  • In this video, I am connecting terracotta clay pipe to pvc pipe. Both of the pipes are 3 inch, but the clay pipe has a 0.5 inch wall thickness vs the pvc wall thickness of 0.25 inch. A 3 inch clay to 3 inch pvc coupler steps from 3.5 inches to 4 inches. The coupler that I used was a fernco P1059-33 (amzn.to/2J1daLk). You could also use a no hub coupler for an underground or over ground application like this.
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 26

  • @JSLEnterprises
    @JSLEnterprises 3 ปีที่แล้ว +10

    For under slab, 'No-Hub' stainless sleeved couplers is what is required by code, all over Canada and the USA. The coupler you used is not meant for below slab. It should only be used in above ground, unfinished areas that are easily accessible.

    • @ryanknuth6915
      @ryanknuth6915 2 ปีที่แล้ว +1

      Yes a shielded fernco! Minimum 4inch under ground

    • @nnoor9059
      @nnoor9059 2 ปีที่แล้ว

      What is needed for under slab? Thanks

  • @frankconolly1807
    @frankconolly1807 ปีที่แล้ว

    P1059-33 saved my ass. Thanks.

  • @outofideas4aname
    @outofideas4aname 2 ปีที่แล้ว

    Why do you put gravel in?

  • @mytravelvlog4593
    @mytravelvlog4593 4 ปีที่แล้ว +1

    The size of my terra-cotta is 4 inches that I will connect to 4 inches pvc pipe do they have those size for rubber boots

    • @CoolStuffGuysLike
      @CoolStuffGuysLike  4 ปีที่แล้ว +1

      Is it 4 inches on the inside diameter or th outside diameter? A 4 inch Terra Cotta pipe should have a 5 inch outside diameter. There is a 4 inch clay to 4 inch PVC available on Amazon www.amazon.com/dp/B0009VUOTW/ref=cm_sw_r_sms_apa_i_JAz8DbA3R9079 . You can look around and search 4 inch clay to 3.5 or 3 inch PVC also if you want a smaller trap. I have a link in the description for a 3 inch clay to 3 inch PVC, which is 4 inches to 3.5 inches actual coupler dimensions.

  • @artrivas5739
    @artrivas5739 3 ปีที่แล้ว

    Why having a P-trap main pipe since the toilet, sink, shower will have p-trap also?

    • @ryanknuth6915
      @ryanknuth6915 2 ปีที่แล้ว

      Every house should have a “house trap” (minimum 4inch) on the building drain. It helps sewer gas from getting in your house

    • @leonmorris5602
      @leonmorris5602 ปีที่แล้ว

      Also should be lowest cut riser in drain so if drain blocks up it come out of the trap instead of your floor trap in shower or something, it should be outside u der a tap search up org overflow relief gully

  • @Mr2pint
    @Mr2pint 3 ปีที่แล้ว

    are those clay pipe called orangeburg sewer pipes?

    • @capoBon
      @capoBon 2 ปีที่แล้ว

      No they are not the same material

  • @adnaanahmed3863
    @adnaanahmed3863 4 ปีที่แล้ว

    Is there a way of connecting internally, instead of rubber pipe connecting from outside, can it be connected inside. The pipe i need to connect is under a brick wall and would be impossible to connect the rubber connection over as i would need to remove bricks

    • @RoyArrowood
      @RoyArrowood 4 ปีที่แล้ว +1

      If you connect it internally that would reduce the capacity of the pipe I would think. I'm no plumber but it sounds to me like you may want to call one

  • @sakiloki4618
    @sakiloki4618 3 ปีที่แล้ว

    what is the normal size for clay pipe, its bigger then 4 inch

  • @leec8573
    @leec8573 2 ปีที่แล้ว +1

    What did you use to cut the clay pipe

    • @rosavito1
      @rosavito1 7 หลายเดือนก่อน

      I have the same question. did you figure that out?

    • @leec8573
      @leec8573 7 หลายเดือนก่อน

      @@rosavito1I got a diamond blade from Home Depot. In expensive

  • @mytravelvlog4593
    @mytravelvlog4593 4 ปีที่แล้ว

    Nice videos, where can you buy those rubber boots

  • @johnnyramirez1958
    @johnnyramirez1958 3 ปีที่แล้ว

    Google play Pandora

  • @gregramos6798
    @gregramos6798 3 ปีที่แล้ว

    what the heck . remove that freaking total house trap-all, each fixture in your house already has traps..out-dated plumbing

    • @CoolStuffGuysLike
      @CoolStuffGuysLike  3 ปีที่แล้ว +4

      This is for a floor drain, so it needs a trap since I don't have a whole house trap. The whole reason I could tell my trap had failed was because I could smell sewer gas in the basement.

    • @JSLEnterprises
      @JSLEnterprises 3 ปีที่แล้ว

      @@CoolStuffGuysLike Your floor drain shouldn't connect to the 'poop' sewer. The floor drain should only connect to your weeping tile drainage system (considering its clay and you dont have a sump pump, its probably also tied directly into the cities storm sewer)

    • @SpringIsBACK
      @SpringIsBACK 3 ปีที่แล้ว

      @@JSLEnterprises Plenty of places, like mine, don't have storm sewers - they just have ditches for rainwater. If in a flat area, the floor drain can only go one place...

    • @user-kj6jm1yq4d
      @user-kj6jm1yq4d 6 หลายเดือนก่อน

      Usually, floor drains go to the city sewer not the storm sewer.