Air in system....if not purged properly or vaccumed properly while charging refrigerant can also result in frequent high pressure trip of ac ...as air wil not liquify like refrigerant and wil put excess load on compressor...this usually happens on big central ac systems ... 12 th point ..nice video ...covered all technical points
Zyada heat wala area jaha sun light direct ho ya fir zyada garmi ke sizen me for example march, April, may tab bhi compressor thodi Der heat hokar trip ho jate he
## outdoor unit me fan capacitor change Kiya ho to same value kaa Karna prega for example Samsung ke outdoor unit me 2.5mfd Ka capacitor change krke 3 ya 3.5 mfd Ka dalnese kuchh ser baad compressor band hojati he
Sir aaj he ac lagwaaya aur ac chalte chalte cool nho kr rha fir thoodi dher baad coolong kr rha outer bnd ho jaa rha fir start ho jaa rha log bol rhe. Voltage ki dikkat hai bt main circuit me staplizer laga hai 250 volt aa rha fir kyu aisa ho rha
Sir panasonic ka ac h Or vo evening ke 6 pm se le ker morning ke 9 am tak badiya chalta h But afternoon me vo chalta tho h but hot air detha h Ac wale ko dikhaya tho vo stabilizer change kerne ko bol reha h Aap ke points mughe ache lege Tho kya aap mughe iska reason betha sakthe ho
Voltas packaged air conditioning model Dpua sc 1700 is AC mein error code aata hai co and ul Rajkot aane ka bad cooling system band ho jata hai kyon kya iska Mane iska ful form kya hai kya check karne se aisi solve Kiya jaega
sir ek split ac h...panasonic company ka...usme ac chalta hai sahi cooling karta hai aur amp vo sahi le raha.5-6amp h ..Gas vgera sb ok hai magar 30mint chalne k bd...ac cooling dena band kar deta hai lekin compresure band nh hota...compressure or fan dono hi chal rahe hote hai....aur amp jo hai 2.5amp ho jaate hai..fr uske bd amp badhte nh hai or dono ac ke suction or discharge pipe garam ho jaate hai mtlb normally garam...hote h.....or fr 30mint baad ac ko off kr ke chalate hai to fr ac thk thaak chalne lagta hai aur amp bhi 5-6 aajate hai..to esme kia dikkat aa rh h...ki compresure k amp 2.5 amp ho jate h mgr cooling b bnd ho jaati h mgr compressure chalta rehta h btaye sir
Ac ko dobara chlane k baad hot mode me chla jata h 4-5 baar reset krne pr cooling dene lag jata jaise hi supply jati h hot air dene lag jata please reply split ac duel inverter h
Sar voltas d.c invetor ac ha koi error nahi a raha ha 2 mint chalta ha out door band ho jata ha fer 3 mint baad on ho jata ha out door fer band ho jata ha kya problam ha sar usme
Bro caarier ac main indoor unit chalta h Or compressure m chalta h. Kuchh time 10 minute chalta h. Indoor unit autometic off ho jata h indoor unit display light blinking hota h continue 1 minute.fir 1 minute k baad light blinking off ho jata h fir indoor chalta h.or pcb new lagaya. Gas thik h. Jaisa timer set ki tarah hota h.
Mera blue star ka 1.5 ka ac h uska compressor kuch time chalne k bad trip ho jata h or indoor se garam hawa ane lagti or compressor dhere dhere chalta rahta h kuch time tak ism kya problem ho shakti h
Mera mitsubishi heavy duty srk18yvs w6 split ac hai. Chalne ke 10-15 minute baad cooling band ho jati hai aur green led light 6 times blink kane lagti hai. Kya reason ho sakta hai.
## Purane models me ek case paya tha ki jab swing flapper motor jam Hoti he tab blower motor ki speed bhi Kam kardeti he uski Bina se coil thandi hokr sensor se compressor trip karwati he. Swing flapper motor kaa socket Nikal dene se compressor ok chalta he, reason wohi tha ki swing motor purani hone se jyada load le rahi thi.
