  • Got a call for a reefer unit that quit running and has a high pressure code active here’s a diy on understanding what that means and how to repair or bypass

ความคิดเห็น • 87

  • @tonymel8235
    @tonymel8235 ปีที่แล้ว +1

    I do have the same issue. I’ve got the sensor in a dealership. How do you replace the sensor? I know there’s a high-pressure in there.

  • @ronalda5252
    @ronalda5252 2 ปีที่แล้ว +1

    my friend I have a question for you what is the high and low pressure what is the pis in supra 960,860,660 I will wait for your prompt response thanks

  • @kirkblosser5141
    @kirkblosser5141 ปีที่แล้ว +1

    just bought a reefer truck with a carrier supra 760 on it and when I got up top to look at unit I noticed it had no top cover is the normal ? or is the cover missing.?

  • @alvarofuentes8397
    @alvarofuentes8397 2 หลายเดือนก่อน

    I have high discharge code changed hp switch change condenser fix break on the hp switch hardness and still the compressor wont engage

  • @eiondaley2821
    @eiondaley2821 3 หลายเดือนก่อน

    I have a 660 starter code. Unit does not at times. I can use power probe to start. I know starter is good. Need help.

  • @kkcast3631
    @kkcast3631 2 ปีที่แล้ว +1

    Hello, great content. How much should discharge pressures fluctuate?

  • @chrisfrederick42
    @chrisfrederick42 2 ปีที่แล้ว +1

    I have a carrier transcold reefer unit and it says high discharge pressure I've cleaned the condenser and the fan is working the temp is up and down 338 up to 441 then it goes down to 320s

  • @EricA-zy8gj
    @EricA-zy8gj ปีที่แล้ว +1

    I have a thermoking 880s with the same issue, high discharge pressure but no other codes. Mechanic changed belts but now he said a relay on the circuit board is out. Is that related at all to the high discharge issue?

  • @kirkblosser5141
    @kirkblosser5141 ปีที่แล้ว +1

    my 760 just had the high pressure came on and when I got up in the unit its belts are very loose not sure if that would cause the warning to come on, also I notice when I am am driving down the road no warning comes on, any ideas

    • @StickShiftRacing
      @StickShiftRacing  ปีที่แล้ว

      yes if the compressor is slipping on the belt it will cause the issue

  • @HeRo_123
    @HeRo_123 10 หลายเดือนก่อน

    Thanks for always sharing solutions here

  • @TonyBabineaux-nd3kv
    @TonyBabineaux-nd3kv 4 หลายเดือนก่อน

    What’s pressure rating on that mini pressure switch? reftech I see it’s 404a ref. We usually have a 450psi cutout on commercial building units

  • @dubmatic7011
    @dubmatic7011 ปีที่แล้ว +1

    Whats up Boss I got a question? I did my reefer pre trip test on my unit and it failed because it says that I have a code P-195 low suction pressure can you give me some insight on what could I could do or check for.

    • @StickShiftRacing
      @StickShiftRacing  ปีที่แล้ว

      it has a leak low suction pressure means it has run out of Freon find the leak repair and refill

  • @aaronmorrow00
    @aaronmorrow00 ปีที่แล้ว

    Is there a alarm code AL5 for a carrier supra 860. Cant find nothing about it online. Unit wont even try to start just goes straight to alarm code buzzer when i turn the micro processor ( in cab control box) on.

  • @patricioaguayo9088
    @patricioaguayo9088 3 ปีที่แล้ว +1

    Those were always a back breaker. Good job

    • @StickShiftRacing
      @StickShiftRacing  3 ปีที่แล้ว +1

      true that climbing up these things wear on ya

    • @patricioaguayo9088
      @patricioaguayo9088 3 ปีที่แล้ว

      @@StickShiftRacing it is always nice to share knowledge. I try and share all I know to whoever listens.

  • @abicamiloficial5123
    @abicamiloficial5123 ปีที่แล้ว +1

    Hi,can anybody tell me where is located it the glow plugs in a carrier reefer unit?im trying to replace them,my reefer unit is not starting...

  • @jurgencr1
    @jurgencr1 2 ปีที่แล้ว +1

    Hey man i have a 750 supra .. is throwin hot engine code and shuts off i checked and that sensor you talked about is broken would that be part of this problem thank you for your time

  • @jeffpupillo9639
    @jeffpupillo9639 ปีที่แล้ว

    Have a High pressure sensor code on a thermo king v-520. I notice belt is loose andvthe unit goes on and off.....could the belt be throwing that code?

  • @manolomonterroso3121
    @manolomonterroso3121 ปีที่แล้ว +1

    Hi my friend, I have a Supra 950 why is that all 4 fans are not working……?

  • @olivercortez3986
    @olivercortez3986 2 ปีที่แล้ว +1

    He man I have a question what it’s the alarm means check refrigerant system?

