I think you already misaligned the outlet pipe position. You wouldn't had to cut the frame, which has to support quite a lot of weight. By cutting the frame, the strength is compromised.
Cutting frame was imp for 110 mm outlet pipe as outside pipe is of 110 mm only...and no place of reducer wich can be installed der..so company wich provided 90 mm fitting won't be advisable to put there due to lack of space.
Orignal fitting m hi bithadety,frame cut ni krna chye hai,sexnd chyez bhai ye fix krky app plywood ka pec cutting krwalety wo nut s wall p lagadety or usi plywood p tile fix hojata hai ,or jis design ka tile apny yaha fix kia Haina to jitna pec tile ka lagahai wo tile agr 10lgein hai to app same tile lekr rkhlein kioky 5saal m agr kabi apko repaird krna hoto tile Waha s easily remove hoskta hai plywood p,ye apny 1time Wala kaam kia hai
Bhai ji bahut accha video banaya thankyou. Ab ek baat bataiye, Jo concealed flush tank lagaya aapane to Deewar ki chaudai 5 inch honi chahie yah 10 din chahiye jaisa aajkal bund wall banana padta hai lekin aap ne bund wall nahi banaya To uske bare mein please mujhe jawab de dijiye thank you so much
Are bhai yah to bahut fit kar chuke Hain Magar Aisa Bol kaatne ki jarurat nahin padati hai aur frame kaatne ki bhi jarurat nahin padati company Diya usi fitting karo kuch bro easy hai bro fitting karni hai
Total rong hai mane 1000 lagaya hai lekin aesa nhin hai katin kar khi fix hota hai kya pahle kam sikho bad me kam krna nhin malum hai to yha jankari mila jayega plumbing ka koi kam keise hota hai thoda karo magar shahi se
Asan Kam ko aor mushkil kar diye lbow company ka q nahi lagaya jis ki wajah se frem ko katna pada bahot hi galat Kam India men to tumhara Kam hogaya kahin Saudi men hote to injiniar mar kar aap ko bhaga deta
Great Information
That's great bro I'm a plumber from1999
ok uringnal ka high awr out let water suuply and sensur ka dymetion btana
Ek number bro
Good video
Nice
Good work
that place you cover with cement boss, can foam be use instead and gypsum too
Mashaallah
Love from PATNA
Bhai frame ke bina cistern lagta hai kya?
Good information brother 👍
Bhai kitne ka aata hai
Basir bhai aap bhi
Very nice
You are total “master of the plumbing “ 😂😂😂😂😂😂😂😂😂
Good work bro
Nice video keep it up 👍👍👍
Good 👍
Excellent. But if any repairs to be done, it's very difficult to open the wall😃
Repair can be done by just opening switch part. Only there issue comes
I think you already misaligned the outlet pipe position. You wouldn't had to cut the frame, which has to support quite a lot of weight. By cutting the frame, the strength is compromised.
true...
Ture
;:;
right bro
Cutting frame was imp for 110 mm outlet pipe as outside pipe is of 110 mm only...and no place of reducer wich can be installed der..so company wich provided 90 mm fitting won't be advisable to put there due to lack of space.
Nice 👍
Cutting the frame means wrong installation. It can be fixed without cutting the frame. Company don't recommend this type of frame work.👎
Orignal fitting m hi bithadety,frame cut ni krna chye hai,sexnd chyez bhai ye fix krky app plywood ka pec cutting krwalety wo nut s wall p lagadety or usi plywood p tile fix hojata hai ,or jis design ka tile apny yaha fix kia Haina to jitna pec tile ka lagahai wo tile agr 10lgein hai to app same tile lekr rkhlein kioky 5saal m agr kabi apko repaird krna hoto tile Waha s easily remove hoskta hai plywood p,ye apny 1time Wala kaam kia hai
Agr app is PE consider lga date to or acha ho jata agr hme koi in feusher problem ati ha to consiled se hm Pani bnd KR sakte ha
👌👌👌
Bhai haff frem wala lgaya kr phir frem nhi katna ya phir bina frem ka hi lgaya kr
Castmer k pase west kr diye
Good
Not yet specialize this conduit wc need someone l will learn from more😊
Height kya rakhana hy nut ka flooring level se
bhai ji aap se ye puxna tha ki aap ne consider point kaise Diya or kitni consid deni chahiye
👌👌👌👌
Rong fiting hai apaka
@@mdshamshadaalam9287 kya wrong fiting kiya hai?
