How Manifold Gauge Works? | Refrigerant Pressure Gauge | Animation | HVAC

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 ส.ค. 2024
  • A manifold gauge, also known as a refrigeration gauge or HVAC gauge, is a tool used by HVAC technicians and refrigeration professionals to measure and monitor various parameters of a refrigeration or air conditioning system. It helps them assess the system's performance, diagnose issues, and ensure that the system is operating efficiently. The manifold gauge set consists of several components, including pressure gauges, hoses, and valves.
    Here's how a manifold gauge works:
    Pressure Gauges: The manifold gauge set typically includes two pressure gauges - a high-pressure gauge and a low-pressure gauge. These gauges display the pressure levels of the refrigerant within the system. The pressure is measured in pounds per square inch (PSI) or sometimes in bar units.
    High-Pressure Gauge: This gauge measures the high side pressure of the refrigeration system, which is the pressure of the refrigerant as it exits the compressor and moves toward the condenser.
    Low-Pressure Gauge: This gauge measures the low side pressure of the system, which is the pressure of the refrigerant as it enters the evaporator after passing through the expansion valve.
    Hoses: The manifold gauge set comes with hoses that connect the pressure gauges to the corresponding pressure ports on the refrigeration system. The hoses are color-coded - blue for the low-pressure side and red for the high-pressure side. This helps prevent mix-ups and ensures correct connections.
    Valves and Knobs: The manifold gauge set has several valves and knobs that allow the technician to control the flow of refrigerant and pressure within the system. These valves include:
    High-Side Valve: Controls the flow of refrigerant between the high-pressure gauge and the high-pressure side of the system.
    Low-Side Valve: Controls the flow of refrigerant between the low-pressure gauge and the low-pressure side of the system.
    Service Valve: This valve is used to connect the manifold gauge set to the refrigeration system. It allows the technician to take pressure readings and perform various tasks without releasing refrigerant.
    Operation: To use the manifold gauge set, the technician connects the hoses to the pressure ports on the system. They then open the service valves to allow the refrigerant to flow into the gauges. The pressure readings on the gauges give the technician insights into the operating conditions of the system.
    If the pressure readings are too high, it might indicate overcharging or a problem with the condenser or expansion valve.
    If the pressure readings are too low, it could indicate undercharging, a refrigerant leak, or an issue with the evaporator or compressor.
    Temperature Conversion: In addition to pressure readings, some manifold gauge sets also include temperature scales. These scales allow technicians to convert pressure readings into corresponding temperatures for different refrigerants. This can be useful for diagnosing issues and ensuring proper system performance.
    Remember that working with refrigerants can be hazardous, and proper training and safety precautions are essential when using a manifold gauge set. It's important to follow manufacturer guidelines and industry best practices to ensure both your safety and the proper functioning of the refrigeration or air conditioning system.

ความคิดเห็น • 55

  • @leszekporeysky6441
    @leszekporeysky6441 8 หลายเดือนก่อน +7

    I've been learning the profession for a year, I've finished courses, I've watched a thousand films, and only now I understand what it's all about.

  • @nolaguy1408
    @nolaguy1408 หลายเดือนก่อน +1

    Thank You, my goodness!! You just don't know how many vids are out there (for newbies) that give 0 explanation of how these things work.

    • @zebralearningsenglish-pn6fl
      @zebralearningsenglish-pn6fl  หลายเดือนก่อน +1

      I'm so glad! Thank you 😊

    • @jollyscaria1922
      @jollyscaria1922 หลายเดือนก่อน

      Stanrd usin coler gueg is righted blu sudion lo side read high side cgerging yeow colur uding vacum cherging lind using welcomed gues

  • @miamiholliwoodmiamiholliwo9192
    @miamiholliwoodmiamiholliwo9192 9 วันที่ผ่านมา

    Thanks

  • @VencerVents
    @VencerVents 6 หลายเดือนก่อน +3

    a very simple video but very informative. thank you brother.

  • @maximinoco1452
    @maximinoco1452 2 หลายเดือนก่อน +1

    thanks for sharing your knowledge to beginners like me God Bless!

