  • @hardrockcafe4436
    @hardrockcafe4436 3 ปีที่แล้ว +5

    Buti nlang nandyan c sir lhon, taga ayos ng unit sa mga hindi naayos at cnicira ng ibang technician.Thumps up sau again sir lhon. Another knowledge again ang nlaman q sa video na ito.😀

  • @marvinalba2574
    @marvinalba2574 3 ปีที่แล้ว +4

    Galing talaga ni ka Master..
    Yan ang honest na technician sinasabi talaga Kung ano lang ang totoong sira..
    Pa shout out idol .
    From Cagayan valley

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  3 ปีที่แล้ว

      Yuun nuhhh😇😇
      Sure sir sa susunod na vlog ko asahn mo yan👍👍👍

  • @enricoaviles6397
    @enricoaviles6397 3 ปีที่แล้ว +1

    Saludo ako sa yo Sir, mahusay kang magpaliwanag at magtrouble shooting kaya naiintindihan ng customer kung ano ang rootcause kung bakit nasira o ayaw gumana ng maayos ang kanilang appliances, new subscriber mo ako from Pasig City,

  • @EdNavaleGuevar
    @EdNavaleGuevar 3 หลายเดือนก่อน +1

    Yun pala ang dahilan kung bakit high ampere ang window aircon ko, thank you sa tip.

  • @geraldlirio8054
    @geraldlirio8054 3 ปีที่แล้ว +4

    Watching boss lhon.
    Mahusay + tapat sa costumer + hindi nag mamarunong = malupiton😁
    Salute sayo master lhon😊

  • @jpbmoto1063
    @jpbmoto1063 3 ปีที่แล้ว +1

    Salute sir ang galing nyo po. Proud aircon technician.

  • @dingqueridolam2024
    @dingqueridolam2024 3 ปีที่แล้ว +2

    Ayos idol galing mo tlga walng alam sa electrical Yung technician una nag check nyan s unit kya kung patchamba nlang ang findings

  • @joeypadyak811
    @joeypadyak811 3 ปีที่แล้ว +1

    shout out Master lagi ako nanunuod ng video nyo na maraming napupulot na kaalaman ingat palagi sa pag momotor

  • @larrycasio9120
    @larrycasio9120 3 ปีที่แล้ว +2

    Ka master lhon nag aabang ako palagi nang mga vedio mo from iloilo

  • @rodellubio2062
    @rodellubio2062 3 ปีที่แล้ว +2

    Master talaga👍👍💯
    Tnks s tip bossing

  • @angelabayrante6775
    @angelabayrante6775 3 ปีที่แล้ว

    Good day idol im whatching frm bicol isa po ako taga subay bay ng mga vlog mo isarin po ako tic maraming salamat idol sa mga turo po ninyo lalong lalo na sa isang tulad ko naguumpisa plang

  • @trtr5097
    @trtr5097 3 ปีที่แล้ว +1

    Thank you sir, panibagong kaalaman n nmn sir, godbless.

  • @FbSign4448
    @FbSign4448 3 ปีที่แล้ว +2

    Shout out kamaster always watching new idea galing

  • @eddelromero5692
    @eddelromero5692 3 ปีที่แล้ว +2

    Yun oh malinaw na malinaw ka master

  • @chrislacquin581
    @chrislacquin581 3 ปีที่แล้ว +1

    Good day ka master TV Lhon Santelices thank you po uli for your great work, salamat po sa Dios

  • @kkhentech4939
    @kkhentech4939 2 ปีที่แล้ว +1

    Tama ka DYAN master .. kc base sa electrical theory . Pag baba ng voltage , pagtaas ng Amper .. pagtaas ng voltage pagbaba ng Amper .. po

  • @clodimirsantos2279
    @clodimirsantos2279 3 ปีที่แล้ว +2

    Ka master PWEDE po mag request SA meralco na pataasin Ang supply NILANG BOLTAHE, KAHIT line to ground Ang linya po ninyo, Ang ISANG option na solusyon po DYAN magpadagdag po Ang area ninyo NG a/c capacitor SA transformer NG meralco para tumaas Ang voltage o kung AYAW NG meralco mapipilitang bumili ng avr Ang mga consumer, at kung avr NAMAN Ang kukunin PILIIN po ninyo yung 1% Ang regulation ito' po yung ferro resonant type, MEDYO may kamahalan lang, MERON pang IBANG KLASE yung 3% or yung 5% Ang regulation (switching type tulad NG GAMIT ay contactor., SALAMAT ka master SA sharing NG video po ninyo. Always watching, GOD BLESS PO KA MASTER.

