compressor tripping problem, thodi der compressor chalta hai band ho jata hai, compressor heat Kyu h
ฝัง
- เผยแพร่เมื่อ 23 ธ.ค. 2024
- compressor tripping problem, 5 minutes chalker compressor band ho jata hai, compressor heat kyu ho rha hai, compressor jada ampare kyu le rha hai, compressor Strip problem, ac thodi der thanda karta fir garam hawa fekne lagta, compressor kaise check kare, ac condenssor flushing, capillary aur filter kaise change kare, ac thanda nahi ho rha kya kare, ac garam hawa fek rha hai, ac ka compressor kaise check kare, ac choke ho gayi kya kare, ac me gas kitani honi chahiye, patel and brothers, patelandbrothers, एसी बार बार ट्रिप कर रहा है,
एसी का कम्प्रेसर हीट हो रहा है, पटलपटेल ऐण्ड ब्रदर्स, compressor heat problem in fridge, compressor heat kyu hota hai in hindi, compressor garam hoke band ho ja rha hai, compressor thodi der chalta hai band ho jata hai, compressor se awaj aa rahi hai, compressor heating problem, compressor nahi chal rha hai, compressor animation working, compressor heating fridge in English, compressor heating , ac ka compressor trip ker rha hai, fridge ka compressor trip ker rha hai, ac on hote hi voltage drop hota hai, ac chalu hota lekin thanda nahi karta,ac compressor tripping problem
types of Compressor
• Types Of compressor#कम...
relay kya hoti hai
• रिले क्या होती है, रिल...
refrigeration cycle
• रेफ्रिजरेशनसाइकिल# ref...
Working Of Compressor
• Working Of reciprocati...
relay ka connection
• रिले का कनेक्शन कैसे क...
hvac plant
• HVAC Plant# चिलर प्लां...
very knowledgeable video and super uploading, Bhai very helpful for RAC engineer who are fresh in RAC line
👍👍👍👍👍👍👍👍👍👍👍👍
Hi , I am working on Power and Air conditioning system from last 19 years in Defence, you explained all related faults very clearly, correctly and in a very cool manner that I recollected my 19 years experience during your video. Kudos..for the great work
Thanks 🙏
Can I get ur number
Maan gaye bhai sahab....agar aap k jaisa technician mil jaye to kabhi bhi bina ac k nahi sona padega.
@@armysoldier8980 gas low triping main reson power ampr checking durtok pm main gas los back prssure come ok cleing filter amper checking gas look gas tomuch tipinv hot and
Samjhane ka Tarika bahut achcha hai ful jankari ke sath ek Salah samjhane ke liye aap Jin shabdon ka istemal karte Hain UN shabdon ko Hindi aur English donon ka prayog Karen
Thanks for your valuable advice
Sir app bahot acha samjha rhe ho
Very nice explanation...👌👌👌
Bhut hi acche se btaya apne
Subscribed. Nice Video good information and very helpful
Best explained... Great job.
Brother aapke sare video gajab hain
Amazing information 😮
graet points Sir, keep it up
Great video plz.stay connected
Thanks
Aap ke tips buhat umda aur karamad hote hain,
MERA SPLIT AC 1 ya 2 Ghante tak chalne ke baad tripp hojata hai, specially dopahar 12 ya 1 bajay ke baad trip hota hai, bus fan chalta hai. Mehrbani kerke mere problem ko point out kerke solution bataden. Thanks.
Dopahar me bahut dhup hone ke karan aapka compressor band ho jata hai ager direct dopahar ki dhup aapke outdoor per pad rahi ho to us per kuchh chaanv ker dijiye
Bahot badhiya bhau
Nice video, Hitachi Window AC switch off automatically at night, works fine during the day. Filter was dirty blocking the airflow.
Subscribed 👍
poora ac band ho jata hai ya sirf compressor
@@patelandbrothers Sirf compressor
aapka compressor kafi der chalne ke baad heat ho rha hai service na hui ho to karwa lijiye, room poora packed hona chahiye, aisa bhi hai kya ki night me light ka voltage kam hota ho
Thank you for your valuable feedback and advice. Service could be the culprit behind the anamoly.
