Connecting the Solar Array to a Hoffman PV Combiner Box, Off-Grid!

แชร์
ฝัง
  • เผยแพร่เมื่อ 6 มิ.ย. 2024
  • Today I finally got around t replacing the dangerous "temporary" wiring from my ground-mount solar array with a proper combiner box, conduit, fittings, etc.
    WARNING: Lithium batteries are dangerous and can result in fire! This video is NOT intended to be instructional or a "how-to" lesson. I am not a professional. Do not attempt anything you see here without first contacting a certified and/or licensed professional.
    Featured Products: (affiliate links)
    Hoffman Combiner Box... ebay.to/3jovRHK (Good Luck...)
    MC4 Crimp Tool... watts247.com/product/mc4-sola...
    MC4 Connectors... amzn.to/34IBKLS
    12AWG PV Cable... watts247.com/product/solar-ca...
    500ft THHN #6 Red... ebay.to/3lt1Ubj
    Strain-Relief Bushings... www.mouser.com/ProductDetail/...
    Recommended Stores: (Using these links helps support this channel)
    Current Connected... store.currentconnected.com/?r...
    Signature Solar... signaturesolar.com/?ref=lithi... ($50 Discount Code "LITHIUMSOLAR50")
    Best LFP Source... www.18650batterystore.com/?rf...
    SanTan Solar... www.santansolar.com/?ref=lsolar
    Battery Hookup... batteryhookup.com/discount/BA...
    Batrium BMS... www.batrium.com/
    Contact Info:
    My business email is lithiumsolardiy@gmail.com. You may contact me for sponsorships, product reviews, business-related questions, or any similar reason. I am not available for personal project questions or consultation. I will not respond to these emails.
    NEW Twitter Page... / lithiumsolaryt
    Disclaimers and Statements:
    ► I receive a small commission on purchases made using my affiliated links shared the video description and comments section. The views and opinions expressed here are my own, unbiased, and not influenced by this commission in any way.
    ► My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 210

  • @pjhalchemy
    @pjhalchemy 3 ปีที่แล้ว +25

    Hoffman boxes are top notch, used them exclusively in great quantity (Nema 4, 4X from 4x4 boxes to 6' DD cabinets) for a long time and their back panels are excellent. A Greenly knock out punch set would be a nice addition to your tool kit! Nice Score on the boxes! Really nice and proper job with proper feed thru's on the wiring and routing with good tips and tricks. Well done and thanks for sharing this with the community!

    • @peterg.8245
      @peterg.8245 3 ปีที่แล้ว +1

      My over engineered self lusts for 4X and a much larger box for hand access!
      ABB boxes are thicker but the ones we used had removable knockout plates with cork gaskets.

  • @stevemyers2092
    @stevemyers2092 3 ปีที่แล้ว +16

    30 years in telecom - USA and Canada - We use Hoffman boxes almost exclusively. Now you know why.

    • @chinoodin4735
      @chinoodin4735 3 ปีที่แล้ว +2

      steve myers apparently this box viewed was made in Mexico...part of the nafta trade agreement.

  • @DANIEL-ls5ku
    @DANIEL-ls5ku 2 ปีที่แล้ว +6

    You have a talent to explain step by step well enough even a newbie would feel confident to do this.

  • @joatmofa0405
    @joatmofa0405 3 ปีที่แล้ว

    Excellent "How to DIY" video! Very informative and descriptive narration!!!

  • @hunter.on.channel.19
    @hunter.on.channel.19 3 ปีที่แล้ว +1

    Hey man, iv been out of the group since I built my pack before you started making videos, and just came across your videos...awesome to see you making them!

  • @MiniatureChickenChannel
    @MiniatureChickenChannel 3 ปีที่แล้ว +1

    😍😍This video along with the rest on your channel are outstanding! You've obviously a very good teacher with camera and audio skills too. I'm a noob with more electrical experience than the common dodo....and will be trying this soon. Thanks for all your efforts and keep trucking!!👊👊

  • @powernab8457
    @powernab8457 ปีที่แล้ว +1

    LithiumSolar, you said thanks for watching! Well all I can say is thank you very much for the making the video!! It is really going to help me so I can do my own now 😉👍

  • @cleaverp
    @cleaverp 2 ปีที่แล้ว

    An interesting video. At last, I learnt what that blue tool should be used for. Thanks for posting.

  • @NwAudit
    @NwAudit 2 ปีที่แล้ว

    I love your videos man, they're always filled to the brim with info and excellent tips and tricks to help even the most amateur of solar enthusiasts and make it not so daunting of a task..another great job @LithiumSolar 👍

  • @jonathanbyers9641
    @jonathanbyers9641 ปีที่แล้ว

    This video was super helpful and exactly what I've been looking for.