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  3 ปีที่แล้ว +1

      Yoowwwwnnn.😇😇
      Tama po naisip nio sir....
      Tanging avr na nga lng talaga ang takbuhan natin..dahil di natin alam kong kelan nga ba bibigyan ng aksyon itong problema natin sa supply ng kuryente

  • @ramilobernardo8203
    @ramilobernardo8203 3 ปีที่แล้ว +1

    yes aircon naman master the superstar technician.

  • @joebertcerenio429
    @joebertcerenio429 ปีที่แล้ว +1

    Galing master lhon.. Ingat palagi.. Salamat..

  • @junedhaleebrado8273
    @junedhaleebrado8273 3 ปีที่แล้ว +2

    Nice video and good content master...shout out next video master...salamat n advance...
    More power sa channel and GOD BLESS master....🙏👌

  • @rosaurocruz1990
    @rosaurocruz1990 ปีที่แล้ว

    Ayos ka master pati supply ng koryente nakuha mo thanks po

  • @celmarcabagay3508
    @celmarcabagay3508 2 ปีที่แล้ว +1

    Thank you ka master ganun din po dto prob dto Oriental mindoro kya lage ko din payu sa mga customer gamamit ng avr with time delay lalo patay sindi😃

  • @aristonedep3873
    @aristonedep3873 3 ปีที่แล้ว +3

    Watching ka master.. mabuhay ka

  • @sharessmile3384
    @sharessmile3384 2 ปีที่แล้ว

    Nice sir, thanks SA pag share ng video

  • @edmonroyol6570
    @edmonroyol6570 3 ปีที่แล้ว +1

    Tnx for sharing ka master Lhon
    God bless always

  • @vincentramas8134
    @vincentramas8134 2 ปีที่แล้ว +1

    Galing talaga master........na motivate lalo ako sa pag study ng airconditioning. Thru po sa mga videos nyo na informative talaga d best......master sana matulongan mo po ako. D ko pa kc masyado alam but i did already ng minor reprocess sa sira na water dispenser pero maganda nman ang init ng condensing but prob ko lang but d masyado malamig ung evaporator tube niya. Sana po makahingi ng advice tnx again n more power po....god bless

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  2 ปีที่แล้ว +1

      Nakapag flushing at vaccum po ba kau sir

    • @vincentramas8134
      @vincentramas8134 2 ปีที่แล้ว +1

      Wala pa po kc akong pang vaccum master start up ko lang kc mag study n application sa water dispenser. Kaunti plang gamit ko sana magkaroon ako ng vaccum machine but try ko lang po mag lagay ng flo baka gumanda ung gawa ko. Gayahin ko lang sa video nyo po paano mag apply ng flo. Anywayz tnx a lot sa reply nyo po. God bless always.

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  2 ปีที่แล้ว +1

      Napakahalaga po kc ng vacuum para sa mga moisture na nasa loob mg system

    • @vincentramas8134
      @vincentramas8134 2 ปีที่แล้ว +1

      Opo master sa palagi nyo po sinasabi sa mga video nyo po na kailangan talaga. Naghahanap pa po ako na ma salvage na unit para gumawa ako ng vacum. But really happy po here master kc nagawa ko po at humigop po ang capillary tube ng flo....napaka satisfying po sundan ginagawa nyo. Lalo na po nung humigop at least po na check ko na dumaan na po ang flo. Testing ako ulit. Tnx a lot po.

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  2 ปีที่แล้ว +1

      Marami po kau mapupulot na kaalaman jan sir ...keep watching lang po😇😇😇😇

  • @rodelbraceros2335
    @rodelbraceros2335 3 ปีที่แล้ว +1

    Galing master.salamat ulit

  • @sowaiblumamba456
    @sowaiblumamba456 8 หลายเดือนก่อน +1

    Parihong pariho po dito sa amin.. Mindanao... Below 200v ang supply...

