KUKA krc4 TIA portal v16 tutorial AUTO ext with profinet 4K

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 ก.ค. 2024
  • 4K #Tutorial - Learn how to configure KRC4 automatic external on kuka workvisual 6.0 using profinet bus communication with and TIA portal v16
    Aprenda a configurar kuka KRC4 automático externo mediante el protocolo industrial profinet con workvisual 6.0 y TIA portal v16
    Apprenez à configurer l'automatique externe sur kuka profinet KRC4 avec workvisual 6.0 et TIA portal v16
    Erfahren Sie, wie Sie KRC4 automatisch extern auf kuka workvisual 6.0 mit Profinet-Buskommunikation mit und TIA Portal v16 konfigurieren
    了解如何使用 profinet 工业协议与 workvisual 6.0 和 TIA 门户 v16 配置外部自动 kuka KRC4
    kuka krc4 TIA portalı v16 öğretici profinet 4K ile AUTO ext
    -------------------------------------------------------------------------------------------------------------------------------------------------------
    In this video, we show how to connect a kuka KRC4 KR10R1100 with a siemens PLC 1510SP F-1 PN through profinet. You will learn, how to change the IP address, how to use workvisual and modify kuka projects, how to map inputs and outputs and how to start a kuka robot as a slave with a plc as a master through automatic external configuration.
    Video in 4K.
    -------------------------------------------------------------------------------------------------------------------------------------------------------
    Video chapters:
    -------------------------------------------------------------------------------------------------------------------------------------------------------
    00:00 - Intro
    00:14 - 1.1 Configure IP address kuka KRC4
    00:27 - 1.2 Configure IP address local computer
    00:55 - 2.0 Open workvisual project from controller and configure
    01:22 - 2.1 Add profinet to the bus structure
    01:39 - 2.2 Configure profinet stack
    02:01 - 2.3 Mapping kuka workvisual IOs
    03:03 - 3.0 Upload project to controller
    03:23 - 4.0 Import kuka profinet slave device GSD into TIA portal
    04:35 - 5.0 Add the PLC and kuka device
    04:58 - 6.0 Change profinet names and IP addresses
    05:37 - 7.0 Replace IO stack in the kuka profinet device
    05:53 - 8.0 Upload project
    06:27 - 9.0 Add the variables to the PLC
    06:38 - 9.1 Configure the automatic external in KUKA
    08:00 - 10. Start cell program and follow the sequence diagram
    (Sequence diagram described on the top left corner)
    -------------------------------------------------------------------------------------------------------------------------------------------------------
    ============================================================================
    To know more about us follow/Para saber más síguenos en:
    - Web: rebots.tk/
    - LinkedIn: / rebots
    - Instagram: / rebots.tk
    - Facebook: / rebots.tk
    Partner:
    - Website: www.eurobots.net/
    - LinkedIn: / robots-industriales
    - IG: / eurobots.it
    - FB: / eurobots
    #PLC #KUKA
    4K ROBOTS INDUSTRY40 AUTOMATION DEVELOPMENT INNOVATION RESEARCH INDUSTRIAL IOT
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 49

  • @WTEENG
    @WTEENG 2 ปีที่แล้ว +3

    Thank you for sharing such a wonderful resource. It was very helpful for the project.

    • @rebots
      @rebots  2 ปีที่แล้ว

      You're very welcome! Glad it was helpful.

  • @mikelopal
    @mikelopal 2 ปีที่แล้ว +2

    Es un buen video, bien explicado, gracias

    • @rebots
      @rebots  2 ปีที่แล้ว

      Muchas gracias

  • @Nickesley
    @Nickesley 2 ปีที่แล้ว +4

    un millon de gracias!! me ahorraste muchas horas de frustracion! :)

    • @rebots
      @rebots  2 ปีที่แล้ว

      Gracias a ti, de eso se trata. Me alegro mucho de que te haya sido útil.

    • @manuellopez-cc4wi
      @manuellopez-cc4wi 2 ปีที่แล้ว

      @@rebots jajaj gracias!

    • @manuellopez-cc4wi
      @manuellopez-cc4wi 2 ปีที่แล้ว

      @@rebots estas cosas pueden llegar a ser un sufrimiento que muchas veces no porta nada.

