high ampere R600 gas /compressor... halinat alamin natin ang sira at ating gawin

แชร์
ฝัง
  • เผยแพร่เมื่อ 13 ม.ค. 2025

ความคิดเห็น • 90

  • @bernardquirona8640
    @bernardquirona8640 2 ปีที่แล้ว +1

    Master galing mo linaw mo mag paliwanag sana madami pa pang maupload n video good job master...thanks

  • @mybikevlogs6670
    @mybikevlogs6670 4 ปีที่แล้ว +3

    Nice info master

  • @josephcababat7376
    @josephcababat7376 7 หลายเดือนก่อน +1

    Salamat sir

  • @envision9201
    @envision9201 3 ปีที่แล้ว +1

    Thank you Sir , very informative..

  • @dadtechmech
    @dadtechmech 3 ปีที่แล้ว

    nice tutorial specially kung meron pang karga paano ubusin

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Boss for safety s r600 or r32 busan mo lahat ng valve sa ac low at high ganun din sa ref i cut mo mismo yung filter sa gitna para sumingaq sia and yunf sa access valve ng compressor then mga 30min ok na yun.wag mo lang gagawin is mag hinang para alisin tubo lalo me karga

  • @romeicernadura5671
    @romeicernadura5671 3 ปีที่แล้ว +1

    master ..sana marame ka pa maituro sa kagaya ko ngsisimula p lng pra mkapgyrabaho din ako sa inyo😁✌🏼

  • @jibrielbautista6767
    @jibrielbautista6767 3 ปีที่แล้ว

    thank you very much sir...request lang sir sana makagawa ka po ng video ng R290 refrigerant..

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Boss merun kami R299 unit kaso wala kami mabiln gas....

  • @romzlifeworkstv.6546
    @romzlifeworkstv.6546 4 ปีที่แล้ว +1

    Ito ang mga professional technician...ok na ok ang mga paliwanag at hindi binabalik sa dating technician ang mga problima ng unit..

  • @michaeljohnpalma2097
    @michaeljohnpalma2097 3 ปีที่แล้ว

    Salamat master

  • @michaeljohnpalma2097
    @michaeljohnpalma2097 3 ปีที่แล้ว +1

    Master puidi ka po mag blog wiring diagram ng water despenser

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Boss simple lanh diagram nya pero sige po pah me time ako gagawin natin

  • @romerovalin2635
    @romerovalin2635 4 ปีที่แล้ว +1

    Sir, request po. Side by side naman... 😊👍🙏 Salamat ser sa mga info. Ingat diyan sa angola. Salute.

    • @MrGerbee2
      @MrGerbee2  4 ปีที่แล้ว +2

      Sige boss basta po merun bakit hindi

    • @emanbuenaventura118
      @emanbuenaventura118 4 ปีที่แล้ว

      @@MrGerbee2 master ask kolang Po Sana paano Po icheck Yung capacitor Ng ref may takip Po kase sya e

  • @donatolapuz8031
    @donatolapuz8031 2 ปีที่แล้ว +1

    Pinaka safe na pagtanggal ng r600 sa system ay gawan mo ng paraan na ma vaccum bago ka mag hinang

  • @209rosalino_
    @209rosalino_ 3 ปีที่แล้ว

    Good job

  • @emmanuelvillanueva4515
    @emmanuelvillanueva4515 3 ปีที่แล้ว +1

    Nice video sir gerbee.keep safe.

  • @jhufilfernandez3739
    @jhufilfernandez3739 2 ปีที่แล้ว

    boss yung feezer na 6 layer na yelo normal ba na 2 amp pataas ang load

  • @ericthronicxz1377
    @ericthronicxz1377 3 ปีที่แล้ว +1

    ang masama master sa inverter limited lang ang mabibili mo spare parts ng electronic component? kaya mas marami technician ay change board agad ang findings👍

  • @Ibanez25145
    @Ibanez25145 2 ปีที่แล้ว +1

    Laht ba sir Ng inverter motor dpt napipigilan m?..SB nila kpg Ng high sped ska lmng mapipigilin kng ok pa .