  • @angelabayrante6775
    @angelabayrante6775 3 ปีที่แล้ว

    Ako nga po idol aldrin bayrante po dito po ako bicol ingat lagi kau idol lalong lalo napo nagbyabyahi po kau maraming salamat idol ha sana po maging isang magaling na tech at vlogger den po ako tulad nyo

  • @rb1m426
    @rb1m426 หลายเดือนก่อน

    Master dto sa amin good ang winding pero ayaw mag start pero mainit ang compressor. Mag high ampere pero split second 4 ampere. Mag charge sana kami ng refrigerant kaso may leak kaso ang compressor ayaw lang mag start good naman ang capacitor. Watching dto sa riyadh master exit 13 industrial 2.

  • @johnlewis8495
    @johnlewis8495 3 ปีที่แล้ว +1

    ibang klase technician dati gumawa bos baka walang tester sinabi nalang sira capacitor di tenesting . Salamat bos additional kaalaman godbless

  • @jurenjosealcolea1647
    @jurenjosealcolea1647 3 ปีที่แล้ว +2

    Astig ka Master

  • @emmanuelvillanueva4515
    @emmanuelvillanueva4515 3 ปีที่แล้ว +1

    Yoon.....oh........low voltage pala ang problema.keep safe sir khon.

  • @inthislife4350
    @inthislife4350 2 ปีที่แล้ว

    Dapat master nag follow up ka ng video dto na ginamitan mo xa ng avr.. para maipakita mo din na tuloy tuloy na ang takbo ng compressor nyan ac na yan pag tama na ang voltage

  • @mathiaspiano6297
    @mathiaspiano6297 3 ปีที่แล้ว +2

    👏👏👏👏👏👍

  • @efrensagrado6658
    @efrensagrado6658 3 ปีที่แล้ว +1

    Shout mo namAn ako kamaster efren sagrado dati pong ofw electrical technician Ng mga Siemens sub station switch gear. Salamat kamaster.!!!

  • @mercydiaz1500
    @mercydiaz1500 3 ปีที่แล้ว +1

    salamat lagi aq n nood syo utube

  • @dollyvitorpinon5211
    @dollyvitorpinon5211 3 ปีที่แล้ว +1

    Hello ka master galing mo tlaga..

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  3 ปีที่แล้ว +1

      Yuun nuhhh😁😁😁
      Salamat po nag marami mam🤗🤗🙏🙏🙏🙏🙏

  • @rofecarsalvador1000
    @rofecarsalvador1000 ปีที่แล้ว +1

    Watching po

  • @jesustobola9156
    @jesustobola9156 3 ปีที่แล้ว +1

    Galingmo master mg explain mg trouble shoot

  • @kadomeng3975
    @kadomeng3975 3 ปีที่แล้ว +1

    👍👍👍

  • @georgegillbarrientos8288
    @georgegillbarrientos8288 2 ปีที่แล้ว +1

    Thanks master

  • @johncanete789
    @johncanete789 10 หลายเดือนก่อน +1

    Magandang gabi po Ka Master Lhon..may check po ako compressor 410a nmn po Carreir yung standard po ampers ac is 6.2 ang maximum is 8.0..pag check ko po is 39ampers..Sira po ba Compressor?? Ka Masrer Lhon..Mabuhay kah po at Maraming po..

  • @barceltvofficial6358
    @barceltvofficial6358 3 ปีที่แล้ว +2

    Watching lods

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  3 ปีที่แล้ว +2

      Yoowwwnnnn😇😇😇
      Salamat Sir👍👍👍👍👍👍

    • @rolandogrefiel1204
      @rolandogrefiel1204 3 ปีที่แล้ว +1

      Good pm po Sir lhon, tanong ko po...ano ang horse power ang Samsung na motor compressor na K182B. Salamat sir.

