  • @Aol-h7d
    @Aol-h7d หลายเดือนก่อน

    Great video 👍

  • @willyum1208
    @willyum1208 ปีที่แล้ว

    @ 3:39 why didn't you fill the gap between the flange and drywall with Kerdi Seal?

    • @schlutersystems1
      @schlutersystems1  ปีที่แล้ว +1

      Hi there ! It wouldn't be necessary to fill the gap with KERDI-FIX here. The KERDI-BAND connection will be solid between the KERDI-FIX on the tub flange and the thin set mortar on the wall. So, there is no need for movement accommodation at that spot. Hope that helps!

  • @stacktier8257
    @stacktier8257 3 ปีที่แล้ว +1

    Thank you for the detailed info, especially both approach of drywall installation, installed flush with the lip of the tub deck and over the flange (when the wall is built out).
    It hard to find professional organizations (or DIY channels) that offer details on building out a wall, especially when it comes to finishing the likely j-trim transitions.

  • @blackbowtie9285
    @blackbowtie9285 ปีที่แล้ว

    What do you do over the tapered drywall joints? Would it be a good idea to apply thinset the day before to make that drywall joint smooth? Just wondering if the kerdi membrane would follow that taper

    • @schlutersystems1
      @schlutersystems1  ปีที่แล้ว

      Hi there! Would you be able to reach out to our Customer Service team to discuss your project in a bit more detail? They’ll be able to request more information on the specifics of your project to give you the most accurate answer possible. You can reach them at 800-472-4588 (US) or 800-667-8746 (CA). Thanks

  • @TaurenJam
    @TaurenJam ปีที่แล้ว

    Question
    Why use kerdi band on the bottom on the perimeter of the tub and then overlap it with the wall sheet? Why not just run the wall sheet all the way down?

    • @schlutersystems1
      @schlutersystems1  ปีที่แล้ว

      Hi there ! The KERDI-BAND is required in this application as having the 2'' overlap won't be achieve with only the KERDI used on the wall. Having that extra band ensures it is water tight. Hope that helps!

  • @garrettp.5018
    @garrettp.5018 10 หลายเดือนก่อน

    When applying the kerdi fix in the tub flange gap, would it be a problem applying all set OVER the kerdi fix? I went overthe kerdi fix with all set then kerdi banded it.

    • @schlutersystems1
      @schlutersystems1  10 หลายเดือนก่อน +1

      Hello! As long as the KERDI-FIX was able to make a direct bond to the tub connection, that shouldn't affect anything. Hope that helps!

    • @garrettp.5018
      @garrettp.5018 10 หลายเดือนก่อน

      @@schlutersystems1 Correct, the Kerdi-FIX was able to close the entire gap including contact with the tub.

  • @psbenipal7695
    @psbenipal7695 3 หลายเดือนก่อน

    What kind of glue we can use to paste the sheet on wall ? Please share the glue name if possible

    • @schlutersystems1
      @schlutersystems1  3 หลายเดือนก่อน

      Hi there! You can use our ALL-SET thin set to install the KERDI membrane over drywall, or any other unmodified thin set. Hope that helps!

  • @sceachain
    @sceachain 2 ปีที่แล้ว

    Q. Do you let the Kerdi-Fix fully cure before applying the Kerdi Band and Thinset ? Or do you apply the Kerdi-Band over the 2 materials while they are both "Wet" ?

    • @schlutersystems1
      @schlutersystems1  2 ปีที่แล้ว

      Hi there. It is not necessary to allow the KERDI-FIX to fully cure before applying the thin-set mortar and KERDI-BAND as the KERDI-BAND will need to adhere to both the thin-set mortar and KERDI-FIX to ensure a vapor tight application. Hope this helps!

  • @othername1000
    @othername1000 3 ปีที่แล้ว +1

    Yep turns out my mixing valve cover is smaller than the hole. That's going to be fun to fix. Thanks Kerdi.

    • @schlutersystems1
      @schlutersystems1  3 ปีที่แล้ว +1

      Hi there, you can use KERDI-FIX as an alternative to the seals. This method is helpful when the pipe or mixing valve is a different size. Please feel free to give our Product Support team a call if you'd like us to discuss your project in a bit more detail, and from there they can offer any advice as needed. 800-472-4588 (US) or 800-667-8746 (Canada). Hope this helps for now.

  • @thomasnorthcastle4130
    @thomasnorthcastle4130 3 ปีที่แล้ว +1

    I wish that you had larger mixing valve covers.

  • @chrislombard884
    @chrislombard884 ปีที่แล้ว

    Can this be installed over backer board?

