How to wire a solar combiner box or pass through box

แชร์
ฝัง
  • เผยแพร่เมื่อ 6 ก.พ. 2022
  • Learn how to wire a pass through box or a combiner box for your solar electric system.
    ⏱️Timestamps:
    0:06 Intro
    0:42 Reviewing pass-through and combiner boxes
    2:35 Reviewing over current protection
    3:13 Importance of electrical enclosures
    4:14 Reviewing PV wires and safety
    5:22 Cutting and stripping PV wire
    5:38 Selecting an electrical enclosure
    7:21 Installing strain reliefs and wiring
    7:56 Fuse sizing and connections
    9:08 Wire selection and transitions
    10:16 Wiring the output through conduit
    12:19 Equipment grounding
    13:30 Other videos and resources
    🗎 Publication:
    Working on Solar Wiring and Fusing (EB-2023-0676)
    go.umd.edu/EB-2023-0676
    For more information, visit: go.umd.edu/FarmSolar

ความคิดเห็น • 14

  • @SetTheCurve
    @SetTheCurve 7 หลายเดือนก่อน +4

    This video really impressed me. Densely packed with practical information in a good time order and delivered in a clear way. Earned my subscription

  • @Fester_
    @Fester_ 3 หลายเดือนก่อน +1

    Very groovy, thanks.

  • @gajimafeet
    @gajimafeet ปีที่แล้ว +1

    Gr8 explanations thank u so much

  • @abauti9763
    @abauti9763 ปีที่แล้ว

    Good instructional video! I noticed in other prebuilt combiner boxes that a surge protection is provided. When would you recommend to include an SPD in the combiner box?

  • @jussikankinen9409
    @jussikankinen9409 หลายเดือนก่อน

    Does 230v fuse work 12v system

  • @LiveSounds11
    @LiveSounds11 ปีที่แล้ว +1

    Would 4 strings going straight to the inverter need fuse protection in a pass thru box? Thanks keep rockin

    • @ridemfast7625
      @ridemfast7625 11 หลายเดือนก่อน

      Can you explain to me what your pass through box is? Does the ground wire from the mounting rail go into the box and directly to the inverter? Did you use PVC or metal box? PVC conduit or EMT? If a metal box, did you attach it to the rail, run the rail ground wire into the box, ground it to the metal box, and run another ground wire from the box to the inverter?

    • @ilyashick3178
      @ilyashick3178 11 หลายเดือนก่อน +1

      @@ridemfast7625 elecrical code is required to wire ground the equipment no matter metal or plastic boxes or inventer.
      In case of DIY local authority can tell what it is proper ground wire to get permission.

  • @SUNofNY
    @SUNofNY 6 หลายเดือนก่อน

    Some other videos say that wire nuts should not be used with PV wires... any thoughts on why they say this?

  • @ratm183
    @ratm183 6 หลายเดือนก่อน

    Does anyone know where to find the 2 hole liquid tight connector? I can find a 3 hole, 4 hole and the romex one, but none that have just 2 holes.

  • @user-dr2pg8fk2i
    @user-dr2pg8fk2i ปีที่แล้ว +2

    In understanding this was for display purposes, using bus bars like that is sketchy at best. There are much better devices for junctions.

    • @TackleThat
      @TackleThat 7 หลายเดือนก่อน +1

      This! It seems like all 3 conductors are touching in the end.. man seems dangerous!

  • @paulterry468
    @paulterry468 ปีที่แล้ว

    There is some ambiguity on the DC side fusing and/or disconnect sizing in your videos that do not tie the two together very well. Question: If you have a non-fused disconnect in a combiner box, my understanding is that you size the fuses Isc*1.25 = Imax *1.25 for continuous current = Isc * 1.56 for the individual string fusing. The main disconnect then can be sized to match the Isc*1.25*1.25*# strings OR if the disconnect is 100% rated, it only needs to be sized Isc*1.25*# of strings. This could save $$$ in some cases. Is this the way NEC intended the sizing in a combined string fusing/combiner box? It seems to be the case with the caveat that the upstream fusing and wiring (i.e, path from combiner box to inverter) still needs to be sized the extra 1.25 even if using a 100% rated non-fused disconnect in the combine box

  • @samfish6938
    @samfish6938 2 หลายเดือนก่อน

    wire nuts will burn at 100 amps