  • @josephrato9451
    @josephrato9451 9 หลายเดือนก่อน

    Ka master tanong ko lang... Nung nilagyan ko ng refrigerant yung aircon window type na r22.. Rated ng aircon is 5.5 amphere tapos habang kinargahan ko ng refrigerant ang system ang kanyang amphere ay nasa 3.5amp pero ang compressor poh ay sobrang mainit halos nasa 93 degree celcius... Di ko nalang tinuloy parkarga kasi sobrang init ng compressor... So ano poh ang dahilan na sobrang initn ng compressor? Maraming salamat poh sa sagot... Good bless

  • @batman-xv6zn
    @batman-xv6zn 3 ปีที่แล้ว +2

    ka master bagito po ako... avr lng pla katapat nyan master pra maibigay ang saktong kuryente pra sa a/c o ref.? tnx po sa info kamaster...

  • @bennybuguina4402
    @bennybuguina4402 3 ปีที่แล้ว +2

    master galing mo na ibalik mo dati conection boxtype 🙏🙏🙏

  • @bongelectronics7773
    @bongelectronics7773 3 ปีที่แล้ว +1

    Bong electronic is watching

  • @arrelignacio8460
    @arrelignacio8460 2 หลายเดือนก่อน

    Salamat boss kaya pala tuwing tanghali nag loloko ang ac saglit palang andar compresor na mamatay agad tas ang tagal sumindi ulet pero sa gabi ndi nman nag loloko mababa pala ang voltahe ano kaya pwede solusyon or gamitin para maging sakto amg voltahe boss dami na napalitan voltahe lang pala problema
    Kaya pala Nag palit n ng thermostat nag dagdag bawas sa freon ganon pden sa voltahe lang pala n supply

  • @jasonraydearo7806
    @jasonraydearo7806 3 หลายเดือนก่อน

    ganun din po ba sa split type kasi. kasi nung tinest ko yung sa amin. 4 amps din lang dapat pero pumapalo siya ng 5 amps..
    problema ko rin kasi mag oon siya ng 1 minute then patay agad. after 3 minutes on ulit. salamat po.

  • @ahlsoriano5555
    @ahlsoriano5555 5 หลายเดือนก่อน

    Sir..natural lng ba na Sobrang init ng Compressor kahit na ilangba na Sobrang init ng Compressor kahit na ilangWELCOME Segundo lng namamatay na?
    Pinalitan ko na Capacitor ganon pa rin On / Off pa rin at Sobrang init ng Compresor Segundo lng namamatay na?
    Pinalitan ko na Capacitor ganon pa rin On / Off pa rin at Sobrang init ng Compresor.
    D kaya Sira ang OLP?

  • @hvacae6904
    @hvacae6904 3 ปีที่แล้ว +1

    Mahirap pag yung nag aayos ang me diprensya...kaya mas mabuti kung talagang sa totoong technician madala ng customer. Kawawa customer kung pag aaralan lang nila yung unit. Mabuti e nandyan si master tagasalo

  • @leam7470
    @leam7470 3 หลายเดือนก่อน

    Ilang voltage need boss? Para mag run ung 1hp na Aircon? Ganyan n ganyan po ung akin issue ko sa aircon ko ngaun ilang minutes namamatay sya ..na check ko ung voltage dito sa amin nasa 194.9 voltage po ..

  • @hannahjanebarlongay45
    @hannahjanebarlongay45 3 ปีที่แล้ว +1

    Galing mu master

  • @ethanthegreat1856
    @ethanthegreat1856 ปีที่แล้ว

    ilang voltage po ang minimum para sa katulad ng aircon sa video idol, salamat po sa video na to God bless po sa inyo

  • @oscarpanelo3636
    @oscarpanelo3636 3 ปีที่แล้ว +1

    thanks for your very informative and inspiring tutorial videos sir, aside from low voltage, capacitor fault, defective olp and thermostat pero good nman ang compressor windings ano pa kaya yung ibang possible reason but naghahigh ampere ang compressor?

  • @ahlsoriano5555
    @ahlsoriano5555 5 หลายเดือนก่อน

    ba na Sobrang init ng Compressor kahit na ilangWELCOME Segundo lng namamatay na?
    Pinalitan ko na Capacitor ganon pa rin On / Off pa rin at Sobrang init ng Compresor

  • @magdasanantonio196
    @magdasanantonio196 2 ปีที่แล้ว +1

    Ka master ano po ang require na vboltahe o minimum na boltahe para tumino. At ano remedyo jansa mahinang koryente
    At kung ok na ang koryente
    Aandar po ba ng matino ang unit na yan???