@@patelandbrothers hmm
Good work man 👍🔔🙏wapas
Sir please mujhe koi batado mujhe mera window ac kharab krna h new tbhi milega
Aag laga do shli main
Great video, keep it up👍 ur new frnd here😊
बहुत ही बढ़िया सर
Very helpful video 👌👍
apne dusare mobile se bhi ker diya
Buhat acha 🌹Mene ap ko dust bana liya🌹
stay connected permanent
Very good 👍🌹
Very good information sir
Thanks bhaiya ji
Supper voice 👍
th-cam.com/users/shortsVhp07307c9Q?feature=share
Super hota hai... Supper nhi.... Supper nashta hota hai
❤️❤️
Ek jankari Den please old model dedh tan ka window AC hai Lancer ka kya uska compresser Badal sakta hai
Haa reciprocating compressor lga dijiye
Thank you so much for this important information
Good experience and good explanation
Thanks bhai 🙏
Good information 👌👌👌
SAHI AC ENGINEERING PAHLI BAR YOU TUBE PAR MILA MUJHE THANK ALOT🙏🙏🙏🙏🙏
🙏🙏🙏
Bahut hi achcha bataaya sir
Thanks sir ।
very सुंदर 👌
Good knowledge bhaiya ji
Thank You 🙏
Very nice 👍👍👌👍👍 bro
Sir Meera window ac Lloyd ka hai raat koo kuuch deer ke liiye kabhi kabhi automatic cooling aani band ho jaati hai or phir auto chaalu kya ye common hai yaa koi problem ? Pls reply sir it's urgent I am a first user of an ac
Kabhi kabhi bahut garmi hone ke Karan compressor overheat ho jata hai to trip ker jata hai jab compressor trip Hota hai to us samay cooling normal ho jati hai. Yr normal cause hai ager aur jada problem kare to comments kariyega
Good video Allah apko tarriqi de
Sir Agar PCB nor working properly to bhi compressor trip hoga kya ..same problem 5 minut nice cool but then compressor trip and normal air flow...ols suggest
Sabse pahle aapko ye find out karna hoga ki compressor heat hoker band ho rha hai ya aise hi, 5 minute me trip ke baad kitni der me start hota reply
@@patelandbrothers अगर ट्रिपिंग के बाद खुद से ऑन नहीं होता है और अगर फिर मैं ऑन करता हूं तो ऑन हो जाता है लेकिन फिर ट्रिप कर जाता है तो क्या करना चाहिए?
हमारा स्प्लिट AC जो कि डेढ़ टन का है उसका कंप्रेशर 3 मिनट चलता है और तीन ही मिनट बन्द रहता है और अगर उसको ड्राई मोड में चलते है तो कंप्रेशर ठीक चलता है मतलब ठीक चलता है तो ठंडक भी ठीक होती है पर cool मोड 3 मिनट ही चलता है अगर ड्राई मोड में कंप्रेशर ठीक चलता है तो फिर cool मोड में दिक्क्त क्यों करता है ऐसा क्यों है जबकि बैक प्रेशर 65 है और स्टैंड प्रेशर 165 से 170 है
Indoor unit me 2 sensor lage hote hain usame se Jo copper wala sensor Hota Hai usko check karwaiye
Bhai same condition hai 4 mint on rhta hai aur 3 mint off rhta h
Mera indoor ac 7 minutes chalta hai or 3 minutes band rahta hai please bataye kya issue ho sakta hai ?
@@viknitu1 same issue. But mere me yeh tab hota jab gas low hojati.
Bahut badiya bataya
Lloyd window AC purchased 2 yaers ago.kisi bhi temp pe set karne se 5-7mim chalke compressor band ho jata h bs fan chalta h.plz guide me
Sabse pahle ye find out karna padega ki compressor senssor se band ho rha ya high ampare hoke tab hum kuchh bta payenge
thank u very much. you r sooper.
Sir i have lg 1.5 ton ac its compressor is tripping …first cycle it run for 10 min and then it gets trip within 4 min and again cycle goes on….the room temp is always plus 2-3 degree
What was the problem? How did it got solved?
