Flex vs. Metal vs. Duct Board: Differences and Use Cases

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 ก.ย. 2024

ความคิดเห็น • 149

  • @mattp4079
    @mattp4079 ปีที่แล้ว +13

    Det. John McClane taught me everything about the utility and durability of metal ducting. Ever try low-crawling with a .45 and a Bic lighter through fiber board or flex?

  • @RobinBos909
    @RobinBos909 ปีที่แล้ว +11

    I'm a HVAC tech in the Netherlands, we only use solid metal ducting in our installations. I work with one of the few companies who specializes in air heating(/cooling) for residential buildings. Even if we need to cross load bearing beams or so, we make custom conduit in al kind of shapes and sizes. Only when there are no options for solid, we use flex. Never would we use some kind of fiberboard!

  • @danielashton5697
    @danielashton5697 ปีที่แล้ว +16

    As a former HVAC installer, I spent an inordinate amount of time repairing/ replacing duct board and flex duct with metal because they just don’t hold up over time and really adversely affected system performance

    • @Steven-mm7gb
      @Steven-mm7gb 3 หลายเดือนก่อน +1

      They don't mention aluma flex which stands up good unless someone crushes it, but it does suffer from turbulence from its ridges but it is a good alternative to wire flex as it wont degrade from the inside out. But yes rigid is the best

  • @burtfamilyhistory347
    @burtfamilyhistory347 ปีที่แล้ว +5

    Just reducted an 1875 farmhouse, added vents in rooms that were missing and upgraded the return from one 4x6 in the front room to a real return on both floors. Best upgrade ever. Nice to know they’ve used the right products in the right way!

  • @crabkilla
    @crabkilla ปีที่แล้ว +6

    3:15 that is the most beautiful ductwork I have seen installed 🤩

    • @TerryKashat
      @TerryKashat ปีที่แล้ว +1

      Please DON’T ever use Duct Board. Ever. I put some other posts in this thread. You will see my reasoning.

  • @alonzosmith6189
    @alonzosmith6189 ปีที่แล้ว +9

    Learn so much from this channel. I was told to stop finding issues in my house by the wife.

    • @DrMJJr
      @DrMJJr ปีที่แล้ว +2

      That means you’re LEARNING!! 👏🏽👏🏽👏🏽👏🏽

  • @ecospider5
    @ecospider5 ปีที่แล้ว +15

    My house had a lot of flex ducting when it was built. I didn't know this till after I had my ducts cleaned and the cleaners tore multiple of the runs going under the house.

    • @electroluxwash
      @electroluxwash ปีที่แล้ว

      Ouch how it wasn’t too expensive to fix 🙏🏼

    • @ecospider5
      @ecospider5 ปีที่แล้ว +1

      @Electrolux Wash I was able to get to all of them and fix them with tape. I do wonder if that is a hidden problem for the new owners who have been there more than a decade.

  • @DrMJJr
    @DrMJJr ปีที่แล้ว +59

    FOR ME, I’d do metal duct everywhere no matter what; there’s just no substitute for the ability to repeatedly clean them on a regular basis.

    • @hoopie1022
      @hoopie1022 ปีที่แล้ว +2

      Facts

    • @TerryKashat
      @TerryKashat ปีที่แล้ว +2

      100%. The other stuff is not just bad in performance - it’s bad for your health.

    • @MrElemonator
      @MrElemonator ปีที่แล้ว +2

      You need to replace your filter on a regular basis

    • @gregorybergere
      @gregorybergere ปีที่แล้ว +1

      How many ventilation systems are designed for cleaning? I gues none with flexible trunking.

    • @dannym1772
      @dannym1772 ปีที่แล้ว +2

      I actually just got my air ducts cleaned and did not know this. My air ducts were really old and now they completely broke them all over the place. I have to do a full replacement now since i had non-metal ducts and the cleaning company ruined them.

  • @Tom-pc7lb
    @Tom-pc7lb ปีที่แล้ว +13

    Always get your ducts in a row.