  • @fisherus
    @fisherus 3 ปีที่แล้ว +2

    Those are clearly clean,compact and tight boxes. Was afraid you had dropped the negative screw you removed down your conduit for a minute. It was close! Another good video and I enjoy learning more new things about solar systems every video.

    • @LithiumSolar
      @LithiumSolar  3 ปีที่แล้ว

      It fell down into the right PV bushing and I had to dig it out. That would have sucked it it would have fallen down the conduit... LOL

  • @AveRage_Joe
    @AveRage_Joe 3 ปีที่แล้ว

    Getting it done like a BOSS!

  • @strehlow
    @strehlow 3 ปีที่แล้ว +15

    If I anticipate trouble getting wires into flex conduit, I'll pull the wires while it is lying straight on the ground, then install it.

    • @peterg.8245
      @peterg.8245 3 ปีที่แล้ว

      They make lube 🤣
      No really you can buy conduit lube for wire pulling, looks like a bucket of what you’d expect an elephant to produce. But try running Russian certified, GOST not UL, cables from a telephone booth sized motor starter 40ft down a skid without it. It was a vapor recovery skid for petrochemicals.

    • @kurtlangeberg1329
      @kurtlangeberg1329 2 ปีที่แล้ว +1

      Exactly. I always run my wires through the conduit first. A hell of alit easier. Especially if your running more than 50 feet.

  • @randybobandy9828
    @randybobandy9828 ปีที่แล้ว

    You always find the best deals on solar/batteries

    • @LithiumSolar
      @LithiumSolar  ปีที่แล้ว

      The deals seem to find me these days...

  • @joeharvie8362
    @joeharvie8362 2 ปีที่แล้ว

    I just scored some 245 watt panels for $50 each used. This video is a great heads up for the project ahead!

  • @issa3522
    @issa3522 2 ปีที่แล้ว

    A very useful video brother and thanks for sharing.

  • @hlkdmegmailcom
    @hlkdmegmailcom ปีที่แล้ว

    Brilliant Tutorial ❤

  • @peterturner7474
    @peterturner7474 ปีที่แล้ว

    A Great guide. Going to improve my set-up with your idea's

  • @youtubeuser2372
    @youtubeuser2372 2 ปีที่แล้ว +1

    Good Quality Work

  • @micaeladelgado76
    @micaeladelgado76 3 ปีที่แล้ว

    Thanks a lot. That was very illustrative.

  • @bradfordpalmer2298
    @bradfordpalmer2298 3 ปีที่แล้ว +5

    There are many PV videos around.
    What I like about yours especially is the safety factor.
    I have always thought DC electricity to be safe and wouldn't take precautions like I do around AC. You point out why DC is dangerous and i need to heed your warnings.

  • @kozicottage
    @kozicottage 3 ปีที่แล้ว

    Great video, very informative! Thanks very much!

  • @AndyMcBlane
    @AndyMcBlane 3 ปีที่แล้ว

    Great video as always Mike

  • @crimpdaddy3559
    @crimpdaddy3559 3 ปีที่แล้ว

    Excellent work.

  • @rak3shpai
    @rak3shpai 3 ปีที่แล้ว +3

    There's no such thing as a water-tight seal. Drill holes on the low-points of your conduit for water to evacuate. This will help with regular weather changes like condensation and pressure changes. You're not waterproof if you don't evacuate water.
    Brilliant video!

    • @peterg.8245
      @peterg.8245 3 ปีที่แล้ว +1

      Better yet install a piece of rigid conduit with a T box and at least a filter drain to keep out the critters.
      When I worked the petrochemical industry we couldn’t allow pooling, because it might be explosive so no flex except for the last 18” and a T and a drain on every low point. The box needs a drain too since condensation will fill to the level of your bushing.

  • @kurtlangeberg1329
    @kurtlangeberg1329 2 ปีที่แล้ว +1

    Nice clean build. Only thing else I would suggest is a lightening surge suppressor.

  • @brentfrank7012
    @brentfrank7012 15 วันที่ผ่านมา

    Great video

  • @hunter.on.channel.19
    @hunter.on.channel.19 3 ปีที่แล้ว +2

    I like that enclosure, 50 bucks is a good deal!

    • @LithiumSolar
      @LithiumSolar  3 ปีที่แล้ว

      Yeah deal is gone unfortunately :(

  • @neomatrix2722
    @neomatrix2722 4 หลายเดือนก่อน

    Thank you for sharing I will be installing my own soon do you have a disconnect as well inside your home like how will you shut off your 600-volt charge controller

  • @cutweldngrind
    @cutweldngrind 3 ปีที่แล้ว

    I have so many crimpers but I need those dies. I do mostly lmr400 cable with mine and other antenna cables. We dont use MC4 connectors at work but bought 10 pairs of them for my personal projects.