Sir ji mera ac 1.5ton ka hai din me ek bar cooling kane ke bad dubara cooling start nahi hoti hai par raat me bikul thik kaam karta hai kya problem hai.
Mere O general ka 1.5 ka window ac hai 2 year phele purchase kiya tha aur ab cooling problem aari hai . 10 minute cooling krta hai uske baad nhi krta. Phele ek service wale ko bulaya usne bola gas leak ho gyi .gas dalni padegi . Durse service wale ko bulaya cross check krne ke liye to wo bolta hai ki jb meter se check kr rhe hai to reading 200 dikha rha hai aur stabilizer mai 220 dikha rha hai .ho skta hai stabilizer mai problem ho kyuki ye thoda heat bhi ho rha hai . Mujhe koi btaye aesa kyu ho rha hai . Reply plz zzz
Our Hitachi 1.5 ton window ac 3 star after 2 or 3 hours it becomes jaam, then we stop and restart after 20 minutes, it works again. But it jaams again after 3 or 4 hours. What is this.
Cassette AC hai uska main sab kuchh ok gas bhi ok hai condenser heating bhi achcha Nikal Raha Hai per cooling nahin kar raha hai to kya problem ho sakta hai please batao bhai
## outdoor unit ka upper side Ka top laga hua naa ho, wo open ho tab bhi compressor thodi Der baad bnd hota he ese case me compressor khrab hone ke chances zyada hota he
Mera 1 ton ka AC hai Panasonic company ka AC chalu karne ke bad thodi bar cooling hota hai aur bad mein uska jo temperature ka indicator hai usmein se Lal light blinking hoti hai aur bad mein aisi automatic band hota hai iska kya problem hai aap bata sakte hain kya dhanyvad
Mera lg inverter AC h jo ki high cool pr chalane pr bhi room temperature Kewal 32 hi rakhta h iska kya karan h machenic ko dikhaya sabhi sahi bta rhe h lekin cooling proper nhi h
Hitachi inverter split AC ka compressor din me bar bar (20-25 sec bad) tip kar raha hai, or kuch der bad outdoor and indoor dono bandh ho raha hai 4 time blink ke saath. lekin raat me bilkul sahi chal raha hai. Iss ka Karan kaya hai...
sir mere pas window ac h ac wala bhai service krke gya tha oske baad se jb bhi cooling aani start hoti h to voltage km ho jata 194 tk oske baad grm hwa aata h sir please btaye kra kre ac wala bhai bhi fon nhi otha raha vo to msg seen krke chhod de raha please please please sir
## inverter AC ke outdoor unit me condenser Pura clean he magar PCB area me kachra yaa rust laga ho ya Kisi ne wiring box khula rakha ho jisse kabutar ya Kisi birds ya insects ne kachra jama Kiya ho tab bhi 2 se 5 minutes compreeser chal Kar band kardega
ek help chaihiye thi mere yeha light bar bar chali jati hai kabhi aati hai kabhi chali jati hai aur air conditioner remote se on hota hai jaise ki raat ke 3 baj rahe hai light chli gyi fir mujhe remote se hi on karna padega kya yrr chahe mei soo raha hu khud Automatic on nahi ho sakti hai kya
Sensor problem sa outdoor on nahi hora agar blower motor kharab hogi thabi bhee outdoor work nahi karaga deepbtahoo transfarmar kharab hoga tbee outdoor on nahi hoga
Hello sir Mere window ac 1.5 ton me kabhi 5 minat kabhi 20.kabhi 30 me trip ho ja raha hai , 210 volt pe nahi chal raha hai agar 250 volt drahe hai to chal raha hai kuch help kare sir
Sir ac kabhi cooling kar rahi hai kabhi nahi kar rahi hai is topic ke upar video bana do or sir ac ki caplary or ac ki pipe kahi par bhi moisture choking ya oil choking ho to kaese findout kare ki ac me choking ki problum hai is topic par bhi video bana do plz sir - My name is Mohammad Adil
