  • 3 HVAC Service call variety pack of calls I ran recently. If you like a mix of broken equipment then this video is for you. If you enjoyed it or if you didn't please let me know down in the comments. Thanks for watching!
    - Purchase your tools at www.trutechtools.com/?AffId=42 and use the offer code SURVIVAL to save 8% on your total purchase (exclusions apply) -
    - TOOLS I USE -
    kit.co/hvacrsurvival
    KNIPEX Tools - 10" Pliers Wrench amzn.to/3U7RRJf
    KNIPEX Tools - 10" Cobra Water Pump Pliers amzn.to/3Wje8Wn
    Knipex Tools - Mini Pliers in Belt Pouch amzn.to/3WguyyH
    KNIPEX Tools - 4" Cobra XS Water Pump Pliers amzn.to/3UaQiKA
    Bahco -6" Wide Mouth Adjustable Wrench amzn.to/3sHIsMV
    Bahco - 8" Big-Mouth Adjustable Wrench with Rubber Handle - amzn.to/3SPhDB7
    Knipex - 9.5-Inch Ultra-High Leverage Lineman's Pliers amzn.to/3DTLJ2h
    Klein Tools Diagonal Cutting Pliers with Angled Head - amzn.to/3zuBVJb
    Klein Tools Stripper, Crimper Tool - amzn.to/3gQQ6Su
    Klein Tools Wire Cutter and Wire Stripper - amzn.to/3Fs627W
    Klein Tools Kurve Wire Cutters, Heavy Duty Wire Stripping Tool - amzn.to/3FseIuW
    Klein Tools Heavy Duty Automatic Wire Stripper - amzn.to/3SQdZab
    Klein Tools Crimping and Cutting Tool - amzn.to/3TPIgXU
    Klein Tools Screwdriver Adjustable 4 to 8-Inch amzn.to/3Nl6KWz
    IDEAL INDUSTRIES Digital Circuit Breaker Finder - amzn.to/3DoBFwm
    Fluke 376FC AC/DC Clamp Meter with iFlex - amzn.to/3UaNyx2
    Fluke 62 Max Industrial Infrared Thermometer - amzn.to/3SNdwWg
    Fluke 902 FC HVAC True-RMS Clamp Meter - amzn.to/3Ws7OfB
    Fluke 87V MAX - amzn.to/3U6Rlv9
    Fluke Networks Pro3000 Tone Generator - amzn.to/3WedklG
    Fluke - FLUKE-52 Dual Input Digital Thermometer amzn.to/3zwFdf1
    Ideal Safe-T-Grip Fuse Puller - amzn.to/3zsw2w4
    Klein Tools Canvas Zipper Bag - amzn.to/3WgnJxq
    Uni-Paint PX-20 Oil-Based Paint Marker - amzn.to/3sE3R9T
    5 Gallon Bucket Topper and Organizer - amzn.to/3sGi2Ll
    Stabila Magnetic Pocket Level PRO with Holster - amzn.to/3FtYLo0
    Clip & Carry Kydex Multitool Sheath for LEATHERMAN SURGE - amzn.to/3TPJfHA
    Kydex Multitool Sheath for LEATHERMAN WAVE & WAVE + PLUS - amzn.to/3sJlhlg
    Cooper Atkins Thermistor Thermometer - amzn.to/3DLeHkC
    GEARWRENCH Internal/External Ratcheting Puller 7 Ton 2 or 3 Jaw - amzn.to/3FxTU5l
    💥 Amazon Store: www.amazon.com/ref=as_li_ss_t...
    - CONTACT INFO -
    hvacrsurvival@gmail.com
    - FOLLOW ME -
    Instagram - / hvacrsurvival
    Facebook - / hvacrsurvival
    - SUPPORT THE CHANNEL -
    www.paypal.me/RickDirmeyer
    Warning Notice Disclaimer - Video content listed on the channel HVAC*R Survival is for entertainment purposes only and not meant to be a substitute for not contacting a competent HVAC/R PROFESSIONAL. Do not attempt anything said or seen on my videos, The tasks that are shown are dangerous and deadly without proper training.
    This page contains affiliate links, which means that if you click on the link and make a purchase, I’ll receive a small commission. HVAC/R Survival is a participant in the Trutechtools, Fenix-Store & Amazon Services LLC Associates Program.
    #hvacrsurvival #hvaclife #hvacservice #hvacr #refrigeration #troubleshooting
    00:00 TruTechTools.com
    00:17 Hoshizaki Ice Machine No Ice
    00:35 How to remove ice from machine for dummy's
    02:39 Looking Deep For The Big Ice Breaker
    03:28 On Call Walk In Cooler Warm
    03:49 Check cooler thermostat operation
    04:10 Found the condenser and the problems
    05:05 Electricians don't know how to wire a defrost clock
    06:06 How defrost clock works
    06:41 Check Solenoid valve wiring
    10:03 how a cooler defrost clock works from the inside
    12:18 How to start and install a cooler
    13:01 reach in cooler is warm
    13:35 use your ears to diagnose your problem
    14:28 use your sense of touch to diagnose the compressor
    16:10 checking start components
    17:20 good idea to add a bleed resistor to help protect the start relay
    18:20 moment of truth
    19:55 annie compressor start tool in action
    21:13 will bypassing the start components work?
  • บันเทิง