  • @bquedenfeld
    @bquedenfeld ปีที่แล้ว +13

    43 yrs. in the HVAC business I delt with a 3 and more I would never ever use duct board in my home it's not allowed in Hospital and Schools so why should anyone want that in their home.

    • @TerryKashat
      @TerryKashat ปีที่แล้ว +4

      I didn’t know it wasn’t allowed in Hospitals & Schools but that simply backs up my HIGH scolding of this product.
      Shouldn’t be on the market.

  • @Anthony.Delagarza
    @Anthony.Delagarza ปีที่แล้ว +5

    When he said you guys know what to do, who else yelled out, “Oooooon the build show!”

  • @Rocco101
    @Rocco101 ปีที่แล้ว +24

    Metal duct all the way , seal all seams really really well and it will last a lifetime time.
    Great video Matt
    Appreciate you

    • @buildshow
      @buildshow  ปีที่แล้ว +4

      Right on. Totally agree

    • @TerryKashat
      @TerryKashat ปีที่แล้ว +4

      100% Metal duct all the way.
      The cheaper options should not even be available for something as important as our air.

    • @jakubsebor4756
      @jakubsebor4756 ปีที่แล้ว

      @@buildshow that's why you used pvc duct hose in your house. Do you remember the Zehnder system?

    • @lukemarks9132
      @lukemarks9132 ปีที่แล้ว

      @@jakubsebor4756 what’s wrong with the zehnder ducts

  • @1stWorldProblemsSolved
    @1stWorldProblemsSolved ปีที่แล้ว +10

    Good to know my older all metal ducts are still the best option.

    • @MrElemonator
      @MrElemonator ปีที่แล้ว

      Also good to know metal is great at transferring heat so there is a energy factor where the heat might take longer with metal ducts.

  • @boby115
    @boby115 ปีที่แล้ว +12

    In my neck of the woods (St Louis metropolitan area) well over 90% of the homes are built with basements, sheet metal ductwork was always used and continues to be used to this day. Sized, supported and installed correctly sheet-metal ductwork can withstand the test of time with few problems. The problem I’m starting to see is the lack of skilled tradesmen in this field, the Legacy sheet metal men are starting to retire and die off (I am seeing less pants legs and cheeked or rounded corners used , i’m assuming the contractors don’t want to pay for the extra time or have the expertise).

    • @goobygoober455
      @goobygoober455 ปีที่แล้ว +2

      Over here in Lancaster County, PA and surrounding areas we mainly use fiberglass ductboard instead of metal. Not many of the guys know how to do metal anymore

  • @hoopie1022
    @hoopie1022 ปีที่แล้ว +42

    Duct board has no use case for being a duct. Exterior insulation sure, a duct that airflow goes through absolutely not. Way too much fiber shedding and I’ve seen way too many home owners have respiratory issues when duct board is in the home.

    • @lrc87290
      @lrc87290 ปีที่แล้ว +3

      I think you are talking about the old duct board with the raw fiberglass on the inside. Our 35 yr. old condo community I help manage has this horrible stuff. It is disgusting after 35 years and honest duct cleaning companies won't clean it. The board they are showing has a coating of some kind.

    • @hoopie1022
      @hoopie1022 ปีที่แล้ว +2

      @@lrc87290 The newer duct board does has a black liner on it which I agree is a million times better but it also starts to breakdown over time but this system they have built with the Dehus is also pretty advanced so in this VERY RARE case it might work out okay.

    • @compasteedee
      @compasteedee ปีที่แล้ว +8

      I agree with this 100%. It is a horrible product, even in its current iteration. It is a disposable product in a permanent application. There are plenty of other problems, such as combustion and fire conduction, and any one of them should be enough to have it outright banned. In Canada there are no building codes that allow it, from the largest producer of pulp and fiber in the world; that should tell you something.

    • @brettbret8836
      @brettbret8836 ปีที่แล้ว +1

      As a wellness expert who specializes in environmental toxins i can tell you that duct board is going to contaminate the air with toxic materials.