    • @schlutersystems1
      @schlutersystems1  ปีที่แล้ว

      Hi there! Yes, Cementitious backer unit - ANSI A118.9 or ASTM C1325, Fiber-cement backerboard - ASTM C1288, Fiber-reinforced water-resistant gypsum backerboard - ASTM C1278, Coated glass mat water-resistant gypsum backerboard - ASTM C1178 are all approved solid backing materials to install the KERDI membrane over. For more details, you can have a look at the Shower System Installation Handbook here: sccpublic.s3-external-1.amazonaws.com/sys-master/images/h26/h81/9474607349790/Shower%20System%20Installation%20Handbook.pdf

  • @willyum1208
    @willyum1208 ปีที่แล้ว

    Surely that Dialex perimeter joint isnt water proof? Water will easily seep under it, is it Kerdi sealed to the tub?

    • @schlutersystems1
      @schlutersystems1  ปีที่แล้ว +1

      Hi there! The DILEX-BWA is not waterproof but behind the profile, there is KERDI or KERDI-BAND which is adhered to the tub surround with KERDI-FIX. The assembly is then sealed and waterproof. Hope that helps!

  • @texasmike7994
    @texasmike7994 2 ปีที่แล้ว

    This can be applied over Sheetrock? Thanks

    • @schlutersystems1
      @schlutersystems1  2 ปีที่แล้ว +1

      Yes, gypsum wallboard is an approved solid backing material for Schluter®-KERDI.

    • @texasmike7994
      @texasmike7994 2 ปีที่แล้ว

      @@schlutersystems1 awesome, thanks

    • @schlutersystems1
      @schlutersystems1  2 ปีที่แล้ว

      You're welcome!

  • @McFlysGarage
    @McFlysGarage 3 ปีที่แล้ว

    In the video the tile seems to go from the tub flange all the way to the ceiling above the tub. If that is the case is the tile installed as per normal above the schluter system products?

    • @schlutersystems1
      @schlutersystems1  3 ปีที่แล้ว +1

      Hi there, yes, that is correct. The KERDI needs to be installed to the height of the shower head, at minimum. The tile is installed per normal to the solid backing above the KERDI.

  • @basschica
    @basschica 2 ปีที่แล้ว

    Do you offer referrals to contractors that know and use your products? I only see sales locators on the website.

    • @schlutersystems1
      @schlutersystems1  2 ปีที่แล้ว

      Hi there, Sorry, but we don't have a contractor referral program. The dealers found on our website do deal with contractors daily, so they would actually be in a good position to refer you. Hope this helps!

    • @skylar1727
      @skylar1727 2 ปีที่แล้ว

      It looks pretty straightforward from watching the video. I would think any competent contractor could follow this! :)

  • @Damorann
    @Damorann 3 ปีที่แล้ว

    Maybe I don't fully understand something, but when installing the DITRA with the KERDI band, how come removing the painter's tape not leave a small gap between the bath and the KERDI-Fix/membrane ? Is there a risk that water would penetrate there ?

    • @schlutersystems1
      @schlutersystems1  3 ปีที่แล้ว

      Hi there!
      The painters tape is adhered to level with the top of the DITRA so there will be about 1/8” of KERDI-FIX contacting the tub under the KERDI-BAND. The painters tape is removed while the KERDI-FIX is still pliable, so no gaps would be created. If preferred, you could always adhere your tape a little higher (but not higher than your tile) and wrap the KERDI-BAND onto the side of the tub a little bit with the KERDI-FIX.
      Hope this helps!

    • @Damorann
      @Damorann 3 ปีที่แล้ว

      @@schlutersystems1 Thank you for the answer !

  • @phantomcreamer
    @phantomcreamer 3 ปีที่แล้ว

    What if the tub does not have a flange

    • @schlutersystems1
      @schlutersystems1  3 ปีที่แล้ว

      Hi there, we do cover this in the video-- check out timestamp 3:55. Hope this helps!

  • @grvital3645
    @grvital3645 3 ปีที่แล้ว

    Вподобайка 👍👍

  • @cynthiamalla5791
    @cynthiamalla5791 2 ปีที่แล้ว

    Grid out

  • @trevordsouza9174
    @trevordsouza9174 ปีที่แล้ว

    Schluter products are overrated and overpriced. Also followed mixture procedure of their All set cement and found out that the wall membrane did not adhere to the mold resistant drywall consistently. I couldn't take a chance expecting this membrane to support wall tiles. Schluter warranty is only on paper. They squirm out of honoring their warranty by finding excuses. All contractors with years of experience I spoke to stay away from Schluter products.

    • @schlutersystems1
      @schlutersystems1  ปีที่แล้ว

      Hi there! Sorry to hear you are having trouble with membrane and thin set. We'd like to know a bit more about what happened and would like to connect you with your rep. Please send us a DM with your name, zip code, and phone number and we'll put you in touch with him/her.