Sanitary and Vent Piping for Beginners in Revit MEP

แชร์
ฝัง

ความคิดเห็น • 29

  • @mep_guy
    @mep_guy  2 ปีที่แล้ว +1

    Get my FREE Plumbing in Revit mini-course:
    www.mepguy.com/

  • @thedude8009
    @thedude8009 ปีที่แล้ว +2

    You've saved me a bunch of time and headache. I'd buy you a couple beers if I could!

    • @mep_guy
      @mep_guy  ปีที่แล้ว

      I'd definitely take you up on that!

  • @mrferdie583
    @mrferdie583 ปีที่แล้ว +1

    thanks for this video!!

    • @mep_guy
      @mep_guy  ปีที่แล้ว

      You are very welcome! I go way more in depth in my courses.

  • @anthonykeller6739
    @anthonykeller6739 2 ปีที่แล้ว +2

    Thanks for the videos. Do you have any Sanitary piping videos that shows working piping and fittings with "sloped" piping? I have found that drawing piping is much easier with no slope added. SAN piping has to be sloped or doesn't work.

    • @mep_guy
      @mep_guy  2 ปีที่แล้ว +2

      Yep, I did a whole video on sloped piping. Hope you enjoy it!

    • @anthonykeller6739
      @anthonykeller6739 2 ปีที่แล้ว

      @@mep_guy Thanks!

  • @XeshanMalix
    @XeshanMalix 2 ปีที่แล้ว +1

    Thanks for such a great video again!!! Sir can we use two seprate pipes for waste drainge and Soil Waste Separately???

    • @mep_guy
      @mep_guy  2 ปีที่แล้ว

      You can do anything in Revit. My question would be why do you want to do such a thing. Do you want to use two different pipes for tagging purposes?

    • @XeshanMalix
      @XeshanMalix 2 ปีที่แล้ว

      @@mep_guy We practice two pipe sanitary system. One pipe collects the foul soil and water closet wastes, and the second pipe collects the water from the kitchen, bathrooms, house washings, etc. But i didnt see a single video on Two Pipe Sanitary system.

    • @mep_guy
      @mep_guy  2 ปีที่แล้ว

      @@XeshanMalix Ok I can help you out. You just need to create another system for your second sanitary system. Watch my video called "customize Line Patterns" and go to the 5:30 mark. Do this same process but with sanitary pipe. Duplicate it and name it whatever you call that secondary sanitary system. You can change the color and tag id like I did in the video. Hope that helps!

    • @XeshanMalix
      @XeshanMalix 2 ปีที่แล้ว

      @@mep_guy Thanks alot!!!

  • @pmarkpmark
    @pmarkpmark 2 ปีที่แล้ว +1

    @10:19 could you explain more. I have a fitting like you said, but it changes my whole system type.

    • @mep_guy
      @mep_guy  2 ปีที่แล้ว

      First which version of Revit are you using? You have to separate the entire piping system from the sanitary first. So everywhere you are connected needs to be separated like I show @8:54 then once it's all separated you should be able to change the system to vent. Then re-attach to the sanitary. As long as there is a fitting separating the systems you should be good.

    • @pmarkpmark
      @pmarkpmark 2 ปีที่แล้ว

      @@mep_guy it's the 2023 version

    • @mep_guy
      @mep_guy  2 ปีที่แล้ว

      @@pmarkpmark I have a feeling it's because piping is still connected. Also when you make the connection it needs to be into a fitting. Not sure if this is required, but could be causing your system switch.

  • @oulafatla8686
    @oulafatla8686 ปีที่แล้ว

    Hi, thank you for sharing this. Do you have a tutorial video about adding a storage tank on roof? I can't find a tank in revit library

    • @mep_guy
      @mep_guy  ปีที่แล้ว

      You can easily create one. I'd recommend learning how to create your own families. A tank is very easy to create. I create a tank water heater in my course. Sounds like you might benefit from it.

    • @oulafatla8686
      @oulafatla8686 ปีที่แล้ว

      @@mep_guy thank you for your reply, can u plz share the link here? Thank you.

    • @mep_guy
      @mep_guy  ปีที่แล้ว

      @@oulafatla8686 My course is available at:
      www.mepguy.com

  • @egmelaku
    @egmelaku 2 ปีที่แล้ว

    🙏Thanks for this helpful tutorial. I want to change the calculation option in Revit ......
    (Path =>
    1. Systems(tab) ->
    2. Mechanical Settings ->
    3. Pipe Setting ->
    4. Calculation ->
    5. Flow(tab) ->
    6. Calculation Method)
    ...... from "the 2012 International Plumbing Code (IPC) Table E103.3 (3)" to custom fixture flow rate/table.
    👉 How would you advice me, please?
    Thanks!

    • @mep_guy
      @mep_guy  2 ปีที่แล้ว +1

      Revit cannot do sanitary flow calculations. You can only use the IPC method to convert fixture units to gpm for water flow in pipe.

  • @valeriepierre7297
    @valeriepierre7297 2 ปีที่แล้ว +1

    (@7:49) when the fitting is drawn the wrong way, click the blue arrow that appears when you select it and it will flip it.

    • @mep_guy
      @mep_guy  2 ปีที่แล้ว

      Thanks for the tip Valerie. Unfortunately with the wye fitting you actually can't just flip the fitting in that scenario. At least I don't think you can lol. It's a very strange phenomenon and has to do with which way the fitting is drawn. But thanks for helping me out!

    • @valeriepierre7297
      @valeriepierre7297 2 ปีที่แล้ว +1

      ​@@mep_guy Thank you for the videos, I have an architectural background and new to Revit MEP. Your videos have been soooo helpful I watch them religiously. Do you have videos on the other disciplines (electrical & mechanical) as well?

    • @mep_guy
      @mep_guy  2 ปีที่แล้ว +1

      @@valeriepierre7297 that's so awesome! I'm glad you are learning the other trades. I see a very bright future. My plan is to do plumbing first then create mechanical videos. Eventually I'll learn electrical but that's a ways away.

  • @subhanqaz5700
    @subhanqaz5700 2 ปีที่แล้ว

    Kindly make a vedios on HVAC works also I have learnt a lot from your channel.

    • @mep_guy
      @mep_guy  2 ปีที่แล้ว

      I will soon! Working on my plumbing course but I'll be sure to do some HVAC in the future!