4:25 Please with reference to the second 1gang 2way switch where its common is taken to the lampholder, will the lampholder work if the two strappers or pass wire or travellers are connected or terminated these way in the intermediate switch: 1. L22 & L21 2. L11 & L12 3. L22 & L12 4. L21 & L11 Because the L1 and L2 of the intermediate switch is taken to the other 1gang 2way switch which its common has the switch feed or supply
Great content, Thank you. Would this be the same wiring in a DC application, using DC Rocker switches ? Is the “Intermediate” switch ON-OFF-ON and the two (end) switches ON-ON ?
Well, intermediate switch wiring doesn't directly use logic gates as physical components But it's operation shares some similarities with the AND and XOR gates:
I think that would be a waste of time and money just use two 2-way switches. th-cam.com/video/83LqmCQHGYE/w-d-xo.html th-cam.com/video/Tg7JH3xPwTc/w-d-xo.html
Sir please the intermediate switch I know has four terminals which are L1, L2, L3 & L4 where from one two way switch comes to L1,L2 and the other two switch comes to L3, L4 but yours is different.
that happens if you don't wire them well. watch the video carefully and do it well. you don't just connect them anyhow. Any of the switches should be able to control the lamp(s) irrespective of the switching position of the intermediate
Wow! All long i thought when doing three switching, one has to use two 1g2w and the intermediate switch, but in your video you used 2g2w instead of intermediate switch.
A 3gang switch will have L3, L31 & L32 The intermediate switch has only one gang with 6terminals. What you have has 9terminals. If it is so, then it's a 3gang switch and not intermediate. Please check and see
@@obloni_ElectricalSir please the intermediate switch I know has four terminals which are L1, L2, L3 & L4 where from one two way switch comes to L1,L2 and the other two switch comes to L3, L4 but yours is different.
@@obloni_Electricalthank you sir, but in this case, which of the L(L3,L3¹,L3²) is the com, since other 3gang switches I've seen are indicated"com,L1,L2 ". So in the L3,L3¹,L3² situation, where do you put the com
@@obloni_Electrical if i am right, looping will do series connection and hence 1 lamp damage wiil cause other to get Off. Isn't there any other way of connection ?
@@narbahadurpun506 this is series th-cam.com/video/kY_7vwjnuBA/w-d-xo.htmlsi=hVE2Q-uHBgi6MafC Parallel th-cam.com/video/9Os0zlOYpV8/w-d-xo.htmlsi=WlOgCiWyVn5GoAyv
I just feel like giving this 20 likes ....
That's great. share to 20 people bro. Thanks
4:25
Please with reference to the second 1gang 2way switch where its common is taken to the lampholder, will the lampholder work if the two strappers or pass wire or travellers are connected or terminated these way in the intermediate switch:
1. L22 & L21
2. L11 & L12
3. L22 & L12
4. L21 & L11
Because the L1 and L2 of the intermediate switch is taken to the other 1gang 2way switch which its common has the switch feed or supply
Your practical skills are great 👍...
I'm here again, thanks for sharing it with us
Great content, Thank you. Would this be the same wiring in a DC application, using DC Rocker switches ? Is the “Intermediate” switch ON-OFF-ON and the two (end) switches ON-ON ?
Sir I've really learnt a lot from your channel
That sounds great to hear
Nice sir thank you 💐👌👍
Thanks you proof 😮😢❤
good explanation, well done
What type of logic gate principle controls the switch to the lamp?
Well, intermediate switch wiring doesn't directly use logic gates as physical components But it's operation shares some similarities with the AND and XOR gates:
Thank you sir🤗
Very well explanation. Well done.
Thanks boss.
How can I use only de intermediate switch and one 2way switch
I think that would be a waste of time and money just use two 2-way switches.
th-cam.com/video/83LqmCQHGYE/w-d-xo.html
th-cam.com/video/Tg7JH3xPwTc/w-d-xo.html
Sir please the intermediate switch I know has four terminals which are L1, L2, L3 & L4 where from one two way switch comes to L1,L2 and the other two switch comes to L3, L4 but yours is different.
please click this link th-cam.com/video/ql3sIMpXuSg/w-d-xo.html this video will explain everything to you. there are two types.
@@obloni_ElectricalGood this video answers my question. But the intermediate switch with 6 terminals I haven't seen it before
@@danielteyehuago1633 it's there. It's very common now
Been of great help thanks
Sir, can you explain why the switch that is carrying the power is connected to the commons of the intermediate switch?
Thank you sir, pls can you make a video on how to connect gear switch or change over
please this link th-cam.com/video/0iyQvHXoflw/w-d-xo.html is a video on how to wire manual changeover switch
Pls is there any books 📚 to get the illustration from. I will be happy if you show me of Pdf
Please send your request: WhatsApp +233209323669
Please can you come with a video on Master switch
very well noted I will do that.
Thanks you bro
But sometimes if the intermediate is off the other 2 way switches don't work...why 🤔
that happens if you don't wire them well. watch the video carefully and do it well. you don't just connect them anyhow. Any of the switches should be able to control the lamp(s) irrespective of the switching position of the intermediate
Wow! All long i thought when doing three switching, one has to use two 1g2w and the intermediate switch, but in your video you used 2g2w instead of intermediate switch.
I'm a little bit confused out here because mine got L3, L31 and L32🤔
A 3gang switch will have L3, L31 & L32
The intermediate switch has only one gang with 6terminals. What you have has 9terminals. If it is so, then it's a 3gang switch and not intermediate. Please check and see
@@obloni_ElectricalSir please the intermediate switch I know has four terminals which are L1, L2, L3 & L4 where from one two way switch comes to L1,L2 and the other two switch comes to L3, L4 but yours is different.
@@obloni_Electricalthank you sir, but in this case, which of the L(L3,L3¹,L3²) is the com, since other 3gang switches I've seen are indicated"com,L1,L2 ". So in the L3,L3¹,L3² situation, where do you put the com
@@isaacnewton1707 So in that case L3 will be the commons.
@@obloni_Electrical thank you sir, you're the best
Please what off two lamps
You just loop from the other lamp.
@@obloni_Electrical if i am right, looping will do series connection and hence 1 lamp damage wiil cause other to get Off. Isn't there any other way of connection ?
@@angelaano please this video answers your question. th-cam.com/video/9Os0zlOYpV8/w-d-xo.htmlsi=GedrM3k47oxQD6cR
@@narbahadurpun506 this is series th-cam.com/video/kY_7vwjnuBA/w-d-xo.htmlsi=hVE2Q-uHBgi6MafC
Parallel th-cam.com/video/9Os0zlOYpV8/w-d-xo.htmlsi=WlOgCiWyVn5GoAyv
@@angelaano watch this for your answer th-cam.com/video/9Os0zlOYpV8/w-d-xo.htmlsi=XvQuYFGNKSRTYIu1
Thanks Sir
You are welcome
0:27 I'm back her again