Best explained
Thanks
Indoor to outdoor coppr pipe conection ager 3 feet ya esse kam ho to koyi dikkat hota hai kya
Haa discharge pressure badhane lagta hai, jisase ac thodi der chal chal ke band chalu hota hai,
Thanku👍
So beautiful.....🤩🤩🤩
Sir app se ekk questions hai mujhe batao ki gass charges me kon line khan use hoga sir please tell me sir please me isme bahot jda confused hun sir please
Gas charging hamesha low side se karte hain Matlab aapko gas charging ke samay suction line me charging line ko lgana hai ya fir aap aur kuchh confuse hain to poora question likhe
Sir me appse ye puch rha hun ki har gash alag alag hota hai to gaisline jo hoti hai wo alag alag lagti haina to wahi me puch rha hun ki kon se gash me kon line lagega sir
bhai aap bhut gret ho
Very nice suggestion
👍👍 akdam 👍👍
Sir hamera room pe mitsubishi heavy industries ac lga hua hai usme compressor drip kr rha hai toh plzz aap btaye kya kre
Hmne kisi wrkr ko bulaya usne bola gas km haii
Aab toh gas b dalva lyi fr b same prblm a rhi haii
Plzz suggest kre
Boht pareshsn hai hm
Sari raat bche so nhi pate
Kitane minute chalne ke baad trip Hota hai
@@patelandbrothers 3-4minutes
good information 👌
good and very useful video
Very Good Information Sir Ji
New compressor daikin non inverter ac 1.5 ton me kuan sa dlbaye
Non inverter hai koi bhi dalwa lijiye,
Useful tips
Thanks sir. Good
Sir want to talk with you regarding window ac if possible pls help and guide ...
9009121933
Shabash bahut achha
Plz Sir iska ans dijiye mechanic bulata hu sub alag alag preshani btate h
Bhai ji please suggest Karo : Mera Whirlpool split 1.5t ac trip karta hai. Actually kuch din pahle condenser change hua tha uske baad se hi ye dikkat aani shuru huyi hai. 10-15 minutes chal ker trip ho jata hai. Or ampere bhi jyada le raha hai ab. 1900watt tak bhi ja raha hai load ab. Pahle gas Kam Kari thi technician ne fir sahi chalne lga tha load bhi 1250 watt lene lga tha per cooling nahi ker rha tha. To dobara gas daali per trip ker rha hai load 1800-1900 watt le raha hai. Ac ka load actual me 1450 watt tha papers me catalogue me waise
Gas dalne se pahle sahi se vacuume liya tha ya nahi
Aap mumbai se hai kya bhai
No from Lucknow
Sir mene lloyd ka ac new liya ha 1.5 ton inverter.. me 28 pe chalata hu to 5 10 min cooling krne ka baad compressor off ho hata ha normal hai ya koi problm ha sir ..?
jab room ka temperature badhta hai to fir compressor chalu ho jata hoga waise koi problem aapki ac me nahi hai fir bhi aap neeche link per jaker video dekhiye poora process samajh jayenge,
th-cam.com/video/LIcvENp1rxQ/w-d-xo.html
@@patelandbrothers sir ek or problem ha ac me .. chill mode pe itna cooling nahi krta jitna dry mode pe krta ha dry mode pe bht jyada colling krta ha
Mera ac haire ka ha 18000 btu vo sirf 30 secnd chalta ha or us ka compreser band ho jata ha ma nay us ka raning copester bhi chanj kiya magar vo phir bhi 7 empaer lay kar band ho jata ha us ka kiay fold ha????????? Plz reply
jab ompressor band hota hai to fan cbala karta hai ya wo bhi band bo jata hai
Good very nice knowledge
@jaiprakashyadav9902 sir blustar 1.5 ton ka split ac h 4 mint chalta h aur 3 mint off rhta h sir kya reason ho sakta h plz rply
Poora off ho jata hai ya sirf outdoor
@@patelandbrothers sir sirf out door har koi alag alag salutations bata rha h aap bataiye kya problem ho sakti h sir 😞
@@sahilchamp1012 indoor ki cooling coil me ek senssor lga hoga usko coil se nikalker matlab bina coil me tauch kare tab chalaiye aur btaiye kitani der chalta hai, ek senssor cooling coil ke bilkul front me rahta hai usako nahi doosra jo pcb lagi hoti hai usake pass uper coil ke ander dla hoga senssor bhi copper ka hi hota hai usako
@@patelandbrothers ok sir shukriya rply dene k liye kafi time se main pareshan hu is problem se ....