  • @RodneySolarCircuits
    @RodneySolarCircuits 3 ปีที่แล้ว

    Another Great Video!

  • @offgridwanabe
    @offgridwanabe 3 ปีที่แล้ว

    I wondered about those fuses instead of breakers but I got 4 years on mine and still same fuses so must be good.

  • @learninghome5396
    @learninghome5396 2 ปีที่แล้ว

    AAAAMAZING EXPLANATION, THANNNNNNNNX

  • @gssrustenburg
    @gssrustenburg 2 ปีที่แล้ว +1

    Awsesome video. Just a question, would it be possible to use dc circuit breakers instead of fuses?

  • @cutweldngrind
    @cutweldngrind 3 ปีที่แล้ว

    I like the Hoffman boxes or at least the ones I used on my solar installations.

  • @chrispfeil6605
    @chrispfeil6605 3 ปีที่แล้ว +1

    Hey Mike, well done - it’s clear you put a bunch of thought and work into this. The whole video I was worried you were going to leave the cover plastic on the box 😂 thanks for showing you removing it hahaha

  • @kpexx
    @kpexx 3 ปีที่แล้ว +2

    Hi , good video,could you telme whwt is the technical name of the negatives conection block? Thank u..

  • @DIYwithBatteries
    @DIYwithBatteries 3 ปีที่แล้ว

    Feels cool to work like that 🤪👍

  • @TexasStatesman
    @TexasStatesman 3 ปีที่แล้ว

    Can you explain how you grounded your panels. I assume you bonded them together with a number #6 copper wire back to the grounding bus bar in the combiner box?

  • @leeh.4729
    @leeh.4729 3 ปีที่แล้ว +2

    Thank you for the video I'm getting ready to set up a 4000 watt pv system did you install a master disconnect some were in the system I was told the system needs one I was looking at the eco worthy combiner box but after seeing this I see that this is the way to go

    • @LithiumSolar
      @LithiumSolar  3 ปีที่แล้ว +2

      I do not have a master disconnect at the panels. I have a main disconnect (PV-rated circuit breaker) at the other end of the wire run.

    • @leeh.4729
      @leeh.4729 3 ปีที่แล้ว

      @@LithiumSolar ok I'll look at that option also

  • @johnjosephhogan4745
    @johnjosephhogan4745 ปีที่แล้ว

    Nice one

  • @NSaw1
    @NSaw1 3 ปีที่แล้ว +1

    My solar array only has 70v max unloaded, so I don't need to worry about high voltages, but I still am careful with it because of arc flash, it's around 1/3 inches long so ya don't want that happening uncontrolled.
    At some point when I have a more permanent array and a higher battery voltage I want to have the panels in a field with a higher voltage so there's less line loss.

  • @chucktrotter9699
    @chucktrotter9699 3 ปีที่แล้ว

    8.30.20 Thanks for the video. For me a learning experience.

  • @hunter.on.channel.19
    @hunter.on.channel.19 3 ปีที่แล้ว +7

    Definitely come back with the panel ground video.

  • @michaelcostello6991
    @michaelcostello6991 2 ปีที่แล้ว

    When you put the fuse in are your fingers contacting the +VE ? This is a great video and i really appreciate the detail you put into it. You brought everyone along. Thank you

    • @LithiumSolar
      @LithiumSolar  2 ปีที่แล้ว +1

      No, the fuse is not making contact on either end at the point of insertion. That would be extremely dangerous if it were.

  • @Kindafu
    @Kindafu ปีที่แล้ว

    what is the arrangement of the panels coming into this box? (series/parallels ect)

  • @brucemarmy8500
    @brucemarmy8500 ปีที่แล้ว +1

    At 5:00 Stop. Do not try to assemble the flex while the connector is in the enclosure. Remove locknut. Build in your hands tighten after assembled in your hands, then mount assembled flex to enclosure with locknut. Support flex within one foot of box. Pull then land output wiring before panel array feeds go into box. You're a good hand, but you are new to electric work.

  • @kennethalmond8922
    @kennethalmond8922 3 ปีที่แล้ว +1

    The Midnite Solar combiner boxes are insanely expensive - but I used them because they allow for an integrated quick disconnect. How do you feel about adding a lightning arrestor? Really enjoy seeing your work progress - thank you for the youtubes!

    • @LithiumSolar
      @LithiumSolar  3 ปีที่แล้ว

      I think that guy is price-gouging lol. As for the lighting arrestor comment - I'm interested, but don't know much about them. Is there one you would recommend? And would that be mounted in the combiner box or near the charge controller?

