Training - M221 - M16.4 Homing Modes PTO

แชร์
ฝัง
  • เผยแพร่เมื่อ 11 พ.ค. 2022
  • Training - M221 - M16.4 Homing Modes PTO
    Example Project:
    schneider-electric.box.com/s/...
    The software EcoStruxure Machine Expert Basic (former SoMachine Basic) allows you to program the Modicon M221:
    www.se.com/ww/en/download/doc...
    The software EcoStruxure Machine Expert Basic is Free, you need to have an account in our License Portal in order to register it:
    www.se.com/ww/sites/corporate...
    In order to program the Modicon M221 you can use a miniUSB cable (TCSXCNAMUM3P or BMXXCAUSBH018).
    Playlist of the training:
    • Modicon M221 - Training
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 11

  • @abc-pe7iq
    @abc-pe7iq 2 ปีที่แล้ว +1

    Tank you for all videos. I belive continue these videos. Continue Please ...

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  2 ปีที่แล้ว

      Hi there! I will continue with this topic of PTO and more 😁

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  2 ปีที่แล้ว

      Example project for homing in the description

  • @HuyBom9010
    @HuyBom9010 10 หลายเดือนก่อน +1

    Thank you so much, you are very handsome 😅😅

  • @ahmedabdelraouf6638
    @ahmedabdelraouf6638 2 ปีที่แล้ว +1

    Thanks for the videos.
    Can you share the program?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  2 ปีที่แล้ว +1

      Thanks Ahmed! I will share the final program in the video with the implementation with a Lexium32 (i still have a few things to adjust 😬)

  • @abdellahbazmat9508
    @abdellahbazmat9508 2 ปีที่แล้ว +1

    could you plz explain Modbus TCP for M172 in order to read registers

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  2 ปีที่แล้ว

      Hi Abdellah! It’s been a while since i do not upload any content related to M172 i will need to work on that.
      Anyway, the registers are “created” on the configuration depending on the type of variable status or eeprom then on the bios parameter you will need to activate the eth port (check the default values to enable it) and configuration of the network.

    • @abdellahbazmat9508
      @abdellahbazmat9508 2 ปีที่แล้ว +1

      ​@@LeTomasAHUMADA to active the eth port, i have to give him 502 or the default value 65535? there is a way to share you what i did (mail for example), because i have just a problem in the configuration!! PLZ

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  2 ปีที่แล้ว

      @@abdellahbazmat9508 you can enter the 502. If you need to read info from the m172 try in the master add or subtract one to the register probably is that because is very straight forward to read/write info from the m172.
      I wont be available until next tuesday so i recommend you to contact the schneider technical support team in your country to sort this out quickly.