    • @TerryKashat
      @TerryKashat ปีที่แล้ว +3

      I can personally vouch for this.
      An office building I used to work in - I noticed I had respiratory challenges when I spent too much time there. Wouldn’t clear until a full day or two of not being there.
      After I did my own inspection - duct board everywhere.

  • @CoconutPalmPictures
    @CoconutPalmPictures 11 หลายเดือนก่อน +6

    I was waiting to hear about insulating metal ducts but never heard anything. How is that accomplished in an un-AC attic or crawlspace?

    • @paulmryglod4802
      @paulmryglod4802 24 วันที่ผ่านมา

      Duct board over metal plenum, and they make insulation blanket for round metal duct of all sizes

  • @MrStreaty122
    @MrStreaty122 ปีที่แล้ว +12

    I thought it was best practice to use solid metal ducts for the majority of runs, and then flex for the last 5-10 ft if absolutely necessary

    • @goobygoober455
      @goobygoober455 ปีที่แล้ว

      I think code is 14 feet max for flex

  • @ddivinia
    @ddivinia ปีที่แล้ว +3

    How about noise concerns. Sound thru the ducts from room to room. Metal ducts has got to be louder. In that conditioned space - what is your target humidity level? Love the show, D.

  • @larryseibold4287
    @larryseibold4287 ปีที่แล้ว +2

    An end to end metal duct is loud compared to flex duct or duct board, so there is a trade off beyond cost, even if oversized a bit.

  • @jaxchristian6408
    @jaxchristian6408 9 หลายเดือนก่อน +2

    Flex duct most common because easiest and cheapest to install. Easy to crush crawling around in the attic

  • @quacktony
    @quacktony ปีที่แล้ว +6

    I never knew duct board could be use to make ducts. The insulation properties were there but I assumed stainless steel pipes or flex duct was used. Good to know

  • @EOTE_TX
    @EOTE_TX ปีที่แล้ว +4

    I am building a custom home with a gambrel roof. I decided to custom build my ducts out of 1" aluminized insulation board in a triangular shape fitting to the lower section of the lower gambrel of the roof. The duct is compact, and was easy to build and install. I taped it together with aluminum tape and zip tape. I also created the inlet and outlet plenums out of the same materials. I used 6" flexible duct to provide air to the registers from the second floor to the main floor ceilings. Since the home is in an "L" shape I used 12" flexible ducts between the floor trusses to transfer air between ducts on both sides of the gambrel roof. The temperature difference between different parts of the home only varies about 1/2 of a degree from day to day. Then again, because the roof is 6-1/2" PolyIso on the exterior and 6" of fiberglass batt insulation on the inside and the walls are 3-1/2" PolyIso on the outside and 6" of fiberglass batt on the inside the house varies only 1/2 degree from day to day. Coupled with an HVAC system and dehumidifier the duct work performs flawlessly. The amount of insulation ensures that the house temperature does not change significantly and the load on the HVAC system is negligible. We had a night where the temperature dropped to 9 dgrees Fahrenheit and we purposely turned off the HVAC unit overnight for 12 hours. The inside temperature only dropped 3 degrees. This is a 3800 sq. foot home with 2 floors and only a 5 ton HVAC system. I call it my big Yeti!

    • @imtheonevanhalen1557
      @imtheonevanhalen1557 ปีที่แล้ว

      In my area R-8 duct board is required.....2 inch. I used R-8 duct board for the 20' plenum, and came off with 6 inch flex duct. Works very well and passed inspection with no problem.

  • @1agaragedoorssacramento
    @1agaragedoorssacramento ปีที่แล้ว

    Great video Matt!

  • @gerwynsamuel
    @gerwynsamuel ปีที่แล้ว +2

    Matt, how do mini-ducts in a high velocity small duct system compare?