bhai ak or kami he wo ye he ki kayi war makenik jalwaji me oudur diwar par fit karti sameh dihan na dene par a c kaam nhi karta matlab ye hi ki jase diwar pe oudur lagaya to uski samne ki diwar dur honi chahiye kyunki pass hone se cumpresar war war tirip hoga
## compressor Ka pumping agar Kam hota he tab bhi thodi Der me band hojata he. For example aap khali system me compressor chalate ho agar usme Aapka pumping 300 se 400 tak aata he to ok he warna isse Kam ho or back pressure speed se down hota he tab bhi Aapka pumping low he
After running 2 to 3 hours out door fan is stop . Cooling is stop . After some time I start again than cooling is start What is the problem in my panosic inverter AC , please help me/guide
Aadha ghnta Ac sahi chlta h fer outdoor band ho jata h coil sensor badal dia ac service bhi krw di capacitor bhi badal diye fer bhi same issue h kya kare sir
## indoor unit Ka blower motor kharab ho ya jaam ho yaa shaft uski rouse ho chuki ho yaa blower se zyada motor gumti ho tabhi ye dikkat Hoti he coile thandi hokar sensor se compressor trip karwata he
## indoor unit me nut jaha se tight hota he Jo hissa spring se lipti pipe yaa fir kahi or Kisi piping se pinch ya pipe dab chuki ho to aap meter guage se pata krne par kanta up and down hota rahega stand by Nahi rahega tab bhi compressor thodi Der me band hojata he
Asslam alikumm sir Mera Kenwood AC h 10.mnt chlta h phir just hwa deny lgta coling khtm ho jati phir 10mnt bad coming start ho jati bht preshan main 1,5 daidh tun AC h Mera 23 hzar bil Aya h es bar plz help me
Sir hamara ac 2 ton ka h to Jab lae the tab to first day ko bahuthi Acha cooling ki this but uske second day se hi cooling kam hogai or jisse liyatha vo man hi nahi raha hai ki ac me koi khrabi h .
Bhai,unit start hone time compressor normal hoga,kuch time chalne ke bad, discharge pressure perfect hoga,Lekin suction reed problem se wo proper refrigerant suck karnehi payega,phir wo proper refrigerant discharge karega nehin, naturally cooling stop ho jayega,ampre below hote jayega . Reply jarur Dena bhai.
Mera ac 1.5 ton hai uska out dore thodider cooling karta hai aur badme turant band hota hai our uska picheka fan aur Indore ka fan bhi slow chalta hai please madat kijiye
## outdoor unit ka fan jiska wiring kisine Ulta Kiya ho for example motor se fan garam hawa bahar fekne ki bajay andar fek raha ho tab bhi compressor thodi Der heat hokar trip karta he
## inverter AC me mostly Panasonic me 10 minutes chalne ke baad " df" defrost me system deta he jisme pcb regarding issue rehta he agar dusri pcb replacement yaa repair karwani padti he
Assalam walekum sar mera naam Farhan Ali hai sar main Hyderabad se baat kar raha hun sar Mera aisi abhi new pack dabba hai Maine 10 din pahle lagwaya hai aur mera chalte chalte outer off ho jata hai iska kya reason hai aap mujhe aap reply please de dijiyega aur AC 1.5 ton ka hai aur cooling bilkul acchi nahin kar raha higher ka hai sar thank u so Mach
## inverter AC me outdoor unit ke sensor Kisi Tarah se kharab ho ya kisine kutar diye ho tab bhi compressor humming leke bnd hota yaa start Nahi ho pata he error dekar.
