  • @dadefope80
    @dadefope80 2 หลายเดือนก่อน +41

    "I'd rather jump off the flippin roof!" LOL Next Level Steve!

    • @apetro8895
      @apetro8895 2 หลายเดือนก่อน +4

      😂😂😂😂

    • @charlessullivan1504
      @charlessullivan1504 หลายเดือนก่อน

      Yes that Was funny I agree though 😄

  • @funny2man2004
    @funny2man2004 2 หลายเดือนก่อน +18

    Hey Steve not sure if you knew or not but there is a charge mode on those units. You hold the button on the board to force it into charge mode. I had a couple I accidentally over charged and discovered it.

  • @th-wt5pn
    @th-wt5pn 2 หลายเดือนก่อน +11

    Can’t believe steve installed a bosch inverter system 😱 wow lol
    Was looking for the rheem/ruud lol..
    Steve and Ms. Molly hvac 😂

    • @redneckways1617
      @redneckways1617 หลายเดือนก่อน +1

      @@th-wt5pn I found that the ones that don’t like them it’s for the reason they don’t understand them and don’t have the knowledge to successfully repair them…same goes for the similar GREE system

  • @gocubsgo5055
    @gocubsgo5055 2 หลายเดือนก่อน +13

    "Wow! She must me a lookah then" 😂😂

  • @craigirish9530
    @craigirish9530 2 หลายเดือนก่อน +15

    Mikey pipes will be proud. He put in a Bosch.

    • @eastpark4864
      @eastpark4864 2 หลายเดือนก่อน +12

      ... and for 1/2 of Mikeys pipes New York price.

    • @joeleslie7726
      @joeleslie7726 2 หลายเดือนก่อน +9

      Mikey Pipes likes smoking pipe

    • @Myoldiesrecordings
      @Myoldiesrecordings 2 หลายเดือนก่อน +2

      Found this channel because @mikepipes just put out a video about this

  • @DAS-Videos
    @DAS-Videos 2 หลายเดือนก่อน +8

    Nice install. The customer should be very happy.

  • @Garth2011
    @Garth2011 2 หลายเดือนก่อน +6

    Surprising they offer a PSC motor on current air handlers. First time I have seen a blower motor require a 20 uf cap. Man that duck work is awesome ! Lucky guy...

    • @Sesamestreet9080
      @Sesamestreet9080 หลายเดือนก่อน +1

      Goodmans have 20uf caps

    • @dwight.bennett
      @dwight.bennett หลายเดือนก่อน +1

      The base model of Bosch as a PSC blower motor, the 18 and 20 have ECM.

    • @Garth2011
      @Garth2011 หลายเดือนก่อน +1

      @@dwight.bennett I have found the "base" models in most anything tend to be the best value because they have the exact foundation/design/engineering as the higher end models, just less features and parts to go bad. I've been finding this out more and more and it helps when determining the best value when selecting an item.

  • @extremegaming2280
    @extremegaming2280 2 หลายเดือนก่อน +15

    “Common sense isn’t so common” 😂

  • @christopherdansby7848
    @christopherdansby7848 2 หลายเดือนก่อน +8

    Nice job Steve!! Congratulations on 200k subscribers 🎉

  • @jasonreinhardt1697
    @jasonreinhardt1697 2 หลายเดือนก่อน +5

    We have installed a few Bosch units and so far they have been pretty good units.

    • @jimmyc9734
      @jimmyc9734 2 หลายเดือนก่อน

      Been running a 5 ton Bosch heat pump for over a year. It has been excellent!

  • @john7017
    @john7017 2 หลายเดือนก่อน +1

    Carry a spray bottle with soapy water to cool down the joint and cleans up the joint. Also get a bottle of Laco Cool Gel to spray the king valves and evaporator connections before soldering to stop heat transfer, good stuff.

  • @J-Colt
    @J-Colt 2 หลายเดือนก่อน +15

    Steven installing Bosch mama! Old Mikey Pipes fav. System install looks awesome Steven!

    • @repro7780
      @repro7780 หลายเดือนก่อน

      I thought Navien was Mikey's favorite! 😉

    • @benjaminwallace4626
      @benjaminwallace4626 หลายเดือนก่อน

      ⁠@@repro7780# deathboxincorporated 😂

  • @user-sx2xy8dn9v
    @user-sx2xy8dn9v 2 หลายเดือนก่อน +4

    Another kick ass job Steve, the video was awesome and we can learn from it! Remain safe and keep them videos coming. ☝️✨️👍💥💢💯💫

  • @brentlypalmer4106
    @brentlypalmer4106 หลายเดือนก่อน +1

    Looks good! Highly suggest a surge protector for those units. It’ll save you some headache for sure.

