How To Install A 240V Outlet In Garage - EV Car Charger, Welder, And Electric Range (Hubbell 14 50)

แชร์
ฝัง
  • เผยแพร่เมื่อ 8 พ.ค. 2024
  • In this video, I show you how to install a 240 volt outlet in a garage. This 240 volt outlet is also known as the 220 volt outlet for charging an EV car charger, welder, or even an electric range oven. A EV charger requires a 14 50 for a 50 amp outlet. I compare the Hubble 14-50 vs the Leviton 14 50 outlet. #electrical #tesla #diy
    My Favorite Tools And Supplies 👉 www.amazon.com/shop/theexcell...
    Tools And Supplies Used In This Video👇
    Hubbell 14-50 Outlet amzn.to/3QLoNbS
    Hubbell Outlet Cover amzn.to/3QJvqLw
    Surface Mount 14-50R Receptacle amzn.to/3u5J1nS
    6/3 Romex Wire amzn.to/46TotNI
    50 AMP Homeline Breaker amzn.to/3SKgkqT
    2 Gang Metal Box amzn.to/3SulaIE
    3/4” Romex Connectors amzn.to/3FLaMo9
    Mud-Ring 2 Device amzn.to/46YBi9o
    Tesla 14-50 Adapter amzn.to/3FMZf7G
    ChargePoint Charger amzn.to/3MvF6qv
    More Helpful Related Videos👇
    ALL Electrical Playlist • Electrical
    Dryer Receptacle Installation - 4 Prong Outlet Wiring • Dryer Receptacle Insta...
    How To Wire A Sub Panel - VERY DETAILED INSTALLATION! Start To Finish • How To Wire A Sub Pane...
    🟢 Become a channel member:
    / @theexcellentlaborer
    🔴 Subscribe to this DIY channel: th-cam.com/users/theexcellentlabore...
    🟡 Check out my Amazon store: www.amazon.com/shop/theexcell... . Here you will find tools and supplies used in my videos. (DISCLAIMER- I am an Amazon affiliate. I get a small commission that helps support the channel at no extra cost to you)
    Timestamps
    Intro 00:00
    NEMA Outlets Explained 00:28
    240 Volt Supplies 04:14
    6/3 Wire Rough In 06:53
    Metal Electrical Box Installation 08:13
    NEMA 14-50 Outlet Options 11:10
    240V Outlet Installation 14:45
    Connecting 6/3 Wire To Panel 21:04
    50 AMP Breaker Installation 24:37
    240V EV Car Charging 27:38
    Disclaimer: This video is all based on my personal opinion and is for entertainment purposes ONLY. I am not a financial advisor, CPA, attorney, tax advisor, electrician, plumber, housing contractor, designer, or any type of profession to give advice. I am just a consumer sharing my experiences and research. If you do need knowledge for those types of things, I will advise you to seek help for those professionals.
  • แนวปฏิบัติและการใช้ชีวิต

ความคิดเห็น • 369

  • @TheExcellentLaborer
    @TheExcellentLaborer  6 หลายเดือนก่อน +23

    Hey! I covered A LOT of information in this video, so I placed timestamps below to help you navigate this video. Also, you can join the channel using this link th-cam.com/channels/UJXaEduMHGB3Iap3DusmAA.htmljoin . We would love to have you as member!
    NEMA Outlets Explained 00:28
    240 Volt Supplies 04:14
    6/3 Wire Rough In 06:53
    Metal Electrical Box Installation 08:13
    NEMA 14-50 Outlet Options 11:10
    240V Outlet Installation 14:45
    Connecting 6/3 Wire To Panel 21:04
    50 AMP Breaker Installation 24:37
    240V EV Car Charging 27:38

    • @joeboxter3635
      @joeboxter3635 6 หลายเดือนก่อน

      Which one is needed for split air heat pump that says it needs 220V? Eg LG?

    • @scottburchfield8272
      @scottburchfield8272 4 หลายเดือนก่อน

      Can I use a 2/0 2/0 2/0 wire to run a range or stove

    • @solarkbike8
      @solarkbike8 2 หลายเดือนก่อน

      Where is the Ground Fault protection ?

  • @josephleyva7471
    @josephleyva7471 3 หลายเดือนก่อน +4

    I really appreciate how thorough you describe each step. Your a great instructor. Just what I needed. Shalom

  • @joepacheco7979
    @joepacheco7979 2 หลายเดือนก่อน +3

    I think this was the clearest, well explained video I've ever seen on TH-cam. Keep it up. Thanks!

  • @user-uf9mi6yi5b
    @user-uf9mi6yi5b 5 หลายเดือนก่อน +32

    I just want to caution everyone that using NM cable for this circuit limits you to the 60 degree column for Ampacity (NEC 334.80), that's 55A here. Furthermore, maximum current based on a continuous load should be no more than 40A's on this circuit since 125% x 40 = 50A. Therefore, never plug a 48A smart charger into this receptacle as some homeowners down the road may do and perhaps label the receptacle to say 40A MAX if you are going to use these 32A mobile charging cords. Note: even if you use 6AWG THHN rated at 90 degrees, your receptacle can only be used for less than 50 Amps. For me personally, I don't even install receptacles anymore for EV's, as they were just never designed for these high and continuous loads over periods of 8 hours or more. Also consider the constant unplugging and plugging in at the receptacle; your terminals will be lose in no time with a chance for arcing and a fire very high. Buy a hardwired smart charger instead and have it installed by a licensed and insured professional!

    • @curtisbme
      @curtisbme 3 หลายเดือนก่อน +3

      "Also consider the constant unplugging and plugging in at the receptacle" Good guidance however this part wouldn't happen as the charger would get plugged into the outlet and left there. No different than a dryer or other appliance.

