Changing a Compressor On a Mini-Split Air Conditioner!

แชร์
ฝัง
  • เผยแพร่เมื่อ 4 ก.ค. 2024
  • In this video I return to a call where I diagnosed a faulty compressor 2 months ago! #hvacguy #hvac #airconditioning #hvaclife #electrician #airconditioner #hvactrainingvideos #hvaccompany #hvactroubleshooting #skilledtrades #bluecollar #bluecollarpride #minisplit ‪@FieldpieceProducts‬ ‪@MilwaukeeTool‬ ‪@mideaairconditioning4011‬ #compressor
    Merch Store : hvac-guy-2.creator-spring.com
    Here are links to the tools I use, And it costs you nothing extra to buy from this list:
    Makita Wet/Dry Vac: amzn.to/3VVHpsz
    Veto OT-LC: amzn.to/3wSK1Nj
    Appion AV760: amzn.to/3OkrwHC
    Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
    Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
    Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
    Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
    Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
    Fieldpiece Bluetooth Scale: amzn.to/3Gzveab
    Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
    Yellow Jacket Tubing Expander: amzn.to/3sjuK3a
    Milwaukee M12 Impact Driver: amzn.to/37xXkqk
    DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
    Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
    Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
    Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
    Klein Knee Pad: amzn.to/3cy6FB0
    Klein 7in1 Flip Socket: amzn.to/3bpabwG
    Klein Journeyman Pliers: amzn.to/3tvB60w
    Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
    Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
    Milwaukee Tool Box: amzn.to/322iyK9
    Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
    Milwaukee Hook Blade Knife: amzn.to/33F3m5T
    Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
    Western Nitrogen Regulator: amzn.to/3rmdKrx
    Klein Canvas Bucket: amzn.to/3FyzKVf
    Flag Velcro Patch Kit: amzn.to/3K8Eswx
    Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
    Milwaukee Magnetic Light: amzn.to/3FulCfF
    Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
    SS2 Float Switch: amzn.to/3K7LJMW
    3-Amp Breaker: amzn.to/3nxaSXJ
    Appion Valve Core Removal Tool: amzn.to/33CFArw
    Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
    Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
    Similar Small Tubing Bender: amzn.to/3fJsziJ
    Fluke Twist Guard Test Leads: amzn.to/3216R6j
    Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
    Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
    SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
    Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
    Quick Check Acid Test: amzn.to/3GA2XAy
    Wiha Torqe Screwdriver : amzn.to/3u1swH6
    Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
    Compressor Tote: amzn.to/3H8xHst
    Inspection Mirror: amzn.to/3r9PERV
    Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
    1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

ความคิดเห็น • 117

  • @scottjones7279
    @scottjones7279 3 วันที่ผ่านมา +5

    That tight spot that you were brazing in looked like a good place for Staybrite8

  • @user-us5eh3xl1z
    @user-us5eh3xl1z 3 วันที่ผ่านมา +24

    Curtis, I wish to pay you a compliment… I just clicked “do not recommend channel” for Non DIY HVAC… for one main reason: Ted is so disrespectful at times, talks smack about his PAYING CUSTOMERS and is generally too full of himself for my liking. You have massive skill and experience and you display NONE OF those DB qualities that Ted can’t seem to bring himself to stop. Nicely done work. Polite and a lack of egomania. From one tradesman (frame and finish carpenter) to another… WELL DONE. 👍🏼

    • @HVACGUY
      @HVACGUY  3 วันที่ผ่านมา

      Thanks

    • @Paul-IE-Repairs
      @Paul-IE-Repairs 3 วันที่ผ่านมา +2

      ted cook is what you call old school

    • @blh3741
      @blh3741 3 วันที่ผ่านมา +2

      I don't mind Ted C. and his attitude towards DIY, he's not posting videos for DIY'ers. But his info is still teachable to anyone who takes the time. Most HVAC distributors in Calif will not sell anything to DIY, refrigerant related or not. I'm retired/disabled and it took a while to connect with a distributor who will sell to me. If you want an arrogant D.B., it's Mikey Pipes. Curtis is educational and humble. He's in my top 5 YT'ers

    • @ChipWoodsworth
      @ChipWoodsworth 2 วันที่ผ่านมา +1

      ​@blh3741 I like Mikey Pipes videos, but I have noticed as of recent, that every business he merges with, or aquires, ends up with no employees, and the business partner, or previous owner ends up no longer working there. At first, I didn't think much about it, but after a few times, I think his problem lies in the mirror.