  • @hvacdoc
    @hvacdoc 2 หลายเดือนก่อน +3

    You gotta put a surge protector on that disconnect, bosch requires it for warranty

    • @Keith_Mikell
      @Keith_Mikell หลายเดือนก่อน

      guess thats a project for a day soon.

  • @edwardkuntush9339
    @edwardkuntush9339 2 หลายเดือนก่อน +2

    Nice job Steve as always happy 60th birthday Steve

  • @jamiemason9548
    @jamiemason9548 ชั่วโมงที่ผ่านมา

    Hi Steven a good job done

  • @johnnylabenske1851
    @johnnylabenske1851 2 หลายเดือนก่อน +2

    Them Bosch units are some real good stuff I do market refer in AZ an I’m gonna throw one on my roof in the fall for next season

  • @shayton91
    @shayton91 หลายเดือนก่อน

    Got a new Bosch 4 ton with matched air handler and new ductwork last week. House has been beautiful ever since - sitting at 72F while it's 90F+ outside. My electric usage also dropped since I stopped using the window units (after the old Lennox unit died) which pleasantly surprised me.

  • @Gman2930
    @Gman2930 2 หลายเดือนก่อน +2

    Awesome install, Steve. Enjoy the installation process. Thank you.

  • @Chris-uh3cm
    @Chris-uh3cm หลายเดือนก่อน +1

    Steve you're the best!

  • @gmard1
    @gmard1 2 หลายเดือนก่อน +8

    When I saw the Bosch I thought it was Mikey pipes

    • @jph77
      @jph77 2 หลายเดือนก่อน +5

      "It's Me! Mikey "Fuckin" Pipes!"

  • @johngallati8164
    @johngallati8164 2 หลายเดือนก่อน +3

    DONT JUMP STEVIE I LOVE YOUR VIDEOS AND IM A PLUMBER

  • @charlessullivan1504
    @charlessullivan1504 หลายเดือนก่อน +2

    Congratulations on 200 k subscribers

  • @benf7259
    @benf7259 2 หลายเดือนก่อน +1

    Holy smokes. Bosch..definitely good enough for this neighborhood

  • @jackl9922
    @jackl9922 2 หลายเดือนก่อน +1

    Just starting video - looking forward to finishing. Thx Steve!

  • @bradleythomas5445
    @bradleythomas5445 2 หลายเดือนก่อน +2

    Big job. Excellent work as always, Steve.

  • @RandomDudeOne
    @RandomDudeOne 2 หลายเดือนก่อน +3

    So Bosch is making HVAC too. Forever I just saw Bosch power tools. Checked out my sisters new kitchen on the 4th and she had a new Bosch range.

    • @Keith_Mikell
      @Keith_Mikell หลายเดือนก่อน

      It's really made by intertek. which has been doing it for a long ass time.

  • @mikerefrigeration5736
    @mikerefrigeration5736 หลายเดือนก่อน +1

    Never tried bosch. But i like the mini split fully ducted AHU unitd

  • @8799crosby
    @8799crosby 2 หลายเดือนก่อน +3

    Not sure u charged that right , u need to put condenser into charge mode till it ramps up to 66 mhz , 6-8 degrees , when it’s out of charge mode it will read 15-16 degrees of sub cooling

  • @Skanzool
    @Skanzool 2 หลายเดือนก่อน +1

    I had a Trane furnace and it only lasted 12 years. The heat exchanger developed a big crack (which I saw with my own eyes!) and then the motherboard went. At that point I decided to get rid of it.