  • @arshivarvariya571
    @arshivarvariya571 ปีที่แล้ว +3

    Thank you. Make more videos on ac repairing

  • @macariosakay5269
    @macariosakay5269 8 หลายเดือนก่อน +1

    Very clear to understand. I'm your subscriber from now on.

  • @kachunwong8184
    @kachunwong8184 หลายเดือนก่อน

    If I want to vacuum the 2 connection coils and evaporation coils except air-cooling pipe, which gauge (red or blue) is suitable?

  • @sakthivelsaravanan42
    @sakthivelsaravanan42 18 วันที่ผ่านมา

    Sir r22,r32 gas cylinder stiker missing cylinder mixing not identified what solution plz

  • @honestman276
    @honestman276 2 หลายเดือนก่อน

    Good pronunciation and easy language of this vedio help us to understand. Thanks from Bangladesh.

  • @mohammadhussein3076
    @mohammadhussein3076 หลายเดือนก่อน

    Good illustration

  • @Sc19869
    @Sc19869 6 หลายเดือนก่อน +2

    I forgot do we open the valves to check the pressures, or only when we charge or recover

  • @vcv1023vcv1023
    @vcv1023vcv1023 4 หลายเดือนก่อน +1

    thanks for the videos.

  • @sunimalfernando4347
    @sunimalfernando4347 5 หลายเดือนก่อน +1

    Thank you!!

  • @englishstudymasumahmed7565
    @englishstudymasumahmed7565 3 หลายเดือนก่อน +1

    Nice Video

  • @santoshkumarpatra1426
    @santoshkumarpatra1426 3 หลายเดือนก่อน +1

    Nice 👍

  • @joeoehm4341
    @joeoehm4341 6 หลายเดือนก่อน

    Is it also possible to charge via the red hose? I would like to recover (with recovery machine) via the yellow hose, the yellow hose is connected to the blue port on the bottle. And charging via the red hose, which is connected to the red port on the bottle. So there would be no need to unplug the hoses.

  • @Mr_jakkula5687
    @Mr_jakkula5687 5 หลายเดือนก่อน +1

    What is low pressure and High pressure

  • @user-hn8ls3id6c
    @user-hn8ls3id6c 7 หลายเดือนก่อน +1

    Nice

  • @CATechTips
    @CATechTips หลายเดือนก่อน

    ❤❤❤

  • @AnandRaj-ku9gn
    @AnandRaj-ku9gn ปีที่แล้ว +1

    Good

  • @gabrielmerza6904
    @gabrielmerza6904 4 หลายเดือนก่อน +1

    While i’m watching and listening my head automatically start going lift and right .

  • @SabirAfridi-pi7jn
    @SabirAfridi-pi7jn 5 หลายเดือนก่อน +1

    How I understand that my car A/C gas is full

  • @xiaozhang7075
    @xiaozhang7075 ปีที่แล้ว +1

    thank you somuch

  • @sheblalameri7891
    @sheblalameri7891 5 หลายเดือนก่อน +1

    Why do we have a temperature gauge inside the gauge?

  • @LubaLuba1
    @LubaLuba1 หลายเดือนก่อน

    Incorrect the yellow hose is not connected to the red hose only blue.

    • @zebralearningsenglish-pn6fl
      @zebralearningsenglish-pn6fl  หลายเดือนก่อน

      Sorry, I don't understand.

    • @raffuy9745
      @raffuy9745 หลายเดือนก่อน

      And where did you learn that? Yellow is connected to both you just need to open the valve

  • @harvsbautista4696
    @harvsbautista4696 7 หลายเดือนก่อน +2

    Tanginamo Patel

    • @zebralearningsenglish-pn6fl
      @zebralearningsenglish-pn6fl  7 หลายเดือนก่อน

      Hi 👋

    • @mrpankajsharma6582
      @mrpankajsharma6582 6 หลายเดือนก่อน

      Hi sir apka video bahut samjh me ata hai

    • @mrpankajsharma6582
      @mrpankajsharma6582 6 หลายเดือนก่อน

      Please manifold guage ka pura low pressure and high pressure kab use kar kab nahi iska video banau please

  • @kokeri1
    @kokeri1 4 หลายเดือนก่อน +1

    Incomplete information.

  • @tourismagency
    @tourismagency 8 หลายเดือนก่อน +1

    ❤❤❤