Centrifugal Pump Sizing Calculation: RPM - FLOW RATE - HEAD PRESSURE - POWER - IMPELLER DIAMETER

แชร์
ฝัง
  • เผยแพร่เมื่อ 4 ก.พ. 2025

ความคิดเห็น • 60

  • @Jaescompany
    @Jaescompany  4 ปีที่แล้ว +4

    Watch the ITALIAN VERSION HERE: th-cam.com/video/_sqhov49X-c/w-d-xo.html

  • @connorm2268
    @connorm2268 ปีที่แล้ว

    This is already a confusing topic for people, so please correct the impeller direction at time 2:05. Others than that this video was well done. Thank you for posting.

    • @Industrial_Mechanic
      @Industrial_Mechanic 10 หลายเดือนก่อน

      Good Catch. I also saw that, but maybe only for animations purposes...

  • @borinvlogs
    @borinvlogs 4 ปีที่แล้ว +3

    We don't need to change anything or do calculations, but it is good to know how to calculate. Thank you! 😊

    • @Jaescompany
      @Jaescompany  4 ปีที่แล้ว +1

      Thank you so much for your comment! If you're interested you can also watch our video about Thermal power plant th-cam.com/video/Ht2wgH_EWQU/w-d-xo.html We would like to know your opinion about it. If you want to learn more about our projects, please visit our website www.jaescompany.com/

    • @rejvimohan2387
      @rejvimohan2387 3 ปีที่แล้ว

      @@Jaescompany and lk lol k9lllllllloililol opp pppou

  • @bahriakyildiz3054
    @bahriakyildiz3054 11 หลายเดือนก่อน

    Thanks a lot dear
    Useful information

  • @7world_eyes702
    @7world_eyes702 3 ปีที่แล้ว

    Today I was find this circulation .and I found this video . So learnt from this video.thanks sir

  • @danechristmas6570
    @danechristmas6570 4 ปีที่แล้ว +1

    Thanks for the formulas, it helped me a lot in designinging my system

    • @Jaescompany
      @Jaescompany  4 ปีที่แล้ว +1

      Glad to hear it from youl!! Have you had a chance to watch our videos about SUBMERSIBLE PUMPS th-cam.com/video/5bXNd_XUTp0/w-d-xo.html We would like to know your opinion about it. If you want to learn more about our projects, you can subscribe to our channel th-cam.com/channels/b7TkWFn3nyb6XhudxGu5tw.html and visit our website www.jaescompany.com/

    • @bodhisatyaguha3248
      @bodhisatyaguha3248 3 ปีที่แล้ว

      Please let know the formula of finding the horse power of pump.

  • @Jaescompany
    @Jaescompany  4 ปีที่แล้ว +2

    thanks inside web team for this new video

    • @dhansam4557
      @dhansam4557 4 ปีที่แล้ว

      James company could you reply the question below for Fabio Clavenna which is to me a very important question. Thanks.

  • @5afbi
    @5afbi ปีที่แล้ว

    nice video 🤗

  • @chautung2007
    @chautung2007 2 ปีที่แล้ว

    Very useful content, many thanks

  • @GauravSharmaengineer
    @GauravSharmaengineer 4 ปีที่แล้ว +5

    The relation between flow rate and the Head you have mentioned needs to be checked as far as i know head is inversely proportional to flow rate. The characteristic curve for any pump suggests that at highest flow rate there will lowest head. Please correct me if am wrong

    • @sahiljaiswal2141
      @sahiljaiswal2141 4 ปีที่แล้ว

      That's correct. Maximum head is when the flow rate is zero.

  • @Saikiran-qb2yo
    @Saikiran-qb2yo 3 ปีที่แล้ว

    Magnificent content ☺️

  • @arun4846
    @arun4846 2 ปีที่แล้ว

    Superb thanks ❤️❤️❤️

  • @benjaminchapa4431
    @benjaminchapa4431 2 ปีที่แล้ว

    wonderful information !

  • @jumeenmohamed6589
    @jumeenmohamed6589 3 ปีที่แล้ว +1

    Are these formulas used to change the existing values what if need to first values?

