@ 2:06 it shows to connect the diode on C and NC, I think the diode goes (parallel) on the negative and positive wire of the mag lock not C and NC. (in reverse, negative (cathode) of the diode to the positive wire)
A maglock can be wired to the LOCK terminal on the LA500s main board. The Lock terminal is on the lower right corner of the board. The positive wire from your maglock would connect to positive on your power transformer, the negative wire from your maglock attaches to C (Common) on the LA500 Lock terminal, and the negative wire from your power transformer attaches to the NC (Normally Closed) on the LA500 Lock terminal. A copy of the LA500 manual can be found at the link below. www.liftmaster.com/catalogresourcesv3/en-us/shared/files/tucmanuals/0136213.pdf
I am not very familiar with this model CE1200LSWR, but think I found a manual online that I have provided a link to the manual below. Looks like if you are using a 12V power supply, the Red/Black wires from your maglock would connect to Positive on your power transformer, the Green/Orange wires from your maglock would connect to C (Common) on the LA500 Lock terminal, and the Negative wire from you power transformer attaches to the NC (Normally Closed) on the LA500 Lock Terminal. If using a 24V power supply, the Black and Green wires from your maglock get twisted together, the Red goes to positive on the power supply, Orange goes to C (Common) on the LA500 Lock terminal, and the Negative wire from your power transformer attaches to the NC (Normally Closed) on the LA500 Lock Terminal. www.allsecurityequipment.com/manuals/1-1200LSWR-manual.pdf For the CS202, Probe; the Red wire from the probe attaches to Positive on your power transformer and Black attaches to Negative on the power transformer. The White and Brown wires from your probe attache to the Exit terminal on the LA500 main board; the White wire to the top side (NO - Normally Open) and Black to the lower side (C - Common). A copy of the CS202, Probe manual can be found at the link below. Wiring can also be found in the LA500 manual. www.emxinc.com/access-control/access-controls-folder/manuals/cs202.pdf
@ 2:06 it shows to connect the diode on C and NC, I think the diode goes (parallel) on the negative and positive wire of the mag lock not C and NC. (in reverse, negative (cathode) of the diode to the positive wire)
Do you have the video wiring mattock to LA500 with external transformer?
How to wire for la500?
A maglock can be wired to the LOCK terminal on the LA500s main board. The Lock terminal is on the lower right corner of the board. The positive wire from your maglock would connect to positive on your power transformer, the negative wire from your maglock attaches to C (Common) on the LA500 Lock terminal, and the negative wire from your power transformer attaches to the NC (Normally Closed) on the LA500 Lock terminal.
A copy of the LA500 manual can be found at the link below.
www.liftmaster.com/catalogresourcesv3/en-us/shared/files/tucmanuals/0136213.pdf
Thanks. My lock is ce1200lswr. Also do you know wiring for probe cs202? Thank you
I am not very familiar with this model CE1200LSWR, but think I found a manual online that I have provided a link to the manual below. Looks like if you are using a 12V power supply, the Red/Black wires from your maglock would connect to Positive on your power transformer, the Green/Orange wires from your maglock would connect to C (Common) on the LA500 Lock terminal, and the Negative wire from you power transformer attaches to the NC (Normally Closed) on the LA500 Lock Terminal.
If using a 24V power supply, the Black and Green wires from your maglock get twisted together, the Red goes to positive on the power supply, Orange goes to C (Common) on the LA500 Lock terminal, and the Negative wire from your power transformer attaches to the NC (Normally Closed) on the LA500 Lock Terminal.
www.allsecurityequipment.com/manuals/1-1200LSWR-manual.pdf
For the CS202, Probe; the Red wire from the probe attaches to Positive on your power transformer and Black attaches to Negative on the power transformer. The White and Brown wires from your probe attache to the Exit terminal on the LA500 main board; the White wire to the top side (NO - Normally Open) and Black to the lower side (C - Common). A copy of the CS202, Probe manual can be found at the link below. Wiring can also be found in the LA500 manual.
www.emxinc.com/access-control/access-controls-folder/manuals/cs202.pdf
@@totalsecuritywarehouse3621 where to connect reed switch to this lock?
I am not sure what a "reed switch" is...