  • @hardrockcafe4436
    @hardrockcafe4436 3 ปีที่แล้ว +2

    Nice video sir lhon, tanong lng po sau, kapag ganyang situation ok lng ba lagyan ng AVR kung mahina ang supply ng kurente sa compressor?

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  3 ปีที่แล้ว

      Avr po talaga ang solusyon sir...gaya ng ginawa ko napabili ako bigla dahil sa lagay ng kuryente nmin dto.masisira unti unti mga pinundar na gmit

  • @JoseSanchez-to2ou
    @JoseSanchez-to2ou 3 ปีที่แล้ว +2

    Lhon,may epecto ba sa ref kung hinde mo ginamit ng matagal?

  • @sonnypasion5327
    @sonnypasion5327 3 ปีที่แล้ว +1

    Anong magandang Sulusion, ka master para magamit ang air-con o refrigerator,kung mababa ang kuyerte. Supply??

  • @ninodantis7683
    @ninodantis7683 3 ปีที่แล้ว

    Hello po sir ric sana po manoticed may tanong po sana ako kasi hindi po malaman ng pinagpagawaan namin ng aircon kung ano po tlga ang sira una po namamatay ang compressor pati ang fan pinagawa po namin sabi freon nagbayad po kmi ng 2k after edi nag ok po sya after 3days po mas lumala lagi na namamatay kung before namin ipagawa 1to2times aday namamatay ngaun minutes lang po namamatay na and ibinalik po namin sabi bearing sa fan ganun padin po ang dami napo namin nagastos sana po manotice nyo po sir

  • @francisgayonganon1895
    @francisgayonganon1895 2 ปีที่แล้ว

    Sir good day from bacolod negros occidental. Ask po ako sana about sa TECUMSEH compressor ko sa ice cream machine. Bakit po laging nag jammed yng rotot shaft. Wala naman play yng rotor bearing. Salamat.

  • @kharlivanbalat1896
    @kharlivanbalat1896 ปีที่แล้ว +1

    ano baga iyan ka master haha idol

  • @ceferinodumadag1765
    @ceferinodumadag1765 ปีที่แล้ว

    Gud am ka mastre...may e tanong ako sa iyu..paano malamam kung cra na ang aircon compressor...kung difecteb na ano ang reading sa ohms..salamat

  • @henzkasan8277
    @henzkasan8277 3 ปีที่แล้ว +1

    Dbest ka tlga idol, ,

  • @elmerromero7556
    @elmerromero7556 3 ปีที่แล้ว +3

    Master,ano po ba pinag kaiba ng thermostat na pang ref sa pang aircon ?

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  3 ปีที่แล้ว

      Nagkakaiba sila sa design kong anong temperature magka cut off..meron yan nakalagay sa thermostat..pero ung trabaho nila ay iisa lng.to control the temperature.

    • @elmerromero7556
      @elmerromero7556 3 ปีที่แล้ว +1

      @@kamastertvlhonsantelices sa appearance nila master ano po pinagkaiba nila ?

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  3 ปีที่แล้ว +1

      Halos iisa lng ang itsura ng pang windown type at pang ref.pero magkaiba na lng yan sa haba at iksi ng pin.at ung mounting

    • @elmerromero7556
      @elmerromero7556 3 ปีที่แล้ว +1

      Pwede po bang magamit yung thermostat na pang ref at sa window type po ikakabit na aircon po ?

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  3 ปีที่แล้ว +1

      Dipo pwede magkaiba po sila ng setpoint

  • @robertwadeii7175
    @robertwadeii7175 2 ปีที่แล้ว +1

    Master ambait mo naman walang bayad check up mo. Samin may bayad Yan 500 pesos.

  • @johnmaxveljrmarquinez3807
    @johnmaxveljrmarquinez3807 3 ปีที่แล้ว +1

    shout out boss

  • @antoniocorpuz1466
    @antoniocorpuz1466 ปีที่แล้ว

    Ka master lhon pwede rin bang pang plushing tetra chloride sa evaporator at sa condenser ng ref.