Sir ac adha ghanta chalta hai theek phir garam hawa dene lagta hai fir usko adha ghanta band karke chalate hai toh fir theek chalta hai kya problem ho sakti plz reply
## outdoor unite me compressor 5-10 minutes chalne par suction line par return proper aata hoga magar after 5-10 minutes compreeser ke piston ya michenism me kharabi ki wajah se awaaj karke band hota he or sirf fan on rehta he or suction line garam hojati he
Sir compressor ki registance kitni honi chaya 1ton ac and 1.5 ton split ac
Sir je mitsubisi ka split a/c me stabilizer se wiar ulta lagane par koi problem hogi ya nahi
Air in system....if not purged properly or vaccumed properly while charging refrigerant can also result in frequent high pressure trip of ac ...as air wil not liquify like refrigerant and wil put excess load on compressor...this usually happens on big central ac systems ... 12 th point ..nice video ...covered all technical points
Good added point ravi
Zyada heat wala area jaha sun light direct ho ya fir zyada garmi ke sizen me for example march, April, may tab bhi compressor thodi Der heat hokar trip ho jate he
Eska koi upaay nahi hai jisse hamara ac cooling kre
## outdoor unit me fan capacitor change Kiya ho to same value kaa Karna prega for example Samsung ke outdoor unit me 2.5mfd Ka capacitor change krke 3 ya 3.5 mfd Ka dalnese kuchh ser baad compressor band hojati he
please make a video of How VRF unit working principle?
Llyod 2 ton contractor wiring
E3 eroor code kya reasion ho sakta h
Sir ak sharp eco inverter ac hain o 4ams leka 5min Chalke compressor band ho ja raha hain ??plzz tell me sir ..
Check error code on display and if not showing any error code on display check ODU PCB light blink error
Mana ki compressor me ⛽⛽ r 32 ki jagha pe r22 koyi dala ho to
Sir aaj he ac lagwaaya aur ac chalte chalte cool nho kr rha fir thoodi dher baad coolong kr rha outer bnd ho jaa rha fir start ho jaa rha log bol rhe. Voltage ki dikkat hai bt main circuit me staplizer laga hai 250 volt aa rha fir kyu aisa ho rha
Same problem.. plz tell solution???
@@YashveerSingh-lp8gw bhai wo vintage ki he dikkat h ab ki personal stabilizer lagaao fir sayad kharab ho jaye
E 1 se bhi aise problem hoti h kyaa
Split ac k indoor unit me ice smoke ya grill se pani ata hai kiyon?Jabki suctii oressure discharge pressure ampere rating sab thik hai..?
Clean indoor coil & check blower speed
Sir evopretion kise kahete hai
Ampere ki deflection hote hai garm hava dena shuru kar deta hai A. C. Plz tell me how to rectify it
Sir panasonic ka ac h
Or vo evening ke 6 pm se le ker morning ke 9 am tak badiya chalta h
But afternoon me vo chalta tho h but hot air detha h
Ac wale ko dikhaya tho vo stabilizer change kerne ko bol reha h
Aap ke points mughe ache lege
Tho kya aap mughe iska reason betha sakthe ho
Same problem
New ac 1.5, ton Hitachi AC hai chalte chalte cooling chali gai kyak kare input stabLizer par 253 or op 238 hai
bhai jyada tar ac 45°© m cooling dena bhnd jr dete h ... is mamle m ogenral ac is best
भाई मेरे साथ ऐसा ही हुआ है वोल्टैज खराब है
@@sandeepbeniwal1995 it's need stable voltage
@@sandeepbeniwal1995 hmmm
Voltage problem hoti ha Blue Star 1.5 ton ac MA kitna volt ka staplizar lagya
Compressor me oil Kaisa dalenge
Sir refrigerant pressure zyada hone se bhi thodi der baad Compressor trip kar jata hai
Good
Point no 12 .Very good
Sir 5mint chlna Ka bad compressor band ho jata h new capater bi dak Ka dik liya liki problem solve ni Hua?????
Sir mera ac Hitachi ka hi duphar me garam hawa phekta hi new liya hi esa kyu 2 tun ka hi kya kami hi abhi 10 din bhi nh hue hi liyewe
Voltas packaged air conditioning model Dpua sc 1700 is AC mein error code aata hai co and ul Rajkot aane ka bad cooling system band ho jata hai kyon kya iska Mane iska ful form kya hai kya check karne se aisi solve Kiya jaega
Check pressure and evaporator filter and blower for any defect
Sir hvac ki videos milegi ky???
