  • Ryan Malanoski of Alarm System Store steps you through the basic programming of a DSC Power Series alarm system. Follow him as he guides you in setting zone information, delay times, and many more steps of the basic programming of this alarm panel. He also introduces you to our quick start guide which makes programming very simple compared to the manufacturer's manuals.
    Please comment in the comments section if you have any questions and be sure to slap that like button and subscribe to our channel for all of our how to videos for some of today's most popular DIY security systems.
    You can also visit our website at alarmsystemstor... for all of our great deals on security equipment.
    You can also follow us on the following social sites for information, coupon codes, and much more!
    Facebook - / alarmsystemstore
    Twitter - / alarmstore

ความคิดเห็น • 92

  • @eugenetswong
    @eugenetswong 2 ปีที่แล้ว +6

    NOTES
    03:22 Entering Programming Mode [*6], And Setting Time & Date [[24 hr format] hhmm mmddyy]
    04:36 Entering Installer Mode [default password: 5555]
    04:52 Entering Zone Data [001 & 002]
    05:54 Toggling Zones [202]
    06:21 Entering Partition Data [005]
    07:33 Entering Resistor Data [013]
    08:09 Setting Telephone Reliability [015]
    08:58 Quick Start Guide
    09:20 Setting Master Code [007]
    09:48 Getting Orange Triangle Data [*2]
    10:12 Conclusion

  • @PCman50
    @PCman50 3 ปีที่แล้ว +3

    This is so very helpful. Thank you for this excellent tutorial.

    • @andybowman9697
      @andybowman9697 3 ปีที่แล้ว

      You are most welcome. Glad you found it useful!

  • @daphnacaplan53
    @daphnacaplan53 ปีที่แล้ว

    Thanks for the info. I bought a new remote (same as I currently have) and need to code it to the alarm system which has already been programmed. Can't find instructions on how to do this.

  • @sarytan1491
    @sarytan1491 2 ปีที่แล้ว +1

    How to programing 2 keypad difference funtions ??

  • @tonyjones7089
    @tonyjones7089 3 ปีที่แล้ว +2

    Adding a wireless contact, I inadvertently made my front door (Zone 1) to show it being open, when in fact the door is closed. How do I go back and correct this to show that the door is closed or open correctly? Thank you!

  • @alexanderippolito5408
    @alexanderippolito5408 2 ปีที่แล้ว

    Hello
    How do you adjust the brightness on the pk5501? It seems to not save my brightness level. Keypad is dark.

  • @tupelowoodcarver1785
    @tupelowoodcarver1785 11 หลายเดือนก่อน

    My 5500 keypad displays low battery key 2. Cannot find key 1 in 804 any help finding key 1 and key 2 locations.
    Also moved this keypad from my old house to my new one. Used to display open zones but doesn’t now?

  • @tupelowoodcarver1785
    @tupelowoodcarver1785 ปีที่แล้ว

    Using pk5501 followed the quick start and video. Have 4 zones. 1 being front door (delay), 2 interior door (instant), 3 motion (set to 5), 4 interior (instant).
    My motion does not work. Thought it was a bad sensor and changed. Same result. Is there something I’m missing? What should the attributes on this be?

    • @AlarmSystemStore
      @AlarmSystemStore  ปีที่แล้ว

      Generally you don't mess with attributes for a hardwired zone.

    • @tupelowoodcarver1785
      @tupelowoodcarver1785 ปีที่แล้ว

      @@AlarmSystemStore any ideas why it does not operate? I checked, and I have 12v at the board, and terminals are nc/c
      How would I program/re program just the motion w/o erasing the system. Thanks btw

  • @robertrutenberg3919
    @robertrutenberg3919 3 ปีที่แล้ว +1

    How do you program the keypad on a dsc so it doesn't beep when the ac power goes out?

  • @roystervi
    @roystervi 4 ปีที่แล้ว +1

    any video on how to add zones to partitions?

  • @Yeahitsmeagain92
    @Yeahitsmeagain92 2 ปีที่แล้ว

    My zone with the magnetic contact has the green check mark but doesn’t turn off when the contact is disconnected. Its not sending a signal when open. Any ideas?

