15 Coil On Plug Testing

แชร์
ฝัง
  • เผยแพร่เมื่อ 13 ก.ย. 2024
  • Video 15 of 22 in the Logical Troubleshooting of Automotive Electronics program: • Logical Troubleshootin...
    * Next: Primary and Secondary Ignition • 16 Primary and Seconda...
    * Previous: Electrical Measurements • 14 Electrical Measurem...
    * View our entire library: / @deadondiagnostics5502
    COURSE MANUAL (57 MB): deadondiagnost...

ความคิดเห็น • 2

  • @alexmessina3383
    @alexmessina3383 4 ปีที่แล้ว +1

    Ok, but why the high current in the primary with a normal looking ramp indicating inductance. It should indicate a shorted coil, but the normal ramp and inductance says otherwise. No spark indicates and shorted secondary. But turn on oscillations show in the primary and there's not firing or spark line. This looks like a confusing pattern to me. Be interested in anyone's explanation

    • @abdul-kabiralegbe5660
      @abdul-kabiralegbe5660 10 หลายเดือนก่อน

      I think the coil is going bad: low resistance on the primary and secondary. I suspect the heat of normal operation has begun to break down the insulation on the windings causing a drop in resistance in both primary and secondary coils.