See videos on my channel
sir ek split ac h...panasonic company ka...usme ac chalta hai sahi cooling karta hai aur amp vo sahi le raha.5-6amp h ..Gas vgera sb ok hai magar 30mint chalne k bd...ac cooling dena band kar deta hai lekin compresure band nh hota...compressure or fan dono hi chal rahe hote hai....aur amp jo hai 2.5amp ho jaate hai..fr uske bd amp badhte nh hai or dono ac ke suction or discharge pipe garam ho jaate hai mtlb normally garam...hote h.....or fr 30mint baad ac ko off kr ke chalate hai to fr ac thk thaak chalne lagta hai aur amp bhi 5-6 aajate hai..to esme kia dikkat aa rh h...ki compresure k amp 2.5 amp ho jate h mgr cooling b bnd ho jaati h mgr compressure chalta rehta h btaye sir
Kya problem thi aapke AC m
Ager outdoor pura sistem sahi hai conteckter dabane par chlta hai chod dene par band ho jata hai kya problem ho sakta hai
Ac ko dobara chlane k baad hot mode me chla jata h 4-5 baar reset krne pr cooling dene lag jata jaise hi supply jati h hot air dene lag jata please reply split ac duel inverter h
Sar voltas d.c invetor ac ha koi error nahi a raha ha 2 mint chalta ha out door band ho jata ha fer 3 mint baad on ho jata ha out door fer band ho jata ha kya problam ha sar usme
Gas puri ha cooling bhadiya karta ha 7 amp le raha ha koi hii amp nahi le raha ha
Asha test me koin koin se sawal puchhte hai plz ek full video banaye sir ji
Bro caarier ac main indoor unit chalta h Or compressure m chalta h. Kuchh time 10 minute chalta h. Indoor unit autometic off ho jata h indoor unit display light blinking hota h continue 1 minute.fir 1 minute k baad light blinking off ho jata h fir indoor chalta h.or pcb new lagaya. Gas thik h. Jaisa timer set ki tarah hota h.
Sir problem ko sol krne ke liye koi whatsapp group h kya?
Mera blue star ka 1.5 ka ac h uska compressor kuch time chalne k bad trip ho jata h or indoor se garam hawa ane lagti or compressor dhere dhere chalta rahta h kuch time tak ism kya problem ho shakti h
sir me apne ac ko 28 pe set karta hu or ac room temp ko 29 pe laake outdoor band ho jata hai
Mera bhi yahi ho rha h
plz sir btye... ac chlte chlte mode lg jata hai .. automatically jiss se cooling nhi hoti fan fan chlta hai plz sir btye kya kre
Sir meri AC panasonic ki hai aur vo kuch der chalti hai aur kuch der cooling karti hai phir band ho jati asa baar baar par karti hai mai kiya karu
Sar mera ek hi voltage 1.5 tan hai usmein ice a jata hai filter aur capillary change Kiya Hai Uske bavjud Fir se Ab Kya Karen
3minute split AC chalne ke bad start hona,Punha start challah kya Karan hai,bataye
Too good video.
Sir samsung ka ac hai uska 60 se automatic 120 hota hai candensor bhi saf kiya to bhi pressure badh ta hai Kay problem ho sakta hai
Mera mitsubishi heavy duty srk18yvs w6 split ac hai. Chalne ke 10-15 minute baad cooling band ho jati hai aur green led light 6 times blink kane lagti hai. Kya reason ho sakta hai.
## Purane models me ek case paya tha ki jab swing flapper motor jam Hoti he tab blower motor ki speed bhi Kam kardeti he uski Bina se coil thandi hokr sensor se compressor trip karwati he. Swing flapper motor kaa socket Nikal dene se compressor ok chalta he, reason wohi tha ki swing motor purani hone se jyada load le rahi thi.
Sat 1 ton ac suruvat me 5 minit thand kar rahi hae. Fir nahi.
Aur A 5 se .A 2.5 ho raha hae..
Plz .solution bataen
Sir ji mera ac 1.5ton ka hai din me ek bar cooling kane ke bad dubara cooling start nahi hoti hai par raat me bikul thik kaam karta hai kya problem hai.
