ความคิดเห็น • 32

  • @15vatsaljoshi42
    @15vatsaljoshi42 3 ปีที่แล้ว +2

    Superb 👍sidhi bat no bakwas.... directly to the point...I am so impressed the way you explain...sir aese hi video banate rahiyega

  • @gazalisameer2226
    @gazalisameer2226 11 หลายเดือนก่อน +1

    At last shear wall should be designed right?

  • @bhavypandya3252
    @bhavypandya3252 3 ปีที่แล้ว +1

    Where is the stairs?
    Please make short video for stairs for this structure. Just show on ground level

  • @omararab1304
    @omararab1304 3 ปีที่แล้ว +1

    Good vedeo. Thank you for sharing

  • @jayganesh7167
    @jayganesh7167 5 หลายเดือนก่อน +1

    You made mistake in Defining seismic load . You only added x and z where is -x and -z

    • @civilengineeringbyshravan9596
      @civilengineeringbyshravan9596  5 หลายเดือนก่อน

      here am assuming only +X and +Z direction

    • @jayganesh7167
      @jayganesh7167 5 หลายเดือนก่อน

      @@civilengineeringbyshravan9596 sorry bro. I saw many videos. Seismic loads acting in only x and z direction only not negative side. And also searched in chat gtp. Wind load only acts in 4 sides, seismic in 2sides

  • @chan20678
    @chan20678 9 หลายเดือนก่อน

    For the balcony in a building what will be the process. Like loads and all... Etc..

  • @vamsirajana3436
    @vamsirajana3436 3 ปีที่แล้ว +2

    Dear Sir, what ever the result we are getting in staadpro we cannot execute blindly. Kindly let us know the method how we can make possible execution(in real time) of reinforcement detailing by considering staad results

  • @davidocampo6504
    @davidocampo6504 10 หลายเดือนก่อน

    THANKS. WHAT ABOUT THE DIAFRAM RIGID?

  • @srinivasr6136
    @srinivasr6136 3 ปีที่แล้ว

    Add anaylsis of pounding effect in etabs

  • @venkateswarishunmugam
    @venkateswarishunmugam 3 ปีที่แล้ว

    sir i have doubt. live load is not properly assigned , what i want to do sir and other doubt while giving beam and column property depth value want to given in YD but you are giving in ZD.

  • @Krishnadewani-r74
    @Krishnadewani-r74 3 ปีที่แล้ว +1

    Sir the bmd n deflection are not showing properly like it's only visible when I super zoom it . What should I do?

  • @vipulvekaria2955
    @vipulvekaria2955 3 ปีที่แล้ว

    What foundation settlement limit you considered for building design

  • @akshayrawat2930
    @akshayrawat2930 3 ปีที่แล้ว +1

    hello, I am facing L/d is less than 2.5 warning in my project due to which it says deep beam cannot be designed how I can avoid this warning in my case and also while designing shear wall for lift portion it says failed: slenderness limit exceeds the maximum limit. please sir help

  • @Curiosity-1992
    @Curiosity-1992 3 หลายเดือนก่อน

    Loads are not applied correctly
    seismic loads are not applied correctly

  • @liakatali4063
    @liakatali4063 3 ปีที่แล้ว

    may i know your pc configuration please.

  • @sanjaysingh-sm7ib
    @sanjaysingh-sm7ib 3 ปีที่แล้ว +1

    How to connect with your for business enquiry ?

  • @aazadalfaaz4697
    @aazadalfaaz4697 3 ปีที่แล้ว

    SIR,
    ERROR : NO SURFACE INCIDENCE HAS BEEN PROVIDED YET.
    RESULTS WHY SIR?
    HOW TO RESOLVE PROBLM. PLS EXPLAIN SIR pls

  • @sandeeppetwal8952
    @sandeeppetwal8952 3 ปีที่แล้ว

    Dead load of slab is applied wrongly.

  • @gadhirajunarendravarma7449
    @gadhirajunarendravarma7449 3 ปีที่แล้ว

    Hi bro
    I my staad pro top view bottom views command deleted. can u help me.

  • @sandhiyag4379
    @sandhiyag4379 3 ปีที่แล้ว

    Sir can you upload the autocad file

  • @ajeettiwari7869
    @ajeettiwari7869 2 ปีที่แล้ว

    Please Provide the autocad file