  • @HandSolitude
    @HandSolitude 4 วันที่ผ่านมา +15

    Love how you used the oxyacetylene to chase off that bug.

  • @user-yw9wn2vx6y
    @user-yw9wn2vx6y 4 วันที่ผ่านมา +7

    That relief on your face says it all..

  • @mrsmith5114
    @mrsmith5114 4 วันที่ผ่านมา +21

    Love to know the price of this job. I would think it be cheaper to buy a new mini split than replace the compressor. Even more so if the compressor wasn't under warranty.

    • @Djcarp83
      @Djcarp83 3 วันที่ผ่านมา +4

      Yes and all the dc shit and exv’s, drier and all of the other bs that come with those!!!! Just buy a new one

    • @mrsmith5114
      @mrsmith5114 3 วันที่ผ่านมา +2

      @@Djcarp83 Plus new warranty. But yeah, would love to know.

    • @anthonyrauseo5913
      @anthonyrauseo5913 3 วันที่ผ่านมา +6

      Home warranty company would rather pay $50 less to fix the old then the additional $50 it cost to get brand new lol

    • @davidwatson962
      @davidwatson962 3 วันที่ผ่านมา

      Do you use flux on you soldering joint

    • @stevee7774
      @stevee7774 3 วันที่ผ่านมา +8

      @@davidwatson962- He’s brazing the joints so no need for flux.

  • @NoxareHampton
    @NoxareHampton 4 วันที่ผ่านมา +10

    Hello love your videos keep up good work!!!

    • @HVACGUY
      @HVACGUY  4 วันที่ผ่านมา +2

      Hey, thanks!

  • @zunar_j5_933
    @zunar_j5_933 4 วันที่ผ่านมา +10

    What a pain in the arse job! Well done.

  • @UncleEarlHeatingAirCondition
    @UncleEarlHeatingAirCondition 4 วันที่ผ่านมา +11

    Nice of you to share, as always.
    Just info, A Captain Hook tip by Uniweld works perfectly on these for brazing tight locations.
    There is a learning curve, but you should give it a try .
    It comes in 3 different sizes ( part numbers NTF-5, NTF-9, NTF-17 ).
    I thought you might have one when you said
    "break out my Hook", but never saw it

  • @stephenbullock-yn3vh
    @stephenbullock-yn3vh 4 วันที่ผ่านมา +7

    Super excellent work curtis 👍👌✌️

    • @HVACGUY
      @HVACGUY  4 วันที่ผ่านมา +3

      Thanks 👍

  • @kens.3729
    @kens.3729 3 วันที่ผ่านมา +5

    Thanks for your persistence with getting this Mini-Split Operational again. Thank GOD they had two (2) window Units. We have one (1) Heat Death in STL so far. 🙏

  • @key-sendo
    @key-sendo 3 วันที่ผ่านมา +3

    That third bolt in the back for the feet of the compressor and getting the crankcase heater back on have to be some of the hardest things to do in hvac 😂😂😂

  • @daeroc
    @daeroc 3 วันที่ผ่านมา +5

    Love it when it all goes according to plan

  • @Infowarrior-45
    @Infowarrior-45 2 วันที่ผ่านมา

    I had a Carrier mini split with similar issues. Compressor checked fine, but every time it was powered up, it blew the fuses in the disconnect. If unplugging the Compressor, it wouldn't blow the fuses. Carrier tech support argued with me that the Compressor, being DC voltage, shouldn't blow a fuse. After explaining to him that I had already replaced the board, he agreed I should replace the Compressor. I guess we'll see, when it arrives if I am right or not.