    • @JM-iz3fr
      @JM-iz3fr หลายเดือนก่อน +1

      The ev chargers are 240 volt, no neutral necessary. They also are required to be gfci protected

  • @darwood6861
    @darwood6861 หลายเดือนก่อน +1

    Great video. One of the best I've seen. Just call it 240v. In 38 years I've never measured 110v or 220v. All voltage is nominal from the power company, but they have been supplying higher voltages for my entire life

  • @johndernberger1961
    @johndernberger1961 6 หลายเดือนก่อน +9

    Nice job. In reference to the outlet placement for stoves, I recommend reviewing the stove install instructions. There is normally a diagram for the placement for the outlet. I really enjoy your channel.

  • @StashySleepy
    @StashySleepy 8 ชั่วโมงที่ผ่านมา

    The yinzer accent is pristine. Feels like home. 😉
    Excellent video, man.

  • @royquiroz3359
    @royquiroz3359 4 หลายเดือนก่อน

    Excellent step by step explanations and instructions. Thank you!

  • @dustenskinner8404
    @dustenskinner8404 26 วันที่ผ่านมา

    You make great videos man, highly informative and easy to understand. Greatly appreciate you doing the work and teaching the rest of us. Keep up the great work bro 👍🏻

  • @pauljanssen7594
    @pauljanssen7594 5 หลายเดือนก่อน +10

    On that ground wire I usually bend it in a u-shaped so there's more surface, and that 75 inch pounds. Which calculates into 6 foot pounds.

  • @devontrebarlow5980
    @devontrebarlow5980 หลายเดือนก่อน

    Man thank you!! This was very informative and helpful! Exactly what I needed!! 💯

  • @brianerock
    @brianerock หลายเดือนก่อน +6

    A VERY CLEAR demonstration video! Good job! The only omission, however, is that the 2-pole breaker MUST be a GFCI-type breaker per NEC® 210.8(A)(2) and 625.22. Any personnel protection against ground faults internal to the EVSE protects SOLELY the EVSE OUTPUT CORD to the EV but NOT the EVSE INPUT CORD from the NEMA 14-50R receptacle to the EVSE. (Technically that GFCI-type breaker would eliminate the need for refund GFCI protection integral to the EVSE UNLESS the EVSE performs power conversion [nearly all DO NOT convert]).
    - Brian Rock, Hubbell Incorporated,
    I also serve as a CMP-2 and a CMP-15 Member but this is strictly my own position (not NEMA’s and not NFPA’s)
    I also am one of the 7 co-authors of the original (1996) NEC® Article 625 for Electrical Power Research Institute (EPRI).

    • @adamlloy2807
      @adamlloy2807 22 ชั่วโมงที่ผ่านมา

      Brian, I'm in the middle of wiring my detached garage right now, and am having some trouble figuring this one out. It seems that the manufacturer specifies NOT to use a GFCI outlet for an EVSE 40 amp charger (50 amp breaker), and that the EVSE has GFCI built in. That said, I note your comment above regarding input/output. My issue here is that these chargers are known to trip a GFCI outlet or breaker, much like a tredmill does. What is the work around here in order to have a reliable appliance and meet code? My charger is corded - specifically a JuiceBox Pro 40 model and I id wire it into a external waterproof housing containing the NEMA 14-50.
      For that matter - any recommendation for wiring in a treadmill in a detached garage as well? I plan to dedicate an outlet for this and wiring it straight to the panel on a non-GFCI/AFCI breaker.
      Any suggestions?

  • @joshuabowen316
    @joshuabowen316 5 หลายเดือนก่อน +5

    Dude you just saved/made me thousands of dollars you are the MAN.

    • @TheExcellentLaborer
      @TheExcellentLaborer  5 หลายเดือนก่อน

      Awesome! I’m glad I can help. Good luck with the rest of your projects!

  • @keithharrington8715
    @keithharrington8715 5 หลายเดือนก่อน +2

    Josh, you do a good job with your videos. On this one, i would like to stress several things.
    Since this is a subpanel install, the entire panel can be deenergized at the main panel. This should leave zero power in the panel. Yypu did what i would do, but like you i have a high electrical comfort level.
    You did this but did not stress it.....connect away from the panel first. This prevents anyone "helping" from powering the wires in your hand if they are not connected in the panel yet.
    Connecting the wires ground first, then neutral, then hots provides a small level of safety and is a prefered connection order.
    I will reference the 2020 code. Yes it updates every 3 years, so your jurisdiction may be several cycles behind and some requirements may not apply to your jurisdiction.
    Section 90.4 allows your local jurisdiction to accept all, some, or none, of the code. They can change requirements as they deem needed.
    Section 110.14. C. Electrical connections, temperature limits. Puts breakers 100 amps or less at the 60 °c rating for wire current unless the breaker is marked differently. This means the wire you use is rated under the 60° c column of the ampacity chart.(310.16). Yes, thhn is rated at the same as romex. The #6 copper wire is rated at 55 amps, not the thhn rating of 75 amps.
    210.8 (A) gfci protection for dwelling units has upped the voltage to 250 volts or less receptacles require gfci protection when in garages, laundry areas and accessory building at ground level and not a dwelling. Yes, welder and car receptacles.
    314.4 requires metal boxes be grounded.....yes the green screw. Again a safety feature, should the hot wires touch the metal box, it will cause the breaker to trip through the ground wire and prevent the metal plate covering it to be 120 volts.
    Now for the scary one. There is a seperate section for car charging (EVSE).section 625 with specific requirement.
    625.40 points to one outlet (charger) on one breaker.
    625.41 points to the circuit being 125% of the load. 40 amps of charging on a 50 amp circuit.
    625.54. This is the gfci protection if you install a receptacle.
    This is not a hard install as Josh has shown, just make sure you follow the rules. Good luck.

