How to Remove (Recover) Refrigerant From a Running AC System

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ต.ค. 2024

ความคิดเห็น • 59

  • @kennyjohnson4411
    @kennyjohnson4411 3 ปีที่แล้ว +10

    Yes, another amazing video from HVAC school. I love this channel ❤

    • @activia1967
      @activia1967 3 ปีที่แล้ว +1

      Srahello

    • @paulrozinski1488
      @paulrozinski1488 3 ปีที่แล้ว +1

      Another great video. Love the live graphics👍

  • @resurgensix
    @resurgensix 3 ปีที่แล้ว +9

    WOW these new vids Bryan is producing are ready for prime time! I can watch them again and again to imprint these processes.

  • @RonNL1030
    @RonNL1030 3 ปีที่แล้ว +4

    This turned out to be very practical to me. I’ve been in that situation before. Now I know an easy and effective way to do it. Thank you.

  • @hvacdoc
    @hvacdoc 3 ปีที่แล้ว +12

    What application are you using to make these videos? They come out awesome every time!

  • @elgringoec
    @elgringoec 3 ปีที่แล้ว +4

    Great thorough explanation of the process, while being quick and concise! The animation detail is nothing short of amazing too, perfectly matched to and illustrative of the information content. Really gotta hand it to you, it's professional grade production.
    And I can definitely perform this operation much more quickly and efficiently after reviewing this.
    👍😁✌️🏖️

  • @michaelstaley9979
    @michaelstaley9979 3 ปีที่แล้ว +2

    Great video. Just finished watching videos similar to this on ac service tech channel. Keep up the good work.

  • @Northfigy
    @Northfigy 3 ปีที่แล้ว +2

    I just discover the HVAC school app !! Wow thank you! And thank you for your vidéos this is helping me a lot at school and in my summer Time job !!
    Great job !!

  • @davejohnsonnola7908
    @davejohnsonnola7908 3 ปีที่แล้ว +2

    Great info and presentation.
    I would vote for lingering a bit longer on the more salient points that may be passed over by our short attention spans.

  • @falleruen
    @falleruen 4 หลายเดือนก่อน

    I watch 5 other videos and this was the best one

  • @ilovenythismuchilovenewyor5801
    @ilovenythismuchilovenewyor5801 3 ปีที่แล้ว +1

    video tutorials like this are great. huge help thanks

  • @acrepairnearme
    @acrepairnearme 3 ปีที่แล้ว

    Great illustration

  • @FabricioValdez-si1pk
    @FabricioValdez-si1pk 5 หลายเดือนก่อน

    Amazing video. Thanks for sharing HVAC school. Saludos from Wisconsin.

  • @rcinfla9017
    @rcinfla9017 ปีที่แล้ว

    Many scroll compressor AC units have a low side suction line cutout switch for low suction pressure. It may not allow a compressor operated recovery below a low side suction pressure of about 55 psi. This still gets most of the refrigerant recovered.
    If it is the first time you encounter this, it might scare you when the compressor shuts down making you think you damaged compressor. Don't worry it is just the low pressure cutout switch doing its job. You might want to stop at about 60 psi suction pressure to prevent the cutout switch activation.

  • @roberthaggerty5720
    @roberthaggerty5720 3 ปีที่แล้ว

    Another 6 minutes of great knowledge Thx.

  • @dxboy1513
    @dxboy1513 3 ปีที่แล้ว

    Top Notch 👌🏼 great demonstration as always

  • @1984juant
    @1984juant 3 ปีที่แล้ว +1

    Great video.

  • @daniellundquest8252
    @daniellundquest8252 3 หลายเดือนก่อน

    Hook up a ball valve on your core deppressor. Close the valve and the high pressure refrigerant will go into the tank and clear your hoses… dependent on the temp of the refrigerant, ambient temp, and the temp of the cylinder

  • @Oz_is_on_fire
    @Oz_is_on_fire 3 ปีที่แล้ว

    You guys are awesome! Uppin’ my game with every view.

  • @TheDirtyd863
    @TheDirtyd863 3 ปีที่แล้ว

    Awesome video thanks Brian.

  • @Wdbx831
    @Wdbx831 3 ปีที่แล้ว +1

    Top quality education - who knows, maybe they will be eligible for continuing education credits.

  • @hubercats
    @hubercats 3 ปีที่แล้ว

    Great video!

  • @kevinjeudy5607
    @kevinjeudy5607 3 ปีที่แล้ว

    Great videos. Very helpful.

  • @nation1280
    @nation1280 3 ปีที่แล้ว

    Good information, amazing video

  • @esaumel
    @esaumel 3 ปีที่แล้ว +1

    Amazing

  • @alohadoc1
    @alohadoc1 2 หลายเดือนก่อน

    How would this be done with a mini split? I need to remove some overcharge

  • @OcRefrig
    @OcRefrig 3 ปีที่แล้ว

    Wow, Very cool Graphics ! Very Well done. 👍
    If u don’t my mind me asking , What Program are u using to do a Video like that ?

  • @kennethlobo4420
    @kennethlobo4420 3 ปีที่แล้ว

    Thank u so much .Great video

  • @centinelarefrigeracion8834
    @centinelarefrigeracion8834 3 ปีที่แล้ว

    Hi , thanks for share this

  • @mikecasey7505
    @mikecasey7505 3 ปีที่แล้ว

    What software is this?? This is amazing stuff for training!

  • @valeriesmith4642
    @valeriesmith4642 ปีที่แล้ว

    Hi, How long does it take to remove the freon tso one can repair the unit?

