Generator Power Factor and Amps Calculation in Urdu / Hindi | Asad Electrical
ฝัง
- เผยแพร่เมื่อ 19 มิ.ย. 2021
- Power Factor Details
• Power Factor Formula (...
• Power Factor in Urdu H...
• Generator Nameplate In...
Star Delta in Generator
• Star Delta Calculation...
• 3 Phase Alternator URD...
Great explanation.
Knowledge is power
Very best Mashaallah
field suppression generator me kaise hota us pr video banaiye sir ji
Diffrence b/w Kva and kw .
Genrator are powered on kva.
Nice video
Very nice
Why do you always calculate with KvA in formulas and not KW ?
Please make one video on HP motors , that how to calculate generator size if we have motors (HP) ?
th-cam.com/video/12biyn2_Owk/w-d-xo.html
th-cam.com/video/DTnkB4LXM44/w-d-xo.html
Thanks Sir
👌👌good
Very good sir 🎉🎉🎉🎉
Ak question hai ape nae 180 amp calculate kiya. It's mean k hum 3 no phases pay total 180 amp load dal saktay hai???
Sir Chock Hatake AVR Konsa Lagai
Aoa.. Asad bhai. I HAVE one request to u.. kindly make a video on my special request. when two to three gensets are synchronized and suddenly the power factor of one of them Genset's reached its maximum lead position similarly the VARS current becomes very very low. While the other gensets behave oppositely... power factor on maximum lag side and VARS current very high. kindly answer all tha possible causes... we are facing same problem on our one geneset since long time..
You need to adjust p.f from Avr excitation for all generators
Good job sir
👌👌👌👌
Salam 5kw two inverter different company ka hy is ko kasy parallel Kerry jes ten kW banjy.wasalam
W.salam kar saktay hen
❤
Sir 240kva generators kitne ampere ka hoga
345
Apne generator ka pf daal k tu amps nikal dye but for example moter ho uska pf 0.9 ho tu is se generatr k ampere pe kia frq prega??
Ap same formula apply krain pf o.9 daal k jo bhi amps ayngay wohi generator k amps hongay kyu k PF load pe depend karta he
Ok bro thanks bro kia ap tower cranes etc ka kam jante hai?
Asad bhai generator ka P.f kis tarah check kr sakty hain mtlb hamin ye daikhna ho ky Gen 0.8 Pf day bhi raha hy ky nhi ye kasy check kryn gy .? plz tel me
Generator ka power factor load pe depend krta he uska apna nhi hota. Generator normally 0.8 pf k liye design hota he
how to calculate torque load on caterpillar 3412 750kva 50h generator
Sir Sari videos dekhi but ye nhe smjh Ska ke ktny load pr ktna power factor set kry gy jo ideal ho ga ya power factor kis cheez ko dekh kr set kry
Power factor load k hisab se hota he khud se set nhi kiya jasakta agr generator single ho. Agar load sharing par ho to usko maintain karna hota he saray generators ka aik jesa hona chahye.
@@AsadElectrical hmary pas turbine hy jo wapda ke sath sync hy us pr kaisy manage kry gy
@@UsmanAli-xp6jc turbine generator ka p.f wapda k pf se match krna parega
Why voltage is 400V and not 220V??
220 is for phase to neutral and 400 is for phase to phase
DG showing fault - 1472 ....what is the issue ? What to check ? How it can be rectified ? Help it out plz
Generator make / model ?
@@AsadElectrical make - Cummins,...model - CS250D5P
@@SahidKhan-bq3vb Code 1472 - High AC Current (Shutdown)Logic:The generator output current has exceeded at least 150% of rated current.Possible Causes:1. Generator set overload Diagnosis and Repair:1. Generator set overload. a. Reduce the generator set load by powering off to unnecessary household appliances (examples: washer, dryer, air conditioning, etc.)
@@AsadElectrical same thing I have found in .....
Actually I have already put the mccb in off position...so now what to do ?
@@SahidKhan-bq3vb check load and CTs or connections
Generator unit = KVA
why calculate use KW formula ??????
th-cam.com/video/DTnkB4LXM44/w-d-xo.html
Thanks sir