  • @jimdavis6833
    @jimdavis6833 4 วันที่ผ่านมา +4

    I feel cooler already.

  • @jme36053
    @jme36053 4 วันที่ผ่านมา +7

    Makes you wonder if the compressor issue was partly caused by mis-wiring earlier.

    • @Balticblue93
      @Balticblue93 4 วันที่ผ่านมา +5

      100%!! I bet the other compressor wasn't bad, but wired incorrectly. That is why it didn't fail his ohming testing.

    • @mikar3601
      @mikar3601 3 วันที่ผ่านมา +2

      @@Balticblue93 ooof!

  • @SpecialistOne
    @SpecialistOne 3 วันที่ผ่านมา +2

    Customers really need to tell you that they had someone look at the condenser. That person may have disconnected the wires to do a ohm check and was careless to put them back on correctly. So, may be it was a bad board and a good compressor, but not knowing what went on before you, makes the job harder to diagnose and fix.

  • @gurskysgarage
    @gurskysgarage 3 วันที่ผ่านมา +2

    Nice work keep up the good videos!

    • @HVACGUY
      @HVACGUY  3 วันที่ผ่านมา

      Thanks, will do!

  • @kennymayo4578
    @kennymayo4578 4 วันที่ผ่านมา +4

    Good braze job, i always seem to struggle in those tight areas

  • @stevencossaboon3237
    @stevencossaboon3237 4 วันที่ผ่านมา +2

    Nice work Curtis. Mini splits suck even more when its hot.

  • @bobboscarato1313
    @bobboscarato1313 3 วันที่ผ่านมา +1

    Good job Curtis; tight spot and bugs all over!

  • @robalexander7348
    @robalexander7348 3 วันที่ผ่านมา +2

    Well done Curtis, that sure was a tight area to work in 😣 Au

  • @TomLawson05
    @TomLawson05 3 วันที่ผ่านมา +1

    Great change out Curtis glad all went well on to the next thanks for the video

  • @dsnow2835
    @dsnow2835 3 วันที่ผ่านมา +1

    Did a compressor aswell today in Charlotte, NC. It was hot as heck. Good work as always.

    • @HVACGUY
      @HVACGUY  3 วันที่ผ่านมา

      Thanks 👍

  • @krishuntzeroable
    @krishuntzeroable 4 วันที่ผ่านมา +2

    I totally feel ya having a fan blowing on you outside. It’s that bad out here.

  • @harryschrysan3183
    @harryschrysan3183 3 วันที่ผ่านมา +3

    I had to do one of those on top of a ladder. Fuck that shit, I called my boss to help me. I ain't killing my self. 😡

  • @bobchamp3159
    @bobchamp3159 3 วันที่ผ่านมา +1

    You know, its always hard to make the judgement call, but really the board could have been bad which leads to compressor to fail. Anyway, either way it gets a new board now. Nice job

  • @jamienoel
    @jamienoel 3 วันที่ผ่านมา +5

    Watch out for ticks working in the grass like that.

    • @stevee7774
      @stevee7774 3 วันที่ผ่านมา +2

      Ticks, chiggers, and snakes!

  • @osvaldomcs1213
    @osvaldomcs1213 4 วันที่ผ่านมา +4

    A bit more gas. 😂😂

  • @davidb2438
    @davidb2438 4 วันที่ผ่านมา +7

    Cheaper to throw it out and install new condenser

  • @ntsecrets
    @ntsecrets 2 วันที่ผ่านมา

    I looked in the manual at one of the popular midea clone units that use those gmcc compressors and the terminals didn’t seem to matter on the compressor because it’s 3 phased and same impedance on all terminals. And from what I understand the rotation on those doesn’t matter. But I am all for hooking the right wires to the right place! Might just come from the factory that way.