@@patelandbrothers sir coil sensor hata k check kr liya abhi bhi wahi problem face aa rhi h but ab compressor 3 mint se badh kr 6 mint chal rha, 3 mint band rhta h
sir pcb check krare kya
sensor v bad gai h......ya relay kharab ho gai h 3 mint me suply cut kr rahi...... Ya kahiye to 1 baar capister change kr k dekhe aap suggest kriye kiya kre .....
30 like, very nice
Very nice explanation
Sir mere 2 ton ke compressor ke copper or compressor ke cyclender per licked current aarha ha ky problem ho sakta h ?
Compressor per terminal lage hote hain unko check ker lijiye kahi Compressor ki body se touch to nahi ho rahe hain
@@patelandbrothers or sir mene 450 v supply per lagaya hu shop per kahi usse tho nahi ho raha hoga ?
ekdomi sach bat thanks sir
Siplet ac ki secshn or discharge heet kb hoti h
split ac ka suction aur discharge line heat nahi hoga, ager outdoor open karke bilkul compressor se jo discharge line nikalati hai usako tauch karoge to heat rahega waise aapke ac me problem kya hai
Hello, LG non inverter split 1.5 AC, compressor trip problem, 5 min chalta hain uske baad band ho jata hain, no cooling only fan running, service karwa li, capacitor change karwa liya, kya problem ho sakti hain, pls guide, outdoor unit chanv main hain
De.
Jab 5 minute chalta hai toh cooling hoti hai aur ampare metre lga ke check kariye jab band hone wala hota hai toh us time ampare kitna hota hao
Right sir capillary problem hai
Very useful video👌🏻👌🏻👏🏻👏🏻
Great information thanks for sharing 👌👌👌
th-cam.com/users/shortsVhp07307c9Q?feature=share
knowledge hai bro
Aapko ek point aur add karna chahiye tha ki ager compressor me oil kam hoga to bhi compressor heat hoga
Lakin bhai ye sautition bhoot km aati h
You Are Gujrati?
no im am from lucknow Uttar Pradesh
Super knowledge
Sir namaskar ji career window AC durakool on karnaka bat cameras on nahi hota he triphotaha kiya karonga
mera Super general split ka outdoor dhad dhad karke din mein bandh hora tha, urban clap se technician ko dikhaya usne poora service kiya...uske kuch din baadh theek chala...ab firse sane problem ab toh raat mein bhi hora hain...mujhe stab mein voltage magar 80 ke niche uska kaanta dikh raha...kya problem ho sakta hain.. please reply
Aapke yha wining me kahi loose contact hai ya kahi se Volta dropping ho rahi hai
@@patelandbrothers technician ne ac poora check kiya acche se outdoor unit ka capacitor aur sab kuch...sab thik hain...par usne bola high ampere outdoor mein aara hain...isi wajah se outdoor unit heat hoke bandh hota hain..khass karke din mein..magar kal raat mein bhi ho gaya yeh...aur mera stab 80 mein uska point hain ruka huwa...toh ac thik hain?? Voltage ya stab kharab hain?? Thanks for the reply
@@Fusionplate aap ek bar Bina stabilizer ke chla ke check kariye ager stabilizer voltage jada bnayega to bhi ac band ho jayega
@@patelandbrothers ji maine bina stab ke chalaya...thik chala..toh kya problem so sakta hain stab mein?? Pps reply
Sir
I hve 1 split 1.5t ac
Its work f9 in night and taking mor amp asss compair normal.
But in day its trip aftr 20mnts
What problm in my ac?