  • @Smallduckenergy
    @Smallduckenergy ปีที่แล้ว

    Good job inacho

  • @juligrlee556
    @juligrlee556 ปีที่แล้ว +4

    Does anybody know the physics of sizing metal ducts to best guide heat from the furnace to the extreme other end of a series of rooms at distance from the source? Discussion of products without proper location and sizing is at least as important as materials. Also, what options you use to insulate your metal pipes has a lot to do with efficiency, especially when the furnace is downwind of prevailing winds outside winds or thermal issues in walls. Everyone believes they are the perfect duct system designers although they know little about volume of moving air inside of the ducts themselves. Additionally, where to place furnace outflow to rooms and where to place cold return is the field of HVAC designers for each room. There is a lot to know in planning your HVAC ductwork and very few qualified HVAC flow designers capable of providing even heat to a 3 BD house with large living quarters, entertainment centers, office space, play room etc.

    • @kellyhutson8988
      @kellyhutson8988 ปีที่แล้ว

      Good point, that's why engineers make the medium bucks.

    • @terrencesauve
      @terrencesauve ปีที่แล้ว +2

      That's why we use hydronic heating and mini split a/c. Theres so much head loss moving air through joist space that it doesn't make sense anymore. We used to only have hydronics half a century ago, why not go back to systems that still works 50 years later. All these shitty lined cardboard will have to be ripped out in 20 yrs.

  • @georgek.5817
    @georgek.5817 ปีที่แล้ว +4

    Higher quality products always cost less long term

  • @MultiYlin
    @MultiYlin ปีที่แล้ว +10

    a quick question: I see Germans begin to use rigid plastic for duct work.

    • @Abdullah34610
      @Abdullah34610 ปีที่แล้ว +1

      My initial concern would be warping when hot. Also how porous/vulnerable to mold it is. Probably depends a lot on the material.

  • @Jameson4327
    @Jameson4327 ปีที่แล้ว +3

    You haven’t put out a video on cleaning ductwork. I just cleaned my house and I was shocked at the amount of dirt,hair? whatever.

    • @hoopie1022
      @hoopie1022 ปีที่แล้ว

      th-cam.com/video/bWCr66fX_k4/w-d-xo.html

  • @michaelshettig7805
    @michaelshettig7805 ปีที่แล้ว +6

    If you're building a million-dollar house, I would get an upgrade alternate price on metal ductwork and see if it fits into your budget.

    • @terrencesauve
      @terrencesauve ปีที่แล้ว +1

      Well that the main problem with new homes. Many pick the kitchen upgrade or the third bathroom over insulation and better HVAC. You only want to pay for what you see, not what comes out of your pocket every month...

    • @hotrodpaully1
      @hotrodpaully1 ปีที่แล้ว +1

      If you're building a $1000 dollar house I still would use metal

  • @patora911
    @patora911 ปีที่แล้ว +8

    I need the breakdown of how easy these are for ninjas to crawl through…

    • @TerryKashat
      @TerryKashat ปีที่แล้ว +1

      I was concerned about Solid Snake - but you make a good point too 😂

    • @redneckgoatfarmer
      @redneckgoatfarmer ปีที่แล้ว +2

      Sheet metal duct is the only ninja approved duct. Due to higher cost sheet metal ducts are utilizing thinner metal which can bare less weight and it is noticeable noisier. Making it much harder on ninja.

  • @xslabcabxhearsex
    @xslabcabxhearsex ปีที่แล้ว +4

    I have been doing HVAC/sheet metal mechanic for over 33 years.if you can invest in a custom metal duct system done by a reputable professional company.it will cost more but worth it.

  • @lesliehatun2044
    @lesliehatun2044 3 หลายเดือนก่อน

    My concern is noise at the vent, intake. With increased capacity flowing thru a flex is probably quietier?

  • @townsendliving9750
    @townsendliving9750 ปีที่แล้ว +1

    Hydronic heat and cooling, per room home runs to cassette systems. Each room can be temperature controlled, can be installed by the most rookie DIY homeowner, easy to clean and maintain.

  • @oldschool6798
    @oldschool6798 ปีที่แล้ว

    Good, to the point program. Thanks much.