Voltage problem bro
@@sarveshrajput34 Same with me
Gas problem h ac me
Voltage problem ho sakta hai ya sarvice ka bhi
Head pressure badh jata h or compressor off ho jata h
Mere O general ka 1.5 ka window ac hai 2 year phele purchase kiya tha aur ab cooling problem aari hai . 10 minute cooling krta hai uske baad nhi krta.
Phele ek service wale ko bulaya usne bola gas leak ho gyi .gas dalni padegi .
Durse service wale ko bulaya cross check krne ke liye to wo bolta hai ki jb meter se check kr rhe hai to reading 200 dikha rha hai aur stabilizer mai 220 dikha rha hai .ho skta hai stabilizer mai problem ho kyuki ye thoda heat bhi ho rha hai .
Mujhe koi btaye aesa kyu ho rha hai .
Reply plz zzz
pahle ac ki service karo or us ka condenser achchhe se saf karo thi ho jaygi agar fir bhi nahi hoti to gas kam ho sakti hai
Very nice 👍🌹
Mere Blue star 1.25T window ac ka temp. 28 se neeche nahi horaha hai...gas poor hai kahin leakage nahi hai
Bhai ac thik h outdoor khrab ho gya koe dusra outdoor lga skte h.. Plz bhai reply
Super duper sirji
Mera lg ac dual inverter hai,on karne ke baad bahut awaj karta hai aur band ho jata hai,error ch 10 ata hai,kya karen
Sir ji mera split Ac ka pankha pehle se kam chal raha hai,or cooling bhi jyada nahi deta please batayein
Our Hitachi 1.5 ton window ac 3 star after 2 or 3 hours it becomes jaam, then we stop and restart after 20 minutes, it works again. But it jaams again after 3 or 4 hours.
What is this.
Bhaiya ji Hamare ISI mein बार-बार ch41 likha hua a raha hai aur calling cut rahi hai ham Kya Karen bataiye
Cassette AC hai uska main sab kuchh ok gas bhi ok hai condenser heating bhi achcha Nikal Raha Hai per cooling nahin kar raha hai to kya problem ho sakta hai please batao bhai
## outdoor unit ka upper side Ka top laga hua naa ho, wo open ho tab bhi compressor thodi Der baad bnd hota he ese case me compressor khrab hone ke chances zyada hota he
Room ka temperature 22 hai or ac ka set kiya hai 20 1 ton ka ac hai to vo kitne ampere lega ...
AC kitne watt ka hai uspe depend hai
Jaise 3 star AC zyada watt ka aata hai compared to 5star AC
Normally 4 to 5 AMP
Mera 1 ton ka AC hai Panasonic company ka AC chalu karne ke bad thodi bar cooling hota hai aur bad mein uska jo temperature ka indicator hai usmein se Lal light blinking hoti hai aur bad mein aisi automatic band hota hai iska kya problem hai aap bata sakte hain kya dhanyvad
Mera lg inverter AC h jo ki high cool pr chalane pr bhi room temperature Kewal 32 hi rakhta h iska kya karan h machenic ko dikhaya sabhi sahi bta rhe h lekin cooling proper nhi h
Machine ke inlet outlet ki air ka temperature check Karo agar 14 ,15 degree ka difference hai to AC sahi kaam kar rahi hai .
Hitachi inverter split AC ka compressor din me bar bar (20-25 sec bad) tip kar raha hai, or kuch der bad outdoor and indoor dono bandh ho raha hai 4 time blink ke saath. lekin raat me bilkul sahi chal raha hai. Iss ka Karan kaya hai...
Sir system choking ha kise pata chale ga batiya ❤️🙏
Great
sir mere pas window ac h ac wala bhai service krke gya tha oske baad se jb bhi cooling aani start hoti h to voltage km ho jata 194 tk oske baad grm hwa aata h sir please btaye kra kre ac wala bhai bhi fon nhi otha raha vo to msg seen krke chhod de raha please please please sir
Kese theek hua aapka AC ?
