Defrost Control Boards (Heat Pump Wiring Basics)

แชร์
ฝัง
  • เผยแพร่เมื่อ 5 ก.ค. 2024
  • Universal wiring principles of defrost control boards in heat pump systems.

ความคิดเห็น • 56

  • @ricardojacquez3358
    @ricardojacquez3358 3 วันที่ผ่านมา +1

    Outstanding explanations, Thank you.

  • @paramountHVAC
    @paramountHVAC 5 หลายเดือนก่อน +4

    Great explanation, now everything makes sense after 2 years of being in the field

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  5 หลายเดือนก่อน

      Perfect. Love hearing that.

    • @The1realro
      @The1realro 4 หลายเดือนก่อน

      Isn’t even crazy how we can go so long without knowing something fully lol.

  • @teklesenbetgebreamlak7365
    @teklesenbetgebreamlak7365 3 หลายเดือนก่อน +1

    Incredible knowledge, such brief explanation how heat pump operation works thanks alot

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 หลายเดือนก่อน

      You are most welcome

  • @larryprice6321
    @larryprice6321 3 หลายเดือนก่อน

    Thanks I'm just starting on my a.c journey this is very very helpful for school starts

  • @atleasttry9781
    @atleasttry9781 2 หลายเดือนก่อน +1

    Thanks for sharing your knowledge Mike.

  • @The1JBanks
    @The1JBanks 6 หลายเดือนก่อน +1

    Thank you sir!!! I mainly work on straight AC and needed this.

  • @Eddy63
    @Eddy63 8 หลายเดือนก่อน +2

    Well presented J M ... Thx for your time

  • @toolemanful
    @toolemanful 8 หลายเดือนก่อน +2

    Thank you these videos help me more as a tech

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  8 หลายเดือนก่อน +1

      You're welcome, brother.

  • @user-yf5sg9eg1i
    @user-yf5sg9eg1i หลายเดือนก่อน +1

    Great videos brother!!

  • @Habibthehvacguy
    @Habibthehvacguy 3 หลายเดือนก่อน

    Best video training thanks man

  • @chanseongfoong
    @chanseongfoong 8 หลายเดือนก่อน +2

    Wow! THANK YOU!!!!!

  • @troyfishing4496
    @troyfishing4496 6 หลายเดือนก่อน

    Hi Mike,
    Your videos are really helpful for what I try to install.
    When I renovated my house last year, I installed floor heating(only pvc pipe), but not connected with water heater.
    In order to complete it, I just need thermostat, defrost control board, hot water recirculation pump, 24v/120v relay and 120/24v xfmr.
    Then, R, C, Y connection, right?
    It just needs water pump on/off based on temperature setting.
    Is there any simple kit for this system?

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  5 หลายเดือนก่อน

      Honestly, I'm not familiar with a hot water heater defrost control board radiant heating arrangement to advise on this one.

  • @ernestodiaz76
    @ernestodiaz76 8 หลายเดือนก่อน +1

    Thanks

  • @ananddesai1826
    @ananddesai1826 5 หลายเดือนก่อน

    I liked the explanation.
    I have a question.
    I have a trane unit and every time I turn the heat on even when outside temp is 50 and I raise my house temp from 68 to 69 just one degree the aux heat comes on

    • @The1realro
      @The1realro หลายเดือนก่อน

      Is AUX heat the only heating you have or a secondary heat?

  •  5 หลายเดือนก่อน

    thnk U for the info here. But i have a question. What voltage is on the C terminal, if the R terminal has 24v.?

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  5 หลายเดือนก่อน

      The common just completes any 24v circuit to allow voltage to flow. It shouldn't read anything by itself.

  • @ananddesai1826
    @ananddesai1826 4 หลายเดือนก่อน

    Where would that be inside coils or outside coils?

  • @life.b.s
    @life.b.s 6 หลายเดือนก่อน

    Hey Mike - I'm trying to trace out a low voltage short on my heat pump/hvac system that's blowing my 5amp fuse intermittently and I found that on the Defrost Control Board, I find continuity between Y and O - and I'm unsure if that's normal? Same for R and C. In additional, Y and O also has continuity to Ground. Power to all units were off while I was testing for continuity to find a wire that was contacting ground.

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  6 หลายเดือนก่อน

      Neither Y or O should have continuity to ground or each other. Kind of sounds like the two wires are pinched somewhere and contacting metal. First place I would check is right where the T-stat wire first enters into the condensing unit, or same spot up by the air handler.

    • @life.b.s
      @life.b.s 6 หลายเดือนก่อน

      @@JerseyMikeHVAC Thanks for the quick reply Mike - the continuity between O ad Y happens at the terminal on the Defrost Control Board itself(I disconnected the T-stat wires and tested the prongs on the board and found the continuity) - so I can't tell if the board is bad in this case - however the system still runs just fine except for the intermittent shorts

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  6 หลายเดือนก่อน

      @@life.b.s Where are you getting continuity to ground?

    • @life.b.s
      @life.b.s 5 หลายเดือนก่อน

      ​@@JerseyMikeHVAC Hey Mike! Wanted to follow up back here and thank you for answering my questions above. I might have finally gotten the fix down after hours of chasing down a grounded wire. It seems the main issue was a dead relay on my Defrost Control Board. I had a reddit user call it out but wasn't fully convinced til I noticed that the Fuse would be blown after running for about 90 minutes or so, which was aligned to the defrost cycles, so I figured it must have been something defrost related. Bought a new defrost control board, swapped it out, and it looks like it's been running all night without popping a fuse. Here's to hopping it stays this way.