  • @rmitch15
    @rmitch15 ปีที่แล้ว +1

    Hey thanks for showing videos like this, helpful. I have a carrier supra 660 which keeps shutting down whether I come to a hard stop or the truck is turning. I've checked the display unit even replaced and ruled that out. Checked for frayed wires and taped some up but same. Belts are fine, oil etc. Also replaced the speed solenoid and fuel pump. My buddy told me it could be the oil pressure sensor so I bypassed that to test and now the unit shuts down more frequently and throws an alt aux code which I suspect is due to the bypass. Could that also be indicating that the alternator is bad. My buddy is also suggesting replacing the oil pump. Have taken it to the dealer but nothing yet. Any thoughts

    • @StickShiftRacing
      @StickShiftRacing  ปีที่แล้ว +1

      Only way it will through an alternator code is if it’s not working via belt loose or alternator dead … looks like you’ve already diagnosed it good job now change that alternator

    • @rmitch15
      @rmitch15 ปีที่แล้ว

      The alternator voltage truck off on the cab command is showing 13.5-6v is that about right or should it be higher? Truck on its 13.9v but that I guess is the reading from the truck itself

    • @rmitch15
      @rmitch15 ปีที่แล้ว

      Thank you

    • @rmitch15
      @rmitch15 ปีที่แล้ว

      Changed the alternator but the same issue, the voltage is slightly higher but it didn't fix the problem.

    • @rmitch15
      @rmitch15 ปีที่แล้ว

      It seems I have the issue resolved. The alternator was under performing yes and was replaced. But I also saw that there were constant bubbles in the fuel pump from loose fittings and there was a short in one of the connectors inside the panel. Both of these were fixed and the issue I was having with the unit stalling and shutting down when I turned left and right, or when the vehicle stopped or took off. After fishing this the defrost when it ran was not completing and kept restarting. Cleaning the contacts on the switch solved that. Hope this helps someone. Thanks for the encouragement that lead to solving my issues.

  • @dubmatic7011
    @dubmatic7011 ปีที่แล้ว +1

    I have a carrier25 Utility 3000R Multi-Temp would code A17 be related to this and is there a way to bypass it?

  • @albertflores8439
    @albertflores8439 6 หลายเดือนก่อน

    Is a good video tip!!
    I'm already having about the same trouble with a supra 860!! I already replaced the discharge sensor pressure and the 3 way valve cause they were defective;but the alarm still showing up on the display!!! I already nade a by pass on the hi press sensor on the compressor!!! I can't realice what it coulde bw the reason!! someone could give me a hand with this problem??

    • @keonsmith1143
      @keonsmith1143 13 วันที่ผ่านมา

      Did you find out what your issue was I'm having high compressor discharge and I'm thinking the fan clutch relay is not working properly it does high pressure if I set the unit 7 degrees or lower

  • @dubmatic7011
    @dubmatic7011 ปีที่แล้ว +1

    Thanks Boss appreciate that man!

  • @kirkblosser5141
    @kirkblosser5141 ปีที่แล้ว +1

    never mind just saw a video you had where the unit was open on top. that's crazy. how can that be good.. lol well I will see how it does. has 4000 hours on the unit and still runs . what's good hours for a unit like this. thanks

    • @StickShiftRacing
      @StickShiftRacing  ปีที่แล้ว +1

      4000 ain’t bad I’ve had em run for 15k plus without major issues and yeah they don’t come with top covers they have to breath!

    • @kirkblosser5141
      @kirkblosser5141 ปีที่แล้ว

      @@StickShiftRacing thanks

  • @ebqtransportllc7514
    @ebqtransportllc7514 2 ปีที่แล้ว +1

    Hey Boss good video. Im having a Hi Press message coming on my supra 960. Paid to get an oil change, filled with freon and they "Tighten" a belt. Before I left tech said I can use a new fuel pump. Used about 10 times no problem... First tried to turn on but would get CNF1 TV message. Disconnected and reconnect fuel pump and started up. So I changed fuel pump but now im getting the HI PRESS message.. What do you think?

  • @deontetoliver1953
    @deontetoliver1953 3 ปีที่แล้ว +1

    I’m getting a Eng Hot code and my Reefer shuts off. I have the same unit. Any suggestions on what it could be?

    • @StickShiftRacing
      @StickShiftRacing  3 ปีที่แล้ว

      Many reasons could be the issue first check the coolant level is it full? have you purged it? Is the belt on the water pump… that’s the belt on the front of the engine nearest the front of the truck. Is the thermostat ok? Any leaks? And lastly it’s got a blown head gasket

  • @thomasschuneman9394
    @thomasschuneman9394 2 ปีที่แล้ว +2

    Dude, great video... I got a carrier supra 750...I want to plug it in when I'm not on the road... How do I get the specs to do this?? Please contact or help me...thanks..

    • @StickShiftRacing
      @StickShiftRacing  2 ปีที่แล้ว +1

      need to give me a call during the day 6155688895

    • @thomasschuneman9394
      @thomasschuneman9394 2 ปีที่แล้ว +1

      @@StickShiftRacing I'll call soon and thank u

    • @thomasschuneman9394
      @thomasschuneman9394 2 ปีที่แล้ว +1

      @@StickShiftRacing it's Monday 11-22 here in Knightdale NC. Trying to contact you

    • @StickShiftRacing
      @StickShiftRacing  2 ปีที่แล้ว

      @@thomasschuneman9394 call me

  • @AllDieselofTexas
    @AllDieselofTexas ปีที่แล้ว +1

    hey boss great video. Where can I write to you about a Carrier unit i am having trouble with its on a refeer.