    • @kennethalmond8922
      @kennethalmond8922 3 ปีที่แล้ว +1

      Yes. I use MIDNITE SOLAR SURGE PROTECTION DEVICE 300VDC AND 120/240 VAC (example pic - www.altestore.com/store/enclosures-electrical-safety/lightning-protection/midnite-solar-surge-protection-device-300vdc-and-120240-vac-p9042/ ) They have a 3/4? pipe thread base - like a conduit connection. Make a hole in the combiner box and wire to the + and - (combined) wiring and grnd. The example above is outdoor quality - I believe its preferred at the combiner box (near the lightning strike) to block a surge going down the wiring into your other stuff. I learned that this protects both the + and - wiring because lightning could go down either wire as lightning doesn't care about current flow direction :)

  • @MRL3234
    @MRL3234 ปีที่แล้ว

    Shade. Is it possible using a combiner box that I could have one array in one part of my yard, and another array quite a distance away in another part of my yard, and if one of the arrays gets substantially shaded that the output from the unshaded array would not be impacted?

  • @Tom111060
    @Tom111060 3 ปีที่แล้ว

    ... should there not be used some cable end sleeves on the solar cables? ( just to reach the 110% mark...)

  • @geofferyromany4634
    @geofferyromany4634 3 ปีที่แล้ว

    last question. the solar array has mc 4 connectors with 12 awg wires both black and red. Ok. but can I use 10awg red and black wires with mc 4 connectors to connect to the combiner box ?
    Thanks

  • @ulven75
    @ulven75 3 ปีที่แล้ว

    Great work.. :-)

  • @jfbaro2
    @jfbaro2 10 หลายเดือนก่อน

    Is there a type of "combiner box" available that can primarily utilize power from solar panels (when sunlight is available) and supplement its output with grid power (as a secondary source) only when the solar current is insufficient to meet the required output?

  • @shermdog6969
    @shermdog6969 2 ปีที่แล้ว

    So is each fuse control one panel? Because 2 panels in parallel would be 20amps with my panels.

  • @stevenlesher8223
    @stevenlesher8223 2 ปีที่แล้ว

    Is it common practice to throw up blanket over the panels if you don't want any output or is that a no no?

  • @off-gridmountaineer4515
    @off-gridmountaineer4515 3 ปีที่แล้ว +2

    Yes just wondering what size was the liquid sealed conduit pipe i am thinking it was 3/4 but not really for sure and I am a big fan and have learn so much on your Channel thank you for everything you do it really helps a lot because they are no classes in my area teaching how to do solar batteries inverters Etc so again thank you for everything you put on your Channel

    • @LithiumSolar
      @LithiumSolar  3 ปีที่แล้ว +2

      It is 3/4 LFMC conduit. If you're unsure what size to use for your application, this is a good calculator www.southwire.com/calculator-conduit NEC states max of 40% fill for 3+ conductors :)

    • @off-gridmountaineer4515
      @off-gridmountaineer4515 3 ปีที่แล้ว +1

      @@LithiumSolar thank you so much

  • @pulesjet
    @pulesjet 3 ปีที่แล้ว +2

    I purchased the same Crimper some time back. Prior to that I was just using needle nose loaded with butt loads of bad words.

    • @LithiumSolar
      @LithiumSolar  3 ปีที่แล้ว

      SAME. I was using needle nose then soldered, but sometimes it wouldn't fit in the connector due to solder - also resulting in butt loads of bad words. I wish I knew better back then.

    • @pulesjet
      @pulesjet 3 ปีที่แล้ว

      @@LithiumSolar Yep, the right tool makes life a bunch smoother.

  • @khaleddhr6238
    @khaleddhr6238 ปีที่แล้ว

    Ok, but if i want to disconnect pv + and pv - from inverter 1 and put it to inverter 2 , what is need to switch from home to diconnect all array pv or need to go box to disconnect all fuses?

  • @rashidsolarsolutions
    @rashidsolarsolutions 2 ปีที่แล้ว

    Nice

  • @jmonsted
    @jmonsted 3 ปีที่แล้ว +2

    did you plug the unused holes in the rubber plug with something?

    • @LithiumSolar
      @LithiumSolar  3 ปีที่แล้ว +1

      Not yet. I have a 5th string to connect and a ground wire yet, which will leave me with one unused hole. I'll just stick a small piece of PV cable in to plug it.

  • @serhatbaris
    @serhatbaris 3 ปีที่แล้ว

    how many kw was it made for a system?