    • @MrGerbee2
      @MrGerbee2  2 ปีที่แล้ว

      Panung napipigilan? If full speed yan dapat di mo mapigilan pero not means nun buo p sia... kasi mataas pressure nyan at malalaman mo lang pag gumamit ka gauge para malaman mo malakas paba pressure

  • @paomabini8506
    @paomabini8506 3 ปีที่แล้ว +1

    Paps paano magflushing ng refrigerator ng manual tnx

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว +1

      Same lang nmn sa lahat mapa ac or ref low side at high side pwede r22 tapos nitrogen or kahit 141b then nitrogen

  • @reynaldogaspar1553
    @reynaldogaspar1553 ปีที่แล้ว +1

    Sir gerbee bakit yung filter drier ngaun wala ng granule sa loob ok lang po ba yun.

    • @MrGerbee2
      @MrGerbee2  ปีที่แล้ว

      Ay diko alam bat wala hahahah alam ko kasi merun unless bago design.

  • @florencecapistrano4791
    @florencecapistrano4791 4 หลายเดือนก่อน +1

    sir mga ilang CFM ng vaccum pump ang pwede para sa ref?

    • @MrGerbee2
      @MrGerbee2  3 หลายเดือนก่อน

      @@florencecapistrano4791 boss kahit pinakamaliit pwede sa ref. Sa ac medyo malaki kya I bili ka pwede sa ref pwede sa ac pag malaki kasi bawas oras ka lng so pag maliit mas matagal.

    • @florencecapistrano4791
      @florencecapistrano4791 3 หลายเดือนก่อน +1

      @@MrGerbee2 salamat tlaga sir malaking tulong ka talaga sa akin, sa mahal kc ng labor mag diy n lng ako salamat talaga sa sagot sir ingat palagi and godbless po.❤❤❤❤

    • @florencecapistrano4791
      @florencecapistrano4791 3 หลายเดือนก่อน +1

      @@MrGerbee2 salamat sir gerbee dami kong natutunan sa inyo sir

  • @littleknowledge1984
    @littleknowledge1984 2 ปีที่แล้ว +1

    hello sir, meron po akong ice cube machine ang ampere po na naka indicate sa likod is 4.3 ampere..ngayon sinubukan namin e read umabot po ng 4.8 ampere..ok lang po ba yun?

    • @MrGerbee2
      @MrGerbee2  2 ปีที่แล้ว

      Ok lng po yun pero check mo yung coil ng condenser baka madumi or di makahinga yung ventilating nya nababarahan.

  • @kabalbasisla1871
    @kabalbasisla1871 4 ปีที่แล้ว +1

    Sir matanong kulang SA Aircon R32 ung Freon need ba nakataob ung tank pang charge freon

    • @MrGerbee2
      @MrGerbee2  4 ปีที่แล้ว +1

      Boss sa totoo lang po ako pag nag karga lagi nakataob lahat gas tinatayu ko lang pqg halos ok na pag tayu dagdag na lang

    • @kabalbasisla1871
      @kabalbasisla1871 4 ปีที่แล้ว

      @@MrGerbee2 Bo's Meron Lang ako tanong SA 404a ano po standing pressure at running pressure ..

    • @MrGerbee2
      @MrGerbee2  4 ปีที่แล้ว

      @@kabalbasisla1871 boss standing base sa chart is 180 -185 psi.at ang ruuning depende sa temp nya pero start moslt ng 80psi... base sa chart ako kasi lagi ako start sa mababa for satetylike 150 ako standing and running is 50 pag kulang saka ako magkarga..lahat ng gas lagi ako below standard or sa chart saka ako add on if alam ko kulang...

  • @edwardjosephalmodovar1254
    @edwardjosephalmodovar1254 3 ปีที่แล้ว +1

    sir gerbee ask ko lang saan service center ng midea......edward from grace park Caloocan. tnx

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Mam wala ako sinu service ng midea sa pinas po..frostlite ask nyo kasi parang nakita ko

  • @m2agapay369
    @m2agapay369 2 ปีที่แล้ว +1

    Boss pag flammable Ang freon ay dapat bang e release Yung freon sa system ? Kung di po flammable pwede Lang po ba mag hinang kahit may freon sa system?