  • @coltonmoore1
    @coltonmoore1 3 ปีที่แล้ว +1

    Could the unit being low on refrigerant also cause the unit to build high pressure? I’m talking 55psig suction and 425psig head pressure.

    • @StickShiftRacing
      @StickShiftRacing  3 ปีที่แล้ว +1

      No high pressure can only come from faulty sensors, gate valves, or to much Freon

    • @coltonmoore1
      @coltonmoore1 3 ปีที่แล้ว +1

      @@StickShiftRacing the reason I ask is because the oil sight glass is showing extremely low/empty, and the dead pressures are around 80psig on both sides. What do you think? Restriction?

    • @StickShiftRacing
      @StickShiftRacing  3 ปีที่แล้ว

      @@coltonmoore1 it’s possible the switch is just bad if the sights aren’t floating then it’s empty

  • @j.v.automotive3773
    @j.v.automotive3773 ปีที่แล้ว

    Any instruction on how to change CDT sensor?

  • @tonyp6088
    @tonyp6088 ปีที่แล้ว

    Hey mate, thanks for posting these videos.
    I have a carrier supra 750. Evaporator fans in the box are not working. The box has 2 evaporators, each with 3 fan motors And none of them are working.
    The rest of the unit is operating correctly. No error codes. Any ideas?

    • @RampFisha
      @RampFisha 11 หลายเดือนก่อน

      check voltage to fans. if you are getting 12V and good ground then replace fans.

  • @rupeshthapa2409
    @rupeshthapa2409 7 หลายเดือนก่อน

    System clk error code
    So how can I solve this problem any idea

  • @alr9170
    @alr9170 ปีที่แล้ว

    Greeting Sir. I got a frozen bread for some reason when I was empty my set tem was -10, aftet loaded i can't get down pass 1°F on my 7300x4. I didn't get no alarm. I take it to the shop, the tech told me it's running perfectly fine. I don't have any problem, refrigerant level fine. I'm confused to why the screen show i can't get to the set temperature?

    • @californiadreaming9216
      @californiadreaming9216 2 หลายเดือนก่อน

      air9170 hello. I am NOT a reefer tech. If your unit will not cool the trailer as it should, it can be because the weather is so hot that your condenser is overheating. You can try shutting unit off and spraying cool water on condenser to cool it off, then re-starting unit, see what happens. Good luck.

  • @javierarreola6867
    @javierarreola6867 หลายเดือนก่อน

    Bro I am a owner operator and I would like to lear fix my reefer I spend lot of money on service can you help

  • @SureshKumar-gx7ot
    @SureshKumar-gx7ot 4 วันที่ผ่านมา

    Hii bro good job

  • @phoenix6209
    @phoenix6209 3 หลายเดือนก่อน

    My high pressure alarm came on for about 5 min but the reefer ran fine. Should I be worried?

    • @markm0000
      @markm0000 2 หลายเดือนก่อน +1

      Wash the condenser good with soap and a garden hose for a half hour.

    • @phoenix6209
      @phoenix6209 2 หลายเดือนก่อน +1

      @@markm0000 thanks I’ll try it!

    • @markm0000
      @markm0000 2 หลายเดือนก่อน

      @@phoenix6209 if that still happens check the belts they should have a little give but not flapping around while running. One of the fans might be going bad. I suggest taking it to a Carrier dealer.

  • @wadekornegay5309
    @wadekornegay5309 5 หลายเดือนก่อน

    My unit run for about 3to5 mins shut off than I bush the switch ucome back on an repeat it shut of again

  • @Ggtube1000
    @Ggtube1000 2 ปีที่แล้ว +1

    How do you clear the Freon??

    • @StickShiftRacing
      @StickShiftRacing  2 ปีที่แล้ว

      Not understanding your question

    • @Ggtube1000
      @Ggtube1000 2 ปีที่แล้ว

      @@StickShiftRacing The very first thing you said that it has too much Freon. How do you go about correcting that issue?

  • @Makehimherhappy
    @Makehimherhappy 3 ปีที่แล้ว +1

    More power❤

  • @tonis6559
    @tonis6559 2 ปีที่แล้ว +1

    carrier supra 850 nordic HI PRESS code was fixed with a new battery.

  • @davidjimenez440
    @davidjimenez440 3 ปีที่แล้ว +1

    Have a question sir

  • @jaymelz324
    @jaymelz324 ปีที่แล้ว +1

    Hey I have a Supra 860 with the hi press readout. Had blown fuse for compressor unloaded. How do I check this? Belts are good

    • @StickShiftRacing
      @StickShiftRacing  ปีที่แล้ว

      needs a unloader valve check if its magnatized

    • @jaymelz324
      @jaymelz324 ปีที่แล้ว

      @@StickShiftRacing ok thanks my man