  • @user-yn8mz5bf9y
    @user-yn8mz5bf9y 2 หลายเดือนก่อน +3

    Get the checkbook out

  • @kens.3729
    @kens.3729 2 หลายเดือนก่อน +1

    Very Nice New Install, Steve. 👍🙏

  • @wirenutjoe
    @wirenutjoe 2 หลายเดือนก่อน +2

    That’s one high dollar disconnect switch mama

  • @realfreedom5029
    @realfreedom5029 2 หลายเดือนก่อน +1

    I’ve heard great things about those Bosch units

  • @redneckways1617
    @redneckways1617 2 หลายเดือนก่อน +1

    You will like the Bosch…check that amp draw after you finish and you will understand why

  • @jacobflanigan6343
    @jacobflanigan6343 2 หลายเดือนก่อน +2

    Nice Bosch install! I have seen you installed a Goodman before due to a footprint issue for a Ruud

    • @ryanwoods4691
      @ryanwoods4691 2 หลายเดือนก่อน +1

      Bosch is awesome, pretty sure they’re based off of midea units, but hey, they’re great

  • @spartin86
    @spartin86 2 หลายเดือนก่อน

    I dig these extensive installs. Busy busy
    That has got to be pricey job.

  • @Demy26
    @Demy26 2 หลายเดือนก่อน +1

    Steve, Certified Bosch Installer

  • @cardo1111
    @cardo1111 2 หลายเดือนก่อน +1

    Congrats on a well-deserved 200,000 subs 👍🏽

  • @frankrizzo3915
    @frankrizzo3915 2 หลายเดือนก่อน +3

    Nice Work Steve!

  • @paulpatenaude3208
    @paulpatenaude3208 2 หลายเดือนก่อน

    Excellent installation, nice heat pump base outside!

  • @user-de8fi2ih3s
    @user-de8fi2ih3s 2 หลายเดือนก่อน +2

    Great job Steve !!!!! as usual...

  • @jeffdickens7019
    @jeffdickens7019 2 หลายเดือนก่อน +1

    Good job Steve as always

  • @b.powell3480
    @b.powell3480 2 หลายเดือนก่อน +4

    Hi Steve, great job!, however, how come you can't do the electrical work for the A/C units ?, seems that you have the expertise instead of having to hire an electrician and wait on them before you can finish the installation! In California, the HVAC guys/gals can get an electrical license to add to their HVAC license and do the electrical work as well

    • @WeatherNut27
      @WeatherNut27 2 หลายเดือนก่อน +2

      He's not licensed for it but I agree, if he knows how to and its not getting filed then he could. I bet he had to file the job though.

    • @jonsaircond8520
      @jonsaircond8520 หลายเดือนก่อน

      Liability would be the primary reason weather its a permit job or not. If your not licensed to do it and something happens the General Liability insurance gets pretty foggy. It isn't worth losing your insurance and nobody else will pick you up now your out if business to run 1 electric line. My younger years I did it all the time but things are different now

  • @scotthill1278
    @scotthill1278 2 หลายเดือนก่อน

    Wow that thing runs quiet. Great install.

  • @justmc62
    @justmc62 2 หลายเดือนก่อน +1

    That outdoor Stainless Steel service disconnect cost more than the Bosch unit ... Must have fell of a truck ..LOL

  • @christopherreus7799
    @christopherreus7799 2 หลายเดือนก่อน +1

    2.0 awesome Steve more electronics no you don't like that 😂 nice job Steve

  • @timothyfink9354
    @timothyfink9354 2 หลายเดือนก่อน +2

    another quality job done.

  • @stephenbullock-yn3vh
    @stephenbullock-yn3vh หลายเดือนก่อน

    You should have put the low voltage wire by air handler in conduit to keep the rodents from chewing on the wires

  • @MaMa-qh4dy
    @MaMa-qh4dy 2 หลายเดือนก่อน

    GREAT WORK STEVE! Thank you for sharing.

  • @picklerix6162
    @picklerix6162 2 หลายเดือนก่อน +9

    Don’t forget to install a surge protector on the power line to these units. A power surge will destroy the sensitive electronics in these heat pumps.

  • @pridemechanical815
    @pridemechanical815 หลายเดือนก่อน

    Your an HVAC entrepreneurial hero!

  • @iamnoone.
    @iamnoone. 2 หลายเดือนก่อน +1

    Howdy Steve and Miss Molly

  • @CBSBKKAMcomputerhelp
    @CBSBKKAMcomputerhelp 2 หลายเดือนก่อน +5

    Congratulations on 200k subscribers

  • @johnwalker890
    @johnwalker890 2 หลายเดือนก่อน +1

    Great job Steve.......

  • @matthewsfather
    @matthewsfather 2 หลายเดือนก่อน

    Embrace the Technology Steve!!

