    In this series, we will introduce the current transformer and will give an example where we would want to use a CT. We'll also look at polarity marks for CTs and talk about the current transformer ratio and how to relate primary current to secondary current. Then we will take three CTs and connect them to the WYE and delta connection. In the last, we will draw the current transformer model and show the voltage currents and impedance's that are associated with the CT model.
    Get 𝟗𝟎% 𝐎𝐅𝐅 on 𝐂𝐮𝐫𝐫𝐞𝐧𝐭 𝐓𝐫𝐚𝐧𝐬𝐟𝐨𝐫𝐦𝐞𝐫 𝐅𝐮𝐧𝐝𝐚𝐦𝐞𝐧𝐭𝐚𝐥 𝐂𝐨𝐮𝐫𝐬𝐞: bit.ly/40XMpwC
    𝐏𝐋𝐀𝐘𝐋𝐈𝐒𝐓: gpac.link/35hZyFG
    Know Abdur Rehman, Creator & Co-founder of GeneralPAC by AllumiaX: bit.ly/Abdur-R...
    Read our blog on "Current Transformer". The current transformer is an essential part of the power system. The basics of the current transformer including construction, applications, working principles are going to be discussed in this article. Click here: gpac.link/3kozYom
    #GeneralPAC #CurrentTransformer #CT
    𝐖𝐞 𝐧𝐞𝐞𝐝 𝐲𝐨𝐮𝐫 𝐬𝐮𝐩𝐩𝐨𝐫𝐭...𝐖𝐡𝐲?
    An incredible amount of time and effort is needed to develop high-quality video tutorials. Each video (Part 1 for example) takes approximately 10 hours to complete which includes learning the concept ourselves, brainstorming creative ways to teach and explain the concepts, writing the script, audio recording, video recording, and editing. This is why Hundreds-of-Thousands of people have watched, liked, subscribed, and left positive comments on our TH-cam channel. Your support truly makes all the difference. Please donate and 𝐛𝐞𝐜𝐨𝐦𝐞 𝐨𝐮𝐫 𝐩𝐚𝐭𝐫𝐨𝐧 by clicking here: / generalpac
    𝐅𝐨𝐥𝐥𝐨𝐰 𝐆𝐞𝐧𝐞𝐫𝐚𝐥𝐏𝐀𝐂 𝐨𝐧:
    TH-cam: / generalpac
    LinkedIn: / generalpac
    Facebook: / generalpac
    Patreon: / generalpac
    𝐒𝐮𝐛𝐬𝐜𝐫𝐢𝐛𝐞 𝐮𝐬: gpac.link/2C1r1gu
    AllumiaX exclusively works with Electrical Contractors, Distributors, and other Engineering Companies. 𝐊𝐧𝐨𝐰 𝐦𝐨𝐫𝐞 𝐚𝐛𝐨𝐮𝐭 𝐨𝐮𝐫 𝐜𝐨𝐫𝐩𝐨𝐫𝐚𝐭𝐞 𝐬𝐩𝐨𝐧𝐬𝐨𝐫:
    Website: allumiax.com/
    Twitter: / allumiax
    LinkedIn: / allumiax
    Facebook: / allumiax
    Instagram: / allumiaxengineering
    Power System courses: www.allumiax.c...
    𝐆𝐞𝐧𝐞𝐫𝐚𝐥𝐏𝐀𝐂 𝐛𝐲 𝐀𝐥𝐥𝐮𝐦𝐢𝐚𝐗 - 𝐌𝐚𝐤𝐢𝐧𝐠 𝐏𝐨𝐰𝐞𝐫 𝐒𝐲𝐬𝐭𝐞𝐦𝐬 𝐈𝐧𝐭𝐮𝐢𝐭𝐢𝐯𝐞, 𝐎𝐩𝐞𝐧 𝐚𝐧𝐝 𝐅𝐫𝐞𝐞 𝐭𝐨 𝐄𝐯𝐞𝐫𝐲𝐨𝐧𝐞, 𝐄𝐯𝐞𝐫𝐲𝐰𝐡𝐞𝐫𝐞!