  • @ppomm
    @ppomm 6 หลายเดือนก่อน +5

    Another video where you show what an excellent instructor you are Jost. Lots of detail, clear explanations but yet you keep it moving. I will say that in the elec business a 50A range outlet is x dollars but if you say it''s for an EV it always seems to be 2x dollars lol. Good explanation of why an industrial grade plug is worth the extra money. Thanks for sharing your skills and knowledge!

    • @AdamS-lh2ug
      @AdamS-lh2ug 3 หลายเดือนก่อน +1

      I’ll give him credit for that. It’s worth the extra money for quality plugs.

  • @ViktorVargas-jw2ut
    @ViktorVargas-jw2ut หลายเดือนก่อน

    Great video u literally walked thru every step very helpful

  • @marif6598
    @marif6598 หลายเดือนก่อน

    You explained everything so well. Excellent video.

  • @grzegorzlecki3139
    @grzegorzlecki3139 5 หลายเดือนก่อน

    your videos are so well done and informational. Keep up the great job!

  • @markjoppru8015
    @markjoppru8015 3 หลายเดือนก่อน

    Great job. Appreciate the overview and detail

  • @vbarbee1
    @vbarbee1 5 หลายเดือนก่อน +6

    I'm by no means an electrician, but have Don electrical work and taught by some great electricians. I was always taught when tightening wires against a box to route the wire in the same direction the wire tightens. That way the screw doesn't push the wire out, it draws it in. Use wire strippers not knives especially razor blades. When tightening lugs, tighten, back of, tighten, back off then torque. Also anytime adding new wire to a panel to kill main power. The person who taught me had a saying. The day you get complacent is the day you will get hurt or killed.

    • @darrendolphdragos9752
      @darrendolphdragos9752 3 หลายเดือนก่อน

      " I was always taught when tightening wires against a box to route the wire in the same direction the wire tightens" - When the wire is completely looped IE: out of cable, around screw, then into receptacle... it doesn't matter. Looping clockwise only matters on an open ended (cut) "hook" loop of wire.

    • @mikemm60
      @mikemm60 หลายเดือนก่อน

      or get the proper PPE, tho turning off breaker is cheaper.

  • @Tom-mu7zy
    @Tom-mu7zy 2 หลายเดือนก่อน +2

    Good for you for grounding the outlet box. Too many TH-cam experts fail to do that.

    • @TheExcellentLaborer
      @TheExcellentLaborer  2 หลายเดือนก่อน +1

      I always ground my metal boxes. Thanks!

    • @edgecomber
      @edgecomber หลายเดือนก่อน

      Yes, but he ran the wirec ounterclockwise around the screw. Much more likely to work loose.

  • @michaeltablet8577
    @michaeltablet8577 6 หลายเดือนก่อน +2

    Your videos are always helpful. Thank you very much!

    • @TheExcellentLaborer
      @TheExcellentLaborer  6 หลายเดือนก่อน

      Fantastic! You are very welcome. I appreciate you watching my videos!

  • @optech69
    @optech69 29 วันที่ผ่านมา

    Excellent. Thank you for lending your genius.

  • @AdamS-lh2ug
    @AdamS-lh2ug 6 หลายเดือนก่อน +142

    Don’t wrap your ground counter-clockwise like he did in this video. If you watch closely as he tightens the ground screw it pushes the wire out of the screw. ALWAYS go clockwise when you wrap your wires. This goes for receptacles, and literally everything you wire.

    • @crisestrada9341
      @crisestrada9341 5 หลายเดือนก่อน +10

      Very true, I was about to say something about that as well.

    • @reginaldnoe5613
      @reginaldnoe5613 5 หลายเดือนก่อน +9

      Yep.... one of the first things pointed out to me when first learning to wire recepticles

    • @802Garage
      @802Garage 5 หลายเดือนก่อน +16

      If you noticed, it's a loop, not a hook. Therefore, it's "wrapped" in both directions. Even if he wrapped it the other way to make the loop, it would be the same U shape around the ground screw. Think about the physics. What he did is just fine. The only difference is which side of the loop gets wound tighter and which side gets loosened slightly. You could argue it's slightly better to have the length going to the receptacle tighter because it's going to get moved around, but in practice it will likely have the same impact either way.

    • @josephphillips1777
      @josephphillips1777 5 หลายเดือนก่อน +4

      Or use the pre-made ground tail and "pigtail" your grounds together

    • @BTW...
      @BTW... 5 หลายเดือนก่อน +10

      @@802Garage Bullshit. As the faster tightens it naturally unwinds the loop. Any movement has the wire detach.The terminal is of such poor design, having no means of restraining wire moving from under the fastener.
      Every trade qualified professional electrician knows this... yet you think it's all A-OK.

  • @Berrugasnoquiero
    @Berrugasnoquiero 15 วันที่ผ่านมา

    thanks for the awesome video , very thorough and simple!!!!

  • @carloslagunas859
    @carloslagunas859 หลายเดือนก่อน

    Nice explanation. Thanks I just learned, how to wire a 240..

  • @sudokillall
    @sudokillall 3 หลายเดือนก่อน

    I'm now gonna like this video because it was detailed and informative

  • @fuegoman45
    @fuegoman45 6 หลายเดือนก่อน +4

    Great stuff as always!! Thanks brother 🤙

    • @TheExcellentLaborer
      @TheExcellentLaborer  6 หลายเดือนก่อน +1

      Thanks a lot for tuning into the new video! You are welcome. Take care!

