Condenser Was Buzzing Loudly, Then It Sounded Like It Was Going To Take Off

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 ม.ค. 2025

ความคิดเห็น • 117

  • @billyk5107
    @billyk5107 ปีที่แล้ว +11

    I got my veto pro pack LC yesterday . It made the service call a dream to get to tools and see everything easily. I set it up just like yours I was able to pull my field piece probes out, get to my electrical meter and get to my needle nose and anything else I needed. This bag is great .The Milwaukee one was not working for me.

    • @HVACGUY
      @HVACGUY  ปีที่แล้ว +1

      They do make great bags

  • @sknight0391
    @sknight0391 ปีที่แล้ว +14

    That sounded like somebody was getting buzzed through the door at the jailhouse. 😆😎👍

  • @TLM-Nathan
    @TLM-Nathan ปีที่แล้ว +10

    I have a window unit that does this every now and then. Was curious what would have caused it. Not in the field but I absolutely love the videos, I am always learning from you & some others. Thank you so much for taking the time to video, edit and upload these.

    • @HVACGUY
      @HVACGUY  ปีที่แล้ว +3

      Thanks for watching

  • @RadioReprised
    @RadioReprised ปีที่แล้ว +3

    Rod is GOING!

  • @rrbigdad
    @rrbigdad ปีที่แล้ว +1

    Thanks for all the information you give my supervisor came in yesterday and the problem he was describing sounded like the capacitor so he changed it and it worked thanks

  • @LTDANMAN44
    @LTDANMAN44 ปีที่แล้ว +8

    TIME FOR A NEW COMPRESSOR!

  • @549BR
    @549BR ปีที่แล้ว +21

    Giving the phrase "sounding bad" new meaning; did you call the church to have the last rites administered? 😎

    • @HVACGUY
      @HVACGUY  ปีที่แล้ว +6

      Yeh that sounded rough didn’t it?

  • @markjones7268
    @markjones7268 ปีที่แล้ว +3

    The Inrush current has me fascinated

  • @jamesfitzsimmons381
    @jamesfitzsimmons381 ปีที่แล้ว +2

    Good call

  • @Paul-IE-Repairs
    @Paul-IE-Repairs ปีที่แล้ว +2

    that K55HXLRH-0824 motor calls for a 10uf capacitor

  • @JorgenFitnesz
    @JorgenFitnesz ปีที่แล้ว +1

    I liked how it sounds even tho it’s not good haha

  • @JetTDi
    @JetTDi ปีที่แล้ว +6

    Something similar happened to my heat pump. It would buzz like that every 30 seconds or so. It was dimming our neighbors street light 3 houses down. I would have loved to see its amp draw when it was buzzing! Was Surprised it didn’t trip the breaker

  • @Hvac-dude
    @Hvac-dude ปีที่แล้ว +5

    Sounds like another compressor replacement 😊

  • @sergioblanco4504
    @sergioblanco4504 ปีที่แล้ว +3

    Definitely sounded like it was going to 💥

  • @HardDriveGuruOfficial
    @HardDriveGuruOfficial ปีที่แล้ว +3

    I had two competing captions for the buzz at 0:32!
    1. "Ma, food is done!"
    2. "WRONG!"

  • @ammar3094
    @ammar3094 ปีที่แล้ว +4

    this sound happened to me, i replaced the fan motor and cleaned the coils and got rid of an unneeded small capacitor and compressor boost and bam worked

    • @phan282002
      @phan282002 5 หลายเดือนก่อน

      Same here. My tech replaced the fan motor and start capacitor, and it worked just fine.

  • @jerryc3050
    @jerryc3050 ปีที่แล้ว +3

    lol, it sounded like when my son's car threw a rod... 👍

  • @throttlebottle5906
    @throttlebottle5906 ปีที่แล้ว +4

    uhoh, BZZZZZZZTTT, the death buzz. if the building dwellers notice the lack of cooling and shut it off right away.? it just may survive, if they don't and it repeats for minutes/hours/days/weeks/months? good chance that it is 100% dead or will fail shortly after repair.
    I was sitting here one day and thought what's that weird screaming noise, I heard the echoed off noise for hours that day and didn't recognize it. as I was leaving in the evening, I heard it again and instantly knew what it was, neighbors condenser had an old composite pad sitting on top of it, blocking the air flow, the noise was screaming compressor bypass. it didn't sound that way next door/through windows and fans running, but once exited into driveway to get in vehicle? my ears went started bleeding I hard and spotted the now very clear noise, ran over and uncovered the condenser. that was 3+ years ago.