  • @peterg.8245
    @peterg.8245 3 ปีที่แล้ว +1

    I’m surprised it didn’t come with a shield for the bus bar for IP20 rating.
    Also you’ll want an enclosure drain to prevent condensation accumulating and rusting out the bottom of the box. It will fill up until it spills into the flex and then flood the lower end and test the insulation until it shorts against the conduit.

    • @LithiumSolar
      @LithiumSolar  3 ปีที่แล้ว +1

      I'm curious if you've seen this happen before? I've heard a lot of people mention condensation in conduit and I've yet to see it happen in any of my conduits (I have a lot of them). I'm not saying it's impossible, just... seems odd. Unless it's something that occurs over like 20 years or so?

    • @GUIRADE95
      @GUIRADE95 3 ปีที่แล้ว +1

      @@LithiumSolar disaster is around 24/7 no matter what! Best way to avoid condensation is to check every now and then and dry up any signs of moisture. You will be surprised the kind of things I have found inside those boxes, spiders, all kinds of insect's, moisture, and rust. Even if they are new and built with the best materials I always do a routine maintenance on those boxes. Excellent set up, keep up with the good work! Kind regards from BC.

  • @bernardcharlesworth9860
    @bernardcharlesworth9860 ปีที่แล้ว

    Nice video but is it ok with no negative fuse.

    • @LithiumSolar
      @LithiumSolar  ปีที่แล้ว +1

      I have a 2-pole circuit breaker at the charge controller. Whether or not this box is ok (with a positive-only fuse) will depend on your local codes.

  • @geofferyromany4634
    @geofferyromany4634 3 ปีที่แล้ว

    what is the size of the green wire? rookie questions I know

  • @bestillandknowthatuaregod
    @bestillandknowthatuaregod 2 ปีที่แล้ว +1

    Do you need 3 To 1 Y Type MC4 Branch Solar connector if using a combiner box? THANKS, I have 6 panels...

    • @LithiumSolar
      @LithiumSolar  2 ปีที่แล้ว

      No. The combiner box takes the place of the Y adapters. I don't like the Y adapters personally. It's very easy to accidentally overload the connectors or wires.

  • @mrchrisknight315
    @mrchrisknight315 ปีที่แล้ว

    Instead of running panels in series, would it be beneficial to use a combiner so that all panels work at there best, and aren't affected by a panel being shaded? I only have 3 430 watt panels that I use with a bluetti ac 200max. I'm thinking if this is the case I'd maximize my charging.

    • @LithiumSolar
      @LithiumSolar  ปีที่แล้ว +1

      The controllers I'm using require a minimum voltage of 60Vmp to run. Most MPPT controllers will have a minimum voltage exceeding that of a single panel.

  • @centerrightproudamerican5727
    @centerrightproudamerican5727 2 ปีที่แล้ว

    I wonder if there is a requierment to connect the metal of that conduit to ground...???

    • @LithiumSolar
      @LithiumSolar  2 ปีที่แล้ว

      The conduit is bonded to the metal case. The lock ring that is screwed down on the conduit fitting has teeth that bite in to the box metal (through the paint). They do make some rings that also have a ground wire terminal on them - up to your local codes if that's required.

  • @unionse7en
    @unionse7en 6 หลายเดือนก่อน

    Hmm never made a later video about the frames EGC to the busbar connection or the inverter end of the EGC ?

    • @LithiumSolar
      @LithiumSolar  6 หลายเดือนก่อน

      Nope. This was connected to an isolated controller so I never had it grounded. It's since been replaced and grounded properly now. I would suggest following all electrical codes/requirements for your area!

  • @decal2154
    @decal2154 2 ปีที่แล้ว +1

    How did you determine the size of the wire for the combiner box? Thanks

    • @LithiumSolar
      @LithiumSolar  2 ปีที่แล้ว

      I always reference the NEC code, section 310.16 as a starting point. There is more that goes in to it beyond this though, such as length of wire, bundling, etc. You can find the table on Google fairly easily.

  • @pulesjet
    @pulesjet 3 ปีที่แล้ว

    Our Pack Rats must like the taste of the wire. You have to use PVC to armor the wire.

  • @nikonopp
    @nikonopp 3 ปีที่แล้ว

    Could you visit Corridor Cast some time ?

  • @josephnevin
    @josephnevin 3 หลายเดือนก่อน +1

    Is it a good habit to solder the wire at the crimped part to get a better electrical connection?

    • @LithiumSolar
      @LithiumSolar  3 หลายเดือนก่อน +1

      Absolutely not! It may sound like a good idea, but you're creating a weak point on the wire that's subject to breaking if/when it flexes. Additionally, you're filling the terminal with a metal that softens and melts at a very low temperature (ie if the connection starts to heat up for whatever reason). A proper crimp is superior to solder in this application.