  • @Average_Middle_Aged_American
    @Average_Middle_Aged_American 29 วันที่ผ่านมา

    What is a reasonable price for new duct work?
    10 runs (10ft - 30ft each).
    2000 square feet ranch, single story, AC in attic center of the home.

  • @erhvacramirez8023
    @erhvacramirez8023 ปีที่แล้ว

    For me the better way always is BUILD system or combination between metal round and flex !

  • @DonTruman
    @DonTruman ปีที่แล้ว

    How do you clean ducts? I presume you have to pull it apart, then run some sort of brush-vacuum through it.

  • @Steven-mm7gb
    @Steven-mm7gb 3 หลายเดือนก่อน

    Surprised they did not mention aluma flex which I would say is one step below sheet metal hard pipe, yes it does crush easy but it wont degrade over time in the inside like wire flex , and will last just as long as hard pipe if not molested by someone crushing it. And yes, it does have ridges so some turbulence.

  • @hoopie1022
    @hoopie1022 ปีที่แล้ว +2

    And you can clean flex duct as long it’s not brittle.
    You can clean and incapsulate lined ductwork or duct board according to the IICRC and NADCA standards per the NADCA ACR 2013

  • @tullgutten
    @tullgutten ปีที่แล้ว +3

    Flex should be illegal for any closed space like in wall or attic as it is garbage for air flow, it collects dust innside that leads to mould and is impossible to clean after some years without destroying and need to replace it all (it is really a 5 to 10 year max product before replacement is needed/reccomend.
    Steel is great for everything except working with it as it takes more time but as long as it doesn't get water on it it is a 100 year product that only needs inspect/clean for dust now and then and it is easy clean, will not get damadged from cleaning at all, fire resistant (still a fire hazard if flames get into it without any fire dampener) it is silent since it is smooth and heavy.
    The foam board one i haven't seen before but it should have many of the same benefits as metall just not nearly as easy to clean

    • @tullgutten
      @tullgutten ปีที่แล้ว

      As a homeowner and doing full renovation on my house im going for steel duct in and out to my HRV with aluminium semi flex expandable duct the last meter for long bends and it is also a "lifetime" product.
      Half meter flex out from the HRV to give easy access for cleaning and it all being in a "closet" for easy access to replace only used for noise reduction.
      Then steel and possibly semi flex Aluminium the rest.
      Still making it so not done. but i am limiting plastic flex only to 1 meter to and from the HRV since it is some thin flimsy shit only for vibration free connection.
      Also going to hang the HRV on acoustical spring hangers to isolate vibration from the house frame (not any noticeable vibration tho as it is not the rotating ceramic core type

  • @joshuaellison01
    @joshuaellison01 ปีที่แล้ว

    We are searching for a solution to our in slab duct repair issue. There appears to be areas which are deteriorating and the spray encapsulation, like Duct Armor, seems like a good solution. Anyone have experience or feedback on this method? Replacing what's in the slab does not appear to be an option, neither is installing split units or overhead duct work.

  • @danielstoscup755
    @danielstoscup755 ปีที่แล้ว +1

    Hey guys I have a 30 year old house with metal ducting and I hear it creak and pop every time my furnace kicks on and off. I assume it’s from the metal expanding and contracting, any advise for how I can fix it?

    • @hoopie1022
      @hoopie1022 ปีที่แล้ว +1

      Sometimes you can find the spot that pops and just stuff foam or insulation around that area to keep it tight…I know that’s a gangster recommendation but it’s the easy cheap option. If you want the expensive option get new duct that is thicker metal.

  • @Regnarrussell
    @Regnarrussell ปีที่แล้ว +2

    My home has duct board and flex duct. It’s horrible and I will swap it out for metal. I may even spray foam the surface to insulate.

  • @andrewnaber520
    @andrewnaber520 ปีที่แล้ว

    Hey Matt, you ever see or come across Alumaflex? Thoughts on that?