  • @michaelrousselle6080
    @michaelrousselle6080 2 หลายเดือนก่อน +1

    mike pipes is starting s--t again, i like your work and your prices

    • @Stang281472
      @Stang281472 หลายเดือนก่อน +1

      Steve Lav still lives in Mikey Pipes head rent free

  • @WoodisGood82
    @WoodisGood82 2 หลายเดือนก่อน

    That was a hot job mama! Great work as usual.

  • @TruckguyTruckguy
    @TruckguyTruckguy 2 หลายเดือนก่อน

    O Shit Steve hittin the Bosch!!!!! Zack Psioda and Ralph Wolf approved!

  • @mydogpeaches1
    @mydogpeaches1 2 หลายเดือนก่อน

    that bosh really looks like good equipment i have heard good things about them as well it will be interesting to see how well they hold up

    • @tc6580
      @tc6580 2 หลายเดือนก่อน

      A friend of mine has a Bosch 7yrs old last year A coil leaked this week inverter and board burned up so bad they had to replace the condenser unit. $7500 for repairs in 2yrs.

  • @user-jw1ee6wl1c
    @user-jw1ee6wl1c 2 หลายเดือนก่อน

    Nice professional job Steve!

  • @extremegaming2280
    @extremegaming2280 2 หลายเดือนก่อน +1

    If it fits, it ships! The GODZILLA work truck

  • @michaeldaamen1436
    @michaeldaamen1436 หลายเดือนก่อน

    Thank's steven
    love your vogs 😀

  • @mikem8563
    @mikem8563 2 หลายเดือนก่อน +6

    Flippin made in china

  • @old1234
    @old1234 2 หลายเดือนก่อน +1

    Nice Bosch unit

  • @sammyc3726
    @sammyc3726 2 หลายเดือนก่อน

    nice work Steve, looks good

  • @tomdale1313
    @tomdale1313 2 หลายเดือนก่อน

    GUNSLINGER FOR HIRE', thxs for sharing...

  • @claudineyteles3496
    @claudineyteles3496 หลายเดือนก่อน

    Steve is the man go miss moly 😊

  • @discoveryman59
    @discoveryman59 2 หลายเดือนก่อน

    Wow thats a NICE system!

  • @joelochoa4038
    @joelochoa4038 2 หลายเดือนก่อน

    Great job Legend!👍🤘

  • @shoretrade9516
    @shoretrade9516 2 หลายเดือนก่อน

    Steve’s working hard on this one. Changing out that train system for a Chinese Bosch.

  • @jo6520
    @jo6520 2 หลายเดือนก่อน

    Looks good, steve!

  • @johnnicatra570
    @johnnicatra570 2 หลายเดือนก่อน

    Great job

  • @deanmartin1966
    @deanmartin1966 2 หลายเดือนก่อน

    Nice install

  • @psanchez1981
    @psanchez1981 หลายเดือนก่อน

    Ok Mikey Pipes could learn a thing or two 😂

  • @HERITAGEWV
    @HERITAGEWV หลายเดือนก่อน

    We all knew Mikey was going to have something to say about Steve installing a Bosch.

    • @charlessullivan1504
      @charlessullivan1504 หลายเดือนก่อน +1

      There both good plumbers different ways of doing things but yea no need to be throwing jabs at steve

  • @tonym6920
    @tonym6920 2 หลายเดือนก่อน +7

    Hey Steve and Miss Molly! Workin’ again ya’ll. 👍👍

  • @nisw1918
    @nisw1918 2 หลายเดือนก่อน +1

    Techs should study how you deal with the public .

  • @marionmitchell261
    @marionmitchell261 2 หลายเดือนก่อน +1

    Midea makes Bosch. They are very well built units.

  • @rodneyskinner7741
    @rodneyskinner7741 2 หลายเดือนก่อน +4

    Hello Steve!

  • @ClickinChicken
    @ClickinChicken 2 หลายเดือนก่อน +2

    The Tires Plus guys, fixed my front suspension today! I had a local guy replace a broken spring then springs(struts) in May, Turns out there were three nuts and bolts half on! He's right, I don't hear the clunking anymore! Good news day. 75 bucks!

  • @nifethrubutter
    @nifethrubutter 2 หลายเดือนก่อน +1

    Hey Steve I thought you didn’t use stabrite anymore?

  • @robertblacksmith4355
    @robertblacksmith4355 2 หลายเดือนก่อน +1

    Same ppl that don't change engine oil & run them dry with no oil! Rich don't care they buy another one!