    • @josephnevin
      @josephnevin 3 หลายเดือนก่อน

      @@LithiumSolar thanks for that valuable tip.

  • @jeremycrisp4488
    @jeremycrisp4488 2 ปีที่แล้ว

    If you can easily feed your wire through your conduit, don't cut the excess, just push it to the other end, so you will have on long piece of excess wire instead of two shorter pieces.

  • @debbies3763
    @debbies3763 2 ปีที่แล้ว

    HOW MANY PANELS 4 TOTAL, EIGHT WIRES?

  • @clayherzog4220
    @clayherzog4220 28 วันที่ผ่านมา

    Great video. Might be good to point out that these are knock-off MC4 connectors that are shown and shouldn't be cross-mated with look-alikes, including true (Staubli) Multi-Contact MC4s.

    • @LithiumSolar
      @LithiumSolar  27 วันที่ผ่านมา

      They are not, nor do they claim to be, Staubli-brand.

  • @ginnadelinois5999
    @ginnadelinois5999 2 ปีที่แล้ว

    Can i use it for wind turbine and solar

    • @LithiumSolar
      @LithiumSolar  2 ปีที่แล้ว

      I'm not familiar with the requirements of wind power.

  • @GroovyVideo2
    @GroovyVideo2 2 ปีที่แล้ว

    mc4 metal contact area between m/fm is very small -
    they were designed Long ago when panel output was a few watts

  • @hubertnnn
    @hubertnnn 3 ปีที่แล้ว

    Is it possible to turn around the bus bar on the right?
    I think it would be easier if you loop the charge controller wire, and connect all the solar panel wires from the bottom.

    • @peterg.8245
      @peterg.8245 3 ปีที่แล้ว +1

      Daves Tech no top penetrations on outdoor NEMA 4 enclosures

    • @LithiumSolar
      @LithiumSolar  3 ปีที่แล้ว +1

      Yes, the bar could have been turned around. It's just held in by a pair of phillips screws. I suppose that would have made it easier, hadn't thought of that.

    • @LithiumSolar
      @LithiumSolar  3 ปีที่แล้ว

      And yes, no top penetrations. I don't even like side connections (have one on another unrelated box).

    • @hubertnnn
      @hubertnnn 3 ปีที่แล้ว

      @@davestech6357 Top connections are risky for being water proof. If you have even the smallest leak then in top connections water will drip inside, while in bottom its unlikely.

  • @gardenwonders3308
    @gardenwonders3308 2 ปีที่แล้ว +1

    So should the combiner box be close to your panels as opposed to next to your inverter. So then you run a thicker 6 ga wire to the house, eh?

    • @LithiumSolar
      @LithiumSolar  2 ปีที่แล้ว

      Typically they're installed at the solar panels, then one set of conductors run back to the inverter. However, please make sure to check and follow your local codes/requirements.

  • @awesomedee5421
    @awesomedee5421 2 ปีที่แล้ว

    Were is the link to that fancy tool to disconnect the MC4?

    • @LithiumSolar
      @LithiumSolar  2 ปีที่แล้ว

      The crimp tool kit includes 2 of the MC4 connect/disconnect tools watts247.com/product/mc4-solar-crimping-tool-kit-crimper-for-2-5-6-0mm2-solar-panel-pv-connectors-cable/?wpam_id=97

    • @awesomedee5421
      @awesomedee5421 2 ปีที่แล้ว

      @@LithiumSolar okay, I saw that but the tool you were talking about to replace the needle nose pliers I didn't see. Is that the same thing as what is in the spine of that kit?

    • @LithiumSolar
      @LithiumSolar  2 ปีที่แล้ว

      @@awesomedee5421 Yes, it's the same thing. In reference to the tool shown in the spine of the kit, the round part is for tightening the nut down where the wire goes in to the connector when splicing new connectors on. The two points on the other end are the disconnect tool. They will go over the MC4 and press the two tabs in for removal.

  • @debbies3763
    @debbies3763 2 ปีที่แล้ว

    DO I NEED 2 HOFFMAN BOXES FOR 10 100WATT PANELS?

  • @daviddenson3324
    @daviddenson3324 3 หลายเดือนก่อน

    Two questions:
    1) What gauge grounding wire did you use coming from the array?
    2) Did you also run ground wire from the ground bus bar to a grounding rod in the ground? And if so what was the gauge ground wire to that ground rod?

    • @LithiumSolar
      @LithiumSolar  3 หลายเดือนก่อน

      You should ground it in accordance with the code requirements in your area.