  • @TerryKashat
    @TerryKashat ปีที่แล้ว +11

    Matt - I highly suggest you highly advise against Duct Board and advise against Flex Duct.
    These things are cheap and cause respiratory issues due to the fiber glass insulation entering your space.
    Additionally - the porous nature of Duct Board allows for moisture build up and mold. Go look at any installation and you WILL FIND MOLD on the Duct Board and that gets injected into your air.
    I speak from personal experience.
    It should have never made it to market.

    • @terrencesauve
      @terrencesauve ปีที่แล้ว +3

      These are great points. Carrying out or moving moist air with lined cardboard is just a terrible idea.

    • @goobygoober455
      @goobygoober455 ปีที่แล้ว

      Fiberglass duct is pretty resistant to moisture unless you pour water on it when installing or leave it in the rain

    • @TerryKashat
      @TerryKashat ปีที่แล้ว

      @@goobygoober455 and when there is a leak in the cieling? Or major humidity challenge in the building. Game over - both things happen and it is hard to detect once installled.

  • @smokeydabeecharlescoleman8365
    @smokeydabeecharlescoleman8365 หลายเดือนก่อน

    Which one is better to fight condensation ?

    • @thursdaythought7201
      @thursdaythought7201 หลายเดือนก่อน

      Ideally you shouldn't be putting any of them in a non-conditioned space so condensation wouldn't be an issue.
      If you have to put it in unconditioned space, sheet metal will always be better.

  • @globaldemise
    @globaldemise 2 หลายเดือนก่อน

    I’m am IEP. Metal ductwork only. It’s the only choice for good indoor air quality and can be cleaned when a bad contractor installs a cheap leaky filter box

  • @pleasenomore100
    @pleasenomore100 ปีที่แล้ว

    I'm having a new home built, and I'm afraid that my HVAC contractor is going to pencil whip the DALT test on my ductwork.
    How to I keep my HVAC contractor honest with duct air leakage testing (DALT), it is energy conservation code in NC. I'm certified through AABC and performed numerous DALT tests in a commercial setting using equipment from Retrotec and Oriflow.

  • @williammauzy7918
    @williammauzy7918 ปีที่แล้ว +3

    Metal duct work everywhere, sprayed with foam. Only way to go.

    • @TerryKashat
      @TerryKashat ปีที่แล้ว

      100% Metal Duct. I would advise against the foam and use sealing tape. It’s healthier from a biological standpoint.

    • @audreye7078
      @audreye7078 ปีที่แล้ว +1

      @@TerryKashat insulation?

    • @TerryKashat
      @TerryKashat ปีที่แล้ว

      @@audreye7078 the foam is not biologically healthy from a chemical standpoint.
      Insulation is technically fine - the challenge wise that is you want NO fiberglass insulation exposed to the air leaks or interior of your duct do that the fiberglass never gets in the duct pathway.

  • @loctobert9421
    @loctobert9421 ปีที่แล้ว +1

    Love that "Tesla" has become equivalent to "High-end" or "Great quality".

    • @turbo3922
      @turbo3922 ปีที่แล้ว +2

      Yeah that doesn't make a lot of sense to me. There are plenty of other cars that are better known for build quality and high cost. Tesla has a reputation for poor quality control (big panel gaps, misaligned parts, etc).

    • @02au17
      @02au17 ปีที่แล้ว

      ​@@turbo3922true but non car people probably dont know that

  • @Loadrunner620
    @Loadrunner620 ปีที่แล้ว +1

    Flex duct always installed incorrectly 60% inefficient.
    Fixed metal duck is the best.
    Avoid ninety-degree turns elbows. Use a slight curve elbow. Insulate around the metal

  • @Casmige
    @Casmige 9 หลายเดือนก่อน

    Wow!, Nacho certainly has his ducts in order…!

  • @1oldbluesheepdog
    @1oldbluesheepdog ปีที่แล้ว

    Is the metal ductwork insulated or does it have to be in a controlled space?