  • @MemeKing44
    @MemeKing44 2 ปีที่แล้ว

    When you recover the second time and refrigerant is still in tank do you repeat the same process, by first vaking down? Or do you not vak because you already have a vak? And can putting a vak on a tank with refrigerant mess something up? Seems like the vak pump would pull refrigerant toward it into the vak pump and empty your tank I to the vak pump is this wrong?

  • @vincenzolabarbera8964
    @vincenzolabarbera8964 3 ปีที่แล้ว

    Is this the same process for a small window air condition? I have a 10,000 BTU window air condition and would like to remove the Freon

  • @jamalbadhafari2634
    @jamalbadhafari2634 3 ปีที่แล้ว

    🥰👍

  • @michaelcostello6991
    @michaelcostello6991 2 ปีที่แล้ว

    Do all small split units have access to suction and liquid lines with hoses ?

  • @davidkarpen5686
    @davidkarpen5686 3 ปีที่แล้ว +1

    While doing this. What prevents oil from leaving the system as well? And would that damage the compressor because if the correct oil was added from the factory and an imbecile overcharged it, if oil came out with the excess refrigerant, the system would now be low on oil? Correct?

    • @lebenitj
      @lebenitj 3 ปีที่แล้ว

      5 grams is not an issue..

  • @anthonybarragan1687
    @anthonybarragan1687 2 หลายเดือนก่อน

    And if there is refrigerant in the tank, can you still use this method?

  • @xXRAWRXx5
    @xXRAWRXx5 2 ปีที่แล้ว

    I’m in school for this and just learning so excuse me for asking a dumb question but if this was a liquid recovery, at the end you said open the hand valves to allow the remaining refrigerant back into the suction side. How is this possible to return refrigerant in liquid form to the suction side?

    • @thecurious6721
      @thecurious6721 2 ปีที่แล้ว

      Open slowly and let the liquid to vaporize and scroll compressors handle liquid better than reciprocating compressors, there are no valves to break.

  • @ericsplicer
    @ericsplicer 3 ปีที่แล้ว

    Nice

  • @hassanabdulrahman1691
    @hassanabdulrahman1691 3 ปีที่แล้ว

    Hi I have questions
    Dose this cylinder consider as dangerous goods how can I get the MSDS as I would like to import it to middle east
    Thanks

  • @Thanos-ic8ki
    @Thanos-ic8ki 2 ปีที่แล้ว

    will this also work with r22 ? ?

  • @mrgreen9086
    @mrgreen9086 3 ปีที่แล้ว

    I've noticed that alot of these models feature a txv, are pistons no longer being made or phased out?

    • @joelescalante2616
      @joelescalante2616 3 ปีที่แล้ว +2

      depends on the region you are in Florida it seems like everything has TXV now. I am in NC and I see pistons everyday even on brand new systems.

    • @mrgreen9086
      @mrgreen9086 3 ปีที่แล้ว

      @@joelescalante2616 that makes sense thanks

  • @Homestead_Adjacent
    @Homestead_Adjacent 3 ปีที่แล้ว +1

    How does pulling to a vacuum harm the compressor?

    • @davejohnsonnola7908
      @davejohnsonnola7908 3 ปีที่แล้ว

      Many scroll compressors are set up to "disengage" the scrolls below a certain pressure. Not made to pull system into vacuum the way older style reciprocal can.

    • @Homestead_Adjacent
      @Homestead_Adjacent 3 ปีที่แล้ว

      @@davejohnsonnola7908 there is a clutch? My mind is gravy.

    • @davejohnsonnola7908
      @davejohnsonnola7908 3 ปีที่แล้ว

      @@Homestead_Adjacent more like a mechanism that separates the scrolls and bypassing the gas

    • @mojo9288
      @mojo9288 3 ปีที่แล้ว +2

      There are several ways a compressor can be damaged when it is in vacuum. Compressors are cooled internally by the returning refrigerant vapor from the evaporator as well as externally by the air being drawn/blown over the compressor from the condenser fan. Without that cooling a compressor will overheat and the motor windings may be damaged.
      The refrigerant vapor and oil within a compressor act as electrical insulators. When in vacuum, the compressor does not have that insulation and an arc may occur inside the compressor and cause a condition called terminal venting. The compressor electrical terminals may blow out or the insulators around the terminals will be damaged and cause a leak.
      Most compressors will handle running in vacuum for short periods but they cannot operate in a vaccum for extended periods. You will see in some literature that warn never start a compressor when it is in vacuum. Low pressure controls will shut off a compressor before it goes into vacuum but not all systems utilize them.

  • @scottm3552
    @scottm3552 3 ปีที่แล้ว

    What app did you use for refrigerant bottle weight?

    • @HVACS
      @HVACS  3 ปีที่แล้ว

      Hvac school app

  • @devintrusdell5733
    @devintrusdell5733 ปีที่แล้ว

    GOD loves you so much that HE gave HIS SON to die for our sins on the cross and HE rose from the dead again after three days john 3:16 ( paraphrased )and have a blessed day and JESUS loves you 😇🥰🙏🏿🙏🏾🙏🏽🙏🏼🙏🏻🙏👼🏿👼🏾👼🏽👼🏼👼🏻👼

    • @w8what575
      @w8what575 4 หลายเดือนก่อน

      Thou shalt not have any other gods before me! Yet here we are spreading this around pushing people to worship the man said to be god incarnate …let’s stop worshipping the man and remember who it was …God the father the creator who is not Jesus

  • @jaymz0074
    @jaymz0074 3 ปีที่แล้ว

    Awesome video