Second opinion, low voltage short identified.

แชร์
ฝัง
  • เผยแพร่เมื่อ 24 พ.ย. 2024

ความคิดเห็น • 21

  • @garza7676
    @garza7676 3 ปีที่แล้ว +7

    If I suspect it’s a broken low voltage wire . I go to the air handler and connect the wires together and then go to the outside unit and do a Continuity test , no beeping noise means there’s a break in the wires .

  • @andresperez-wc8ty
    @andresperez-wc8ty 3 ปีที่แล้ว +4

    Great vid! Quick tip if you suspect a wire thats cut; with all power off, at the condenser wire nut the wire u suspect is bad to another wire and go back to the thermostat so you dont have to climb and and check for continuity between the 2 wires. If the wire is cut you ll have no continuity. This is only for cut wires not shorted ones.

  • @a11ten071
    @a11ten071 3 ปีที่แล้ว +3

    Appreciate the ride along👍

  • @kevonslims7269
    @kevonslims7269 2 ปีที่แล้ว +2

    As a secondary check always disconnect the low voltage from the contractor and check for voltage, sometimes a partially shorted contractor coil can give you no 24 volts.

  • @gods959
    @gods959 ปีที่แล้ว

    👍 good stuff I just found my yellow wire short going to the outside of the house. Rats chewed the wire and it was blowing 3 amp fuse because it was on top of naked cooper pipe.

  • @sknight0391
    @sknight0391 3 ปีที่แล้ว +3

    You should have hooked up a Sparkomatic 6x9 speaker at the outdoor unit and see if it would have played some Motley Crue.
    😂👌
    #speakerwire

  • @97Napkins
    @97Napkins 3 ปีที่แล้ว

    Glad you got the Job!

  • @oscarestrada5509
    @oscarestrada5509 3 ปีที่แล้ว +1

    My friend use a short pro tool that what I use to fix the short or continuity is very easy to find the broken wire I've been fixing a lot of this

  • @FrankieGN
    @FrankieGN 3 ปีที่แล้ว

    Looking forward to that vid tomorrow!

  • @roberts1159
    @roberts1159 3 ปีที่แล้ว +1

    Interesting service call. Why was the yellow wire at thermostat disconnected? Previous company? Take us along whenever you replace the wiring. Thanks for sharing.

  • @williamgildea8348
    @williamgildea8348 3 ปีที่แล้ว

    Love the videos. What veto are you using?

    • @HVACGUY
      @HVACGUY  3 ปีที่แล้ว +1

      I actually got three. My daily bag though is the backpack. The other two are smaller, one of which is my camera bag

  • @donnierobertson3088
    @donnierobertson3088 3 ปีที่แล้ว

    Nice

  • @97Napkins
    @97Napkins 3 ปีที่แล้ว

    Thought was going to be a voltage drop due to under size wire but was zero.

    • @ck9581
      @ck9581 3 ปีที่แล้ว

      Don’t you mean under sized

  • @realestateservicessaleshea99
    @realestateservicessaleshea99 3 ปีที่แล้ว +1

    To be continued...
    🍺🍇🥃🥃🍺🍺🏌
    Stay safe.
    Retired(werk'n) keyboard super tech.
    Wear your safety glasses.

  • @steveblake8766
    @steveblake8766 3 ปีที่แล้ว

    #50 thumbs up

  • @cutum
    @cutum 3 ปีที่แล้ว

    You think rats chewed the line?

    • @HVACGUY
      @HVACGUY  3 ปีที่แล้ว +1

      not on this one. I didn’t see any breaks in the line, and I could see most of it.

  • @markchambers2812
    @markchambers2812 3 ปีที่แล้ว

    I was thinking short

    • @arniegrote319
      @arniegrote319 3 ปีที่แล้ว

      Not a Short, This would be a open line.