    • @kellyhutson8988
      @kellyhutson8988 ปีที่แล้ว +1

      It comes uninsulated but can be wrapped in insulation if used in an unconditioned space. You just have to check the insulation type and specs for the space you're using it in and make sure it's installed correctly.

  • @kenreynolds1000
    @kenreynolds1000 ปีที่แล้ว +1

    Corrugated pipe kills flow. Anyone who has studied head loss will tell you round and smooth is best. Sharp corners are bad too. Hard to do and mostly overcome with more horsepower.

  • @frankminisplitking
    @frankminisplitking ปีที่แล้ว +3

    Wouldn’t it be cool, no pun intended, if there was an in-between board and sheet metal… I think as systems get more efficient and complicated… why haven’t we come up with something better? An “in between” would be awesome, as more people care about the “lungs of their house” and their investment. Obviously it would be great if we can use the same tools we already use for duct board… but a smoother, more resistant finish on the interior… maybe a neoprene layer, call it duct board pro…

    • @tonycosta2455
      @tonycosta2455 ปีที่แล้ว +1

      Double wall metal ductwork. Very expensive but, you get an inner liner of metal a inner layer of insulation then an outer metal layer.

    • @frankminisplitking
      @frankminisplitking ปีที่แล้ว +1

      @@tonycosta2455 I’m sure that’s more awesomeness, but looking to offer an in-between metal and duct board for the budget minded. I saw someone post about plastic something from Germany, sounds interesting… hopefully we can use the same tools!

    • @1hiphopnow
      @1hiphopnow ปีที่แล้ว

      Even if there were the experts would advise against it cuz it’s not 100% 🤷🏼‍♂️

  • @wendellsatterwhite50
    @wendellsatterwhite50 ปีที่แล้ว +4

    Why couldn't you use PVC?

    • @mitchdenner9743
      @mitchdenner9743 ปีที่แล้ว

      You could if your independently wealthy.

    • @stephen7938
      @stephen7938 ปีที่แล้ว +1

      Static charge build up, possible fire hazard.

    • @shannabolser9428
      @shannabolser9428 ปีที่แล้ว

      I've seen it used for underground system

    • @wendellsatterwhite50
      @wendellsatterwhite50 ปีที่แล้ว

      Didn't Matt have a show where it was used in an underground system in a house in Colorado?

  • @Ed-jg3ud
    @Ed-jg3ud ปีที่แล้ว

    Is it me or is the audio on this seem weird and kinda off? Like they re-recorded after the fact and dubbed it in?

  • @gordonlee5761
    @gordonlee5761 ปีที่แล้ว

    I use rigid galvanized steel for most parts of my ductwork. I only use duct board for return air and registers, connecting with 7ft long flex ducts for noise control. I have a MERV13 media filter and a whole house dehumidifier system so I don’t think it gonna cause IAQ issues.

  • @dsdragoon
    @dsdragoon ปีที่แล้ว

    The best ducts are the ones running throughan air condition attic space.

  • @concreteguyjd
    @concreteguyjd ปีที่แล้ว

    What, no FRP ducts?

  • @1galste
    @1galste 9 หลายเดือนก่อน

    after several test of air flow the amount of gain of metal is not justified by the higher cost. Also with time the metal duct became noisier. Last consideration is that if you put a piece of flex along a metal built system the efficiency people is talking about is really less, even using a short amount o flex. Metal is better but it is not all gold as they say.

  • @moabfool
    @moabfool ปีที่แล้ว +1

    The loss of velocity alone is a good reason to never do flex. Metal or don't bother.

  • @macoveialex6823
    @macoveialex6823 ปีที่แล้ว

    What about HDPE?

  • @gregorybergere
    @gregorybergere ปีที่แล้ว

    It is worrying how much of a new house is made up of complex chemicals, especially plastics in many forms. Do we know what is slowly leaching out over the years into these tightly sealed boxes? We usually only find out after people get sick.

    • @cosmicallyderived
      @cosmicallyderived ปีที่แล้ว

      There’s an air exchanger Matt likes to have installed. Fascinating devices that balance pressure and cycle air. Air still comes in but heat and cold is dealt with and particulates too.

