LG Power Board Muitl Gender JIG Diagram (PN: RAD33187801) Power Board Muitl Gender JIG Diagnostic model List Existing 12Y, 13Y, 14Y, 15Y LED models included 15Y, 16Y, 17Y - 18Y OLED, 16 -17 -18 Y LED model Power diagnosis function newly added 15Y -16Y -17Y -18Y OLED Model, 16Y -17Y - 18Y LED Model Power Board Muitl Gender How to Connect Power Board Muitl Gender JIG Power BD Smart Jig Voltage Switch 13.2V or 18V > 24V Smart Jig Voltage Setting Note on setup The correct power diagnosis can be made only if it is set correctly. 24V Power Board : Change the switch to 24V of Smart Jig Voltage 20V Power Board : Change the switch to 24V of Smart Jig Voltage 13.2V or 18V Power Board : Change the switch to 24V of Smart Jig Voltage. 15Y OLED (EG96,EF95,EG92,EG93,EG94) Power Board Diagnostic method (1) Check power board voltage * Switch the product SW in JIG to LCD. LCD MODEL Check the power voltage and switch (24V) to the correct voltage. Fix the LCD MODEL switch to 24V.(Smart JIG) Disconnect the Main Board 24Pin Power Cable connector. Connect the 24Pin Power Cable connector to the Muitl Gender JIG 24Pin connector Power Board Diagnostic method (2) When the OK LED (24V,12V) turns on, Power Board is normal. When the NG LED turns on, the Power Board can be judged as defective. 16Y OLED (B6) Power Board Diagnostic method Connect the 24Pin Power Cable connector to the Multi gender JIG 24Pin connector. Switch the LCD MODEL S/W to 24V by checking the power voltage. Fix the LCD MODEL switch to 24V.(Smart JIG) When the OK LED (24V,12V) turns on, Power Board is normal. When the NG LED turns on, the Power Board can be judged as defective. 16Y OLED (C6) Power Board Diagnostic method Check power board voltage. Smart JIG: Fix the LCD MODEL switch to 24V.(Smart JIG) Disconnect the Main Board 24Pin Power Cable connector. Connect the 24Pin Power Cable connector to the Muitl Gender JIG 24Pin connector When the OK LED (24V,12V) turns on, Power Board is normal. 6Y OLED (E6) Power Board Diagnostic method Check power board voltage. Fix the LCD MODEL switch to 24V. (Smart JIG) Disconnect the Main Board 24Pin Power Cable connector. Connect the 24Pin Power Cable connector to the Muitl Gender JIG 24Pin connector When the OK LED (24V,12V) turns on, Power Board is normal. When the NG LED turns on, the Power Board can be judged as defective. 16Y OLED (G6) Power Board Diagnostic method Check power board voltage. Fix the LCD MODEL switch to 24V.(Smart JIG) Disconnect the Main Board 24Pin Power Cable connector. Connect the 24Pin Power Cable connector to the Muitl Gender JIG 24Pin connector When the OK LED (24V,12V) turns on, Power Board is normal. When the NG LED turns on, the Power Board can be judged as defective. 17Y OLED (B7-C7-E7-G7) Power Board Diagnostic method Disconnect the Main Board 28Pin Power Cable connector. Connect the 28Pin Power Cable connector to the Muitl Gender JIG 28Pin connector. Switch the LCD MODEL SW to 20V by checking the power voltage. Fix the LCD MODEL switch to 20V.(Smart JIG) When the OK LED (24V,12V) turns on, Power Board is normal. When the NG LED turns on, the Power Board can be judged as defective 17Y OLED (W7) Power Board Diagnostic method Disconnect the Main Board 24Pin Power Cable connector. Connect the 24Pin Power Cable connector to the Muitl Gender JIG 28Pin connector Switch the LCD MODEL SW to 20V by checking the power voltage. Fix the LCD MODEL switch to 20V.(Smart JIG) When the OK LED (24V,12V) turns on, Power Board is normal. When the NG LED turns on, the Power Board can be judged as defective.
