High Suction Pressure Resolved

แชร์
ฝัง
  • เผยแพร่เมื่อ 4 ก.ค. 2020
  • This video is about High Suction Pressure Resolved. We replace the piston, replace a filter dryer, diagnose and replace a reversing valve.
    Please visit my Patreon page for additional content and to support my effort to help others be successful in the HVAC field. / abilityman

ความคิดเห็น • 39

  • @chrismancol6792
    @chrismancol6792 3 ปีที่แล้ว +3

    John was the first teacher I had getting into HVAC, you guys subscribe, he's a great teacher and great guy, we can all learn from him.

  • @chadoxdcfan
    @chadoxdcfan 4 ปีที่แล้ว +2

    I just had this problem at house and changed the TXV. And the low stayed at 190 very close to what you got. Glad to see this video. Thanks bro I just subscribed 👍

    • @techfive7202
      @techfive7202 4 ปีที่แล้ว +1

      Fuck I just diagnosed the same issue as a bad txv.

    • @jaybird9391
      @jaybird9391 3 ปีที่แล้ว +1

      Low pressure at 190?

  • @baylifehvac991
    @baylifehvac991 3 ปีที่แล้ว +3

    Such pressure only went down 30psi , still pretty high pressure in my book. Good job

  • @angelsair.2650
    @angelsair.2650 4 ปีที่แล้ว +1

    Great video thanks

  • @donnierobertson3088
    @donnierobertson3088 3 ปีที่แล้ว +1

    Nice job and video

  • @geraldrascon1041
    @geraldrascon1041 2 ปีที่แล้ว +1

    You great thank you this help me

  • @howardharaway2259
    @howardharaway2259 2 ปีที่แล้ว +1

    I am working on a 2 ton York 410A scroll. Someone else in my co. Diagnosed a bad compressor. I just replaced compressor Symptoms are still present. Close to normal head pressure about 318 and suction 229. We are coming back tomorrow with a thermal expansion valvexpansion valve but I think it's the Piston in there that's causing the problem

    • @AbilityJohn
      @AbilityJohn  2 ปีที่แล้ว

      You either have a txv or a piston. Not both. If it’s a heat pump look at the reversing valve. Your super heat and sun cooling will tell a better story. The only way I can think of an expansion valve would cause this is if the bulb isn’t secure to the suction pipe.

    • @steven4776
      @steven4776 27 วันที่ผ่านมา

      Someone probably forgot to install the piston

  • @2bnax
    @2bnax 2 หลายเดือนก่อน +1

    I CAN'T FIND ANYONE TEACHING ABOUT LOOKING AT DISCHARGE PRESSURES WHEN PERFORMING SUPERHEAT CHARGINGC CAN YOU EXPLAIN WHAT IS THE EXPECTED READING??? THANKS!!

    • @AbilityJohn
      @AbilityJohn  2 หลายเดือนก่อน

      On old 10 seer units you would shoot for 30 saturation over ambient. With new higher efficient systems it’s more like 15 to 20.

    • @2bnax
      @2bnax 2 หลายเดือนก่อน

      @@AbilityJohn GOD BLESS YOU!! STRAIGHT TO THE POINT, WITHOUT A MYRIAD NON-ANSWERS! THANKS AGAIN!

  • @chrismancol6792
    @chrismancol6792 3 ปีที่แล้ว +1

    John how are you? Glad to see you're still don't hvac, I hope all is well with you and your family

    • @AbilityJohn
      @AbilityJohn  3 ปีที่แล้ว +1

      Things are good. Nice to hear from you.

    • @chrismancol6792
      @chrismancol6792 3 ปีที่แล้ว

      That's good. Yeah same here.

  • @MikeInocencio-sl7ih
    @MikeInocencio-sl7ih หลายเดือนก่อน

    Can you spray that heat stuff ins8de the valve too.? To keep it cool?

  • @user-friendly-pm
    @user-friendly-pm ปีที่แล้ว +1

    Overcharged? I have same issue but the low pressure is so high it blew my manifold gaskets

  • @rrodgers3285
    @rrodgers3285 2 ปีที่แล้ว +1

    Darn where u located love to work with someone like u this is the real hvac university

  • @xraybravo7180
    @xraybravo7180 3 ปีที่แล้ว +1

    What kind of torch js that I'm curious and what's good about it ?

    • @AbilityJohn
      @AbilityJohn  3 ปีที่แล้ว

      It’s a Turbo Torch. You don’t need oxygen, just acetylene.

    • @xraybravo7180
      @xraybravo7180 3 ปีที่แล้ว

      @@AbilityJohn where can I get nitrogen cone tip for open lines to flow nitro?

    • @xraybravo7180
      @xraybravo7180 3 ปีที่แล้ว

      @@AbilityJohn with that said let me ask you one more thing what is your normal saturated condensing tempteture should be during low ambient ?

    • @AbilityJohn
      @AbilityJohn  3 ปีที่แล้ว

      An AC supply house carries these

    • @AbilityJohn
      @AbilityJohn  3 ปีที่แล้ว

      I can’t answer that. Too many variables.

  • @jaybird9391
    @jaybird9391 3 ปีที่แล้ว +2

    A lot of times this indicates a bad valve in the compressor?

    • @AbilityJohn
      @AbilityJohn  3 ปีที่แล้ว

      This was a scroll compressor so no. And if it was a recip with a bad valve the pressure differential would be
      Less.

  • @timbunner8855
    @timbunner8855 2 ปีที่แล้ว

    If you would have taken temperature readings on the reversing valve.

  • @lemunman
    @lemunman 3 ปีที่แล้ว +1

    I'm new to the page . But maybe you can help me 7000.00 .
    I had a repairman come look at why all of a sudden my heat pump is short cycling . They put on a meter similar to yours . But the psi was over 500 on both high and low and the temp was over 200 . I'm not sure if I'm being taken advantage of . The house is 8 years old and the heat suddenly stopped . They wanna replace everything including the air handler but they aren't sure of the problem . "Maybe a clog" . If you could help with some advice I'd appreciate it . Thank you

    • @AbilityJohn
      @AbilityJohn  3 ปีที่แล้ว

      Sounds like they hooked up the gauges wrong.
      Are they checking it in heat and getting 500 psi?
      Is the system R410a?
      This is an easy problem to pin point. I would Call another company and ask for a free second opinion.

  • @timbunner8855
    @timbunner8855 2 ปีที่แล้ว +1

    Study the basic Refrigeration cycle and these problems won't throw you a curve.

  • @Jason-wc3fh
    @Jason-wc3fh 11 หลายเดือนก่อน +1

    Don't do what this guy did with pushing in the contactor with bare fingers. Always use an insulated screwdriver. A lot of people have gotten a good shock this way from carbon buildup on the contactor. Many ways to get electrocuted by having a hand so close to live power. Electricity is no joke.

    • @AbilityJohn
      @AbilityJohn  11 หลายเดือนก่อน

      You aren’t wrong but your giving off keyboard warrior vibes here. Keep it cool man.

  • @timbunner8855
    @timbunner8855 2 ปีที่แล้ว

    If didn't have a piston. How did it work all this time this is not a new system.

    • @AbilityJohn
      @AbilityJohn  2 ปีที่แล้ว

      I’ve seen it. The system will still meter through cap tubes
      However if you watch the whole video it turned out to be the reversing valve. In this case.

  • @Independentdebtrelief
    @Independentdebtrelief ปีที่แล้ว

    The music could definitely be removed not everyone likes EDM