  • @search_eternal
    @search_eternal 3 วันที่ผ่านมา

    Nice job. I was confused by the pressures being the same then remembered those units only have low side ports LOL.

  • @chrisnapier5626
    @chrisnapier5626 3 วันที่ผ่านมา +1

    Great job,Curtis!

    • @HVACGUY
      @HVACGUY  3 วันที่ผ่านมา

      Thanks!

  • @anthonyelectric6045
    @anthonyelectric6045 3 วันที่ผ่านมา

    That was a hot mess of a job for sure. The heat really takes its toll and good thing for that portable fan. Although it needs a a/c switch setting 😅

  • @harrydickson4575
    @harrydickson4575 4 วันที่ผ่านมา +2

    Awesome job 👍👍👍

    • @HVACGUY
      @HVACGUY  4 วันที่ผ่านมา

      Thanks 👍

  • @icandreamstream
    @icandreamstream 3 วันที่ผ่านมา +1

    I have one of the older midea inverter mini split units, it has a 3 ton Mitsubishi compressor in it. Shocked to see high quality parts in some of those Mideas.

  • @donaldhoudek2889
    @donaldhoudek2889 3 วันที่ผ่านมา

    I guess my question would be, Why don't the manufactures put a screw-on fitting on the compressors, it would make it so much easier to replace a compressor. I installed an air conditioner in my '65 Mustang (all screw-on fittings) and 20 years later it was still working great so it can't be vibration issues. It would have been so much easier to replace the compressor with fittings and not have to solder it. Great video!

    • @houptee
      @houptee 3 วันที่ผ่านมา

      Fittings cost more than a swaged brazed joint. They are making thousands of these units a week in China. They don't care about the technicians that have to work on them. These minis are basically throw away machines when they have major problems you can order the entire system with indoor unit online for under 1000 bucks. The off brands are even cheaper and they are made by Midea or Gree.

  • @bobbyr8071
    @bobbyr8071 4 วันที่ผ่านมา +1

    That Milwaukee vacuum pump is so expensive. U can get a 1kw battery pack and a compressor for that much. The battery pack can be used to power other tools

  • @lolkzmk3548
    @lolkzmk3548 3 วันที่ผ่านมา +1

    In my place usually just replace the outdoor unit , glad to see people who have skill like you

  • @MarcHord-mk5ff
    @MarcHord-mk5ff 3 วันที่ผ่านมา

    I hope it paid good, it looked brutal. I think I’ve done one compressor in mini split. My price is high now.

  • @tonyhvactechinian_
    @tonyhvactechinian_ 4 วันที่ผ่านมา +3

    I have a Mitsubishi mini split that keeps going into defrost mode. I’ve changed the sensors and the board and still doing the same thing. It works fine in cooling.

    • @Bob.W.
      @Bob.W. 3 วันที่ผ่านมา +1

      Had to replace both boards on our Carrier Mini-split (Midea) after a lightning strike got into the house wiring. Touchy stuff.

    • @sprockkets
      @sprockkets 3 วันที่ผ่านมา

      Where is the sensor?

  • @HandSolitude
    @HandSolitude 4 วันที่ผ่านมา +4

    I take it that was a multi head split system which is why it was worth repairing rather than replacing?

    • @HVACGUY
      @HVACGUY  4 วันที่ผ่านมา +7

      Yes

  • @skyman2002
    @skyman2002 4 วันที่ผ่านมา +6

    GMCC compressors... they use those in the Midea made products, Dehumidifiers, Window units, portable units ETC.

    • @HVACGUY
      @HVACGUY  4 วันที่ผ่านมา +8

      Well, this is a midea product

    • @jordenb9469
      @jordenb9469 4 วันที่ผ่านมา +2

      Gmcc compressor company was once Toshiba. They are very inexpensive compressors used in every brand in the world. I mean every brand. Quality is very good for the price point.