Direct sunlight on the outdoor unit reads that if this happens, the discharge pressure of outdoor increases due to direct sunlight, the compressor gets heat due to increase in discharge pressure,this is normal case
Sir mera haier ka 1.5ton window ac h yei cooling to krta h but kbhi kbhi cut ho jata h compressor jhatke sei aur fir ac band krke backside paani dalke ac cooling achi krta h isme kya problem h iski service krva kei sahi hojaega ya koi aur issue h
Service karwa lijiyega aur voltage check karwaye ki kam jada hota hai kya
Humne nya ac khrida h hitachi ka 1 ton ka 5 chlta h phir compressor down kya kre sir
Aapki ac abhi waranty me hai isliye aap company ko complain ker dijiye
@@patelandbrothers garanty m h sir
Very nice video
Sir mera o carrier 1.5 ton ac, Once ac on kare after 10 mini AC automatically totally off then automatically on
whats is the problem sir plz bathaye
Ho jayega sahi
Sir dubbal door fridge ka kam cooling me kya kya problem ho sakti hai pleas ek video banaye
Sir, humara lg ka ac hain usme outdoor unit jab band hota hain to jor se khattt.. esi awAz ati he , to kya problem ho sakta hain? Plz bataiye
compressor 3 nut bolt se bandha hota hai un nut bolt me rubber ke gromet pade hote hai kahi wo gromet kat to nahi gaye
Brother isme pcb ki bhi problem aa skti h
waise pcb ki problem aayegi to compressor 5-10 minute nahi chalega ha ye ho sakta hai ki jo pcb me temprature sensor lga hota hai wo fault ho,
Sir pichle 1 mahine se split AC only 5-10 minutes chalta hai phir baad mein cutoff ho jata hai.... phir 1-2 ghante bandh rakhne ke baad phir 5-10 minutes chalegaa phir cutoff ho jata Bahar Outdoor Unit par haath lagaya toh bahut zyadha garm ho raha tha .kal koi technician se AC ki service bhi kara li,Condenser bhi change karwa liya or Rely bhi change karwa li par kuch bhi nahi hua ....sir please bataiye ab kya kara jae???
Puri gass nikal ker capsliry change karwake achche se vaccume karwaker wapas fir se gass dalwaiye
3 like
very very thank u guruji shukriya
Fan speed compressor low after 15 minutes
Sir ji lg inverter tower ac ka compressor 1minat chal kr trip ho rha hai karan bataye
Kitane ton ka machine hain koi alarm bhi ata hai kya
@@patelandbrothers nahi na koi Alarm na koi error code
@@ishanhashmi8719 three phase machine hai ya single phase three phase ho to contactor check kariye
@@patelandbrothers single phase hai sir ji or uske pcb me cotactor nahi hai
Bus self vaccum ke gais charge kiya tha
Sir please answer me.ager koi 500 ton ki chiller ho centrifugal or us me 134a gas hoto to wah chiller kitna pressure pe jayega to LP or Hp pe trip karega ..last pressure Kya hoga dono situation me.
134a gas hai to hp 150+ psi per hold ho jayega ager pressure controll ho gya to theek otherwise 160 psi pahuchate hi chiller hp per trip ho jayega, aur LP 25 per low Evapurator prassure per hold rahega, control huwa to theek otherwise 22 psi ke neeche jate hi low Evapurator prassure per trip ho jayega, ye lagbhag sabhi company ka parameter hota hai,,
@@patelandbrothers thank you very much sir Dil se..Mai bahut paresan tha is ke liye..
no thanks plzz subscribe my channel 🙏🙏🙏
Nice keep it up
Sir mere pas 1.5 ton window ac. H. Ac 6 min tk shi chlegi uske bad 3 min k liye trip ho jayegi. Kya problem h bhai ji. Please btaye
grill kholker dekhiye coil me senssor laga hoga us senssor ko coil se hataker hanth me pakadker rakhiye phir ac chalaiye aur dekhiye kitani der chalta hai
Good hints🙏
Mera window ac h line toh thk h par ac chalta h phr slow ho jaata h phr se chalta h phr compressor slow ho jaata h ..earthin ka prblm bhi ho sakta h kya..kyun k jahan se earthin liya h woh line me bohat load h
Haa ager voltage 190 volt se kam ho jata hoga to bhi aisi problem aati hai, night me jada problem hoti hai kya
@@patelandbrothers din me hota h ..neutral kya hota h sir
@@nazranaislam7908 aap ac chalu rahte hi voltage check karwaiye
Very Good