Resideo Honeywell home Auto balancing TRV's, unboxing, reviewing, installing and setting up.

แชร์
ฝัง
  • เผยแพร่เมื่อ 6 มิ.ย. 2023
  • Derek in this video unboxes, reviews, installs and sets up the Resideo Honeywell home automatic balancing thermostatic radiator valves and lock shield valves.

ความคิดเห็น • 42

  • @mrcombiBedford
    @mrcombiBedford ปีที่แล้ว

    Always an excellent video
    👍

  • @Kulvinder1974
    @Kulvinder1974 ปีที่แล้ว

    Thanks as always for the interesting video. I’m not an installer or plumber of any description but I find it interesting nevertheless.

  • @Chatterisdotbiz
    @Chatterisdotbiz ปีที่แล้ว

    Thanks for posting this as I'm trying to get the most efficiency out of my system, so very interested in how effective these are at actually balancing a working system in the winter, my first impressions are that they simply reduce the valves 'limit of travel' by a pre-set amount based on a rough calculation of a few parameters, no more technical than a partial turn of the lock-shield valve.
    If the adjustment for balancing was variable based on the systems dynamics, then it could justify being called auto balancing, but I think this products descriptor is a bit of a stretch.

    • @tomkatgastraining
      @tomkatgastraining  ปีที่แล้ว +1

      Part 2 coming soon should help you with your concerns

  • @jockster5525
    @jockster5525 ปีที่แล้ว

    Awesome thanks for your efforts 👍🎉

  • @attilaboruzs1393
    @attilaboruzs1393 ปีที่แล้ว

    Like the video Would be good to know the results after the valves have been fitted. Got a question for you all. I see towel radiators being hung both ways. Who thinks the towel radiator to be hung the other way not meaning sideways but upside down or upside up?

  • @MrRedspanner
    @MrRedspanner ปีที่แล้ว

    Fitted loads of these on a site, I was on. Word of warning the drain off comes open, which i found out when filling the Sales Centre up.

  • @MagicianMan
    @MagicianMan ปีที่แล้ว +1

    I can't seem to find them listed for sale anywhere....... Also is there a 10mm version?
    Didn't Drayton also release an Auto Balancing TRV in 2022?

  • @kevinschoales844
    @kevinschoales844 ปีที่แล้ว +2

    Doesn't Bi-directional mean these TRV's can have the water flow in either direction ?
    I prefer on return as cooler and horizontal for improved air flow.

    • @tomkatgastraining
      @tomkatgastraining  ปีที่แล้ว +1

      You way is the preferred way for me too 👍🏻

  • @colinblythe3710
    @colinblythe3710 ปีที่แล้ว

    What happens if you do nat have a smart phone - can the settings be done on a PC / website or is it just the QR code nonsence ?

  • @julianwebb8712
    @julianwebb8712 ปีที่แล้ว

    And with these is it best to use the fixed or modulating setting on a pump like a Grundfos ups3 ? All that sort of stuff seems a bit of a dark art to me 🤷‍♂️ some content on this would be very useful, thanks 🙏

    • @tomkatgastraining
      @tomkatgastraining  ปีที่แล้ว +1

      Part 2 will be coming once the weather turns colder 👍🏻

    • @julianwebb8712
      @julianwebb8712 ปีที่แล้ว

      @@tomkatgastraining Tomorrow then, thanks 👍😛

    • @tomkatgastraining
      @tomkatgastraining  ปีที่แล้ว

      @@julianwebb8712 😂👍🏻

  • @mrserviceman8795
    @mrserviceman8795 ปีที่แล้ว

    i found this interesting did you just leave lockshgields wide open adjusting only the Trv's

  • @user-fz1zy2kj5j
    @user-fz1zy2kj5j 8 หลายเดือนก่อน

    Hello, is there a video for the result of the experiment? Thanks

    • @tomkatgastraining
      @tomkatgastraining  8 หลายเดือนก่อน

      Not yet but coming soon

    • @user-fz1zy2kj5j
      @user-fz1zy2kj5j 8 หลายเดือนก่อน

      @tomkatgastraining Thanks Derek, look forward to it as I am considering if the balancing TRVs are worth the extra cost.