    • @sprockkets
      @sprockkets 3 วันที่ผ่านมา +1

      ​@jordenb9469 well, not gree, or Mitsubishi, or fujitsu, or daikin, or their rebrands.

    • @jordenb9469
      @jordenb9469 3 วันที่ผ่านมา

      ​You sir are incorrect. I suggest you take the sound blanket off thenm and see for yourself. Not all but alot have the gmcc compressors. Gree flexx is one. ​@@sprockkets

    • @sprockkets
      @sprockkets 2 วันที่ผ่านมา

      @@jordenb9469 gree flexx uses a zhuhai compressor, just like every gree product.

  • @Djcarp83
    @Djcarp83 3 วันที่ผ่านมา +1

    A little Fajine gas never hurt no one 😂

  • @Djcarp83
    @Djcarp83 3 วันที่ผ่านมา +2

    Purge purge purge purge

  • @ntsecrets
    @ntsecrets 2 วันที่ผ่านมา

    I’ve had 2 of these die on me pretty much identical to the unit you are servicing. The smaller units are so cheap it’s easier to just replace the whole unit. But I wonder if I should try this? lol.

  • @caru3257
    @caru3257 3 วันที่ผ่านมา +1

    I did a Bosch compressor and they are a pain.

  • @famousdude1239
    @famousdude1239 3 วันที่ผ่านมา +1

    You didn't even take a rag and wipe the bottom of the condensing unit, just mounted the compressor directly over the dirty bottom???

  • @ezalku
    @ezalku 4 วันที่ผ่านมา +3

    any inputs of why is the pressures equally at the end ?
    ohh 2 on low pressure side 😅

    • @HVACGUY
      @HVACGUY  4 วันที่ผ่านมา +2

      Both are on suction of different circuits

    • @ezalku
      @ezalku 4 วันที่ผ่านมา

      @@HVACGUY thanks ✌

  • @Dr2Rock2
    @Dr2Rock2 3 วันที่ผ่านมา

    Whats the springy thingy you took off first for?

  • @TooCloseSeries
    @TooCloseSeries 4 วันที่ผ่านมา +1

    You need a block of ice in front of that fan. 😏

  • @bigscout1584
    @bigscout1584 3 วันที่ผ่านมา

    What is the red rubber band for?

  • @RongDuck
    @RongDuck วันที่ผ่านมา +1

    Hey Curtis. Random question. Milwaukee everything. DeWalt fan. Sup with that?

  • @Browner19
    @Browner19 3 วันที่ผ่านมา

    Someone else was there and put the wires on wrong, oops

  • @professionalinspectionserv9468
    @professionalinspectionserv9468 2 วันที่ผ่านมา

    I thought mini splits no longer brazed and were all connections to prevent contamation? Or is that newer ones? I was waiting for you to melt some wires...

  • @namskramskram6009
    @namskramskram6009 2 วันที่ผ่านมา

    How long are you pulling vacuums with that thing?

  • @manuelcirino1456
    @manuelcirino1456 4 วันที่ผ่านมา +5

    Curtis why don’t change just the outside

    • @bobboscarato1313
      @bobboscarato1313 3 วันที่ผ่านมา

      Maybe compressor is still in warranty!

    • @tekjunkie28
      @tekjunkie28 3 วันที่ผ่านมา

      Multi header unit

    • @bobboscarato1313
      @bobboscarato1313 3 วันที่ผ่านมา

      @@tekjunkie28 Thank you!

  • @christopherreus7799
    @christopherreus7799 4 วันที่ผ่านมา +3

    Hello Curtis

    • @HVACGUY
      @HVACGUY  4 วันที่ผ่านมา +1

      What’s up?