  • @jean-marckanzki3051
    @jean-marckanzki3051 11 หลายเดือนก่อน

    Good evening anyway i could contact you directly, to help me with a my homes systems?

  • @tyhillinc
    @tyhillinc ปีที่แล้ว

    Question my dsc go off even night at 12:41 am with me sitting it someone told me it may be scheduled please help

  • @youngfox12
    @youngfox12 3 ปีที่แล้ว +1

    I need to know what your profession is. I don't know how it is called in English. Thank you

  • @omotayosamuel49
    @omotayosamuel49 2 ปีที่แล้ว

    my dsc is showing gen system temp, what does this mean?

  • @shelliecoats1979
    @shelliecoats1979 4 ปีที่แล้ว

    We purchased a home with a media panel and this alarm system with motion detectors. I unplugged it because we had no information on how to set it up. It has been 9 months since we moved in and now I am ready to tackle this installation. HELP!!! I have no codes from the previous owner and I really am not sure where to begin, other than plug it back into the media outlet and I have the alarm box as shown above. I don't really even know what else to do. I would really appreciate any help. Thank you.

  • @shafirsf
    @shafirsf 4 ปีที่แล้ว

    Pls tell how to connect bentel bgsm 120B gsm module to DSC 1832

  • @pablowang2193
    @pablowang2193 ปีที่แล้ว +2

    Thank you so much

  • @jj-iv8ql
    @jj-iv8ql 3 ปีที่แล้ว

    Hi - can anyone advise how to set a DSC LCD 5511 stay mode to have a delay of 20 sec if activated - my alarm has been set to activate with no warning - people keep opening windows - and alarm activates straight away thanks

  • @thekliable
    @thekliable 2 ปีที่แล้ว

    Hi! I changed my SIM Provider, removed the SIM PIN, yet I get the following troubleshoot message: Cellular Trbl, Alternate Communication. I have contacted the Phone Provider, and there is active signal on the SIM. Could anyone please help? thanks!

  • @gidbosson-route786
    @gidbosson-route786 5 หลายเดือนก่อน +1

    i cant find the quick start guide 😔😔

    • @AlarmSystemStore
      @AlarmSystemStore  5 หลายเดือนก่อน

      www.alarmsystemstore.com/pages/programming-quickstart-guides

  • @Yeahitsmeagain92
    @Yeahitsmeagain92 2 ปีที่แล้ว

    My magnetic contact has the green check mark but doesn’t turn off when the contact is disconnected. Any ideas?

    • @AlarmSystemStore
      @AlarmSystemStore  2 ปีที่แล้ว

      Too many possibilities to really explain each here but.. programming, wiring, contact itself, zone def used. You really just need to explore each. If you have multiple contacts on one zone, perhaps you've wired them in parallel rather than series.

    • @Yeahitsmeagain92
      @Yeahitsmeagain92 2 ปีที่แล้ว

      @@AlarmSystemStore ive checked the wiring and the contact itself. Any ideas on zone definitions? What zone definition is for a magnetic contact that stays on?

    • @AlarmSystemStore
      @AlarmSystemStore  2 ปีที่แล้ว

      @@Yeahitsmeagain92 Any zone def that has force arm on such as the stay / away types will always show green like that.

  • @MaggioRacinginc
    @MaggioRacinginc 3 ปีที่แล้ว

    I have a dsc wired motion sensor that I want to remove. Can I just jump zone 1 to com and remove the wires. I do not have the installer code.

    • @AlarmSystemStore
      @AlarmSystemStore  3 ปีที่แล้ว

      Yes that would work assuming your panel isn't using resistors. If it is however, you would need to use a 5.6k resistor to jumper it there.

  • @straighttothepoint364
    @straighttothepoint364 3 ปีที่แล้ว

    How do I reprogram after canceling our monitor service to stop sending signals to avoide the error code 4 ? The person keeps saying we need a service call or get monitoring again. Can I just disconnect the communication wire?

