Thanks that was very useful video. I have a bi-directional meter for which L2 and L3 are blinking while L1 is static. In you video your L1 and L2 are blinking while L3 is static. Can you please explain this?
Great video bhai. Nicely explained but there's one mistake. At non-green 3 phase meter, For index 19 & 20, as per ur sheet, OBIS was 1.7.0 & 2.7.0 respectively however on the actual meter for index 19 it was 15.7.0 and there was no index 20 on the meter as after 15.7.0 it went onto index 1 Why is that plz?
Jb mery ghar mn AMI Meter replace hua to replacement k bad jo 1st bill aya us mn both meters ki reading ayi new AMI meter ki reading thk the jabkih old meter ki reading ghalalt the. Bill through sub division office correction hui lekan computer mn abi tak durastagi nai hui. Question is how can be correct my reading in computer jun mn men ne 21 units cosume kiay hn bill record mn 192 unit show ho rhy hn although i have correction papers issued by concernef SDO
Filhal AMI ki reading manual ho rhi ha...aur AMI ki reading ko hi darust maana jaye ga....kuch months tak iski automatic reading ko enable kr dia jaye ga....
My green meter replaced by AMI thsi week. After replacement, import is showing a very high reading while export is showing very low. Please share your expert opinion in this regard.
Kindly ap is bare m kuch kehna chaye g k jo white meter lg re h ye 2000 counts pr aik unit grata h aur iske buraks jo hmare purane digital meters lge we thay wo 3200count pr aik unit grate thay so it means ye jo white meters h ye ultra fast h kindly iska mujhe logical answer zror de gye ga i am waiting?
Brother in some meters it's 3200 imp/kwh and 2400imp/kwh in others. One meters in designed in a way that it will show 1kwh after 3200 impulses and other will show 1 kwh after 2400 impulses. Both of them are accurate but they have different calibration.
AOA, In AMI Meter (Solar Consumer) OBIS code 15.8.0 is used for total Import and export units (combined units) While 1.8.0 for total import and 2.8.0 for total export? Please advise
Excellent sir. One more thing, from where I can get this display list documents for solar 3 phase AMI meter (showing OBIS codes with its explanation)? or you can plz upload and share its link? Many thanks in advance.
Thanks for vedio. Only I want to know solar reading difference with wapda. How many units produced send to wappda and how many taken . What is difference. Codes r too many. Please make it simple.
@@cognitiveacademy6601 Assalam-o-Alaikum sir Hamary meters change huway 3 din hogaye. Mager solar waly jo codes aap ny btaye wo show nae horahy udher. Plzz reply
Bi-directional features AMI single phase aur 3 phase dono me ha...lekin isko enable krwana parta ha...tab hi export ko count kia jaye ga.... Net-metering sirf three phase AMI meters pe allowed ha....
سر مجھے یہ پوچھنا تھا کہ میٹر انسٹال ہونے کے بعد ہمارا ریفرنس نمبر چینج ہو جائے گا یا پرانا نمبر ہی چلے گا کیونکہ ہمارے دو میٹرز ہیں تو ابھی تو بل کا پتا ہمیں چل جاتا کیونکہ ریفرنس نمبر ہمیں معلوم تو نیو میٹر کے ساتھ نیو ریفرنس نمبر ملے گا یا پرانا نمبر چلے گا پلیز جواب ضرور دیجئے گا ✔
The reactive power quadrants in an electric meter are a way to visualize the relationship between active power (P) and reactive power (Q) in a coordinate system. The quadrants help identify the state of the power flow, including inductive, capacitive, lagging, and leading power factors. Here's a breakdown of the four quadrants: *Quadrant 1 (Q1):* - Active power (P) is positive (consumption) - Reactive power (Q) is positive (inductive) - Power factor is lagging (current lags voltage) *Quadrant 2 (Q2):* - Active power (P) is positive (consumption) - Reactive power (Q) is negative (capacitive) - Power factor is leading (current leads voltage) *Quadrant 3 (Q3):* - Active power (P) is negative (generation) - Reactive power (Q) is positive (inductive) - Power factor is lagging (current lags voltage) *Quadrant 4 (Q4):* - Active power (P) is negative (generation) - Reactive power (Q) is negative (capacitive) - Power factor is leading (current leads voltage) By analyzing the quadrants, you can determine: - Whether the load is consuming or generating power (active power) - Whether the load is inductive (e.g., motors) or capacitive (e.g., capacitors) - The power factor, which affects the efficiency of the power transmission and distribution system
is meter ki kio app ha jispar check kar sakty hain reading wagera for import and export. Dosra wapda wala banda bta raha tha kio budgeting be set ho sakti ha ispar, kindly isky bary ma ap agar kio information ha apky pass to vo bta daen.