    • @daviddenson3324
      @daviddenson3324 3 หลายเดือนก่อน

      @@LithiumSolar right but I was still curious what gauge ground wire you used and if you installed a ground rod and wire to the combiner as well

    • @LithiumSolar
      @LithiumSolar  3 หลายเดือนก่อน

      6 from panels to combiner, 10 from combiner back to shed.

    • @daviddenson3324
      @daviddenson3324 3 หลายเดือนก่อน

      @@LithiumSolar gotcha, thanks

  • @rustusandroid
    @rustusandroid 2 ปีที่แล้ว +1

    Can you help me understand why you needed a combiner box for six panels? I would assume for that small of an array, you would just make 1 string and only have 2 wires to deal with at the end anyway.

    • @LithiumSolar
      @LithiumSolar  2 ปีที่แล้ว

      I have 15 panels. My charge controller (like most off-grid controllers) is limited to 150Voc input. Because of this, I can only wire 3 of the panels in series before I risk exceeding 150Voc. So I have 5 strings I need to combine.

    • @rustusandroid
      @rustusandroid 2 ปีที่แล้ว

      @@LithiumSolar Ahhh, I misunderstood. That would do it then. Most of the UL listed Hybrid converters I see go up into the 480 -580v range. But yes, 150v would limit you. Thanks for the quick response!

    • @LithiumSolar
      @LithiumSolar  2 ปีที่แล้ว

      ​@@rustusandroid My system is 100% off-grid. A hybrid system is still technically grid-tie and requires piles of permits, contracts, and approvals :)

    • @rustusandroid
      @rustusandroid 2 ปีที่แล้ว

      @@LithiumSolar True that. Maybe I should watch more of your videos before I start running my mouth :)

  • @BastelPichi
    @BastelPichi 3 ปีที่แล้ว +3

    Couldt you make a solar generator, thats in a solar panel? Wouldt be very happy, i love your videos

  • @mattwesolowski5394
    @mattwesolowski5394 2 ปีที่แล้ว

    Shouldn’t the fuse busbar be on the other side? The left side was hot when you dropped the fuse in..

    • @LithiumSolar
      @LithiumSolar  2 ปีที่แล้ว

      The fuse doesn't make contact on either end until you close the fuse holder.

  • @sreekumarUSA
    @sreekumarUSA 3 ปีที่แล้ว

    083120/0104pst Thanks once again for the meticulous procedure. stay safe and 73s...

  • @wipatriot510
    @wipatriot510 2 หลายเดือนก่อน

    How many panels in each string, and what are the values of the panels, Voc, Vmp, Imp, Isc..??? Are they 12v or 24v panels, wattage each panel...???
    I think you can gleen the information I'm looking for...

    • @LithiumSolar
      @LithiumSolar  2 หลายเดือนก่อน

      I'm not going to go through and collect this information. I'm not sure what you're looking for, but the label on the inside of the box lists out the specifications for the enclosure.

    • @wipatriot510
      @wipatriot510 2 หลายเดือนก่อน

      @@LithiumSolar I wasn't referring to the enclosure...and by me listing the info I requested, and you not being "sure" as to what I'm looking for tells me that you have 1) no idea what you're doing, 2) no business guiding other people...

    • @LithiumSolar
      @LithiumSolar  2 หลายเดือนก่อน

      @@wipatriot510 This video is nearly 4 years old. How do you expect me to spout off those numbers and calculations nearly 4 years later? I'm not going to run around like a puppy and gather this because some random commenter asks. Additionally, this box isn't even installed anymore. You should be following your local codes, requirements, and regulations, not relying on a TH-cam video.

    • @wipatriot510
      @wipatriot510 2 หลายเดือนก่อน

      @@LithiumSolar It's BASIC information...and if you're not here to make reliable content, then you shouldn't be on youtube at all...

  • @stevemyers2092
    @stevemyers2092 3 ปีที่แล้ว +1

    pound a 6'-8' bar into the ground and put a mechanical clamp (elect supply store) or you can Cad Weld/Exothermic, and attach your ground wire from that to your box buss bar. Your resistance should have 5 ohms or less - no more if possible = All good.

    • @LithiumSolar
      @LithiumSolar  3 ปีที่แล้ว

      I do have an 8ft ground rod already pounded in. I guess I'm just not sure what gauge wire and proper clamps to use. You mentioned max 5 ohms, are you measuring that between the solar panel frame and the grounding rod?

    • @BobHannent
      @BobHannent 3 ปีที่แล้ว

      Yea, I am working on my install and bought a grounding rod, not sure where to measure the resistance

    • @stevemyers2092
      @stevemyers2092 3 ปีที่แล้ว

      @@BobHannent anywhere along the ground works the same. 5 ohms or less is a pass for any electrician. 0 is the best. I am a CM.