  • @rontiemens2553
    @rontiemens2553 6 หลายเดือนก่อน +3

    Excellent presentation by the Excellent Laborer!

    • @TheExcellentLaborer
      @TheExcellentLaborer  6 หลายเดือนก่อน +1

      Thank you so much! I’ll try to make all of my videos, helpful and useful. I appreciate you watching.

  • @sjpropertyservices3987
    @sjpropertyservices3987 6 หลายเดือนก่อน +1

    Thank you for sharing. Getting ready to install 14-30 generator inlet and process will be similar.

    • @TheExcellentLaborer
      @TheExcellentLaborer  6 หลายเดือนก่อน

      You are welcome! Oh yeah, definitely similar. Good luck with your project!

  • @AdamS-lh2ug
    @AdamS-lh2ug 6 หลายเดือนก่อน +1

    Also, if you have side cutters or really your strippers, you can score the romex and rip it without damaging the wires, you get a much cleaner look in your panel. Strip your wires before going into the panel.

  • @zekenzy6486
    @zekenzy6486 6 หลายเดือนก่อน

    Great Video and information . Thank you for sharing

  • @jeffreyschnabel7536
    @jeffreyschnabel7536 12 วันที่ผ่านมา

    Awesome installation covers everything

  • @greg.montelione
    @greg.montelione 2 หลายเดือนก่อน

    Excellent video instruction of how to rough-in and install a 240 v outlet. This was extremely thorough and very concise. I feel confident that I could now undertake this work on my own.
    The only two questions I still have are;
    1). What size mudring should be used depending on the thickness of the drywall? and
    2). Why not use a two gang box to eliminate the need for the mudring?
    I think part of the answer is what you said about the mudring providing more room in the ox. I get that there is only one device and not two switches or outlets that would require a two gang box but the two gang has the four ears or tabs you'd need to secure the device to the box. Is this just a preference thing or is there another reason for this?
    These are sincere questions. I'm not being critical. I know enough to be dangerous and just like to have all of the information before undertaking work. Either way, I'm going to follow your lead thinking that if it's good for your house... then, it's good for mine. I'm asking in the event you respond before I've started / completed the work.
    Thanks in advance and all the best to you. Keep up the good work. 👍

  • @vicb6019
    @vicb6019 5 หลายเดือนก่อน

    Great Video new subscriber from San Diego

  • @cfrcrd5759
    @cfrcrd5759 4 หลายเดือนก่อน +1

    I thought the video was well done. You were precise and step by step. Sure, you always wrap a wire the way the screw screws in and I usually use a wire stripper in stead of a utility knife to strip the casing but still a well done video. Thanks.

  • @PatrickEArchuleta-fs8bv
    @PatrickEArchuleta-fs8bv 2 หลายเดือนก่อน

    Thanks God bless outstanding work.Bottom line.

  • @TM-td7vk
    @TM-td7vk 5 หลายเดือนก่อน +1

    Your description should had said how to Install a 120/240 EV Charging circuit. In most units the neutral Is not needed but good to have for future use.

  • @leagarner3675
    @leagarner3675 6 หลายเดือนก่อน +2

    Exactly what I needed to know. Thanks!

    • @TheExcellentLaborer
      @TheExcellentLaborer  6 หลายเดือนก่อน

      Excellent I’m glad the video was helpful for you! Thanks for watching!

  • @yorkie1792
    @yorkie1792 4 หลายเดือนก่อน

    Thx. 29:49 was very helpful with all the supplies needed. No sure of the length of the 6'3 wire that I need

  • @ScotianCanadien
    @ScotianCanadien 2 หลายเดือนก่อน +2

    Production quality on your videos, your instruction, your concise communication and your overall knowledge are all very impressive.
    I'm going for a career change at 32, and have been watching all of your electrical videos ahead of getting an apprenticeship.
    Thanks a ton for these

  • @adolfolopez5772
    @adolfolopez5772 หลายเดือนก่อน

    Muchas gracias siempre veo tus videos.saludos from Norwalk california.

  • @TheBlacksun24
    @TheBlacksun24 หลายเดือนก่อน

    Excellent job on this video!

  • @dillardnorg
    @dillardnorg 2 หลายเดือนก่อน

    GREAT VIDEO! THANK YOU, THANK YOU, THANK YOU!

  • @ayubbuildingconsultants
    @ayubbuildingconsultants 6 หลายเดือนก่อน

    Awesome and detailed video as always Josh. Thanks a lot. Was going through your kitchen cabinets video recently and have a question. What is their material ? (MDF/Plywood/Chipboard/Solid wood etc.)

  • @802Garage
    @802Garage 5 หลายเดือนก่อน +5

    I have watched A LOT of these tutorials and done A TON of research into the actual code provisions pertaining to 240V receptacle installs. This is the first video I can point to that is essentially mistake and code violation free. The only exception being GFCI protection, but we all understand why you didn't go that route, hahaha. Awesome job! Will be my go to video to share with others looking for good info.

    • @TheExcellentLaborer
      @TheExcellentLaborer  5 หลายเดือนก่อน +1

      I always try to make my videos as accurate as possible. I’m glad you enjoyed this installation. Thanks for watching!

    • @BTW...
      @BTW... 5 หลายเดือนก่อน +1

      Your wrong about the "mistake free" content here.

    • @802Garage
      @802Garage 5 หลายเดือนก่อน +8

      @@BTW... Point out the mistake then or your comment is completely worthless.

    • @deang5622
      @deang5622 5 หลายเดือนก่อน

      Clearly it is more than just meeting code. See my post on the use of the knife to strip the wires.