  • @domingopepito4545
    @domingopepito4545 3 ปีที่แล้ว +1

    pa shout out naman ka master.. from dammam ksa..... seiko.. inta malum sadik☺️☺️

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  3 ปีที่แล้ว

      Aiwahhhhh😁😁😁
      Mafi mosquil muder...shout out kita sa susunod na vlog👍👍👍👍

  • @winstontaganna318
    @winstontaganna318 3 ปีที่แล้ว +1

    Ka master saan ka bomabasi ng resistance ng compressor windings kng bad or good?

  • @jeperparde3375
    @jeperparde3375 3 ปีที่แล้ว +1

    Master Lhon paano ba irepair GALINI ice maker andar cya tapos di pa buo ice namamatay ang comp.

  • @monaytvrcp9250
    @monaytvrcp9250 3 ปีที่แล้ว +1

    Low voltage, over charging, capacitor fault, compressor Winding and bearing goodbye
    Yan ba mga posible pag high Ampere master?

  • @acelgarcia1428
    @acelgarcia1428 3 ปีที่แล้ว +2

    Ka master tanong lang po ano maganda avr gamit para sa ref.bka pwede mgbigay ka ng link.kng saan makabili salamat ka master

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  3 ปีที่แล้ว +1

      Maganda po ung Panther na brand..sa lazada po meron.oh di naman kaya sa quiapo marami pamimilian

  • @ricklindamasco2071
    @ricklindamasco2071 2 ปีที่แล้ว

    Master lhon.yung compresor po ba ng ref pwd rin po gawing pang flushing

  • @jozuarato1756
    @jozuarato1756 2 ปีที่แล้ว +1

    ka master gud am poh...ano po niligay jan sa kuryente ninyo para maging 220 volts na output ninyo..kasi same rin dito sa amin mababa lang poh kuryente..laging nasisira unit namin dito...

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  2 ปีที่แล้ว

      AVR po na 2500 watts

    • @jozuarato1756
      @jozuarato1756 2 ปีที่แล้ว

      @@kamastertvlhonsantelices ah ok boss salamat... ask ako ulit boss kung anong good range (ohms) ng overload protector at relay...para malaman kung good and bad..salamat boss sa sagot

  • @albertonedera6745
    @albertonedera6745 3 ปีที่แล้ว +2

    Kamaster Boss Sir lhon anong applicable na avr para dyan saka pwedi ups dyan

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  3 ปีที่แล้ว

      Dipende po sa wattage ng compressor sir.pwede naman 500w at 1k watts

    • @albertonedera6745
      @albertonedera6745 3 ปีที่แล้ว +1

      Thanks poh sa pagsagot kamaster Boss Sir lhon naway pagpatuloy mo pa ang maraming video para makasabay tayo sa ibang lahi

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  3 ปีที่แล้ว

      Welcome po sir...ang totoo niyan ginagaya po ang channel ntin ng isang ibang lahi...430 pa lng ang kanyang subscriber pero ung content nia mukhang sakin kinakopya😭😭😭😭

    • @albertonedera6745
      @albertonedera6745 3 ปีที่แล้ว +1

      Kamaster Boss Sir lhon copy wright un ha hehehe

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  3 ปีที่แล้ว

      😁😁😁

  • @iniopaa8956
    @iniopaa8956 3 ปีที่แล้ว +2

    Kamaster ngaun lng nakanood. Ngaun lng nagkaload nahuli n ko

  • @angelabayrante6775
    @angelabayrante6775 3 ปีที่แล้ว

    Dati idol yong tech ko my nagpunta s shop magpachick ng ref pinontahan nya sa house tapos chick nya tapos kinausap nya na wagna ipasok sa shop d nya alam na pinsa ko ang kinausap nya nabuko ko agad idol kaya dko na pinagtagal kc mahirap na my kasam ka sa hanap buhay na mangloloko

  • @alvingamboa5919
    @alvingamboa5919 2 ปีที่แล้ว +1

    ,master lhon tanong ko lng po mag kano po ba singil sa split type pag full down cleaning?slamat po god bless ingat po lge master

  • @jojomantala9067
    @jojomantala9067 3 ปีที่แล้ว +1

    Pati pala dyan sa iyong pwesto ka master low volt

  • @bbbb7949
    @bbbb7949 2 ปีที่แล้ว +1

    Gud am sir magkano po avr kulang din po kc supply ng koryente dto nmmty din aircon nmen tnx po sir..

