mag off yung starter after cranking kasi yung senseing ng relay nasa main grid lang. Prang kailang ng isang relay sa output ng genset to sense na meron ng power at mag cutcut yung starter. Salamat sir very interested sa ganitong schematic.

    • @orlandoreyes4170
      @orlandoreyes4170 2 ปีที่แล้ว +1

      Time relay sir ilagay mo sa normally close Yung papuntang trigger Ng starter,iset mo po kung ilang seconds mo gusto mag crank pag nag power up po Yung timer mag o open npo Yung normally close Kaya po ma I stop Yung cranking. God bless po.☝️☝️☝️🙏🙏🙏

    • @samtrevtorsumabat2648
      @samtrevtorsumabat2648 2 ปีที่แล้ว

      sa output dapat ang sensing relay...tapos maganda ay may repetitive na cranking control, say every 15 sec just in case hindi makuha sa isang cranking ang pag andar ng makina...just a thought lang po...mabuhay kayo

  • @saturninoiiisaban3016
    @saturninoiiisaban3016 9 หลายเดือนก่อน

    Sir saan e top ang 4wire ng ats.may code na r81 r82 r84 r85 pa puntang generator.

  • @alfredcruz7028
    @alfredcruz7028 2 ปีที่แล้ว +1

    Good day! Sir San po sir yung kill swicth ng generator di po yata na mention Sa diagram in terms na bumalik si power grid activate yung kill swicth para mamatay yung generator salamat po!!

    • @masterjoeelectrical
      @masterjoeelectrical  2 ปีที่แล้ว +1

      God bless po master wala po tayong kill switch sa aking design kasi automatic start lang po yon.thanks for subscribing hayaan mo next time consider natin yon

  • @siargaoadventures9913
    @siargaoadventures9913 ปีที่แล้ว

    Master pag nag automatic start na ang generator run few hours tapos babalik na ang normal power mag off ba ang generator automatic din ang close

  • @wolfengott
    @wolfengott ปีที่แล้ว

    mag off ba sya? kasi yung starter lang naman mawawalan ng power pag bumalik ang normal power?

  • @mcmoto2546
    @mcmoto2546 9 หลายเดือนก่อน

    may kill switch pa sa genset

  • @Chill-GamingYT
    @Chill-GamingYT ปีที่แล้ว +1

    paano patayin ang generator pag bumalik na ang normal power

  • @lucitapardillo3393
    @lucitapardillo3393 ปีที่แล้ว

    san yung dry contact iconnect ..sa control ng genset

  • @manuelroxas3005
    @manuelroxas3005 2 ปีที่แล้ว

    Sir applicable ba sa lahat NG portable generator Yan.. At Tama Lang ba Un manga amprs sir.. Salmat sa sagot

    • @masterjoeelectrical
      @masterjoeelectrical  2 ปีที่แล้ว +1

      Yes po master merry Christmas GOD bless

    • @manuelroxas3005
      @manuelroxas3005 2 ปีที่แล้ว

      @@masterjoeelectrical sir kahit ba sa malalaki na Gen.. 600kva applicable din b Un control for automatic start.. Txn sir

    • @sersiobordios
      @sersiobordios ปีที่แล้ว

      @@masterjoeelectrical Sir dapat po may normally closed relay contact pa djan sa key switch para pag power outage siya yong mag on ng power at accessories ng genset engine at pag balik naman ng Grid power ay yon din ang mag ca cut ng connection ng key switch area para mamatay ang makina ng genset.

  • @rommelculangen5073
    @rommelculangen5073 2 ปีที่แล้ว

    MAS MAGANDA kung may actual sna sir,,

  • @dhenziorolpu9026
    @dhenziorolpu9026 2 ปีที่แล้ว

    Paano eestart ats ung generator ng automatic