  • @yacinesafsaf9902
    @yacinesafsaf9902 2 ปีที่แล้ว +2

    Thx it was cet helpful

    • @rebots
      @rebots  2 ปีที่แล้ว +1

      No problem

  • @otabektillavayev3309
    @otabektillavayev3309 ปีที่แล้ว +1

    Thanks million

    • @rebots
      @rebots  ปีที่แล้ว

      Thank you for watching!

  • @onurdurmus7880
    @onurdurmus7880 2 ปีที่แล้ว

    Hello, thanks for your excellent tutorial, it helps me a lot ! I hava a question, how can i get integer or real values from Siemens plc to KR C4? I do not want to do signal declerations, i want to get salt integer or real value. Does it possible ?

    • @rebots
      @rebots  2 ปีที่แล้ว

      Hi thank you for your comment, well without declaring the variable in kuka you can call the corresponding input mapped to those Siemens values in the Krc4.

  • @youssefaboumalik9083
    @youssefaboumalik9083 ปีที่แล้ว

    thank you for your effort ..your videos are great i have a question if you could help me plz i want to add variable that can control speed of spindle throw a siemens 1200 i add analog output model in siemens plc but i couldn't find how to link the output analog to kuka krc4 robot

    • @rebots
      @rebots  ปีที่แล้ว

      Thank you very much, it's quite the same instead of declaring digital inputs you add an analog input that has to be a integer value in the profinet stack.
      Following this video, on the left where i have digital IO select analogue and on the right where the fieldbuses are select profinet. Then select the type of uint or int and link them togther. That's it.

  • @marcol5374
    @marcol5374 2 ปีที่แล้ว +1

    Thanks for the video ! Which are the variable to set on from Plc to make kuka ready to works ?
    Where i can found docs?

    • @rebots
      @rebots  2 ปีที่แล้ว +3

      The variables are the ones highlited in bold (black) in the top left corner in the google docs.
      You can see me force the variables in TIA Portal 8:10
      MOVE_ENABLE -> DRIVES_OFF -> PERI_RDY-> DRIVES_ON->CONF_MESS, EXT_START,->PGNO (program number) and check the parity PGNO_PARITY -> PGNO_VALID
      Here is a link to the doc docs.google.com/document/d/1f2L0BV68-yikwlLvt19IvcquR1-vm6lMRr1h-kgdZpE/edit?usp=sharing

    • @marcol5374
      @marcol5374 2 ปีที่แล้ว +1

      @rebots thanks a lot. I think that if you can make a video with some ladder logic in Tia that tipically techinician uses to talk with kuka (an Fb or Fc for example with phases of work for example ready, mode, error, all ok so drive on, load job....etc...) would be a great experience. Of course sharing the project ! What do you think?

    • @rebots
      @rebots  2 ปีที่แล้ว +1

      @@marcol5374 Yes we will do in that in the near future, we will automate ours with a function block and show the sequence diagram as a circuit with gates. There are many things we need to do and other robots we have to program. But definitely that will be another of our videos.
      Until then I hope you like the next videos and keep following us. Thank you for your interest.

    • @marcol5374
      @marcol5374 2 ปีที่แล้ว

      @@rebots thanks a lot. We are waiting for :-)

    • @rebots
      @rebots  2 ปีที่แล้ว +1

      @@marcol5374 Don't worry, we will cover this topic soon!

  • @sebastiansillsten9915
    @sebastiansillsten9915 2 ปีที่แล้ว

    Hi, can you do this same with Officelite? (virtual machine). I want to connect Officelite to Beckhoff PLC (read and write values) and Beckhoff PLC to KUKASIm via beckhoff ads.

    • @rebots
      @rebots  2 ปีที่แล้ว +1

      Sadly we do not have Officelite or a Beckhoff PLC. But we would like to do this in the future.

  • @michaelduessel8965
    @michaelduessel8965 ปีที่แล้ว

    How do you display the smart on the screen? Is this the KUKA.virtualremotependant?

    • @rebots
      @rebots  ปีที่แล้ว

      Hi, watch our other video on how to do it th-cam.com/video/4pO9Pvz3nBQ/w-d-xo.html

  • @mikelopal
    @mikelopal 2 ปีที่แล้ว

    Ya lo encontre en Workvisual, puedo hacer lo mismo en el Tia Portal?