Flooring level se red colour ka nut height kya hona chahiye
Thanks bhi 🙏🙏
Naic im p k
Bahiya ppr ka krte hue vedio banye
You should never cover the cistern with cement. it should be accessible for repairs.
Bhi total pemish btaye kya kya rakhi hai
Bhai ji bahut accha video banaya thankyou. Ab ek baat bataiye, Jo concealed flush tank lagaya aapane to Deewar ki chaudai 5 inch honi chahie yah 10 din chahiye jaisa aajkal bund wall banana padta hai lekin aap ne bund wall nahi banaya To uske bare mein please mujhe jawab de dijiye thank you so much
Grohe concealed flush tank ka inlet point kitne inchi per hota hai btao plz
Kb diwar chor kr ho bithana thaa...to khaali flush tank q nai bithaya..??? Rack k sath q concilde.?
Bhai udar ek extra 2 pipe hai kya hai oo
Aise ek bathroom ka kitana charge karte hai
Bhai sab napne ka batane ka tarika sahi hai bus lagane ka tarika sahi nahi hai na hi tank saksesh ho ga na stop cock jo lagaye hai aap
❤❤😅
Are bhai yah to bahut fit kar chuke Hain Magar Aisa Bol kaatne ki jarurat nahin padati hai aur frame kaatne ki bhi jarurat nahin padati company Diya usi fitting karo kuch bro easy hai bro fitting karni hai
Bhai reck bolt wali jagha me do ched hota hai AEK 7 inch py AEK 9 inch py usmy kya fark hai kyu ki Mai 7 inch waly me lagaya hu koi dikkat to nhi hai
Bhaiya kuchh jankari lena hai
Lol. Nice guide how not to do it
Magajmari ka nahin bhai sabse aasan kam hai conceal flush tank bitana
شكرا بهاي
Гипсокартон? Не, не слышал)))))
It's not proper way...if we want to construct concealed flush tank bracket, we have to planning as per dimensions, so no difficulty occurs like it....
Volume set kar Pani likhkar repair video
Will Fail if u fitting the chmod
Ap maray lan k ustad ho g ap ko kise chez k pata ha g
Hii
Farim katna ya ap sa suna
Please enquiry whether its wrong or right to cut frame
ভাই,পোলোর তেকে কত সেনটি ওপর রাকতে হবে
cutting the frame and puting tape on the water tank. this can not be more right
Total wast normal Western is best
Total rong hai mane 1000 lagaya hai lekin aesa nhin hai
katin kar khi fix hota hai kya
pahle kam sikho bad me kam krna
nhin malum hai to
yha jankari mila jayega
plumbing ka koi kam
keise hota hai
thoda karo magar shahi se
😅😅😅😅😅
Bhai mai kam karna chahta hu apke sat
Kya bhi Kya Kam kiye ho dekh kar Rona aaraha hai
Mil Sakta ha
Cutting problem not cutting 😮
P
Plice talk in english
Misleading worng procedure don't cut frame ( main loading of wc )
Apko plumbing malomnehi he😂
Tom ko kaam malum nahi hai bhai
Totally wrong bhai sahab Kisi ko galat mat batao company pagal Nahin hai Jo frame banaa kar
😂😂😂😂😂
Rong fitinghs
sare frame ki MC ker di hey u anaarhi
How to do maintenance if you applied cement entire wall, useless plumber😂
Failsh tank tarika sahi nahi hai set kaene ka
Cowboys job. terrible.
Asan Kam ko aor mushkil kar diye lbow company ka q nahi lagaya jis ki wajah se frem ko katna pada bahot hi galat Kam India men to tumhara Kam hogaya kahin Saudi men hote to injiniar mar kar aap ko bhaga deta
Mobail no cahiye hai argent abhi
Frame kata to kata, ye video upload bhi kardiya. 😂
It is a completely wrong procedure, client ko clear kardena tha na ki frame lagana nahi atta.
Thukpati Laga Raha hai 🤣🤣🤣🤣
Are company wale se vichar dikha do
3rd class plumber. berraa gharq kar diya frame ka
Unprofessional work
Full rong work
Sorry but your work isn’t up to the standards!
Ruined the frame by cutting it and not using the company fittings provided in the kit. WORST installation! #grohe #groheindia
If Grohe finds out what you do to their product 😬🫣😳 they will go back to drowning board to correct the design 🤪
Good 👍