    • @MrGerbee2
      @MrGerbee2  2 ปีที่แล้ว +1

      Hindi ka rin pwede mag hinang pag me gas ke flamable or hindi.. dahil pwede k maaksidente dahil me pressure sia

    • @m2agapay369
      @m2agapay369 2 ปีที่แล้ว

      @@MrGerbee2 sa nakikita ko sa ibang video po kapag may pinapalitan sila di nila vina vacuum . Diritso sila hinang TAs pinapalitan .pagkatapos po nilang palitan don na sila mag vacuum. Bad practice ba Yun po?

    • @MrGerbee2
      @MrGerbee2  2 ปีที่แล้ว

      @@m2agapay369 sa ref or ac last ang vaccium bago mag karga ng gas pag wala sila vaccium pwede rin tinatawag na self vaccium

  • @shielativar8293
    @shielativar8293 3 ปีที่แล้ว +1

    Sir idol tanung kulang po qng anu prob.ng compresor q. Sa unang saksak ng plug normal piro pag tinangal mo naugung nlng ang comp. At ngtrip ang comp. Tnx idol pasagot nmn po.

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Madami kasi pwedeng rason pwede comp pwedeng barado or capasitor... depende kasi sa ampere din

  • @alachambavlog2029
    @alachambavlog2029 3 ปีที่แล้ว +1

    Sir pag mataas ba Ang ampere malakas ba sa kuryenta

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Opo...same sa watts

  • @francisreyesjr7455
    @francisreyesjr7455 4 ปีที่แล้ว +1

    Flemable pla yan sir, paano sir kung e pinch off qn sir pag sarado qn ung access valve sir shempre e brazing qn nd kaya sasabog sir, pki sagot nmn sir,

    • @MrGerbee2
      @MrGerbee2  4 ปีที่แล้ว +1

      Boss pwede nmn maglagay ka access valve pra di kna mag pinch off..pwede if wala kna access valve pwede nmn pinch off ingatt lang ginagawa ko 3 pinch off para sure then habang hinangan ko sia nakakabit pa rin pinch off

    • @francisreyesjr7455
      @francisreyesjr7455 4 ปีที่แล้ว

      @@MrGerbee2 ah ok sir slamt sir ah, sir nag meseg aq sa mesnger mo sir, paki acept mo aq don sir pwde sir slmat sir

  • @melodygrace251
    @melodygrace251 3 ปีที่แล้ว

    kuya paki explain naman po ng english kuya salamat po ng marami god bless

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Mam sige po... ganito yan... how to test compressor or maybe high ampere because of one reason. Test alone the compressor and then check the ampere. Ex is, if your refrigeration is high ampere when is connected to unit, pipe not remove and still has gas inside and still high ampere.. you can test the compressor alone. Ex again you take 3 ampere before but after removing compressor in refrigerator and you test it alone and the ampere make normal below 1 ampere..means the high side of the system in tour refrigerator is clogged up. You need to clean the system (reprocess) and replaced filter and put new gas... barok pa ata mam hehehe

  • @edjohnmarkapostol1495
    @edjohnmarkapostol1495 4 ปีที่แล้ว +1

    Sir, ano po tawag dun sa defrost timer na connector?

    • @MrGerbee2
      @MrGerbee2  4 ปีที่แล้ว

      Ordinary connector boss pwede na basta insulated po..sorry late reply

  • @alexsup5237
    @alexsup5237 4 ปีที่แล้ว +1

    Master mangulit ako ulit tanong ko nakakabit pa sa sytem ang compressor ng ref. 1.9a, pagtanggal sa sytem ang comp. 1.4a okay lang ba ang compressor SALAMAT w8 ko reply mo master.

    • @MrGerbee2
      @MrGerbee2  4 ปีที่แล้ว +1

      Boss depende po..ganu ba kalaki compressor mo if frezzer na malaki pwede... pero if ref na pambahay hindi.. sira na yan pag ganyan kataas pero ref ng commercial at frezzer pwede

    • @alexsup5237
      @alexsup5237 3 ปีที่แล้ว

      Master 250g ang karga ng freon

    • @alexsup5237
      @alexsup5237 3 ปีที่แล้ว

      Malakas nman ang suction at discharge master

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      @@alexsup5237 boss depende sa unit.. nag base pa rin ako psi nya at amp

    • @alexsup5237
      @alexsup5237 3 ปีที่แล้ว +1

      Salamat master.

