Hello I have a problem with the QSX15 engine that runs on a slow rotation speed, but unstable rises, and the sound decreases, as well as when you press the fuel trample, it does not increase the engine speed
But another problem is that the engine in case of increased load, there is no efficiency... Note that the signal is not good in the Angkter No. 3, more than Angkter has changed and the same problem
Dear Sir, I have some problem to fuel shutoff valve. I was Check shutoff valve found resistance 8.2 ohms. But shutoff valve no work when engine running (run within 02 sec. & off gen-set). I manually supply 12 v dc to shutoff valve , then engine start & run Gen set no stop. Please good advise send to me. Rds. harun
Check first all warning ⚠️ alarm Make sure you don't have any warning alarm, if you have so warning first fix it about problem, then rest all alarm and try again
Check battery charging systems make sure alternator is working Battery conditions ok If these things are good the replace the shut off valve and try again
Sorry sir, previously I had a problem with the ECU ECM on the Cummins QSX15 generator with a problem with the HZ (frequency) not wanting to be adjusted, and the frequency was only stable at 50 Herzt, what should I do to solve this problem? Please help sir
First check the ECM relay! When the ECM relay is faulty that means ecm is not turning on. When the ecm is not turning on, ecm not sending starting signal to the starter relay,
Nice video sir info tech, sir can you make a video how to connect example dse controller to ecm or ecu, thanks and take care always sir
Thank you very much. That was really helpful
Thanks friends
Pls,
let me know the Cummins Qsk 23 engine with dse 8610 wiring diagram
1250 kva DG ka control circuit diagram ka practical video banaaiye
Hello
I have a problem with the QSX15 engine that runs on a slow rotation speed, but unstable rises, and the sound decreases, as well as when you press the fuel trample, it does not increase the engine speed
Check the idle speed setting,
The engine used is tied to the shover
Check clean all the actuator coupler and check all the wiring make sure ecm connector grip neat and clean
Thank you for solving the problem 👍
But another problem is that the engine in case of increased load, there is no efficiency... Note that the signal is not good in the Angkter No. 3, more than Angkter has changed and the same problem
Dear Sir, I have some problem to fuel shutoff valve. I was Check shutoff valve found resistance 8.2 ohms. But shutoff valve no work when engine running (run within 02 sec. & off gen-set). I manually supply 12 v dc to shutoff valve , then engine start & run Gen set no stop. Please good advise send to me. Rds. harun
First Which type of solenoid ?
3 wire or 2 wire
Check first all warning ⚠️ alarm
Make sure you don't have any warning alarm, if you have so warning first fix it about problem, then rest all alarm and try again
@@Info-Tech- Thanks sir. one wire shutoff valve. QSX15 cummins engine.
Check battery charging systems make sure alternator is working
Battery conditions ok
If these things are good the replace the shut off valve and try again
@@Info-Tech- Thanks. First Gen set start & within 2 second stop gen set. Error 254.
Sorry sir, previously I had a problem with the ECU ECM on the Cummins QSX15 generator with a problem with the HZ (frequency) not wanting to be adjusted, and the frequency was only stable at 50 Herzt, what should I do to solve this problem? Please help sir
Qsx15 frequency is adjusting by software only
Can you send me a catalog please.
Yes
Email me I send you abdurraheemk622@gmail.com
Hi brother Same Gsc ESM generator not taking self . Starter relay not working...what is the issue
First check the ECM relay! When the ECM relay is faulty that means ecm is not turning on. When the ecm is not turning on, ecm not sending starting signal to the starter relay,
@@Info-Tech- thanks issue resolved relay not sending signal to ECM relay base was faulty