ความคิดเห็น • 55

  • @zaccody6980
    @zaccody6980 ปีที่แล้ว +5

    And this is why you never trust a disconnect! Great video Rick

  • @scotts4125
    @scotts4125 ปีที่แล้ว +7

    Great job keeping yourself safe. I can see a lot of people missing that.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +3

      I'm just glad it wasn't our electricians. But at least we caught it. Thanks for checking it out👍👍

  • @atch_n_sons
    @atch_n_sons ปีที่แล้ว +1

    I love correcting sparkies work!

  • @sterlingarcher46
    @sterlingarcher46 ปีที่แล้ว +6

    Like you said : and they're worried about us wiring things up 😅
    Reminds me of a couple months ago , my company insisted on hiring a so called electrician to replace bus bars and stuff like that on a chiller , the dude messed things up so bad I had to call my manager and tell him : " yeah I'm not starting this thing up until the job gets re-done from the start , no way I'm commissioning that sh*t show " 😂

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Bingo. Boom... drop the the hammer 😁👍👍

  • @retsbew8954
    @retsbew8954 ปีที่แล้ว +2

    I keep watching, you teach, I learn. Rinse and repeat! Great job!! I appreciate all the great content 👊🏻

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      Thanks to much🙏🤜🤛👍👍

  • @FerralVideo
    @FerralVideo ปีที่แล้ว +2

    Good selection of calls. I honestly like the soft background music you've added. Enough to fill in the dead air without distracting in any way.
    Good catch on the electrical SNAFU as well. Put 240 on a 120 device and you'll have a bad day.
    Surprised it lasted as long as it did!

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      That was actually a performer practicing in the background, that wasn't a track that I added 🤭 but thanks for the compliment. 👍👍

  • @MariosACandRefrigeration
    @MariosACandRefrigeration ปีที่แล้ว +2

    thanks for sharing.I would cut and check capillary before quoting the compressor.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +2

      We replace the capillary tube every time we replace the evaporator. That's why we don't mess with it at that time.

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC ปีที่แล้ว +1

    Nicely done Rick. As always

  • @johnwalker890
    @johnwalker890 ปีที่แล้ว +2

    Good job Rick. You win some you lose some.

  • @manhpham8052
    @manhpham8052 ปีที่แล้ว +1

    thorough troubleshooting and well explanation for the newbie like me. Thanks for the video.

  • @thesilentonevictor
    @thesilentonevictor ปีที่แล้ว +1

    Great troubleshooting Rick

  • @14312KIDS
    @14312KIDS ปีที่แล้ว +1

    That is very unusual for a hoshi plate to do that. but you nailed it.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      That's what happens when you use Manitowoc cleaner in a Hoshi machine. And vise a versa when you use Hoshi cleaner on a nickel plated plate.

  • @harrydickson4575
    @harrydickson4575 ปีที่แล้ว +2

    Great job 👍👍👍

  • @Eddy63
    @Eddy63 ปีที่แล้ว +1

    Nice catch on that electrical screw -up ... Your vids are always interesting and educational ... Thx for helping the young'ens ...

  • @chainoflakesrefrigerationa2906
    @chainoflakesrefrigerationa2906 ปีที่แล้ว +1

    Very nice

  • @jeffgrant6914
    @jeffgrant6914 ปีที่แล้ว +1

    Good video 👍 buddy

  • @crg061
    @crg061 ปีที่แล้ว +2

    Why would they call you to fix a Pepsi cooler when Pepsi does it for free ? Unless it’s a stolen cooler, lol

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +3

      Pepsi gives these stores the coolers if they purchase the drinks from them, after a certain amount of time the cooler is there's to keep.

