Generator PF 0.8 ? What will happen if the power factor of the generator is less or more than 0.8?
ฝัง
- เผยแพร่เมื่อ 22 ต.ค. 2024
- The Careers360 offer highly specialized knowledge and training for those seeking to learn from peers operating at the highest levels of their chosen disciplines. They can help you access deep insights and uncover new opportunities for your career. We provide 100%job placement assistance, guaranteed
We are committed to create a strong and Careers360 is one and only high-tech Engineering Trainings center in Pakistan, we provide advanced & expert level Engineering Trainings as per Pakistan and International market need.
With 100& placement assistance in local and international market.
Explore the pages below to learn about practical courses for professional development. You'll find the resources and professional insights you need to create lasting success in a competitive global marketplace.
VISION
WE ENVISION IN DELIVERING SUSTAINABLE HUMAN CAPITAL FOR THE FUTURE
MISSION
Our mission is to design and deliver high impact development programs and a wide range of consultancy services that produce outstanding human performance in your organizations and individual’s.
GUIDING PHILOSOPHY
continuous improvement in human capital performance with your organization and individual’s.
For More Info, JOIN US
Call +92-300-4336502
WhatsApp +92 331 4081886
Email
info@careers360.com.pk
www.careers360.com.pk
TH-cam
/ @careers360-pk
LinkedIn
lnkd.in/dhmJVvf
Facebook link
lnkd.in/d2WPRuc
Tweeter
@CAREERS3602
Instagram
Careers.360
#career #mechanicalengineering #descon #lahore #learninganddevelopment #training #projectmanagement #projectleadership #projectmanagementprofessional #youngprofessionals #youthempowerment #youthdevelopment #lahore #emergingleaders #strategy #estimation #costing #knowledgesharing #knowledgeispower #SAP #hiring #manufacturing #mechanical #industrial #development #electrical #careers #engineer #job #hiringnow #electricalengineering #powerengineering #careersupport #skills
Will the PF effect the fuel consumption?
Power factor inversely proportional with current, so if power factor goose down, amps will be increased, then obviously fuel consumption will increase (even KW will remains same )
Mera dg 125 kva ka hai and usme power factor 0.95 it is acceptable or not?
It's not an issue, but you DG set will down its size 15% , means it's not 125kva it's will be 107kva.
@@careers360-PK how i maintain at 0.8?
Kw=kva*0.95
Kw= 125 * 0.95 = 118.75 kw.
Means generator capacity has to provide load of 118.75 kw.
Please reply
@@mjk568 no , watch video again
I have 25 kv generators on gas
Power factor is 1.1 i guess
How can i make it to 0.7-0.8?
Pls help sir
It would be -0.9 or leading 0.9 , means it's negative power factor , which is harmful for alternator .
Most of your load is capacitive , capacitive load is causing of negative power factor, only option is reduce your load maximum 65% of the capacity
@@careers360-PK sir what do you recommend? Cause load shedding here is 12 hrs almost, and gas bills rise alot
So how do i decrease it?
8