    • @AlarmSystemStore
      @AlarmSystemStore  3 ปีที่แล้ว

      Unplugging the phone cable will still generate the FTC / Comm error. Only way to resolve it will be to deprogram comms in the system. If you don't have the installer code though you will be unable to do so.

    • @straighttothepoint364
      @straighttothepoint364 3 ปีที่แล้ว

      @@AlarmSystemStore is there a way to find the installers code? The installer will not provide me with the number can I factory reset?

    • @AlarmSystemStore
      @AlarmSystemStore  3 ปีที่แล้ว

      @@straighttothepoint364 TH-cam "DSC factory reset". If it's had installer lock enabled though it will not reset the code and there is no way around it.

    • @straighttothepoint364
      @straighttothepoint364 3 ปีที่แล้ว

      @@AlarmSystemStore so that's how this guy scams another service call...ill leave it unpluged

  • @alanhill3968
    @alanhill3968 4 ปีที่แล้ว

    Help needed please. I cannot set my DSC alarm in stay mode, what setting do I need to look at TIA

    • @tr4ptamine
      @tr4ptamine 4 ปีที่แล้ว +2

      Press and hold the stay key (or the house with a person in it,for international keypads) and it should arm to stay

  • @aaronrynehart468
    @aaronrynehart468 3 ปีที่แล้ว

    Is there a way to stop the external strobe beeping when you turn the alarm on and off?

    • @andybowman9697
      @andybowman9697 3 ปีที่แล้ว

      Strobes dont normally beep so I assuem you are talking about a siren doing this. Yes, the option is called "bell squawk on arm / disarm" It is off by default though. This is in program section 014, opt 1.

  • @abureehan486
    @abureehan486 4 ปีที่แล้ว +2

    Very very nice. THANKS

  • @johnhewetson4406
    @johnhewetson4406 4 ปีที่แล้ว

    Can anyone explain to me what (071) First User Display Mask and (072) Second User Display Mask do?

  • @ajithk.a5556
    @ajithk.a5556 3 ปีที่แล้ว

    sir , what is the code for PIR sensor with exit delay?

    • @AlarmSystemStore
      @AlarmSystemStore  3 ปีที่แล้ว

      All zone types will provide an exit delay, but if you want a motion to be stay and away capable as well as have an entry delay you would use an 06 type.

    • @ajithk.a5556
      @ajithk.a5556 3 ปีที่แล้ว

      @@AlarmSystemStore Thank You sir, and one more , How to label each zone to identify?

    • @AlarmSystemStore
      @AlarmSystemStore  3 ปีที่แล้ว +1

      @@ajithk.a5556 This is done in keypad programming, assuming that you have a full alpha model keypad. I don't believe we have a vid on it but I will add it to our list.

    • @ajithk.a5556
      @ajithk.a5556 3 ปีที่แล้ว

      @@AlarmSystemStore I don't have full alpha keyboard. I watched your neo keypad video, Is that zone labeling settings same as above green light keyboard?

    • @AlarmSystemStore
      @AlarmSystemStore  3 ปีที่แล้ว

      @@ajithk.a5556 If you don't have a full alpha pad you can't program zone labels.

  • @rogehrify
    @rogehrify 4 ปีที่แล้ว

    When I power up the system and connects the bell I get a low yelp alarm from it. When I measure the bell output I constantly have about 12 V from the output. If I trigger an alarm the siren works att full volume so the system seems to work, but I cant get rid of the low volume alert sound! Any ideas what to do?

    • @AlarmSystemStore
      @AlarmSystemStore  4 ปีที่แล้ว +1

      There is always supervisory voltage on the bell output. Generally the siren is not sensitive enough to sound from this. If it does though, you will need to add a resistor. I don't recall the value off hand but I'm thinking it's a 1k.