    • @hvac01453
      @hvac01453 ปีที่แล้ว +2

      @@HVACRSurvival around here if you buy pepsi products, they are responsible to maintain the equipment, but you cant have coke products in there as well. Thats the catch.

  • @shine-cg9uf
    @shine-cg9uf ปีที่แล้ว +1

    💪👍🇺🇸❄ nice troubleshooting. Gin n juice baby!!

  • @DedmenMiller
    @DedmenMiller ปีที่แล้ว +1

    On jobs like that last compressor, where you put in a new cap only to find the compressor is dead. What do you do with the cap? Do you take it back and put the old one back in, or do you bill the customer for it?

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      I put it back on the truck. There's nothing wrong with the capacitor that's why I don't destroy the box until I'm completely done and even then I use it to make sure I get a replacement. Not every company is a bunch of shysters out there. 😁

  • @jasonsharp4518
    @jasonsharp4518 ปีที่แล้ว

    That’s what they get for stealing that cooler , Pepsi would swap it out for free.

  • @zekenzy6486
    @zekenzy6486 ปีที่แล้ว +1

    Great Video. Thank you for sharing. What's selenoid ? and what's selenoid does in HVAC-R

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      I don't understand the question, are you asking what does the solenoid do? If so, the solenoid stops the refrigerant flow when the thermostat is satisfied causing the refrigeration system to pump down and shut off.

    • @zekenzy6486
      @zekenzy6486 ปีที่แล้ว +1

      @@HVACRSurvival Thank you. How do we know if selenoid is bad and need to replace new one ? how to do diagnose selenoid ?

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      If it's powered and not opening or it's restricted then it's bad

  • @George-if4cl
    @George-if4cl ปีที่แล้ว +2

    Does this walk in cooler has 2 solenoids or just one and what is thermostat doing if there is only one solenoid since that defrost timer kills the power to the solenoid that you rewired ? Great video Rick. Cheers

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +2

      It only has one solenoid, the defrost clock sends power to the thermostat, the thermostat sends power to the solenoid. Whether the thermostat is satisfied or the defrost clock goes into defrost the result is the same, the solenoid is de-energized the refrigerant system continues to run until the suction pressure drops down low enough that the low pressure switch breaks power to the contactor shutting the system off.

    • @George-if4cl
      @George-if4cl ปีที่แล้ว +1

      Thanks for answer. Was confused that defrost timer just controls solenoid by condensor but now its perfectly clear. Cheers

  • @commenter5469
    @commenter5469 ปีที่แล้ว +1

    Can’t find 175/300 volt transformer for my Anny. Can you point me to the right places to look for one?

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      I'm not sure where you're going to get that. All I have is the schematic.

    • @commenter5469
      @commenter5469 ปีที่แล้ว +1

      Thanks anyway.

  • @tphvac87
    @tphvac87 ปีที่แล้ว +1

    😂 why does it say use bare hands no gloves in In machine that seems unsanitary? Nice work tho man! What type of fungus or mushroom is growing In that drip pan of that Pepsi cooler? I don’t do refrigeration mostly residential HVAC just curious…that’s bizarre looking?

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      The ice machine was in a factory where the employees weren't mindful🤦🏻. Some people just don't think😳. I'm not sure what the heck that thing was in the pan, it looked like it was man made but was likely some growth 🤣.

    • @throttlebottle5906
      @throttlebottle5906 ปีที่แล้ว +1

      they probably have on work gloves full of nasty things, etc. in which case clean hands would be better than filling the ice bin with whatever.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Bingo

  • @hvac01453
    @hvac01453 ปีที่แล้ว +2

    not sure if you picked up on it BUT.... That Paragon Timer was a 120 Volt defrost timer on a 220V circuit. Im suprised it ran at all. The electrical issues went far beyond the disconnect. The point to reiterate should have been to match the voltages when you replace equipment, not with what was there before, but rather what do I have as a power supply. I do like your videos.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +4

      I'm not sure you understood that I was pointing that out? It was a 230 volt circuit and that's what the condenser runs on and that's what the clock should have been. Other than the clock motor being the wrong voltage there's no difference between the two different defrost clocks. The mechanical gearing and the switches are exactly the same.

    • @hvac01453
      @hvac01453 ปีที่แล้ว +2

      @@HVACRSurvival willthe switch8ng work, sure... but the clock won’t.

    • @hvac01453
      @hvac01453 ปีที่แล้ว +1

      @@HVACRSurvival l know, it still kills the component.

  • @steveblake8766
    @steveblake8766 ปีที่แล้ว +1

    341 Thumbs uP