Sir batatye kya Kiya jaye
## inverter AC ke outdoor unit me condenser Pura clean he magar PCB area me kachra yaa rust laga ho ya Kisi ne wiring box khula rakha ho jisse kabutar ya Kisi birds ya insects ne kachra jama Kiya ho tab bhi 2 se 5 minutes compreeser chal Kar band kardega
Good teacher
Thank you! 😃
ek help chaihiye thi mere yeha light bar bar chali jati hai kabhi aati hai kabhi chali jati hai aur air conditioner remote se on hota hai jaise ki raat ke 3 baj rahe hai light chli gyi fir mujhe remote se hi on karna padega kya yrr chahe mei soo raha hu khud Automatic on nahi ho sakti hai kya
मेरा 1.5टन का वोल्टास का स्पलिनट ए सी है जो हमेशा ही जून के महीने मे कम्प़ैशर बार बार बन्द होता है
Same problem bro same ac
Same problem
Seme ac seam problem
Sensor problem sa outdoor on nahi hora agar blower motor kharab hogi thabi bhee outdoor work nahi karaga deepbtahoo transfarmar kharab hoga tbee outdoor on nahi hoga
Hitachi window AC works fine with fan Speed medium and low but trips at fan speed High. Any solution?
Mera 1.5 ton ac h .. hardly 2 min chalta h uske baad garam hwa deta h .. uska kya reason ho skta h
Voltas window AC h 14 ampeir pe chal Raha hai cooling kam h kya kare
Hello sir
Mere window ac 1.5 ton me kabhi 5 minat kabhi 20.kabhi 30 me trip ho ja raha hai , 210 volt pe nahi chal raha hai agar 250 volt drahe hai to chal raha hai kuch help kare sir
90 and 300 aut put wala staplizar.lgao
Sir ac kabhi cooling kar rahi hai kabhi nahi kar rahi hai is topic ke upar video bana do or sir ac ki caplary or ac ki pipe kahi par bhi moisture choking ya oil choking ho to kaese findout kare ki ac me choking ki problum hai is topic par bhi video bana do plz sir - My name is Mohammad Adil
bhai ak or kami he wo ye he ki kayi war makenik jalwaji me oudur diwar par fit karti sameh dihan na dene par a c kaam nhi karta matlab ye hi ki jase diwar pe oudur lagaya to uski samne ki diwar dur honi chahiye kyunki pass hone se cumpresar war war tirip hoga
Vikas thakur
My samsung ac temperature not goes done below 25 c room temperature what will be the issue refill the gas after vaccum 2 times problem not solved
## compressor Ka pumping agar Kam hota he tab bhi thodi Der me band hojata he. For example aap khali system me compressor chalate ho agar usme Aapka pumping 300 se 400 tak aata he to ok he warna isse Kam ho or back pressure speed se down hota he tab bhi Aapka pumping low he
1.5 ton ac h 2 min outdoor fan chlega band ho jayega or fir ni chlega cooling bhi ni hoti h kya kiya jaye
After running 2 to 3 hours out door fan is stop . Cooling is stop . After some time I start again than cooling is start
What is the problem in my panosic inverter AC , please help me/guide
Sir ac 1/2ghanta coling deta hai fir bad me compressre trip hota hai or khai outdoor fan chalu rahta hai
Check compressor & fan capacitor and voltage.