  • @julianwebb8712
    @julianwebb8712 ปีที่แล้ว

    So, what’s the verdict ?

  • @ElTelBaby
    @ElTelBaby ปีที่แล้ว +1

    Just a ? Could U not fit the TRV (Agreed the numbers would B upside-down) Head at the bottom;... 2 avoid it being knock by a clumb'zy occupant...
    & I've come across a few of them in mi time...

    • @tomkatgastraining
      @tomkatgastraining  ปีที่แล้ว +1

      I have never put one that way I would put them looking up or horizontal but I guess they would still work but it’s something I would never consider doing.

  • @DJ-SPARKY-REACH-ON-AIR
    @DJ-SPARKY-REACH-ON-AIR ปีที่แล้ว +1

    When ur next bathroom update?

  • @mikeread8001
    @mikeread8001 7 หลายเดือนก่อน

    Are you sure that Rad was a multi column?

    • @tomkatgastraining
      @tomkatgastraining  7 หลายเดือนก่อน

      It was just a bit of bad editing I removed me waffling but also took out me explaining it wasn’t a multi column but I was covering all the rads in the app so you are correct it’s not a multi column rad

    • @mikeread8001
      @mikeread8001 7 หลายเดือนก่อน

      Thanks for clarifying, I’ve bought the Honeywell Kombi-TRV V2100 valves, just fitted them, I also observed that you went for 55 inlet temp and 45 outlet, is that a goal in terms cost efficiency? I currently set mine to 70 / 50

    • @tomkatgastraining
      @tomkatgastraining  7 หลายเดือนก่อน

      @@mikeread8001 yes it was 👍🏻

  • @britpackdog4545
    @britpackdog4545 ปีที่แล้ว

    How much they cost?

  • @theplumber4934
    @theplumber4934 ปีที่แล้ว

    Hello Derek The radiators are definitely Steel Panel not Multi column, so maybe recheck what the app says for steel panel type 22 They are also double panel convectors not "Double Double convectors", also the Trv is designed to go on either flow or return that is why they are bi directional, The towel rail is still 600mm high x 1000mm wide as you can't fit a towel rail horizontal because the towels would fall off. This is not your best video Derek

    • @tomkatgastraining
      @tomkatgastraining  ปีที่แล้ว +2

      Thanks for the first part of your comment and I do say that in the video but for the towel rad as you could see in the video it is a horizontal towel rad nor vertical also radiators can be double panel single convectors or double panel double convectors. Sorry you think this is not my best video I will try harder next time

    • @theplumber4934
      @theplumber4934 ปีที่แล้ว

      @@tomkatgastrainingThanks for your prompt reply Derek, I now understand what you mean by "Double Double" as with the whole of our industry it's probably a regional thing, we call it a Double convector (Type 22) or a single convector (type 11) and a type 21 for double with 1 convector. Cheers👍

    • @tomkatgastraining
      @tomkatgastraining  ปีที่แล้ว

      @@theplumber4934 you can’t believe we live in the same country can you 😂 in the video I was trying to show how to use all parts of the app not just the steel panel part I took out the bit where I explained that the rad wasn’t a column one but well done for spotting it 😂

  • @randomcamerajunk6977
    @randomcamerajunk6977 ปีที่แล้ว

    Pro tip. You can't powerflush a system with auto balance TRVs

    • @tomkatgastraining
      @tomkatgastraining  ปีที่แล้ว

      Not even if you set them to 6 and remove the head ?

    • @randomcamerajunk6977
      @randomcamerajunk6977 ปีที่แล้ว

      @@tomkatgastraining yes even 6 will probably have a flow limit - though I don't no for sure on these particular valves. We use imi valves and you do need to remove the insert to flush.

    • @tomkatgastraining
      @tomkatgastraining  ปีที่แล้ว

      @@randomcamerajunk6977 I will ask and find out for the next video 👍🏻

    • @tomkatgastraining
      @tomkatgastraining  ปีที่แล้ว +1

      @@randomcamerajunk6977 just had Honeywell get back to me they say you can power flush on 6 with the head removed they say it has the same resistance as 10mm pipe. Hope that helps.

    • @randomcamerajunk6977
      @randomcamerajunk6977 ปีที่แล้ว

      @@tomkatgastraining awesome. I'll look into them 👍