  • @jasonvalentin
    @jasonvalentin 6 หลายเดือนก่อน

    thank you, you need to make o e of those HVAC for dummies books. I have a question so my Trane TWN024C100A2. runs normally for some time then the fan will stop and not run. board 21C140501G18 - CNT1923 then flashes 3 times, won't go to normal unless breakers reset. my unit has a coil thermostat along the bottom outer edge, connected to coil on control board and the ambient thermostat a little further away, plugged into ambient on the board too, my question is that upon inspection I noticed that the defrost temperature switch THT00811 has two wires they start off blue with white stripes, then turns purple with white stripes, I'm sure its faded over time, but only has one wire connected to the contractor, and the other wire capped off, the control board does not have pins specifically for defrost, I can't find any help.

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  6 หลายเดือนก่อน

      3 flash codes on Trane Defrost board is an indication of low pressure in the system. Have the refrigerant levels been checked lately?

    • @jasonvalentin
      @jasonvalentin 6 หลายเดือนก่อน

      Thank you for the response, I have not, just yet, but now that you bring it up, I’ll be calling someone to check that. Just been doing some maintenance, replaced capacitors and relay, and ran across the discharge line temp switch only having one wire connected to T2 and the other capped off. from the diagrams it shows the sump htr wired to the L1 terminal on the contactor, the other sump wire to one of the wires on temp switch, then the 2nd wire on the temp switch to the T2 on the contactor, what I have is one wire from the temp switch on T2, and the sump htr wires directly connected to L1 and L2 on the contactor. Looks like the switch is bypassed. I saw a photo of the same model heat pump and one of the temp switch wires and the other sump htr wire were wired together

  • @ananddesai1826
    @ananddesai1826 5 หลายเดือนก่อน

    Can you please guide me what could be wrong?
    I opened the unit and saw a DS2 fault light blinking 3 flashes and it looks like low pressure switch open.
    I cycled power and it went away then I tried to turn heat on and same thing happened the aux heat came on right away. This time I didnot see and fault
    I check across the Low pressure switch and it looks closed to me.
    Also when the aux heat was on the compress fan started running aswell.

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  5 หลายเดือนก่อน

      Different models and years have different codes, so I can't really confirm it's a pressure switch issue. It's difficult to narrow it down with so many possibilities and no access to testing.

    • @ananddesai1826
      @ananddesai1826 4 หลายเดือนก่อน

      @@JerseyMikeHVAC so
      I checked the pressures and when in heat mode the pressures looks 60 psi and when I switch to cool the pressure drops to 0 and gets my system in hard lockout.

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  4 หลายเดือนก่อน

      Do you have a filter dryer in the lineset? Maybe internally in the condensing unit? Or could be a bad TXV.
      @@ananddesai1826

  • @garza7676
    @garza7676 5 หลายเดือนก่อน

    Ran into a Nordine heat pump . Defrost board had a M and SW connectors . Wiring diagram didn’t have a legend . Do you know what these are for or mean ?

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  5 หลายเดือนก่อน

      M may be a manual mode option. Not sure about SW but could be a temp switch. Have the model number?

    • @garza7676
      @garza7676 5 หลายเดือนก่อน

      @@JerseyMikeHVAC I have the wiring diagram if you’d like to see it .

    • @garza7676
      @garza7676 5 หลายเดือนก่อน

      Model number Q6E-x48k

    • @garza7676
      @garza7676 5 หลายเดือนก่อน

      Nordyne

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  5 หลายเดือนก่อน

      Had a hard time finding the model number, but I got some info from a manual on another model.
      The SW terminal is the return voltage for the hi/lo pressure switch circuit that the board sends out on the PRESS terminal to prove the circuit.
      The M terminal completes a circuit to activate the compressor contactor off the Y signal, and its purpose to provide some kind of control when connected to an economizer. I don't know exactly in this case what parameter in an economizer would cut power to the contactor, but my first guess is to allow the economizer to shut down the system on a fire damper/smoke detection switch. If there is a molex plug jumper connected to the econ molex plug with a jumper wire between 4 and 6 terminals, this is just a bypass that allows the Y signal to reach the contactor when an economizer is not installed. So basically, either way, power from the thermostat to the contactor runs through that M terminal.

  • @regularguy1140
    @regularguy1140 5 หลายเดือนก่อน

    My heat strips come on instantly, and my heat pump never kicks on. Works fine in cool mode. Any suggestions?

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  5 หลายเดือนก่อน

      Could be a few things, but a stuck reversing valve is not uncommon.

    • @regularguy1140
      @regularguy1140 5 หลายเดือนก่อน

      Turned out to be a bad thermostat.

  • @ananddesai1826
    @ananddesai1826 4 หลายเดือนก่อน

    In your opinion what is the issue?

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  4 หลายเดือนก่อน

      I can't say with certainty without looking at it myself, but based on what you're telling me, I'd strongly suspect a plugged filter dryer.

  • @ananddesai1826
    @ananddesai1826 4 หลายเดือนก่อน

    I have bi direction filter

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  4 หลายเดือนก่อน

      Does the copper line feel like different temperatures on each side of the filter when the system is running?

    • @ananddesai1826
      @ananddesai1826 4 หลายเดือนก่อน

      @@JerseyMikeHVAC yes

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  4 หลายเดือนก่อน

      That may be your issue right there. @@ananddesai1826

    • @ananddesai1826
      @ananddesai1826 4 หลายเดือนก่อน

      We pumped some Freon yesterday
      Than I turned heat on but it’s not very effective.
      Than I turned it on cooling I just went in a hard lock out
      The lockout is when the low pressure switch is triggered a few times

    • @ananddesai1826
      @ananddesai1826 4 หลายเดือนก่อน

      @@JerseyMikeHVAC the TXV?