  • @mk123ify
    @mk123ify 3 ปีที่แล้ว

    Thanks for the beautiful explanation of affinity laws. i think Power will be 50.4 HP instead of 54.3 HP in the second last case

  • @precisionsealingsolutions6627
    @precisionsealingsolutions6627 3 ปีที่แล้ว

    Excellent

  • @VishalKumar-xl2xd
    @VishalKumar-xl2xd 4 ปีที่แล้ว +2

    Sir these formulas are helpful in calculation of new value but sir how to calculate the original at the first time ( when we dont know the original ones)
    Suppose i need a air compressor to suck (1/2) kg of weight in a pipe then how i calculate the values ??

  • @chamunorwachibanguza7902
    @chamunorwachibanguza7902 2 หลายเดือนก่อน

    Can I use a diesel motor to run the centrifugal water pump

  • @narayanareddy4654
    @narayanareddy4654 3 ปีที่แล้ว +1

    can plz show submursible pumps

  • @shivaay3478
    @shivaay3478 4 ปีที่แล้ว +1

    Very knowledgeable thanksgiving

    • @Jaescompany
      @Jaescompany  4 ปีที่แล้ว

      Happy about it!! 😀😀 If you're interested you can also watch our videos about SUBMERSIBLE PUMPS th-cam.com/video/5bXNd_XUTp0/w-d-xo.html We would like to know your opinion about it. If you want to learn more about our projects, you can subscribe to our channel th-cam.com/channels/b7TkWFn3nyb6XhudxGu5tw.html and visit our website www.jaescompany.com/

  • @chamunorwachibanguza7902
    @chamunorwachibanguza7902 2 หลายเดือนก่อน

    Hie Sir, what is the meaning of these digits on a centrifugal pump 50-32-160.
    Thank you 🙏

  • @suzyans7819
    @suzyans7819 ปีที่แล้ว

    How did you calculate modified gpm???!

  • @yasmanelel6571
    @yasmanelel6571 5 หลายเดือนก่อน

    If we will compare with Power KW and L/s flow rate . What is constan nunber formula

  • @lilalali6753
    @lilalali6753 3 ปีที่แล้ว

    2:04 Whoa! Time machine. Back to the future.

  • @frejieberinguela5090
    @frejieberinguela5090 4 ปีที่แล้ว +1

    Thank yOu so much.

    • @Jaescompany
      @Jaescompany  4 ปีที่แล้ว

      Thanks to you. Pleasse watch our video about submersible pumps th-cam.com/video/5bXNd_XUTp0/w-d-xo.html We would like to know your opinion about it.
      If you want to learn more about our projects, you can subscribe to our channel th-cam.com/channels/b7TkWFn3nyb6XhudxGu5tw.html and visit our website www.jaescompany.com/

  • @dineshmistry1107
    @dineshmistry1107 2 ปีที่แล้ว

    How to calculate shut-off pressure in centrifugal pump?
    What is maximum suction lift height?
    In which type of Suction NPSH is important?

  • @saleman7019
    @saleman7019 4 ปีที่แล้ว +1

    That's good for us to learning

    • @Jaescompany
      @Jaescompany  4 ปีที่แล้ว

      Glad to be of help! If you're interested we made a video about SUBMERSIBLE PUMPS th-cam.com/video/5bXNd_XUTp0/w-d-xo.html We would like to know your opinion about it. If you want to learn more about our projects, you can subscribe to our channel th-cam.com/channels/b7TkWFn3nyb6XhudxGu5tw.html and visit our website www.jaescompany.com/

  • @isaacamaranolo2787
    @isaacamaranolo2787 4 ปีที่แล้ว +1

    Please sir do I need to change any thing in centrifugal pump to use it as turbine generator

    • @Jaescompany
      @Jaescompany  4 ปีที่แล้ว

      Hello. Nice question! Running a centrifugal pump in reverse rotation mode will, in certain conditions, create a turbine effect. This coud be an efficient method of generating energy as well as recovering energy and contributing to energy savings. If you're interested in this topic we recommend you to watch our video about SUBMERSIBLE PUMPS th-cam.com/video/5bXNd_XUTp0/w-d-xo.html If you want to learn more about our projects, you can subscribe to our channel th-cam.com/channels/b7TkWFn3nyb6XhudxGu5tw.html and visit our website www.jaescompany.com/

  • @fabioclavenna1103
    @fabioclavenna1103 4 ปีที่แล้ว +1

    Isn't there a relation between number & dimension of the blades on the impeller and the parameters ?
    I mean the larger the blades the more liquid it will pump and the more power it will require so the less the number of blades the less liquid it will pump and the more rpm are required to achieve the same efficiency

  • @bowenratter241
    @bowenratter241 4 ปีที่แล้ว +1

    why do we square the values in some of the equations?