  • @johnblume2549
    @johnblume2549 ปีที่แล้ว +2

    I have had that buzz when the contactor gets stuck halfway confused, usually after a power outage. I just reset the contactor. That compressor did not sound good when it was running though.

  • @jericosha2842
    @jericosha2842 ปีที่แล้ว +2

    Sounds good from my house 👍

  • @manonfire3642
    @manonfire3642 ปีที่แล้ว +6

    Did you change out the compressor? If so, did that fix problem? Update please. Thanks.

    • @HVACGUY
      @HVACGUY  ปีที่แล้ว +3

      I haven’t heard from home owner yet

  • @DRNEGOLICIS
    @DRNEGOLICIS ปีที่แล้ว +2

    I’ve had that happen, turns out they had the wild leg connected to service on the transformer, compressor was running backwards, I reversed it and it was happier , never was quite the same. So I guess my question is , did you make sure it wasn’t running backwards?

  • @dannysmith713
    @dannysmith713 ปีที่แล้ว +2

    Protech fan motors have the capacitor information on the right side of the motor information above the barcode

  • @takethe101totarzana4
    @takethe101totarzana4 ปีที่แล้ว +3

    Its gonzo. Hope you get the work.

  • @hinspect
    @hinspect ปีที่แล้ว +6

    Thanks for the Video!
    Is there any way the Contactor could have been buzzing? Enjoyed watching! 👍🇺🇸

  • @Garth2011
    @Garth2011 ปีที่แล้ว +2

    Nice diag. Seems to be that HP on condenser fans tend to follow a trend when it comes to capacitors. 1/4 HP=5 mfd, 1/3 HP=7.5 mfd, 1/2 HP=7.5 and 3/4 & 1 HP are usually 10 mfd. That CAP did read 10 for the brown wire so likely all was correct with that CAP rating for the condenser..

  • @tomking1890
    @tomking1890 ปีที่แล้ว +2

    Well what did you do?

  • @kens.3729
    @kens.3729 ปีที่แล้ว +3

    If you hear the Death Buzz, Call Curtis for Prompt and Courteous Service. 😬👍🙏

  • @bretthibbs6083
    @bretthibbs6083 ปีที่แล้ว +4

    that sounded like the russian woodpecker lol it's a jamming signal the russia used back in the day and I think still uses

  • @jenko701
    @jenko701 ปีที่แล้ว +2

    They need one .

  • @JRS-iq9pz
    @JRS-iq9pz ปีที่แล้ว +1

    So what was the fix? A new compressor?

  • @Dillonmechanical
    @Dillonmechanical ปีที่แล้ว +6

    Did it have any refrigerant in it?

  • @abdulchehab8805
    @abdulchehab8805 5 หลายเดือนก่อน

    Good video thanks

  • @manonfire3642
    @manonfire3642 ปีที่แล้ว +3

    What's the number of the large magnetic light that you use?

    • @HVACGUY
      @HVACGUY  ปีที่แล้ว +1

      It’s an M12 rover by Milwaukee

    • @manonfire3642
      @manonfire3642 ปีที่แล้ว +1

      @HVACGUY thanks for replying

  • @jimburgess9205
    @jimburgess9205 ปีที่แล้ว +4

    That sounds like a locked up compressor to me. $$$

  • @jamierushing
    @jamierushing ปีที่แล้ว +3

    Hi bro from west Alabama

  • @jw33
    @jw33 ปีที่แล้ว +4

    If you get the job cut the compressor case open and show everyone what it looks like inside and what went wrong when the season slows down....