  • @hannahfuentes8201
    @hannahfuentes8201 3 ปีที่แล้ว +1

    Sir tanong ko lang po...bakit po minsan po ung aircon po namain yung half part po nia d po malamig....kakabili lng po nung feb 2020....1 yir n po xa ngaun...kelangan n po siyna ipalinis...

  • @mariopangan9877
    @mariopangan9877 3 ปีที่แล้ว +1

    Sir. Gud morning po. Ganyan din po problema ng aircon ko na window type.
    Ano pa tamang gawin jan kung sa power source abg problema na mababa ang voltahe?

  • @dolfedjtech5529
    @dolfedjtech5529 3 ปีที่แล้ว +1

    Watching master,,,, pwedi po magtanong master,,,may inaayos ako na refregerator,,,sabi ng costumer ayaw daw uman dar ang motor compressor? Check ko po lahat,,,sira ang thermosta,,pinalitan ko,,,gumagana na xa,,,after mga 10 minutes namamatay xa,,,
    Check ko agad ang relay at overload mainit xa,piro tenester ko,ok naman continuity,,,piro malamig sa taas,parang hilaw ang pagkalamig parang moisture,,,ok din voltage sa saksakan,,, anu paba dapat kylagan gawin or check? Salamat po sa sagot,,, godblessed lagi master Lhon,,

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  3 ปีที่แล้ว

      Check nio po.mna resistance ng compressor baka naman.malayonna ang diferential

    • @dolfedjtech5529
      @dolfedjtech5529 3 ปีที่แล้ว

      cs=18.4 ohms
      cr=17.4 ohms
      sr=35.3 ohms

  • @emmadomingo8377
    @emmadomingo8377 3 ปีที่แล้ว +1

    Tanong lang po kong gumgawa po kayo ng panasonic topload. Tumotulo po sya. At magkano po.

  • @rogeliorota8196
    @rogeliorota8196 2 ปีที่แล้ว

    Mag by pass sa CSR , pwede ba kahit high side at low naka install?

  • @marlonkismot3679
    @marlonkismot3679 ปีที่แล้ว

    Good day Sir, ask ko lng po naghahigh ampere po ang LG 2hp split type aircon ko kakapalit lang po ng capacitor at compressor.. 230volts naman po ang supply. Sana po manotice..

  • @robertcuaderno9021
    @robertcuaderno9021 2 ปีที่แล้ว +1

    Idol Meron Po bang scenario na goods ang reading Ng cap. Pero sera ang capacitor???

  • @alvingamboa5919
    @alvingamboa5919 2 ปีที่แล้ว

    ,master sbi mo nga po pla sa isang video mo my gc ka po baka po pwedi mka sali po pra po dun nlng po ako mag tatanong kung sakali po na my itatanong po ako slamat po

  • @nashydreibuensalida5384
    @nashydreibuensalida5384 2 ปีที่แล้ว

    an0 brand Ng tester mo at mo saan mo nabili ty nonoy Ng laspinas city

  • @ninodantis7683
    @ninodantis7683 3 ปีที่แล้ว +1

    Ganyan ganyan po ang problema namin sa aircon namin Hello po sir ric sana po manoticed may tanong po sana ako kasi hindi po malaman ng pinagpagawaan namin ng aircon kung ano po tlga ang sira una po namamatay ang compressor pati ang fan pinagawa po namin sabi freon nagbayad po kmi ng 2k after edi nag ok po sya after 3days po mas lumala lagi na namamatay kung before namin ipagawa 1to2times aday namamatay ngaun minutes lang po namamatay na and ibinalik po namin sabi bearing sa fan ganun padin po ang dami napo namin nagastos sana po manotice nyo po sir

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  3 ปีที่แล้ว

      Yun lng...di kc dumaan sa maayos na diagnosis kaya lumalabas na ang totoong problema

    • @ninodantis7683
      @ninodantis7683 3 ปีที่แล้ว

      Anu po kaya master and sira di po kasi malaman sana po matulungan nyoko laki na po nagastos mas lalala pa po pla eh isinisingit ko lng ung pinambayad ko pangpa gawa di dun nagawa salamat master sana manoticed

  • @jessmac2379
    @jessmac2379 2 ปีที่แล้ว

    Normal po ba yung puting clay sa taas ng compressor sa bagong aircon ko? O leakage yun?