میرے بھائ۔ کیا ایسا کوئ app موجود ہے جس سے ہم موبائل فون کے ذریعے AMI میٹر کی روزانہ reading لے سکے۔ کسطرح ہم سولر invertor کی لیتے ہیں۔ ہم monthly تو بل down load کرکے لے سکتے ہیں۔ کیا روزانہ wifi پر اس میٹر کی reading دیکھ سکتے ہیں ؟
Behtreen ❤
Thank you so much for your video. This means a lot for us, it is very informative and useful.
Shukria
Perfect information ❤
Shukria
Great video sir thanks alot
JazakAllah.. keep supporting
Please tell me Which OBIS codes are taken for iesco bills, As previous green meters 6,7,8,&9 were taken .
Good explanation❤
Thanks that was very useful video. I have a bi-directional meter for which L2 and L3 are blinking while L1 is static. In you video your L1 and L2 are blinking while L3 is static. Can you please explain this?
Great video bhai. Nicely explained but there's one mistake.
At non-green 3 phase meter, For index 19 & 20, as per ur sheet, OBIS was 1.7.0 & 2.7.0 respectively however on the actual meter for index 19 it was 15.7.0 and there was no index 20 on the meter as after 15.7.0 it went onto index 1
Why is that plz?
What is the OBIS code of instantaneous power consumption in 3 phase plain meter
Jb mery ghar mn AMI Meter replace hua to replacement k bad jo 1st bill aya us mn both meters ki reading ayi new AMI meter ki reading thk the jabkih old meter ki reading ghalalt the. Bill through sub division office correction hui lekan computer mn abi tak durastagi nai hui.
Question is how can be correct my reading in computer jun mn men ne 21 units cosume kiay hn bill record mn 192 unit show ho rhy hn although i have correction papers issued by concernef SDO
Filhal AMI ki reading manual ho rhi ha...aur AMI ki reading ko hi darust maana jaye ga....kuch months tak iski automatic reading ko enable kr dia jaye ga....
My green meter replaced by AMI thsi week. After replacement, import is showing a very high reading while export is showing very low. Please share your expert opinion in this regard.
Did you check your units on the inverter?
Brother is ki calibration JB hogee Tau export set ho jaaingay. Yeh back end se Kuch dino Baad calibrate kr daingay wapda walai
Bhi is meter par net metring be ho jay gee
Kindly ap is bare m kuch kehna chaye g k jo white meter lg re h ye 2000 counts pr aik unit grata h aur iske buraks jo hmare purane digital meters lge we thay wo 3200count pr aik unit grate thay so it means ye jo white meters h ye ultra fast h kindly iska mujhe logical answer zror de gye ga i am waiting?
Brother in some meters it's 3200 imp/kwh and 2400imp/kwh in others. One meters in designed in a way that it will show 1kwh after 3200 impulses and other will show 1 kwh after 2400 impulses. Both of them are accurate but they have different calibration.
So whatabout this meter it is now Set at 2000imp/kWh aur isme 2 times 2000 likha wa h iska Kya mtlb h Kya ye 4000 count p aik unit graye ga?
All these meters are independently manufactured by the third party following all universal standards.
@@cognitiveacademy6601 Ni Ap Meri baat smjhe ni isme 2000 two times likha wa h iska Kya mtlb h?
Wait let me check
Sir Total current export. Es time kita export ho raha ha. Wo kis number pa show krta ha.