    • @802Garage
      @802Garage 5 หลายเดือนก่อน +3

      @@deang5622 I'm not going to go through the entire comments section to find your specific post. If your biggest issue with this video is how he strips off the wire sheathing, I rest my case. You'd be friggin' amazed to see how many electricians do it. 99% of DIY people watching this video are not going to have Romex strippers. This is one of the best and most complete videos on the topic for sure. You can find something wrong with anything if you try hard enough. Nobody is going to have every single piece of information perfect and give every piece of advice possible.

  • @ericfraser7543
    @ericfraser7543 6 หลายเดือนก่อน +8

    13:30 Like you said not all NEMA 14-50 outlets are the same, I would add that the duty cycle of an EV charger can be drawing 50 amps continuously where a standard range outlet was designed to handle the intermittent duty cycle of a range.

    • @TheExcellentLaborer
      @TheExcellentLaborer  6 หลายเดือนก่อน +2

      Yes, good point! The long term continuous draw justifies having an industrial grade outlet versus a range outlet. Thanks for your input!

    • @Lou-jf4rl
      @Lou-jf4rl 6 หลายเดือนก่อน +2

      I installed mine the same way with the same receptical concerns. I also under sized my load to 40 amps because I was concerned about heat created by impedence with such a continuous draw over a 2-3 hour period. I used romex 6/3 due to electrical code but I think that other cables may be better at heat dissipation.

  • @doatoolate.1250
    @doatoolate.1250 6 หลายเดือนก่อน +1

    Thank you for your knowledge. I wish I could worK
    with you and learn all you know.

    • @TheExcellentLaborer
      @TheExcellentLaborer  6 หลายเดือนก่อน

      You are welcome. I’m glad you’re finding my content helpful. I make videos on everything I do DIY. If you watch my videos, you’ll learn most of everything I know. Stay tuned for more!

  • @garyt534
    @garyt534 6 หลายเดือนก่อน +13

    Just to be clear, Torque specs are in inch pounds not foot lbs. Also, it's best practice to use a proper wire stripper instead of a razor blade, that way you won't risk nicking the conductor with the razor blade.

    • @davidhall3747
      @davidhall3747 2 หลายเดือนก่อน

      As an Automotive Technician I noticed that mistake too. Inch pounds and Foot pounds are two different tightening specifications.

    • @paulcrumley9756
      @paulcrumley9756 หลายเดือนก่อน +1

      Newton-meters, too. And in my industry (aviation), there are approved wire strippers that must be used to avoid the likelihood of a violation. I'm surprised how many youtube experts use what would be unapproved tools to strip and crimp wires. Those tools are not excessively expensive, and with them it's almost impossible to harm the wiring or make a connection that is subject to loosening and arcing/catching fire. . .if it's good for a Boeing it's great for my house and vehicle.

  • @thomaslopez155
    @thomaslopez155 2 หลายเดือนก่อน

    ❤it man u are a LIFE SAVER.JYST BOUGHT A HSE AND MAN THEY DUD A $,U AND AVE SAVED ME THOUSANDS. AND YES MY POPS INSPECTOR....COOL BROTHER U KEEP TEACHING ME.THAN KG S AGAIN. ❤IT

  • @dunasingh8653
    @dunasingh8653 4 หลายเดือนก่อน

    Super great video. Thanks a lot.

  • @sma92878
    @sma92878 6 หลายเดือนก่อน +2

    Your videos are amazing, awesome content.

    • @TheExcellentLaborer
      @TheExcellentLaborer  6 หลายเดือนก่อน

      Thank you so much! I appreciate all my subscribers as well. Take care!

  • @agray103
    @agray103 6 หลายเดือนก่อน +1

    Great video! Thanks for sharing 😊

  • @rorm12
    @rorm12 13 วันที่ผ่านมา

    Thank you for the great video! I just have a concern about the Leviton 14-50 Plug used. I keep seeing vidoes of how bad of a plug it is and it causes fires. A lot of folks including Tesla is saying to use Hubbel or a Bryant Plugs instead. I just wanted to get you thoughts on it.

  • @mikekennedy3173
    @mikekennedy3173 2 หลายเดือนก่อน

    Thank you Fantastic video.

  • @user-tf1xg5wo8n
    @user-tf1xg5wo8n 5 หลายเดือนก่อน +1

    Thank You. very helpful.

  • @wick1952
    @wick1952 6 หลายเดือนก่อน +1

    Great job 👍👍 thank you 👍

    • @TheExcellentLaborer
      @TheExcellentLaborer  6 หลายเดือนก่อน

      You are very welcome.I appreciate the compliment!

  • @michaelstora70
    @michaelstora70 4 หลายเดือนก่อน +1

    Recent code revisions require GFCI outdoor or in garages above 20A but that is only for branch circuits (welder, range, EV charger) but it is not allowed on feeder circuits (RV outlet--anything with a subpanel). The same 14-50P could be either.

  • @dankelley9361
    @dankelley9361 6 หลายเดือนก่อน +13

    Josh, excellent descriptive YT video on installing a 50 amp outlet for a EV charger. I would let the viewers know that the 6 nomenclature on the 6-3 wire stands for the AWG or gauge of wire needed to withstand the 50 amp current draw.

    • @TheExcellentLaborer
      @TheExcellentLaborer  6 หลายเดือนก่อน +3

      Thanks a lot, Dan! I did explain what AWG was in my last video. You’re right, I would have not heard to mention it again. Thanks for watching!