  • @chetspencer3241
    @chetspencer3241 ปีที่แล้ว +1

    what was the problem? Bad compressor?

  • @danpresson
    @danpresson ปีที่แล้ว +3

    Great video definitely ready to explode

  • @Aerospace_EdC
    @Aerospace_EdC ปีที่แล้ว +4

    Curtis in this situation is it more cost effective to change the compressor or the whole outdoor unit ? I guess it depends on how old everything is ?

    • @Austin23191
      @Austin23191 ปีที่แล้ว +1

      I would say 10-12 years old. It has a copeland scroll. My ac which would've been 18 this year had a Bristol recip. I think they switched to the copelands around 2010

    • @CG-1000-T
      @CG-1000-T ปีที่แล้ว

      ⁠@@Austin23191I had 3 ruud units from 2008 with Copeland scroll compressor. Those units were POS.

    • @sprockkets
      @sprockkets ปีที่แล้ว +1

      ​@@CG-1000-Tall the good old Rheem had Copeland scrolls in the 90s.

    • @CG-1000-T
      @CG-1000-T ปีที่แล้ว

      @@sprockkets I know as I have seen one

  • @harrydickson4575
    @harrydickson4575 ปีที่แล้ว +3

    Change out the video coming soon or compressor lol 👍👍👍

  • @mikedillon6233
    @mikedillon6233 ปีที่แล้ว +3

    Yeah, it sounds like it's time to take it out and put It out of its misery! LOL!

  • @gordonpotts753
    @gordonpotts753 ปีที่แล้ว +1

    One of the downsides of a Copeland Scroll is they don't have an oil pump.

  • @stephenhunter70
    @stephenhunter70 ปีที่แล้ว +2

    Compressor is in need of replacing.

  • @Iosksnwjwnijujw8
    @Iosksnwjwnijujw8 ปีที่แล้ว +2

    Looks like they’ll need a change out .

  • @ronroberts7566
    @ronroberts7566 ปีที่แล้ว +4

    I didn’t see you measure the load voltage on the contactor, did you verify you had adequate voltage

    • @Metal3983
      @Metal3983 ปีที่แล้ว +2

      Especially with that FP fused disconnect. You could have loose connections..

    • @ronroberts7566
      @ronroberts7566 ปีที่แล้ว +2

      loose connections at the disconnect aluminum connectors, corrosion due to lack of anti oxident paste, contactor pitting, really need to measure and not assume voltage is adequate

    • @totallynotbreezytheboss7218
      @totallynotbreezytheboss7218 ปีที่แล้ว +2

      Regardless that's a freakin mechanical failure inside the compressor

  • @HNIC86
    @HNIC86 ปีที่แล้ว +1

    Sounds like the compressor is going out

  • @brandonprice2897
    @brandonprice2897 ปีที่แล้ว +4

    Just curious, did you have to reverse the wiring in order to get it to run? But definitely sounds like you’re about to have a new compressor change out video coming.

    • @HVACGUY
      @HVACGUY  ปีที่แล้ว +1

      No, just put on that super boost

    • @brandonprice2897
      @brandonprice2897 ปีที่แล้ว +2

      @@HVACGUY sounds like you have a compressor change out vid coming soon?

    • @mwatkins2464
      @mwatkins2464 ปีที่แล้ว

      @@HVACGUYyou left it running with the boost while you can hear the mechanical issues going on?? I wouldn’t have left it running like that.

    • @lukelong2270
      @lukelong2270 ปีที่แล้ว +3

      @@mwatkins2464 things already shot, not much more damage can be done. the compressor will open if it over heats and protect anything else.

  • @natersalad889
    @natersalad889 ปีที่แล้ว +8

    Idea: are the compressor connectors all the same, or maybe a couple different ones? They all seem to look the same on your videos and if so... why dont you make yourself a plug from an old harness from one and have it be like 3 feet long or something with regular spade terminals on the other end of the wires and you can use it to easily reach down and unplug the harness, plug your test pigtail into the conpressor and quickly and comfortably do your checks?

    • @jw33
      @jw33 ปีที่แล้ว +1

      I was thinking the same thing. It's called a breakout box.