ความคิดเห็น • 45

  • @Generalpac
    @Generalpac  2 หลายเดือนก่อน

    🔥 Want to become a power systems expert? Our ALL IN ONE Bundle offers 11 courses for only $99.99! Don't miss out on this incredible opportunity to level up your knowledge. Enroll now! 🔗 bit.ly/ALL-IN-ONE-POWER-SYSTEM-BUNDLE

  • @fioricoziuc1792
    @fioricoziuc1792 3 ปีที่แล้ว +1

    I knew it that in the primary the current should " goes in" where the primary dot is. But I was not aware that the secondary current has to " goes out" in the secondary dot... Thank you again!

    • @Generalpac
      @Generalpac  3 ปีที่แล้ว

      Glad you like them! You might also be interested in our Power System Fundamental courses. Get started with FREE courses here: gpac.link/2GO6m4X.
      You can support us by becoming our Patron on patreon.com/generalpac. Make a difference and be a contributor to the GeneralPAC community.
      Thanks
      GeneralPAC Team.

  • @raja-righteousrhetorics4516
    @raja-righteousrhetorics4516 5 ปีที่แล้ว

    Plz continue ur work... much handy and informative for people... thanks

  • @milesrowe2263
    @milesrowe2263 3 ปีที่แล้ว

    thank you for making these videos

    • @Generalpac
      @Generalpac  3 ปีที่แล้ว

      Glad you like them! You might also be interested in our Power System Fundamental courses. Get started with FREE courses here: gpac.link/2GO6m4X.

  • @UnbornAssassin7
    @UnbornAssassin7 7 ปีที่แล้ว

    These are very helpful, thank you

  • @amyxie2011
    @amyxie2011 3 ปีที่แล้ว

    Thanks for the explanation it’s really good! What software are you using to write?

  • @acoustic4037
    @acoustic4037 4 ปีที่แล้ว +1

    Does anyone know why it is an issue since alternating current goes both ways?

  • @ganeshk2404
    @ganeshk2404 6 ปีที่แล้ว

    Is any possibility to physically check type of Dot used in CT ? And the grounding of secondary terminal make any change on polarity?

  • @marcusrose9189
    @marcusrose9189 2 ปีที่แล้ว

    So in your 4th drawing, 5:22, wouldn't this cause a malfunction of your relay? Due to your polarity being incorrect as current should flow into it? This also relates to faults within the transformer, wouldn't this cause an issue as the direction of current travelling to switch due to the fault?

    • @Generalpac
      @Generalpac  2 ปีที่แล้ว +1

      Hey Marcus,
      You are right. This video is just for the understanding purpose that how current flows through CTs primary and secondary for different scenarios.

  • @fransjack1234
    @fransjack1234 8 ปีที่แล้ว

    hi sir ...can i use three CT in wye to connect them to my automatic meter reading..? thanks

  • @norhafizie1883
    @norhafizie1883 4 ปีที่แล้ว

    Hi. I found during installation that CT's are marked P1-P2 and S1-S2. Could you explain according to this symbol, as I am always confused which one should be grounded/connect to relay whether S1 or S2.

    • @Generalpac
      @Generalpac  4 ปีที่แล้ว +1

      Hi Nor Hafizie, Thank you for reaching out and sharing your concern with us. GPAC team will try its best to address it.
      The CT's primary winding connection are denoted as "P1" and "P2" (in some cases "K" and "L") and secondary windings as "S1" and "S2" (or "k" and "l"). For primary, the connections are made in such a way that P2 is the load facing side and the energy flows from P1 to P2. For secondary remember to use the same rule for the directional flow of energy from S1 to S2. Also, you can either connect S1 and S2 to the ground terminal. However, for protective relays, ground that terminal which is nearest to the protected equipment.
      Hope so this answer is helpful to you. You can support us by becoming our Patron on patreon.com/generalpac. Make a difference and be a contributor to the GeneralPAC community.
      Thanks
      GPAC Team

    • @nadakhater23
      @nadakhater23 2 ปีที่แล้ว

      @@Generalpac Thank u 4 all the effort
      And please I wanna ask
      If the ct was installed reversed as p2 is towards the source and p1 towards the load then i reversed s1 and s2 into the measuring device is that correct????