  • @user-cw8rw8ug3k
    @user-cw8rw8ug3k 2 หลายเดือนก่อน

    Nice explanation

  • @stuartmarkman769
    @stuartmarkman769 5 ชั่วโมงที่ผ่านมา

    I was tought too wrap wires clockwise around screws so they stayed tight and didn't spread out. It just works better. Torque is rated in inch or foot pounds. The wire screws are tightened too INCH pounds.

  • @peterchow4577
    @peterchow4577 6 หลายเดือนก่อน

    Thanks Josh another great video. Just want to know if you have the link for the torque screwdriver? 👍

  • @KevinCoop1
    @KevinCoop1 6 หลายเดือนก่อน +6

    Excellent video and explanations. Technically you installed a 120/240 volt outlet. For those that do not want to spend $90 for the receptacle, Bryant (owned by Hubbell) same exact device is approximately half price. Why cheaper? If Hubbell can get named in the specifications for a large project, then higher profit. They bought Bridgeport out in 1991 which makes the Bryant devices. Never use cheap receptacles for car chargers. They overheat.

    • @LuLu_World
      @LuLu_World 8 ชั่วโมงที่ผ่านมา

      they did not buy bridgeport. bryant was located in bpt ct

  • @greg3296
    @greg3296 6 หลายเดือนก่อน +1

    Very well explained

  • @paulroberts2549
    @paulroberts2549 5 หลายเดือนก่อน

    Great job.

  • @MitchellRose-gi2ln
    @MitchellRose-gi2ln 9 วันที่ผ่านมา

    Great! Much thanks.

    • @blackhorse2947
      @blackhorse2947 9 วันที่ผ่านมา

      I have a wood lathe that runs on 220v. I have moved it to a better location in shop, unfortunately the power cable will not reach it now. The lathe now is 6fr from the existing outlet. Can I daisy chain from the existing location to the new receptacle or home run from power panel. I never run any of my 220v machines at the same time. I would appreciate your thought, and I am a new subscriber…. Enjoy your excellent videos

  • @anthonyesparsen9453
    @anthonyesparsen9453 หลายเดือนก่อน +2

    Don't forget follow local NEC codes where gfci and arcfault protection may be required

  • @Amer-yl4gb
    @Amer-yl4gb 5 หลายเดือนก่อน +4

    Great information video. I notice 1 mistake and that was you installed the 3/4 cable clamp backward. The screws for the clamp has to be inside the box. This is because incase in future they need to get more wire inside box on a finished wall they can loosen the screws and pull some wire inside the box.

    • @JohnThomas-lq5qp
      @JohnThomas-lq5qp 5 หลายเดือนก่อน

      Wrong. Two screw connectors should have the screws on outside of the box. Don't think inspectors like your way. With NMB cable stapled within 12" of a box next to impossible to pull in more wire.

    • @Amer-yl4gb
      @Amer-yl4gb 5 หลายเดือนก่อน

      @@JohnThomas-lq5qp lol please dont make things up out of the blue. This has nothing to do with the inspector, this is about the design engineering and proper function. First of all it doesnt matter what inspector likes or doesnt like. As per code, a cable must be secured to the box by the method the manufacturer of device/fastener has specified. 2nd of all, USUALLY (but not a requirement), a GOOD electrician will leave a slack of wire in the form of S between the box and the staple. A house lives for 100 years and during this time if someone mess up wires when connecting the devices, they'd have the option to pull in some slack into the box.
      A good example of this is the plastic push-in connectors for NMD wires where you can pull wires into box but not out.
      2nd example is the regular NMD respectable boxes with the screw inside the box to secure the cable.

    • @JohnThomas-lq5qp
      @JohnThomas-lq5qp 5 หลายเดือนก่อน

      Did you ever have a job inspected? The inspector or AHJ has the final say. With 12/2 costing what a $1 a foot a little over a year ago no electrician will install stupid money wasting S bends for cables entering a box. The NEC mandates a support within 12" of boxes feed with NMB cable so that makes it very difficult to make a S bend and provide the 12" support. Metal box manufacturers never supplied type of connector to be used in their boxes. There are over a quarter Millon words in the NEC and hundreds of exceptions to all of the articles and like I have been told at the over 100 continuing education classes that I attended to renew my electrical license is if you ask 3 inspectors you might get 4 answers. The few times that I objected to an hick prima Donna only inspector in a little town that attempted to write me up for code violations I won out. Best was after my inspector passed a job local hick tried to I give me a violation for making a single splice on a 14 gauge wire inside if a circuit breaker panel. After I gave him the NEC article that allows it told me that he would let me get away with it that time. After many years still learning.

    • @Amer-yl4gb
      @Amer-yl4gb 5 หลายเดือนก่อน +2

      @@JohnThomas-lq5qp I do agree with you... with the copper prices after Covid no one is doing that S thing anymore. I learned that when I was a kid doing construction jobs here and there. But we do electrical cabinets for manufacturing segments. Complying with residential codes is child's play compare to industrial codes and regulations. I personally done 2 full basements and 3 house renovations jobs so far... maybe I was lucky I haven't had a jerk for a inspector... and yes like you said there been time when the inspector has said "you can't do this" and I told him yes I can and here's what the code says and then he would ok ok fine but I wouldnt do it like that... and moved on to the next item... inspectors just verify your are up to the code and if your are then it doesn't matter what he personally feels about your job.

    • @Amer-yl4gb
      @Amer-yl4gb 5 หลายเดือนก่อน +1

      What led me to this video was out of frustration in fitting a 14-50 receptacle in a 2-gang box. Usually a 4-11/16 box is used like the oven. But I wanted to minimize the drywall damage in the already finished garage and the fact that the receptacle bag said use a 2-gang box. Now when I was trying to wire 6/3 cable to it and intall it, the receptacle plate bent. So I wanted to see how others do this 😅. Anyways I cut the wires much shorter and pre bent wires and that still was hard to install but it went in fine.

