Another Way if Between 1 and 16. Enter Programming, Go To Location 101, Scroll Through the Digit String, Enter 00 for Zone You Want Eleminated. If a Wireless Zone, Enter Programming, Go to Location 804, then 82 For Zones 1-8, 83 for 9-16 And So on. When You Press 82, 1 through 8 mabe be indicated if Active, Press 7 So #7 turns Off. Is Now Inactive. ## To Exit Programming.
@@JasonTech Hey Jason. Thanks for the quick response. I did try that, opening the front door next to the device. It displays "Front Door," but not a number. I'm trying to find the number. Then I realized the zones are displayed in order. So I can get the numbers now by counting as I scroll through the zones.
I have zone 1 as the entry door to our church and in the entry area facing the door a zone 2 PIR. I programmed section 1 with an entry delay of 30 seconds, the middle delay 90s and the exit delay 45s. Here is the challenge. When arming and disarming with the remote control there is no alarm when entering. However if I don’t use the remote, both zone 1 and zone 2 sets off the alarm when entering as if there is no delay programmed. Any assistance will be appreciated as the armed response keep calling when people with access codes enter and the alarm is triggered on entrance. Thanks
Another Way if Between 1 and 16.
Enter Programming, Go To Location 101, Scroll Through the Digit String, Enter 00 for Zone You Want Eleminated.
If a Wireless Zone, Enter Programming, Go to Location 804, then 82 For Zones 1-8, 83 for 9-16 And So on. When You Press 82, 1 through 8 mabe be indicated if Active, Press 7 So #7 turns Off. Is Now Inactive.
## To Exit Programming.
Thanks, good video... Do I remove the wire that's in the com slot that has a resister on it when I put in the jumper?
Q. Do all your zones have resister on them?
@@JasonTech Yep...
every com slot has a resister, but not every zone has a com slot...
Put the other end of the resister in the zone.
@@JasonTech So, I should snip the resister wire that is attached to the com wire and put the sniped end into the zone slot? Correct?
Thanks, very helpful. Worked great.
Thank you!
If I don’t know what zones are connected to the doors and windows, how can I find the zone number corresponding to each location?
Have someone open a zone (door/window) and a 2nd person to check the keypad.
2nd way is to tone out the wires.
@@JasonTech Hey Jason. Thanks for the quick response. I did try that, opening the front door next to the device. It displays "Front Door," but not a number. I'm trying to find the number. Then I realized the zones are displayed in order. So I can get the numbers now by counting as I scroll through the zones.
What keypad model do you have?
@@JasonTech 9057. I figured out the zone numbers by going to the bypass menu and scrolling through the locations. So I'm all set! Thanks.
What resistor do I need to buy?
The zone still shows as open when I use a wire as a jumper
It should be a 512
Sound like you have EOL resistors.
@@JasonTechYou rock Jason. Works like a charm!
5.6K, 5600 Ohms,
Green/Blue/Red, Gold for 5%
If Homeowner and Putting Resistors in Panel, May as Well Program Closed Loops, Not EOL.
Is the installer code the same as the master code?
No,
Hi bro we have two zones error change pir but arming pad in issue same pls give suggestion
You changed the motion?
Do the motions light up?
Do you have EOL?
I have zone 1 as the entry door to our church and in the entry area facing the door a zone 2 PIR. I programmed section 1 with an entry delay of 30 seconds, the middle delay 90s and the exit delay 45s. Here is the challenge. When arming and disarming with the remote control there is no alarm when entering. However if I don’t use the remote, both zone 1 and zone 2 sets off the alarm when entering as if there is no delay programmed. Any assistance will be appreciated as the armed response keep calling when people with access codes enter and the alarm is triggered on entrance. Thanks
How to you rearm a permanently bypassed zone?
You can't, you will have to bypass then arm each time. The best thing to do is to remove the zone if you don't need it.