AOA, In AMI Meter (Solar Consumer) OBIS code 15.8.0 is used for total Import and export units (combined units) While 1.8.0 for total import and 2.8.0 for total export? Please advise
Dear do u know how to know units consumed in white meter.
@BurkChang th-cam.com/video/hA3a4Kpy2H4/w-d-xo.htmlsi=QkhTaUP3E7AmSgdQ
Thank you so much for the info, For AMI green meter which codes display Instantaneous Import and Instantaneous export?
1.7.0 for instantaneous import
2.7.0 for instantaneous export
@@cognitiveacademy6601 will there be an app for AMI meters? so consumers can check there readings online as well
@@cognitiveacademy6601 Thanks, will there be an app for consumers to check there readings online?
Not yet launched
@@cognitiveacademy6601 Thank you so much 👍🏻
Kitnay units consumed huay hain? How to check
Bhai net metering abhi on nahi hui . Tu kia export zaya ho rhy ha ya wo save ho rahy ha ?
Sir ye jo meter single phase ap nay dikhaya ha is par reading abhi zero ha kiya. Just confirm kr raha hun kay muhay sahi samjh aya ya nahi 2:17
Yes zero ha...
@@cognitiveacademy6601 okay thanks 👍
Excellent sir.
One more thing, from where I can get this display list documents for solar 3 phase AMI meter (showing OBIS codes with its explanation)? or you can plz upload and share its link?
Many thanks in advance.
Thank you so much.
In the last portion i explained solar 3 phase AMI meter...did you watch that?
Yes, but I requested for the documents you were referring to in the video. From where I can get these?
Thanks
I have it...
In the start of third portion i showed it.. take screenshot of that pic please
Otherwise let me know i will share with you
Thanks for vedio. Only I want to know solar reading difference with wapda.
How many units produced send to wappda and how many taken .
What is difference.
Codes r too many. Please make it simple.
I will make a simple video...and will share link with you
2.8.1 for peak export
2.8.2 for off peak export
1.8.1 for peak import
1.8.2 for off peak import
Does Reactive power import has any contribution in net reading.
@@AshfaqMuhammad-kj4pl nope...it is for MDI meters not for domestic green meters....
@@cognitiveacademy6601
Assalam-o-Alaikum sir
Hamary meters change huway 3 din hogaye. Mager solar waly jo codes aap ny btaye wo show nae horahy udher. Plzz reply
installation kay baad reference number aur customer I'd number kya change hu jaey ga
Nhi change hon ge
Loadshedding ho gi
Assalamualaikum
Sir codes ki list kahan sy mil sakti hy. Thanks
Wslam..email dein me send kr deta hun
Bhai iski export programing ho rhi h ya ni
Yes...ho rhi ha...agr apki nhi hui to sub division se enable krwa lein
Jab tak export enable nahi he, tu humain kia apna inverter band rakhyn
Ap connect rkhen...wo export kr rha ha...lekin display pe dikha ni rha...wo jab enable krwa lein ge to dikha bhi de ga
My Ami meter does not show any export units reading
You need to contact sub division office and get it enabled
Ami meter normal bhi ho toh uspe net metering ho jayegi?
3 phase meter tha phle bhi (simple wala green nahi) aur ab bhi 3 phase laga hay new ami wala
Bi-directional features AMI single phase aur 3 phase dono me ha...lekin isko enable krwana parta ha...tab hi export ko count kia jaye ga....
Net-metering sirf three phase AMI meters pe allowed ha....
Yes...iss me feature ha..lekin sub division se enable krwana pre ga..
@@cognitiveacademy6601 ok thanks. Enable krwane k liye kya requirements hen ?
@@alisaim net metering krwani pre gi....
Bhai mew connection ki b bana dyin or ye b bata dyin real fees kitne ha or kitny max conections lg skty hain 1 ghar my..... Begair rishwat wala tariqa
th-cam.com/video/ScLybBE7x_o/w-d-xo.htmlsi=NQNkaL6RQA4MQdse
Ye dekhen
its mean single phase meter pe peek hours nhi hote ?