  • @duanehundley
    @duanehundley ปีที่แล้ว +1

    Which one is the quietest?

    • @winkel08
      @winkel08 ปีที่แล้ว +1

      Using flex is the quietest I would only use duct board if necessary given you live close to the ocean and concerned with the main duct rusting out otherwise use metal for main duct and flex going to vents if you use all metal it's a good bit noisier you can do 3 to 5 foot of flex and the rest metal going to the vent

    • @hoopie1022
      @hoopie1022 ปีที่แล้ว

      I think lined metal is quieter than anything but duct board is pretty quiet

    • @kenreynolds1000
      @kenreynolds1000 ปีที่แล้ว

      Anything to decouple a solid pipe vibration to the vent. That’s why they use a short section of flex.

    • @winkel08
      @winkel08 ปีที่แล้ว +3

      That may be true but I don't care for lined metal bc of the fibers in the insulation their is a reason hospitals don't allow lined metal or duct board in their facilities

    • @WastedBuff
      @WastedBuff ปีที่แล้ว +1

      @@winkel08 Just added a note for my builder to do exactly this based on your comment. Thanks!

  • @nathanmrudd
    @nathanmrudd ปีที่แล้ว +1

    Good content, but I demand more than 5mn. 😂

  • @TinyGiraffes
    @TinyGiraffes ปีที่แล้ว +1

    Their Mic's sound off. I've heard Matt enough to know the higher parts of his voice aren't getting recorded. (It's happening on all of them; so I doubt it's intentional.)

  • @louiem4134
    @louiem4134 ปีที่แล้ว

    One of the first few to see as soon as it posted noice.

  • @winkel08
    @winkel08 ปีที่แล้ว +3

    I would strongly discourage the use of duct board due to poor air quality

    • @lrc87290
      @lrc87290 ปีที่แล้ว

      See my answer above

  • @virgil3241
    @virgil3241 ปีที่แล้ว +2

    New builders using flex duct should be sued and then banned from building. Cheap and fast is the only reason they do it, and then charge a normal price or more anyway. Should be banned from building, since they probably hide it as well from home owners that dont know any better

  • @1hiphopnow
    @1hiphopnow ปีที่แล้ว

    So duct board and flex is useless ✍🏻 steel it is

  • @tjrooger1092
    @tjrooger1092 ปีที่แล้ว +5

    This is all a bit misleading. When a HVAC system is installed, there's a duct flow calculation done. It doesn't matter what the % reduction is. The ducts would be upsized if the loss was significant enough to matter. Like you'd use a 7" flex instead of a 6" metal. The double the cost must just be for materials only. The labor alone is probably 5 times. Flex duct can be a 20+ foot run without worrying about seams.

  • @ridiculous_renovations
    @ridiculous_renovations ปีที่แล้ว +3

    Duct board where it's appropriate for only a 20% bump in price of the ductwork seems like a no-brainer.

  • @edwardlucero9665
    @edwardlucero9665 ปีที่แล้ว

    😂 only if this were a real message. You notice it is a message recording, not even sleepy Joe would leave a voicemail.😂

  • @oatlord
    @oatlord ปีที่แล้ว +1

    "Equates" or rather "e-queets"

  • @TerryKashat
    @TerryKashat ปีที่แล้ว +1

    Flex Duct and even worse Duct Board have NO BUSINESS being used. They should be banned - taken off the market. It’s so cheap and so BAD for you in any application. I speak from personal experience on Duct Board.
    Nobody is ever going to replace them once installed.

  • @harryschrysan3183
    @harryschrysan3183 2 หลายเดือนก่อน

    Lmao I am doing hvac for 6 years and first time I hear duct board usage instead of actual SHEET METAL ductwork. Sometimes running ductwork is fucking tough but I would take that anyday compare to that fiberglass shit stuffing my nose and skin. Who the hell uses duct board and call themselves professionals??