    • @rogehrify
      @rogehrify 4 ปีที่แล้ว

      @@AlarmSystemStore I used a resistor and now it is quiet :) Thank you for your videos, I would have been lost without them 👍👍

    • @rogehrify
      @rogehrify 4 ปีที่แล้ว +1

      @@AlarmSystemStore , I´m almost done installing my home security system :) The only thing that´s not working is the telephone dialler. I haven´t got any landline, only an old GSM dialler (Ericsson TS90) but I can´t get it to dial my phone when I trigger the alert. The display shows communication error and there are two cables on the gsm-dialler that´s not attached to the board... I havent got a clue where to attach them. Any ideas what to do? If I call the dialler from my cellphone I can see that the small light on the gsm-dialler changes, so it´s indicating that the sim-card connection works anyway..

  • @pjsjourneys4968
    @pjsjourneys4968 3 ปีที่แล้ว

    I inadvertently made several Zones to show them being open, when in fact the doors/windows are closed. How do I go back and correct this to show that the doors/windows are closed or open correctly? Thank you!

  • @bobwalton4630
    @bobwalton4630 3 ปีที่แล้ว

    I have a DSC system with three keypads, three partitions and a RF repeater. All I have to do is delete a zone in trouble and learn a new one in. I tried all three keypads and my programmer and could not get into programming. I press *8 and it says, "INVLID ENTRY" before I even enter the installer code. I am going back tomorrow and I do not want to have to swap it out

    • @AlarmSystemStore
      @AlarmSystemStore  3 ปีที่แล้ว +1

      I could see getting that after your code is entered, but I've never seen it display that from simply hitting *8.

    • @bobwalton4630
      @bobwalton4630 3 ปีที่แล้ว +1

      I think it was because one of the partitions was armed

    • @AlarmSystemStore
      @AlarmSystemStore  3 ปีที่แล้ว

      @@bobwalton4630 Ahh yes that will do it too.

  • @umarb4523
    @umarb4523 4 ปีที่แล้ว

    When i try to go in enrollment mode 898 or 804 it just backs out and says enter section again... please help??

  • @marie22blue68
    @marie22blue68 4 หลายเดือนก่อน

    please help . the house alarm is not working its only ac

    • @marie22blue68
      @marie22blue68 4 หลายเดือนก่อน

      The system is not ready

    • @AlarmSystemStore
      @AlarmSystemStore  3 หลายเดือนก่อน

      If you have an order number from Alarm System Store, you may reach out to us via our tech form on our website: www.alarmsystemstore.com/pages/technical-support
      Otherwise, I would recommend reaching out to a local provider for assistance.

  • @moviesword8801
    @moviesword8801 3 ปีที่แล้ว

    How to remove partitions selection? Even I did hardware reset and system reset it always appear, it's hassle you need to choose from partitions 1 to 4

    • @AlarmSystemStore
      @AlarmSystemStore  3 ปีที่แล้ว

      There are several steps to partitioning a system, most of the programming step in the panel. There is one however in the keypad programming and that is why resetting the system didn't resolve it. From this particular keypad you need to go into keypad programming 000. Going off memory but I believe you hit 0 again to get to partition and slot which is where you change the partition that this pad is assigned to.

  • @davidfrankos5561
    @davidfrankos5561 2 ปีที่แล้ว +1

    Would have been nice if he would have showed the whole keyboard so you could see what he was doing.

  • @mukeshkumarsingh3265
    @mukeshkumarsingh3265 5 ปีที่แล้ว +2

    Dear sir can you provide PDF file for programing

    • @mukeshkumarsingh3265
      @mukeshkumarsingh3265 5 ปีที่แล้ว +1

      keypaid error showing 1 2 3 4 5 6 7 8 and please suggest how to resolve it

    • @mukeshkumarsingh3265
      @mukeshkumarsingh3265 4 ปีที่แล้ว

      Please reply

    • @AlarmSystemStore
      @AlarmSystemStore  4 ปีที่แล้ว

      @@mukeshkumarsingh3265 Programming guides www.alarmsystemstore.com/pages/dsc-power-series-pc1616-pc1832-pc1864-quickstart

  • @djrobinsa
    @djrobinsa 3 ปีที่แล้ว

    You missed the easy way .... FLOW Chart programming of the panel ... no manual required ..... it flows to each section like the manual reads but o the LCD keypad .... POWER series PK5500 lcd brought it out first but never advertised the feature ...