  • @sjpropertyservices3987
    @sjpropertyservices3987 6 หลายเดือนก่อน +1

    Thank you!

  • @richstarstar
    @richstarstar 6 หลายเดือนก่อน +1

    Good job. Love the video. how did you estimate the length of the run so good. You had a drawing to work from or you just use a tape measure and guestimate?

    • @TheExcellentLaborer
      @TheExcellentLaborer  6 หลายเดือนก่อน +1

      Thanks! I’m glad you love the video. I use a 100 foot tape and then run it where the wire will be installed. I simply just use that measurement to buy the length of wire. I hope that helps!

    • @richstarstar
      @richstarstar 6 หลายเดือนก่อน

      Thanks for the response. @@TheExcellentLaborer

  • @wlit
    @wlit 4 หลายเดือนก่อน

    Thank you for the video. Can you provide the link to the cover at 5:38 what will work on the Hubbell 14-50 Outlet?

  • @novamaggart3251
    @novamaggart3251 6 หลายเดือนก่อน +4

    Excellent video. Would you mind sharing which torque screwdriver you used in this video? I did not see it mentioned in the list of tools used in this video. Thank you. Also, did you really torque the screws to 75 in-lbs?

    • @TheExcellentLaborer
      @TheExcellentLaborer  6 หลายเดือนก่อน +2

      Thank you! I’m not sure the exact brand of the screwdriver because I borrowed it from a friend for this install. I had the dial pass 70 to get the torque which should be around 75 lbs. I hope that helps!

  • @fujimoto31
    @fujimoto31 หลายเดือนก่อน +1

    Thanks!

    • @TheExcellentLaborer
      @TheExcellentLaborer  หลายเดือนก่อน

      You’re welcome. Thanks a lot for the support!

  • @ChargePointnet
    @ChargePointnet 6 หลายเดือนก่อน +2

    Hey, thanks for the shoutout ⚡We make home charging simple and easy for every EV!

  • @charliefraser793
    @charliefraser793 6 หลายเดือนก่อน +4

    Nice job hard worker

    • @TheExcellentLaborer
      @TheExcellentLaborer  6 หลายเดือนก่อน

      Thank you for the nice compliment!

    • @charliefraser793
      @charliefraser793 6 หลายเดือนก่อน

      @@TheExcellentLaborer your welcome your nice guy

  • @dunckeroo1987
    @dunckeroo1987 3 หลายเดือนก่อน

    For a range, it is probably better to install under 8 inches to accommodate for standard or short drawer space -- that is the space behind the drawer that provides space for the plug. You might want to face the ground towards left or right -- some cords have the ground up and some have the ground down, and you want the loop to slide back in easy.

  • @ShamelessHellions
    @ShamelessHellions หลายเดือนก่อน

    For EV supply equipment, direct wire is the way to go. Much less possibility of the equipment melting down vs the cord and plug method. Also, you would avoid an unnecessary expense of the outlet. The cheap leviton outlets are fine for a range, but are a legit fire hazard on EVSE. The wire used for direct wire will save some $$ as well. EVSE use 2 wire with ground and don’t require a neutral. I do like how this installer used a torque screwdriver. Properly torquing the terminals are important for every install (just look at manufacturers instructions), but especially when there is a significant current draw.

  • @gillesbourbonnais4805
    @gillesbourbonnais4805 2 หลายเดือนก่อน

    Thank you for the explenation but I will get an electricent rader go safe 😑 from Québec Canada

  • @joseharo3273
    @joseharo3273 5 หลายเดือนก่อน

    Great video just wondering how much an electrician must charge for a job like this

  • @royrodas6704
    @royrodas6704 5 หลายเดือนก่อน

    good job I like it I want to become a teacher like you

  • @CLTNY1
    @CLTNY1 6 หลายเดือนก่อน +1

    Excellent.

  • @bennyplasencia2426
    @bennyplasencia2426 8 วันที่ผ่านมา

    I am now going to like this video

  • @jayjohns5653
    @jayjohns5653 15 วันที่ผ่านมา

    The ground wire should be wrapped around the ground screw clockwise so it gets pulled in when you tighten it rather than squished out. When you strip wires with a knife the blade must be more parallel the the wire to come in a shallow angle so you don't nick the wire which is like scoring a piece of glass. The wire will break at the nick if it is subjected to constant vibration like from a motor.

  • @pjdambra
    @pjdambra 4 หลายเดือนก่อน

    If you are using the Tesla Mobile Charger. Remember to mount the box a foot higher and orient the receptacle in the right direction so as the charger hangs straight down. Then you must support the charger itself so it doesn't disconnect the adapter from charger.

  • @ginjeff
    @ginjeff 4 หลายเดือนก่อน

    625.54 Ground-Fault Circuit-Interrupter Protection for Personnel.
    In addition to the requirements in 210.8, all receptacles installed for the connection of electric vehicle charging shall have ground-fault circuit-interrupter protection for personnel.

  • @anthonyesparsen9453
    @anthonyesparsen9453 หลายเดือนก่อน +1

    I'm your code expert recently retired 25 year's of service 60,000 inspections under my belt

  • @JRP3
    @JRP3 5 หลายเดือนก่อน

    The outlet you installed is self grounding, you can see the strip of metal going from the ground terminal to the face plate, so you don't need to connect the ground wire to the grounding screw of the box. That connection is created automatically when the outlet is attached to the box.