    • @stevemyers2092
      @stevemyers2092 3 ปีที่แล้ว

      @@BobHannent code says 8' rod but 6' works what doesn't work it hitting a rock 3' down then cutting it off so it looks like 8' lol

    • @stevemyers2092
      @stevemyers2092 3 ปีที่แล้ว

      @@BobHannent i have built 100's of telecom cell sites rooftop and dirt(greenfield). .

  • @TigTex
    @TigTex 3 ปีที่แล้ว +1

    Quick question, is 90VDC really dangerous? If I'm not mistaken, you can't even feel it. 90VAC is another story

    • @LithiumSolar
      @LithiumSolar  3 ปีที่แล้ว +2

      Yes. I can feel 48V and it stings. I don't want to know what 90V feels like...

    • @joaoncr
      @joaoncr 3 ปีที่แล้ว

      Vdc is even worst

    • @approsetn
      @approsetn ปีที่แล้ว

      Generally anything 50 volts or higher is considered to be capable of killing you.

  • @geofferyromany4634
    @geofferyromany4634 3 ปีที่แล้ว

    I am a beginner in this area so bear with my foolish questions. First, why did you use 6 awg red wire for the positive and 12 awg black for the negative? should you not use 6 awg black wire?

  • @geofferyromany4634
    @geofferyromany4634 3 ปีที่แล้ว

    sorry saw my mistake after watching video 3 times just to be sure

  • @daninwy2681
    @daninwy2681 2 ปีที่แล้ว

    Just my luck the little screw would fall down into the conduit.

  • @ftshinanigans
    @ftshinanigans 3 ปีที่แล้ว +2

    next time tape all conductors together and pull it in 1 shot it's a lot easier

    • @LithiumSolar
      @LithiumSolar  3 ปีที่แล้ว +1

      I would have done it that way if I were pulling rather than pushing it through. I figured it would have been too thick and stiff to get around the 90 bends, but maybe not.

  • @johnmirbach2338
    @johnmirbach2338 3 ปีที่แล้ว +1

    😁✌🖖👌👍😎

  • @matthewknight5641
    @matthewknight5641 ปีที่แล้ว +1

    Why not connect all the wires onto the breakers then set breaker in place on the rail?? Way easier!!!

    • @LithiumSolar
      @LithiumSolar  ปีที่แล้ว

      That sounds more difficult to me. You're welcome to do yours how you see fit 🙂

  • @veritya3
    @veritya3 3 ปีที่แล้ว

    Measure twice, cut once

  • @GUIRADE95
    @GUIRADE95 3 ปีที่แล้ว

    I've seen a lot of rookie engineer's making the most stupid mistakes working around boxes like this, the worst is that they open a "company" offering their services very very cheap! That has cost us, the professionals in this field the loss of revenue, but, many times they call us back to fix the stupidities done by the rookies! 40 years of experience you don't get it even if you go to the most prestigious universities or technical garage schools. Electricity is deadly in many ways, either DC or AC. I never take short cuts, I know about many people being killed because a simple mistake. Take it seriously! Electricity can kill!

  • @sunjayjay240
    @sunjayjay240 ปีที่แล้ว

    Thanks a lot
    you did not show out put voltage
    better show that

  • @markroberts1142
    @markroberts1142 ปีที่แล้ว

    Why do people not cut ends off cable ties.....shreek.

    • @LithiumSolar
      @LithiumSolar  ปีที่แล้ว

      I do cut all ends off cable ties.

  • @alext8828
    @alext8828 3 ปีที่แล้ว +2

    Try to stay away from those screws you're using on the conduit. They're drywall screws and they rust and are very brittle. Tighten them too hard and they snap off.

    • @LithiumSolar
      @LithiumSolar  3 ปีที่แล้ว +2

      They are exterior decking screws :)

    • @alext8828
      @alext8828 3 ปีที่แล้ว +1

      @@LithiumSolar Yeah, not really the best choice. The bugle head is wrong for this application. Just saying. Otherwise, great job.

    • @LithiumSolar
      @LithiumSolar  3 ปีที่แล้ว +1

      @@alext8828 Thanks. I'm not overly-familiar with hardware like this. I use deck screws pretty much everywhere. Is there a specific kind you would recommend?

    • @alext8828
      @alext8828 3 ปีที่แล้ว +1

      @@LithiumSolar A wood screw with a flat bottom to press down with its entire surface rather than a bugle head that tries to displace material as it goes in. Excellent job.

    • @josephbrabenderiii2049
      @josephbrabenderiii2049 2 ปีที่แล้ว

      @@LithiumSolar Your local big box store will have hex washer head "sheet metal" screws in stainless steel to size 14 (1/4") in various lengths. "Lag screws" in still larger diameters.