Yes... exactly
@@cognitiveacademy6601mobile app se units dekhay jasakty hain us app ka kia naam ha
سر مجھے یہ پوچھنا تھا کہ میٹر انسٹال ہونے کے بعد ہمارا ریفرنس نمبر چینج ہو جائے گا یا پرانا نمبر ہی چلے گا کیونکہ ہمارے دو میٹرز ہیں تو ابھی تو بل کا پتا ہمیں چل جاتا کیونکہ ریفرنس نمبر ہمیں معلوم تو نیو میٹر کے ساتھ نیو ریفرنس نمبر ملے گا یا پرانا نمبر چلے گا پلیز جواب ضرور دیجئے گا ✔
Reference no purana hi chly ga..
@@cognitiveacademy6601 thank's a lot 👍
Porana hi rahy ga
Thx for guidance plz.
Three phase ami solar meter mn right lower corner mn jo arrows hain
Woh kya indicate krty hain
Upward
Downwards
Right side + P
Left side. - P
Power consumption quarters
@@cognitiveacademy6601
What is meant by power consumption quarter?
Pl explain
The reactive power quadrants in an electric meter are a way to visualize the relationship between active power (P) and reactive power (Q) in a coordinate system. The quadrants help identify the state of the power flow, including inductive, capacitive, lagging, and leading power factors.
Here's a breakdown of the four quadrants:
*Quadrant 1 (Q1):*
- Active power (P) is positive (consumption)
- Reactive power (Q) is positive (inductive)
- Power factor is lagging (current lags voltage)
*Quadrant 2 (Q2):*
- Active power (P) is positive (consumption)
- Reactive power (Q) is negative (capacitive)
- Power factor is leading (current leads voltage)
*Quadrant 3 (Q3):*
- Active power (P) is negative (generation)
- Reactive power (Q) is positive (inductive)
- Power factor is lagging (current lags voltage)
*Quadrant 4 (Q4):*
- Active power (P) is negative (generation)
- Reactive power (Q) is negative (capacitive)
- Power factor is leading (current leads voltage)
By analyzing the quadrants, you can determine:
- Whether the load is consuming or generating power (active power)
- Whether the load is inductive (e.g., motors) or capacitive (e.g., capacitors)
- The power factor, which affects the efficiency of the power transmission and distribution system
Thanks
@@arshadalisabir7902 welcome brother
آپ اگر میٹر پر صرف سولر انرجی کی گرڈ کو ایکسپورٹ، گرڈ سےامپورٹ کو چیک کرنے کے کوڈ بتا دیں تو مہربانی ہو گی۔
Solar AMI?
Ya simple green meter?
Solar AMI
th-cam.com/video/KnByjUcfY0I/w-d-xo.htmlsi=La498O7sQXXySwjn
th-cam.com/video/KnByjUcfY0I/w-d-xo.htmlsi=La498O7sQXXySwjn
اس میں کیا پری پیڈ سسٹم نہیں ہے 7:53
Filhal nhi ha...lekin aik click se enable kia ja skta ha...
Koi pata Nahi chal Raha koi ashan tarika bata dain
is meter ki kio app ha jispar check kar sakty hain reading wagera for import and export. Dosra wapda wala banda bta raha tha kio budgeting be set ho sakti ha ispar, kindly isky bary ma ap agar kio information ha apky pass to vo bta daen.
Next video insha'Allah
Assalamualaikum
Sir codes ki pdf file send kr sktay hain?
Wslam yes...agr email bhej dein to
میرے بھائ۔
کیا ایسا کوئ app موجود ہے جس سے ہم موبائل فون کے ذریعے AMI میٹر کی روزانہ reading لے سکے۔ کسطرح ہم سولر invertor کی لیتے ہیں۔
ہم monthly تو بل down load کرکے لے سکتے ہیں۔ کیا روزانہ wifi پر اس میٹر کی reading دیکھ سکتے ہیں ؟
Not yet launched but soon you will be able to check readings from IESCO online app....
Yeh khud KO hi bta rha
Sir codes ki pdf ap send kr sktay hain?
Yes
Email address?
Meter mein yai obis codes nahi AA rahay?