    • @emnuc30
      @emnuc30 ปีที่แล้ว

      @@nadakhater23 It depends on the drawing and specs and application of the CTs. To keep polarity the same, then yes.

  • @basyoni95
    @basyoni95 8 ปีที่แล้ว

    I have a problem with the dot convention. "out of the dot" could be in any direction right ?

    • @basyoni95
      @basyoni95 8 ปีที่แล้ว

      okay I kinda get it now. the dot is like a portal, the current keeps it's direction but in a different place. is that right ?

    • @basyoni95
      @basyoni95 8 ปีที่แล้ว +1

      god damn it :(

    • @jackyhan4622
      @jackyhan4622 8 ปีที่แล้ว

      "out" from the winding, to the load

  • @mohamednasr6529
    @mohamednasr6529 6 ปีที่แล้ว

    isn't the connection of the c.t s at star side should be collected as delta connection to remove the
    phase shift in the main transformer between delta and star windings or what??????!!!!!

  • @Generalpac
    @Generalpac  4 ปีที่แล้ว +2

    Hey you guys, thanks for the feedback. For all our upcoming videos we won't add any music. Unfortunately, TH-cam doesn't allow us to remove the music from previously uploaded videos. Thank you for your understanding.
    -GeneralPAC team

  • @jimshenry6656
    @jimshenry6656 7 ปีที่แล้ว

    I need help. I am confused with the dot convention. Out of the dot could be in either direction isn't it? please help me out.

    • @Generalpac
      @Generalpac  7 ปีที่แล้ว

      +Jims Henry not sure what you mean... Can you elaborate? Thanks,

    • @rickhamel8578
      @rickhamel8578 6 ปีที่แล้ว +1

      It is with respect to the CT. Flowing into the dot would mean the current moves from the dot through the winding. Out of the dot means current flows from the dot away (or out) from the winding.

  • @ahtishampervez5021
    @ahtishampervez5021 6 ปีที่แล้ว +3

    This background music is very disturbing

    • @Generalpac
      @Generalpac  6 ปีที่แล้ว +1

      Thanks for the feedback. We have received a lot of feedback on the background music. Now, we have totally removed it from our New videos.
      You can check our new series - "Brief Introduction to CT and Its Applications"
      yt.vu/p/PLqJ0Y2s60r-5twLWQpqUX6jA8V9AQBryv

  • @JSunday45
    @JSunday45 ปีที่แล้ว

    I came to understand why is there a polarity in an AC system. Still can't. If anyone can help me understand will be grateful.

    • @Generalpac
      @Generalpac  ปีที่แล้ว +1

      Hi Yordan, the polarity here basically refers to the flow of current not the direction of the current. You can say that a current starts flowing from generation to transmission and then to load (distribution).
      Hope you find it useful.
      Regards,
      GeneralPAC by AllumiaX

    • @JSunday45
      @JSunday45 ปีที่แล้ว

      @@Generalpac I got that. Also found that the meter finds the direction due to a current/voltage offset of 180-degrees. Gues s I still find it hard to comprehend how dose a 180-degree current offset actually feeds in the grid. I thought that to feed the grid all vectors must be the same.

  • @Generalpac
    @Generalpac  10 หลายเดือนก่อน

    🎁 Enter the Thanksgiving Power System Pack Giveaway with your email! 🍀 One lucky winner will receive the Power System Fundamental Pack on November 23rd, and ALL participants get a FREE top-selling course. 📚
    Sign in: bit.ly/thanksgiving-day-2023

  • @Generalpac
    @Generalpac  ปีที่แล้ว

    In Current Transformer course we will start from very basics: This course combines brief introduction to Current Transformer with its main characteristic and applications. You will emerge with the knowledge in principles, working, applications, sizing of CT that empowers you to have strong grip on the fundamentals of Current Transformer. This module consists of three parts, each building upon your knowledge based on previous ones. Get 𝟗𝟎% 𝐎𝐅𝐅 on 𝐂𝐮𝐫𝐫𝐞𝐧𝐭 𝐓𝐫𝐚𝐧𝐬𝐟𝐨𝐫𝐦𝐞𝐫 𝐅𝐮𝐧𝐝𝐚𝐦𝐞𝐧𝐭𝐚𝐥 𝐂𝐨𝐮𝐫𝐬𝐞: bit.ly/Current-Transformer-90OFF