  • @alexsup5237
    @alexsup5237 4 ปีที่แล้ว +1

    Master 220v ang compressor

  • @killianveto.stephen.kamill5384
    @killianveto.stephen.kamill5384 3 ปีที่แล้ว

    Sir good evening...matanong ko lang, pag plug ko sa ref 4.24amp siya n dn nag trip off agad 1-2 second tinester ko yng Olp at relay ok naman...ano kaya dahilan sir nag trip off agad yong compressor pag plug mo? Salamat po aa sagot sir GOD BLESS po!!!!

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Posible po sira compressor mo kaya sia nag high amp...try nyo pong alugin or martilyo parang kakalugin nyo sia then wait 10mim saksak mo ulit pag ganun pa rin compressor mo sure stock up perp check mo capasitor

    • @killianveto.stephen.kamill5384
      @killianveto.stephen.kamill5384 3 ปีที่แล้ว

      @@MrGerbee2 kung ganon sir buy new compressor?

  • @mybikevlogs6670
    @mybikevlogs6670 4 ปีที่แล้ว +1

    Anong connection sa motor sir pag test Salamat

    • @MrGerbee2
      @MrGerbee2  4 ปีที่แล้ว

      Boss me relay at overload at capasirtor ako lagi ang testing

    • @MrGerbee2
      @MrGerbee2  4 ปีที่แล้ว

      Boss me relay at overload at capasirtor ako lagi ang testing

    • @jersonawiten9128
      @jersonawiten9128 4 ปีที่แล้ว +1

      Sana po yan po ituro nyo ..kahit walang board na gamit ..test lng kung ok ba compressor ..kadalasan kasi sira ung board .

    • @MrGerbee2
      @MrGerbee2  4 ปีที่แล้ว

      @@jersonawiten9128 yes boss me mga iba pako video dyan about nmn if sira board convert na lang basta non inverter

  • @jadztv6192
    @jadztv6192 3 ปีที่แล้ว +1

    Magkano singilan pag ganyan boss replacement ng compressor at reprocess?

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Boss diko na alam magkanu na singilan sa pinas..pero lagi mo i fix and service mo plus kung magkanu materyales either ikaw bili or customer

  • @jongbalicao3798
    @jongbalicao3798 ปีที่แล้ว +1

    Saan po location nyo sir?

  • @boybravo689
    @boybravo689 4 ปีที่แล้ว +1

    Master nakakasira sa ozone layer yang magpasingaw ka sa ere

    • @MrGerbee2
      @MrGerbee2  4 ปีที่แล้ว

      Yes boss... lahat nmn techncian nagagawa yan..kaya nga po nagpapalit ng gas sa refrigeration dahil hindi maiwasan yang ganyang scenario lalo na sa shop na tulas kong nasa 3rd country at lalo sa field na tech

    • @boybravo689
      @boybravo689 4 ปีที่แล้ว

      @@MrGerbee2 may mga bansa na estrikto pinagagamit na sila ng mga motor na pangevacuation ng refrigerant

  • @carlmiciano6121
    @carlmiciano6121 3 ปีที่แล้ว

    Sir asap po baka matulungan nyo ako bakit po yung ref namin nakailang palit na po ako ng overload protector nasisira po OLP sunog po at kainit ano po kaya problema?

    • @carlmiciano6121
      @carlmiciano6121 3 ปีที่แล้ว

      Asap po 😔need po namin ref gawa ng tatay may mga gamot na dapat nasa ref

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Sir pag nagpalit ka at nasisira pwedeng compressor na sia

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Pa check mo sa tech bakit ganun san ba loc mo baka me kilala ako

    • @carlmiciano6121
      @carlmiciano6121 3 ปีที่แล้ว

      Batangas po ako

    • @carlmiciano6121
      @carlmiciano6121 3 ปีที่แล้ว

      Sabi po ng iba defective compressor palitin na daw po

  • @wilmaenriquez1951
    @wilmaenriquez1951 2 ปีที่แล้ว

    High amphere pero walang buga ang compressor

    • @MrGerbee2
      @MrGerbee2  2 ปีที่แล้ว

      Stock up yan boss....

  • @bryansoleta2101
    @bryansoleta2101 4 ปีที่แล้ว +1

    hina ng voice mo tropa.

  • @bryansoleta2101
    @bryansoleta2101 4 ปีที่แล้ว

    maliit lang nmn kc yan eh