    • @jalenhipolito4338
      @jalenhipolito4338 2 ปีที่แล้ว

      normal n may clay para di pasukan ng tubig

  • @robertlopez193
    @robertlopez193 3 ปีที่แล้ว +1

    Master lhon saan mo ba nàbili yan torch mo salamat

  • @kasangkaytechnician1985
    @kasangkaytechnician1985 2 ปีที่แล้ว +1

    Boss na salamat sa na share mo maganda may mapupulot na kaalaman. Baka pwede ako boss pa hug salamat

  • @andylopez3612
    @andylopez3612 3 ปีที่แล้ว +1

    Low voltage,high amperes

  • @jerryleevlogs486
    @jerryleevlogs486 3 ปีที่แล้ว +1

    Ka master may tanong po ako sa inyo kasi po may ref po kami dito na ang tatak samsung digital inverter umaandar sya pero mga 5 minutes mamamatay yung compressor ka master..ano po kaya ang problema nun ka master pakisagot naman ka master oh..

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  3 ปีที่แล้ว +1

      Kylangan makita po sa dalawang board ung number of blinks..para malaman natin konh anong problema

    • @jerryleevlogs486
      @jerryleevlogs486 3 ปีที่แล้ว

      @@kamastertvlhonsantelices hindi po nagblink yung main board ka master..yung compressor lng po bakit hindi tuloy2x yung andar nya bakit sya namamatay after 5 minutes ka master

  • @arnelestonilo1157
    @arnelestonilo1157 2 ปีที่แล้ว +1

    Master pahiras ng ac ko mas matagal ung idle 17min to 20min working time 4min to 6min lang pag check ko ng amper mag simula sa 8amps pataas hanggang 14.7 tas mag cut off na. Pero nandito ako sa saudi kaya maganda nmn kuryente dito pero d ko pa na check. Ano pa kaya pwd kong i check master.

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  2 ปีที่แล้ว

      Check mo sadik
      OLP
      Compressor and Fan Capacitor
      Compressor windings

    • @arnelestonilo1157
      @arnelestonilo1157 2 ปีที่แล้ว

      @@kamastertvlhonsantelices sige po bro update kita pag na check ko

    • @arnelestonilo1157
      @arnelestonilo1157 2 ปีที่แล้ว +1

      Ano po ung o l p master?

    • @kamastertvlhonsantelices
      @kamastertvlhonsantelices  2 ปีที่แล้ว

      OLP
      Overload protector

    • @arnelestonilo1157
      @arnelestonilo1157 2 ปีที่แล้ว

      Bro hind ko mababa ung ac ang bigat, kaya d ko pa na check ung olp, ito lang na check ko ung capacitor ng com. 45uf reading 44.87uf ung sa fan capacitor naman 8uf reading 7.95uf
      Ok ung mga capacitor ung winding nmn ng com. C to S 1.7omhs C to R 1.8ohms and R to S 3.4ohms naman,
      Ok nmn ata ung olp kasi nag cut off pag high current na. Ung voltage naman 227volts
      Ano na kaya problema nito bro pag nagana naman malamig.

  • @angelabayrante6775
    @angelabayrante6775 3 ปีที่แล้ว

    Sana idol maging isang tulad den po ako ninyo isang magaling ng tech actually idol dati gsto kulang maging magkaroon ng shop ng ref at aircon nakakoha ako ng mga tao kaso niloloko po nila mga customer madalas po backjob po madalas palpak hindi manlng ako naturoan kc po mangloloko nga ng dahil idol sa mga vlog nyo natuto po ako maraming salamat idol sa mga vlog nyo