    • @natersalad889
      @natersalad889 ปีที่แล้ว +1

      ​@jw33 yeah, I see him struggling to get a good connection and accurate readings all the time. This will definitely speed up that process

    • @chuckquinn8026
      @chuckquinn8026 ปีที่แล้ว +1

      I asked the same question a while back 🤷‍♂️

    • @fldave612
      @fldave612 ปีที่แล้ว +2

      It's logical to think that ohming out compressors that way with a pigtail harness, but that extra 3+ feet of wire can give a slightly higher resistance reading than what is actually in the windings themselves, by going directly to the pins you're ohming out the windings directly at there actual lenght on the stators w/o adding addtional to it. Take note when watching most HVAC techs you almost never see them ohm out compressor windings using the harness wiring in the unit, even if it's fully disconnected from the cap and contactors. If a winding is supposed to be 1.2 ohms for example per the mfg, but the actual readout at the pins is 0.7 ohms, you add a short length of pigtail and not realizing it, that pigtail has say 0.3 ohms, you're goign to be like, no problem, it's within tolerance, but in reality it's below the minimum threshold.

    • @natersalad889
      @natersalad889 ปีที่แล้ว +2

      ​@fldave612 true, to eliminate that you can check the value of the harness each time prior to using it just like checking your leads on your meter before testing resistance by putting the ends of the leads together and making sure is 0.00 ohms, just make sure the harness is the same each time as one process

  • @tieron426
    @tieron426 ปีที่แล้ว +2

    I did not see what brand this was? However, I like how the capacitor is located on this brand and I assume this helps to keep it cooler and it should last longer by being cooled?
    Do you have any knowledge if this make the capacitor last longer? It just amazes me that capacitors only last about 2 years before exploding. (I am not a hvac technician.)

    • @mwatkins2464
      @mwatkins2464 ปีที่แล้ว

      Most capacitors last longer than 2 years. They do go bad but not to that extent. You will always have something tear up on anything but for the most part they do last unless they are China or Mexico made

  • @handymanbrian8269
    @handymanbrian8269 ปีที่แล้ว

    SOUNDS LIKE COMPRESSOR WAS RUNNING IN REVERSE.
    id also disconnect the fan motor while testing *

  • @TheSimba86
    @TheSimba86 ปีที่แล้ว +10

    HVAC work is like 49% changing capacitors, 49% cleaning coils and filters and like 2% actual hard technical troubleshooting

    • @roberts1159
      @roberts1159 ปีที่แล้ว +5

      Don’t forget clearing blocked condensate drains !

    • @panamacitybeachbum
      @panamacitybeachbum ปีที่แล้ว +7

      Sure it is, until it isn't. Then you get to earn your keep.

    • @jaymz0074
      @jaymz0074 ปีที่แล้ว

      Unless you're in commercial

    • @mwatkins2464
      @mwatkins2464 ปีที่แล้ว

      Yea well why don’t you start fixing your own. You won’t last. It takes 2 years to learn the basics then on job learning starts but your so smart you don’t have to know all the other stuff. Do you get what I’m saying, about you. It’s not good

    • @RetiredSignDude
      @RetiredSignDude ปีที่แล้ว +1

      You left out the 30% that is cleaning the drain line !

  • @Techraingeek
    @Techraingeek 7 หลายเดือนก่อน

    0:32 Laundry is done!

  • @Chris2745100
    @Chris2745100 ปีที่แล้ว

    When a compressor is running backwards it can sound like that.

  • @CGGC0202
    @CGGC0202 ปีที่แล้ว +1

    you dont show the fix?! you just leave it at that ?

  • @rciancia
    @rciancia ปีที่แล้ว

    Pretty sure that motor is a 10uF

  • @hvactech77
    @hvactech77 ปีที่แล้ว

    The next question will be what else may be wrong. Put a new compressor in and find a bad TXV, dirty evaporator, low charge, etc. Likely something caused the failure not just age.