    • @rebots
      @rebots  2 ปีที่แล้ว

      Sí, puedes exportar el GSD de workvisual

  • @HZ-yw4cb
    @HZ-yw4cb ปีที่แล้ว

    hello, I'm a student who is doing my thesis with Tia Kontrol KUKA with mxAutomation. there is always a problem with the configuration, KRC_Major, Minor, and Revision are not matched to PLC_Major, minor, and Revision(the numbers are 3 2 2 3 2 0), and ErrorID is 414. could you please tell me what should I do so that I could solve this problem? thank you very much for the answer

    • @rebots
      @rebots  ปีที่แล้ว

      Hi sorry but we haven't used mxAutomation so I'm not familiar with the programming and I'm even more lost with the error codes.
      Good luck!

  • @williamhuang5329
    @williamhuang5329 2 ปีที่แล้ว

    Hanzhen harmonic drive gear , strain wave reducer, robot joint, over 30 years experience

    • @rebots
      @rebots  2 ปีที่แล้ว

      OK we will check it out

  • @javieralejandromarinisea9085
    @javieralejandromarinisea9085 2 ปีที่แล้ว

    Donde puedo consegui el archivo GSDML de KRC4?

    • @rebots
      @rebots  2 ปีที่แล้ว +1

      th-cam.com/video/eg6vnXBNJWo/w-d-xo.html
      Puedes encontrar el archivo en la carpeta donde descargaste el workvisual.
      Workvisual/devicedescriptions/gsdml
      Sí no has descargado workvisual puedes conseguirlo en la página oficial
      kuka.sharefile.eu/d-s0977718741844ab8

  • @mikelopal
    @mikelopal 2 ปีที่แล้ว

    no encuentro el GSD para el S7 1200, como lo puedo tener porfa. gracias

    • @rebots
      @rebots  2 ปีที่แล้ว

      En la página de siemens si no puedes actualizar el catálogo.

  • @user-uj5pk1iy2q
    @user-uj5pk1iy2q 2 ปีที่แล้ว

    how to connect HMI Siemens TP700 to KUKA robot?

    • @rebots
      @rebots  2 ปีที่แล้ว +2

      Add the HMI -> Simatic comfort panel -> 7" Display -> add your device. Then make sure the profinet name and IP address are correct like with the PLC in the video and you will have both connected.

  • @mikelopal
    @mikelopal 2 ปีที่แล้ว

    tengo el s7 1200 es que necesito el GSD file?

    • @rebots
      @rebots  2 ปีที่แล้ว

      Debería estar en el catálogo de Siemens, sino actualiza el catálogo o busca en la página de siemens el modelo que tengas

  • @kurthansen391
    @kurthansen391 ปีที่แล้ว

    I'm confused you did all this in "T1" mode. Shouldn't it be in "Ext" mode?

    • @rebots
      @rebots  ปีที่แล้ว

      Im not really using the smartpad much in this video, only to show how to change the IP and connect.
      The whole point of this video is to start a program in AUTO Ext mode with a PLC.
      You need to be on "EXT" mode when I am forcing the outputs of the PLC in the minute 08:00

  • @josepablomarin8988
    @josepablomarin8988 ปีที่แล้ว

    Se puede usar un poco 1200?

    • @rebots
      @rebots  ปีที่แล้ว

      Sí claro, se puede usar cualquier plc

  • @davidperezchaves7542
    @davidperezchaves7542 10 หลายเดือนก่อน

    Good content, but extremly fast explained!!! Sometimes is quite difficult to follow the explainations.

    • @rebots
      @rebots  9 หลายเดือนก่อน

      Sorry for that, yeah I got a couple of feedback from the viewers, I will try to make slower tutorials. When i created them I thought it could be slowed down and paused. But I will make slower videos in the future

  • @EPLSS
    @EPLSS ปีที่แล้ว

    hello sir thanks for the videos can i contact you please i have few question about communication with kuka on ethercat

    • @rebots
      @rebots  ปีที่แล้ว +1

      Yes contact me on the websites email. At rebots.tk

    • @EPLSS
      @EPLSS ปีที่แล้ว

      @@rebots thanks for responding is done already sent you