16-6-23 ko technician ne aakar mera voltas 1.5 ton AC ko re install aur service kiya lekin ab cooling thik se nhi ho rahi hai, kya kru
Bhaiya mera new Ac h lyod ka Ac kam nahi kar rha h jese hi cooling start hoti h band ho jata ha apne Aap
Sir out for bar bar me bnd ho rha h eska kya solution h
Aadha ghnta Ac sahi chlta h fer outdoor band ho jata h coil sensor badal dia ac service bhi krw di capacitor bhi badal diye fer bhi same issue h kya kare sir
Windo Panasonic ac aoto chalu bandh kyu nahi hota hea
Ac cull karti hai lakin room ka temperature nahi bana rahi hai bahi kya problem ho sakti hai godraj window ac hai
## indoor unit Ka blower motor kharab ho ya jaam ho yaa shaft uski rouse ho chuki ho yaa blower se zyada motor gumti ho tabhi ye dikkat Hoti he coile thandi hokar sensor se compressor trip karwata he
Sir Hitachi 1.5 ton inverter hai par temperature pura hone pe cat nahi hota
Kha se ho bhai aap
## indoor unit me nut jaha se tight hota he Jo hissa spring se lipti pipe yaa fir kahi or Kisi piping se pinch ya pipe dab chuki ho to aap meter guage se pata krne par kanta up and down hota rahega stand by Nahi rahega tab bhi compressor thodi Der me band hojata he
Asslam alikumm sir Mera Kenwood AC h 10.mnt chlta h phir just hwa deny lgta coling khtm ho jati phir 10mnt bad coming start ho jati bht preshan main 1,5 daidh tun AC h Mera 23 hzar bil Aya h es bar plz help me
Jo Msla h bta dein
Mera bindow a/c hai, ye ese chalta hai, lekin dopahar ko sound aata hai orculing band ho jati hai, night main chalta hai condensor bhi change kiya tha
Sir hamara ac 2 ton ka h to Jab lae the tab to first day ko bahuthi Acha cooling ki this but uske second day se hi cooling kam hogai or jisse liyatha vo man hi nahi raha hai ki ac me koi khrabi h .
Bhai,unit start hone time compressor normal hoga,kuch time chalne ke bad, discharge pressure perfect hoga,Lekin suction reed problem se wo proper refrigerant suck karnehi payega,phir wo proper refrigerant discharge karega nehin, naturally cooling stop ho jayega,ampre below hote jayega . Reply jarur Dena bhai.
Thanks sir
Your welcome
Mera ac 1.5 ton hai uska out dore thodider cooling karta hai aur badme turant band hota hai our uska picheka fan aur Indore ka fan bhi slow chalta hai please madat kijiye
## outdoor unit ka fan jiska wiring kisine Ulta Kiya ho for example motor se fan garam hawa bahar fekne ki bajay andar fek raha ho tab bhi compressor thodi Der heat hokar trip karta he
Mera chachi ka split AC hai thodi der cooling Karta hai FIR chhod jata hai kya Karan hai
## inverter AC me mostly Panasonic me 10 minutes chalne ke baad " df" defrost me system deta he jisme pcb regarding issue rehta he agar dusri pcb replacement yaa repair karwani padti he
K8
11tr ki r407 gass me h or suction pipe pr ice aa rha h
Ac band hone k baad kitne dar tk room main cooling rahti h
Assalam walekum sar mera naam Farhan Ali hai sar main Hyderabad se baat kar raha hun sar Mera aisi abhi new pack dabba hai Maine 10 din pahle lagwaya hai aur mera chalte chalte outer off ho jata hai iska kya reason hai aap mujhe aap reply please de dijiyega aur AC 1.5 ton ka hai aur cooling bilkul acchi nahin kar raha higher ka hai sar thank u so Mach
Need to call service centre
trip ka kya matlab hai sir
Defect ke karan bandh hona
## remote me agar aap temperature celcius ki jagah par ferenheat rakhoge tab bhi compressor thodi Der me temperature aane se band hojata he
## inverter AC me outdoor unit ke sensor Kisi Tarah se kharab ho ya kisine kutar diye ho tab bhi compressor humming leke bnd hota yaa start Nahi ho pata he error dekar.
Sir ac adha ghanta chalta hai theek phir garam hawa dene lagta hai fir usko adha ghanta band karke chalate hai toh fir theek chalta hai kya problem ho sakti plz reply
Same problem. Window AC hai kya?
Kya problem h aapke AC m
## outdoor unite me compressor 5-10 minutes chalne par suction line par return proper aata hoga magar after 5-10 minutes compreeser ke piston ya michenism me kharabi ki wajah se awaaj karke band hota he or sirf fan on rehta he or suction line garam hojati he
Same condition...plz reasion btao
Same problem