LG Power Board Muitl Gender JIG Diagram (PN: RAD33187801)
Power Board Muitl Gender JIG Diagnostic model List
Existing 12Y, 13Y, 14Y, 15Y LED models included
15Y, 16Y, 17Y - 18Y OLED, 16 -17 -18 Y LED model Power diagnosis function newly added
15Y -16Y -17Y -18Y OLED Model, 16Y -17Y - 18Y LED Model
Power Board Muitl Gender How to Connect
Power Board Muitl Gender JIG
Power BD Smart Jig Voltage Switch
13.2V or 18V > 24V
Smart Jig Voltage Setting
Note on setup
The correct power diagnosis can be made only if it is set correctly.
24V Power Board : Change the switch to 24V of Smart Jig Voltage
20V Power Board : Change the switch to 24V of Smart Jig Voltage
13.2V or 18V Power Board : Change the switch to 24V of Smart Jig Voltage.
15Y OLED (EG96,EF95,EG92,EG93,EG94) Power Board Diagnostic method (1)
Check power board voltage
* Switch the product SW in JIG to LCD.
LCD MODEL Check the power voltage and switch (24V) to the correct voltage.
Fix the LCD MODEL switch to 24V.(Smart JIG)
Disconnect the Main Board 24Pin Power Cable connector.
Connect the 24Pin Power Cable connector to the Muitl Gender JIG 24Pin connector
Power Board Diagnostic method (2)
When the OK LED (24V,12V) turns on, Power Board is normal.
When the NG LED turns on, the Power Board can be judged as defective.
16Y OLED (B6) Power Board Diagnostic method
Connect the 24Pin Power Cable connector to the Multi gender JIG 24Pin connector.
Switch the LCD MODEL S/W to 24V by checking the power voltage.
Fix the LCD MODEL switch to 24V.(Smart JIG)
When the OK LED (24V,12V) turns on, Power Board is normal.
When the NG LED turns on, the Power Board can be judged as defective.
16Y OLED (C6) Power Board Diagnostic method
Check power board voltage.
Smart JIG: Fix the LCD MODEL switch to 24V.(Smart JIG)
Disconnect the Main Board 24Pin Power Cable connector.
Connect the 24Pin Power Cable connector to the Muitl Gender JIG 24Pin connector
When the OK LED (24V,12V) turns on, Power Board is normal.
6Y OLED (E6) Power Board Diagnostic method
Check power board voltage.
Fix the LCD MODEL switch to 24V. (Smart JIG)
Disconnect the Main Board 24Pin Power Cable connector.
Connect the 24Pin Power Cable connector to the Muitl Gender JIG 24Pin connector
When the OK LED (24V,12V) turns on, Power Board is normal.
When the NG LED turns on, the Power Board can be judged as defective.
16Y OLED (G6) Power Board Diagnostic method
Check power board voltage.
Fix the LCD MODEL switch to 24V.(Smart JIG)
Disconnect the Main Board 24Pin Power Cable connector.
Connect the 24Pin Power Cable connector to the Muitl Gender JIG 24Pin connector
When the OK LED (24V,12V) turns on, Power Board is normal.
When the NG LED turns on, the Power Board can be judged as defective.
17Y OLED (B7-C7-E7-G7) Power Board Diagnostic method
Disconnect the Main Board 28Pin Power Cable connector.
Connect the 28Pin Power Cable connector to the Muitl Gender JIG 28Pin connector.
Switch the LCD MODEL SW to 20V by checking the power voltage.
Fix the LCD MODEL switch to 20V.(Smart JIG)
When the OK LED (24V,12V) turns on, Power Board is normal.
When the NG LED turns on, the Power Board can be judged as defective
17Y OLED (W7) Power Board Diagnostic method
Disconnect the Main Board 24Pin Power Cable connector.
Connect the 24Pin Power Cable connector to the Muitl Gender JIG 28Pin connector
Switch the LCD MODEL SW to 20V by checking the power voltage.
Fix the LCD MODEL switch to 20V.(Smart JIG)
When the OK LED (24V,12V) turns on, Power Board is normal.
When the NG LED turns on, the Power Board can be judged as defective.