  • @danwittels5542
    @danwittels5542 2 หลายเดือนก่อน

    The ooold American Standard ya'll!!! She's a leaka mamma! 😅

  • @bruceorourke5432
    @bruceorourke5432 หลายเดือนก่อน

    The made in China are Singapore check to see where they're made

  • @marty0715yt
    @marty0715yt 2 หลายเดือนก่อน +1

    Hey Steve-- how many amps is that unit pulling?

  • @wigglesyt5067
    @wigglesyt5067 2 หลายเดือนก่อน

    @22:03 it's like a horror movie

  • @jaykim1071
    @jaykim1071 2 หลายเดือนก่อน

    Ohhh, he soldered that thing

  • @onepingonlyvasily
    @onepingonlyvasily 2 หลายเดือนก่อน +4

    Nice Made in China sticker😬

    • @tedbell4416
      @tedbell4416 2 หลายเดือนก่อน +2

      Nothing but quality here

    • @davidnorton5887
      @davidnorton5887 2 หลายเดือนก่อน +2

      Good enough for this liberal neighbourhood.

    • @hvacslayer2929
      @hvacslayer2929 หลายเดือนก่อน

      Mikey douche pipes wears those Bosch shirts with American flag on it 🤦🏻‍♂️

  • @kaib1125
    @kaib1125 หลายเดือนก่อน

    IT'S D O A IM AFRAID

  • @john7017
    @john7017 2 หลายเดือนก่อน

    You can pull a Trane!

  • @josephgraham1065
    @josephgraham1065 2 หลายเดือนก่อน

    Just curious why are the line sets brazed or soldered on central ac units but mini split systems use flare connections? Same pressures arent they?

    • @mrlegendary9298
      @mrlegendary9298 หลายเดือนก่อน +3

      @josephgraham1065 If brazing is not done properly with nitrogen flowing, you can get cupric oxide which is a black soot inside the lineset. Mini splits don't use filters like split systems and the soot can create issues with the metering valves etc on the mini splits. So they use flares. Also, the history overseas of mini splits was geared towards homeowners/ non professionals doing the installs and not having the equipment to braze properly led to use of flare fittings.

  • @nickserafini1875
    @nickserafini1875 2 หลายเดือนก่อน

    Even the MassHoles can learn!

  • @joelmartin5316
    @joelmartin5316 2 หลายเดือนก่อน

    It's me mf.. king Steve Lav.

  • @ryanboutr7756
    @ryanboutr7756 2 หลายเดือนก่อน +4

    Flux and solder on 410a lines is not the best choice, r22 sure, but 410a is a little sketch

    • @tedbell4416
      @tedbell4416 2 หลายเดือนก่อน +2

      It's fine

    • @ryanboutr7756
      @ryanboutr7756 2 หลายเดือนก่อน

      @@tedbell4416 debatable

    • @mrlegendary9298
      @mrlegendary9298 หลายเดือนก่อน

      Read up on Stabrite 8 and its max operating pressures. Its plenty strong and less chance of cupric oxide forming inside the lines due to its low melting point

  • @stevenzembriski6761
    @stevenzembriski6761 2 หลายเดือนก่อน

    Bosch that’s German engineering 😮

    • @davidnorton5887
      @davidnorton5887 2 หลายเดือนก่อน +1

      German engineered in Chyna. lol.

  • @rrbigdad
    @rrbigdad 2 หลายเดือนก่อน

    What system do you like

  • @HERITAGEWV
    @HERITAGEWV หลายเดือนก่อน

    You can’t go off looking at the 2 double pole 60A breakers to solely determine if it’s a 10-15-or 20kw electric heat kit.
    Pop the cover off of it, look at the heat kit. It should be labeled but if it’s not you can look at the front of the heat kit and simply count the sections or thermal overloads. 1 thermal overload per section and typically each section is ~5kw
    1=5kw
    2 =10kw
    3= 15kw
    4= 20kw
    Oh and the 2 breakers on the heat kit should already be set to run the blower motor also.
    Circuit #1 will run the blower, low voltage transformer and part of the backup heat. The 2nd circuit runs the remaining heat elements.

  • @anthonyelectric6045
    @anthonyelectric6045 2 หลายเดือนก่อน +1

    Steve was that an inverter system?

    • @jph77
      @jph77 2 หลายเดือนก่อน +1

      It is.