    • @802Garage
      @802Garage 5 หลายเดือนก่อน +2

      Given the Voltage and Amperage at play, even if it isn't a code violation, HIGHLY recommended you ground the receptacle as well as of course the box as required by code.

    • @JRP3
      @JRP3 5 หลายเดือนก่อน

      @@802Garage The box and outlet are already grounded when installed since it's self grounding, which is the shortest path to ground. Adding extra wire does nothing.

    • @802Garage
      @802Garage 5 หลายเดือนก่อน

      @@JRP3 No, the box is not grounded unless the EGC is bonded to the box, which is absolutely required by code unless the box is grounded by EMT conduit grounded at the supply panel. Read NEC 250.148 please. It is also against code to ground the box with the receptacle even if the receptacle has an EGC connected and is self-grounding. This would violate the ground continuity rule. As for doing nothing to bond both, the primary reasons to do so are increased ground capacity, which increases the chances of a circuit breaker trip if there ever is a ground fault, it keeps the receptacle grounded even when removed from the box in case power was accidentally not shut off or there was another wiring fault, it is a more reliable connection than the self-grounding connection in general in terms of clamping force, total area of connection, direct path to ground,orand inability to move, and that leads to the last point which is over time the receptacle could loosen from the box which will decrease the self-grounding contact or eliminate it entirely and it also leaves room for error during install where someone may not tighten the self-grounding receptacle all the way when they are trying to get a tidy flush fit. Bonding the box and the receptacle is common practice for added safety and there is essentially no downside since the required grounding wire is already present and long enough to be used. It also makes sense to use and leave the ground in tact in case a different piece of equipment is later installed in the box which does require a ground.

    • @BTW...
      @BTW... 5 หลายเดือนก่อน

      @@JRP3 Bullshit - What happens when the lid is lifted? Ground is disconnected, you idiot.
      So you think a metal strip held by cove plate fasteners (that can come loose or thread strip) is a low impedance path from the Ground terminal of the socket to ground/Earth?

  • @michaelwells7348
    @michaelwells7348 2 หลายเดือนก่อน

    ~ I liked the Video Bruh... easy to follow & very informative ....

  • @anthonyesparsen9453
    @anthonyesparsen9453 หลายเดือนก่อน +1

    I'm seeing pretty much all you advising electrical outlet wiring with out basic requirements

  • @tonylozano8574
    @tonylozano8574 2 หลายเดือนก่อน

    Great video, I've learned a lot and it's information what needs to be done, but I won't do it. I'm thinking of buying an EV, but how do I assess If I can install another 240 volt outlet? For me, to call for a electrical assessment it will cost about $300. I live near San Francisco. So how do I assess my electrical box?

  • @joshscott301
    @joshscott301 4 หลายเดือนก่อน +1

    I believe there have been problems using cheap stove outlets for EV charging. Generally the stove outlets weren't built to handle that high of voltage for 5,6,7, 8-12 hours at a time like an EV does. It would be similar to all burners on high and stove on boiler all night every night. A stove would rarely be used at that voltage and never for longer than a few minutes before being turned down if it was .

    • @davegibson4255
      @davegibson4255 4 หลายเดือนก่อน

      You don’t know what you are talking about they are the same size metals inside and have to be or would never pass UL listings and the voltage is the same it’s the current/amperage that sizes everything when it comes to wire gauge other than industrial commercial wire rated to 600volt and higher

  • @anthonyesparsen9453
    @anthonyesparsen9453 หลายเดือนก่อน +1

    Most of these new 220 outlets require gfci and maybe afci protection per nec

  • @TheHearseAroundJimThorpe
    @TheHearseAroundJimThorpe 5 หลายเดือนก่อน

    If I want to put in an oven and a dryer those have to be 2 separate 240 V circuits correct?

  • @joejoeaz47
    @joejoeaz47 17 วันที่ผ่านมา

    Is it code to use the 6/3 exposed on surface mount?

  • @vincentrobinette1507
    @vincentrobinette1507 6 หลายเดือนก่อน

    I would install the 14-50 with the round earth ground down. The EVSE provided with the Chevrolet Bolt has the round pin down, so the cable hangs down when plugged in. Otherwise, I would need a shelf above the outlet, because the cable would point up, rather than dangle down. The cable between the plug and the EVSE box is only~12 inches, making it difficult, if it can't just hang down.

    • @JRP3
      @JRP3 5 หลายเดือนก่อน +1

      Depends on the vehicle, Tesla EVSE has the ground pin on top.

  • @dmark6699
    @dmark6699 3 หลายเดือนก่อน +1

    Very Good.

  • @jby5736
    @jby5736 18 วันที่ผ่านมา

    Just to clarify when you torque the Allen lugs on outlet and breaker. He says pounds but make sure it is inch pounds. Because foot pound is for lug nuts. So if you have a inch pound torque wrench you can use that instead of having to buy a special torque screwdriver.

  • @AdamS-lh2ug
    @AdamS-lh2ug 6 หลายเดือนก่อน

    Strip your wires before you put your wire through your connectors/boxes. You’ll get a cleaner look and it’s easier and faster. Code is 6” from the back of the box or minimum 3” from the front if you have some seriously deep box.

  • @dunckeroo1987
    @dunckeroo1987 3 หลายเดือนก่อน

    It's a good habit to run your 3 mains up the same side of the panel to reduce hum and noise. Your not seeking to use you panel as a one turn inductor or create a phantom voltage in your neutral. You likely don't hear these hums until you enter a big electrical room.

  • @treyblack9736
    @treyblack9736 3 หลายเดือนก่อน

    Is the ground wire still connected to the box? It looks like it’s no longer connected when you started connecting it to the plug.