  • @Generalpac
    @Generalpac  ปีที่แล้ว

    AllumiaX is Wishing you a joyful Independence Day!”. On this special day we are offering an amazing discount on our top-notch POWER SYSTEM COURSES, available for just $9.99 each. Valid until July 15, 2023. So, hurry and make the most of it before it's gone!
    Click here: bit.ly/power-systems-courses

  • @Generalpac
    @Generalpac  11 หลายเดือนก่อน

    98% OFF | EARLYBIRDS DISCOUNT
    Sign up for our newly launched courses at 98% OFF. New video releases will be scheduled on a monthly basis. Grab this opportunity before it ends. bit.ly/earlybirds-discount

  • @Generalpac
    @Generalpac  9 หลายเดือนก่อน

    YEAR-END SALE: Up to 95% OFF: bit.ly/power-systems-courses
    As 2023 comes to an end, it's time to take a breather and reflect on your journey this year. This isn't just about recognizing your wins and bumps in the road-it's also an opportunity to identify areas for growth, particularly in your learning goals. Lucky for you, our BIG END-OF-YEAR SALE is here to support you in achieving Your goals!

  • @satyanarayanamurthy3245
    @satyanarayanamurthy3245 6 ปีที่แล้ว +1

    background ground music is very harassment to viewers.please switch off back ground mudic

    • @Generalpac
      @Generalpac  6 ปีที่แล้ว

      This was one of our first videos... and YES, we hear you loud and clear. All of our new videos have the background music at a severe minimum. Thanks

    • @Generalpac
      @Generalpac  6 ปีที่แล้ว

      We're also redoing this series with additional info and content!

  • @MegaRonin777
    @MegaRonin777 8 ปีที่แล้ว +1

    Absolutely wrong. I install and test ct's for a living.

    • @Generalpac
      @Generalpac  8 ปีที่แล้ว

      +MegaRonin777, Im no expert but I like to share what I know so others can learn and I get a better understanding in the process. Do you mind sharing what is incorrect? I'd like to investigate and correct my mistake so I don't lead people in the wrong direction. Thanks! Looking forward to your response.

    • @MegaRonin777
      @MegaRonin777 8 ปีที่แล้ว +1

      My apologies, my comment should have been framed in a more positive, constructive manner.
      Rule one, all protective relay ct’s are wound subtractive. I
      have run into an occasional additive auxiliary ct but it is not common. Understanding positive and subtractive is important and in the case of protective relaying it is imperative. With understanding the subtractive rule you can assess the orientation of the ct and how to connect it to your equipment correctly. Of course as an installer, you will thoroughly test the ct to prove its orientation (polarity), saturation and ratio.

    • @Generalpac
      @Generalpac  8 ปีที่แล้ว +1

      hi @MegaRonin777 -- thanks for explaining your comment. I did some research and found that CTs are almost always wound subtractive as you have said. But I couldn't find any specific IEEE standards that confirmed this assessment. There wasn't any relevant material in IEEE Standard C37.110 nor C57.13. Also, to make commenting easier, I created a thread on GPAC Forum with more detail. Please reply here: generalpac.com/forum/index.php?threads/current-transformer-subtractive-polarity.12/ --- Thanks @MegaRonin777 --- looking forward to your response on the forum.

    • @kiamick
      @kiamick 4 ปีที่แล้ว

      @@MegaRonin777 You seem English, Fancy teaching me a thing or 2 about HV protection? Most of the stuff on youtube is in Hindi. At this rate i'm thinking it could be quicker to learn Hindi than it would be to find a decent English teacher who knows CTs etc.

    • @RogerCillion
      @RogerCillion 4 ปีที่แล้ว

      @@MegaRonin777 It is all a matter of reference. Because in the real world the electrons flow in the opposite direction. But that is another subject. I tend to see it as voltage transformer... or better put, the secondary current is a "resisting" current that always travels in the opposite direction. We never create a current, it is the material that is resisting the magnetic field. But you can label it positive or negative, depending on how you install the transformer. Or the angel, better put. Compared to the label of the terminals.