    • @christopherreus7799
      @christopherreus7799 3 วันที่ผ่านมา

      @@HVACGUY not much been hot here keep up the good work love your vids and your a hard worker 💪

  • @rustyhooks
    @rustyhooks 3 วันที่ผ่านมา

    I see your DeWalt fan, how do you like it?does it help stay cool

  • @iyaayas200
    @iyaayas200 3 วันที่ผ่านมา +1

    aren't those DeWalt fans great? I love mine

    • @HVACGUY
      @HVACGUY  3 วันที่ผ่านมา

      Love it

  • @RobertTuck-vo8cw
    @RobertTuck-vo8cw 3 วันที่ผ่านมา

    Why don't mini splits use a filter drier? (I know that external lines are not liquid lines}
    OI thought that you would test for acid.

  • @CT-vm4gf
    @CT-vm4gf 3 วันที่ผ่านมา +1

    You call air conditioners mini splits in the US, is that because the outdoor unit is smaller than other units?

    • @HVACGUY
      @HVACGUY  3 วันที่ผ่านมา

      This style, which is normally non-ducted we call mini splits.

  • @mikemaki1104
    @mikemaki1104 4 วันที่ผ่านมา +3

    What is the brand of the mini split

    • @nicolasmuniz9452
      @nicolasmuniz9452 4 วันที่ผ่านมา +2

      MPN, never heard of it but probably the cheapest the mfg housing builder could find, any reg split system would be better.

    • @HVACGUY
      @HVACGUY  4 วันที่ผ่านมา +3

      It’s a Midea product

  • @kevinmills5293
    @kevinmills5293 3 วันที่ผ่านมา

    U can C why they are called MINI split.

  • @cornbread1955
    @cornbread1955 4 วันที่ผ่านมา +1

    👍👍👍😎☕

  • @chrisscott1547
    @chrisscott1547 3 วันที่ผ่านมา

    Spend $150 on a Harbor Freight hi-vel fan and run it off a cheater cord. It will put out 10x the air compared to that battery fan.

  • @m9ovich785
    @m9ovich785 4 วันที่ผ่านมา +3

    HAHAHHA You heard Me shouting, Cut the Pipe off, No need to worry about chips going into the old Compressor ...
    Do You have Circle Flame head ??

  • @jujuanddaddyflash7773
    @jujuanddaddyflash7773 3 วันที่ผ่านมา

    Why didn't you just change the condenser? It's 2 flairs

  • @sziltner
    @sziltner 4 วันที่ผ่านมา +1

    Those mini splits look like a pain. And ??? Quality! 🙄

  • @SeatonHeatingAC
    @SeatonHeatingAC 3 วันที่ผ่านมา +1

    What happened to my comment?

  • @panamacitybeachbum
    @panamacitybeachbum 3 วันที่ผ่านมา +1

    6 out of 10 pain in the butt.

  • @fernandobazan829
    @fernandobazan829 4 วันที่ผ่านมา +1

    At least you admitted it but you never tested the compressor once it was out like you said you would? I bet it was still good operator error? no wonder you were relieved when it worked lol I hate those mini splits pos for sure good video might want to use one of those 10x10 canopy next time no sense heat stroking out never be able to enjoy your retirement my grandpa said a man who takes short cuts always takes two paths

  • @tomclements7590
    @tomclements7590 3 วันที่ผ่านมา +1

    Waist of time and money labor compressor freon headach would have put new unit in.

  • @DabblelyDiddly
    @DabblelyDiddly 3 วันที่ผ่านมา +1

    glorified window unit.

  • @chrissipple1018
    @chrissipple1018 3 วันที่ผ่านมา

    Another crap mini split system.

  • @charlesmcadory8286
    @charlesmcadory8286 3 วันที่ผ่านมา +1

    If you have problems with wasp, this is the best wasp spray I have ever used. BASF - 597802 - PT Wasp-Freeze II - Wasp and Hornet Insecticide