    • @BrokenRRT
      @BrokenRRT ปีที่แล้ว +1

      I suspect there’s out of acceptable voltage drops and spikes from the transformer feeding the main to house.
      I have a neighbor in my rural area that was having same issues and it was the transformer at the pole wiping out his appliances.

    • @hvactech77
      @hvactech77 ปีที่แล้ว +1

      Possibly but I don’t see that much for compressors failure on single phase. That will take out cheap capacitors though. I’m thinking something else will be wrong.

  • @tombeilman5579
    @tombeilman5579 ปีที่แล้ว +3

    Compressor go fubar

  • @SDPP992
    @SDPP992 ปีที่แล้ว +2

    Bet that thing could fly to africa and back

  • @Balticblue93
    @Balticblue93 ปีที่แล้ว +6

    Wait a second, you never once checked if the system had any refrigerant in the system! That is exactly what a compressor sounds like with no refrigerant. If you didn't gauge up, how could you possibly know? Did you quote them a new condenser, compressor or full change-out? The capacitor was good, the readings across the compressor terminals were nearly dead on. Are you sure there isn't a leak that vented all the refrigerant or a majority of it out? I have seen this more than once in my career.

    • @totallynotbreezytheboss7218
      @totallynotbreezytheboss7218 ปีที่แล้ว +2

      Did you get your training from TH-cam? 😂😂😂 Clearly that's a doa compressor

    • @Balticblue93
      @Balticblue93 ปีที่แล้ว +2

      @@totallynotbreezytheboss7218 That's funny all things considered. DOA is dead on arrival, I suppose it might have been. At the end of the day, a empty compressor sounds like marbles bouncing around. I bet that compressor was flat and empty based on the readings taken across the compressor terminals. I have seen it before, so without checking it, it is just guessing. So did he sell them a new condenser or a full system?

    • @Bryan-Hensley
      @Bryan-Hensley ปีที่แล้ว +7

      You won't have a high amp draw like that with no refrigerant.

    • @Balticblue93
      @Balticblue93 ปีที่แล้ว +1

      @@Bryan-Hensley Of course you will have high amp draw on a compressor that is struggling because of a lack of refrigerant. Does it just give up and stop working? No, it works harder and the amps skyrocket.

    • @Bryan-Hensley
      @Bryan-Hensley ปีที่แล้ว +2

      @@Balticblue93 no it doesn't. No load on the compressor. less amp..

  • @rgruenhaus
    @rgruenhaus ปีที่แล้ว +1

    Doing half the fix is a video?

  • @daddygc5814
    @daddygc5814 ปีที่แล้ว +1

    Sounds like its out of refrigerant

  • @mikemoseley8711
    @mikemoseley8711 ปีที่แล้ว +3

    Internal failure

  • @browntigerus
    @browntigerus ปีที่แล้ว +2

    Didn't think the capacitor. Normally these sounds on electric motors = loose motor core.... (few times in my life, EE degree was useful, lol). Check compressor oil, most likely - will be changeout.

    • @HVACGUY
      @HVACGUY  ปีที่แล้ว +2

      There’s no way to check the oil without draining it all and measuring. Did you hear it once I got it started?

    • @browntigerus
      @browntigerus ปีที่แล้ว

      @@HVACGUY Sounds like vertical shaft wabbles and the core touches something....

    • @Jeff_S...
      @Jeff_S... ปีที่แล้ว

      @@HVACGUY If this were me, I would ballpark estimate that cap to be 45/5, maybe 45/7.5. I duno how old this thing is, but that looked like one of the old indestructible plastic housing capacitors. And while we do trust them, I just can't see one that over spec still being in service.

  • @SWBoeing
    @SWBoeing ปีที่แล้ว

    that sound= compressor let go= $$$$$$$$$$ out of your piggy Bank better hope thy have the Money to get it replaced

  • @georgerockwell-z3c
    @georgerockwell-z3c ปีที่แล้ว +1

    Just another hack with fancy tools

    • @donnyberger3447
      @donnyberger3447 ปีที่แล้ว +4

      Yep, just another hack, LOL bet you would call this hack if you needed him.
      Just plain Ignorance on your part.