  • @anthonyhinskon2835
    @anthonyhinskon2835 4 ปีที่แล้ว

    How to program dress code

    • @andybowman9697
      @andybowman9697 4 ปีที่แล้ว

      There is no dress code for programming. Wear whatever you wish when programming, LOL.
      The duress code is programmed in *5 menu just like a user code. Just make it a duress by enabling attribute 2 in the user code section. We have a video about user codes in our play list BTW. Not sure it specifically addresses duress codes but like I said a duress is a user code with option 2 enabled so it's pretty much done the same.

  • @yungkalimusic
    @yungkalimusic 3 ปีที่แล้ว

    Skip to 4:50

  • @guesswhomartin9249
    @guesswhomartin9249 4 ปีที่แล้ว +2

    You video is great. Only you did a lot of unnecessary talking for the first 3:30 of this video. Once you started teaching it was great.

  • @alaaalabdali7133
    @alaaalabdali7133 3 ปีที่แล้ว

    Tack

  • @koulisnoulis
    @koulisnoulis 8 หลายเดือนก่อน

    Καλησπέρα πος μπορο ΝΑΤΟ βαλο να χτυπάει στο κινητο

  • @miguelburke5825
    @miguelburke5825 3 ปีที่แล้ว

    Phone line

  • @equallywrong
    @equallywrong 2 หลายเดือนก่อน

    I'll just pay the service call fee. Thanks anyways.

  • @sum1337
    @sum1337 4 ปีที่แล้ว

    most dsc are ''blind'' where am from what a horrible thing xD

  • @newkeds
    @newkeds 4 ปีที่แล้ว +2

    I'd rather have my home burglarized.

  • @rwnljn
    @rwnljn 3 ปีที่แล้ว

    Horrible place to buy a product. The support folks lie about products being a direct replacement. I bought 4 Smoke Detectors that were not NOT a direct replacement. Lost money and buyer beware!

    • @AlarmSystemStore
      @AlarmSystemStore  3 ปีที่แล้ว

      Rick, the 4WB series is indeed the replacement for the old 2412 series. Call System Sensor yourself and ask, we're not lying. No one here is commissioned or incentivized to do that anyway... check yourself www.systemsensor.com
      Nonetheless, submit an RMA here and we'll refund you. We are an honest company.
      www.alarmsystemstore.com/pages/return-authorization-form-rma

  • @markhughes3383
    @markhughes3383 4 ปีที่แล้ว +1

    What an awkward dated system

    • @andybowman9697
      @andybowman9697 4 ปีที่แล้ว +4

      Not nearly as much as Honeywell. The Vista is technically an antique I believe.

    • @1990notch
      @1990notch 4 ปีที่แล้ว

      @@andybowman9697 the vista is very reliable though.

    • @sum1337
      @sum1337 4 ปีที่แล้ว

      @@1990notch and you plug in your programming keyboard and boom done while most dsc are ''blind'' horrible to program

  • @michaellair6691
    @michaellair6691 ปีที่แล้ว

    What a horrible description on what zone type to use for motions. It should be a zone type 4 Interior follower. If you program as 5 and your walk across your living room to turn off your alarm by the front door the alarm trips because you walked in front of the motion that has been programed as an instant. The interior follower knows you've open an entry exit zone and will give you time to disarm BUT if you come through a living room window and walk in front of the motion it goes of instantly because you did not open an entry exit zone, and yes they will also shut off when armed as stay.

    • @AlarmSystemStore
      @AlarmSystemStore  ปีที่แล้ว +1

      Might wanna brush up on your DSC zone definitions. From the manual:
      [05] Interior Stay/Away: Similar to ‘Interior’ except that panel will auto-bypass the zone if Armed in the Stay mode
      05 is in fact an interior. The only differnce is it allows you to automatically bypass in stay mode in case you want to arm at night and walk around without tripping the motions. 04 is generally only used in commercial where that is not needed.