    • @Jaescompany
      @Jaescompany  4 ปีที่แล้ว +4

      Hello. Thank you so much for your question! To find New Head Pressure when we want to chance the RPM, in this case we have to square both original and modified RPMs. RPM is related to shaft speed and if we look at the second affinity law: "Head is proportional to the square of the shaft speed". We hope will be of help. Have you had a chance to watch our videos about SUBMERSIBLE PUMPS? th-cam.com/video/5bXNd_XUTp0/w-d-xo.html We talk about CAVITATION and we would like to know your opinion about it. If you want to learn more about our projects, you can subscribe to our channel th-cam.com/channels/b7TkWFn3nyb6XhudxGu5tw.html and visit our website www.jaescompany.com/

  • @suhandirizkihidayat454
    @suhandirizkihidayat454 3 ปีที่แล้ว

    Affinity's Law

  • @srinumaradana9971
    @srinumaradana9971 3 ปีที่แล้ว

    How to find out CFM calculation. With example

  • @electricbrain1736
    @electricbrain1736 4 ปีที่แล้ว +1

    Hi... Can you help me choose a pump for a project..... I need inlet diameter, rpm and pleasure that will give me 100bar at 8 smaller outlet

    • @Jaescompany
      @Jaescompany  4 ปีที่แล้ว

      Sure! Where are you from sir? Have you had a chance to watch our video about SUBMERSIBLE PUMP? th-cam.com/video/5bXNd_XUTp0/w-d-xo.html We would like to know your opinion about it. If you want to learn more about our projects, you can subscribe to our channel th-cam.com/channels/b7TkWFn3nyb6XhudxGu5tw.html and visit our website www.jaescompany.com/

  • @حمديالزرقي
    @حمديالزرقي 2 ปีที่แล้ว

    But I need a computer program for accounts because I am a student at the university, Please

  • @Ahmadnaweed786
    @Ahmadnaweed786 3 ปีที่แล้ว

    How do you convert ftH2O to kpa?

  • @uppulurisri8072
    @uppulurisri8072 4 ปีที่แล้ว +1

    Hi
    Can understand the formulas and substitute
    But how do you get the modified gpm instead of orginal gpm?
    Can you explain that

    • @suzyans7819
      @suzyans7819 ปีที่แล้ว

      I'm also wondering about the same thing, how did he calculate the modified gpm and used it in formulas

  • @EAR.Pakistan
    @EAR.Pakistan 11 หลายเดือนก่อน

    You may right becoz the it is matter of Facts. But, by 1st thought the relation of Flow and Head seems wrong. If we increase the head the flow will be lessen, it means as head is inversely proportional to flow. In this thought your explanation needs more to elaborate.

  • @suresharnsuresha2789
    @suresharnsuresha2789 4 ปีที่แล้ว +1

    Dear sir, I need your help that, we run a centrifugal pump which is 22 kW motor head is 40 Meters, discharge is 140 cubic metres per hour and discharge pipe Dia is 6" of 385 metres long and 165 metres of 2"branch pipes.But the thing is we need 7020 ltrs per minute, actually it is 2330 ltrs per minute.so please help me regarding this matter to improve the quantity of water and suggest and send design calculation formulas, which is helpful for me in future.
    Thanks and with warm regards by
    SURESH R
    Maintenance manager
    Aradhya Steel Pvt Ltd
    India.

  • @Varunkm110
    @Varunkm110 4 ปีที่แล้ว

    You are saying affinity law .
    This every one knows.

    • @Jaescompany
      @Jaescompany  4 ปีที่แล้ว

      Dear Varun thank you for your opinion

  • @gaurawsharma7191
    @gaurawsharma7191 3 ปีที่แล้ว

    Hindi speaking please sir

  • @IfaaRaggaasaa
    @IfaaRaggaasaa 11 หลายเดือนก่อน

    Excellent