Biggest Mistakes in Beam on Construction Site - Practical video of Plinth Beam Beam on Site

แชร์
ฝัง
  • เผยแพร่เมื่อ 20 ม.ค. 2025

ความคิดเห็น • 41

  • @sikandarcarpenter2565
    @sikandarcarpenter2565 3 ปีที่แล้ว

    So beautiful 👍

  • @reynaldoguarra5690
    @reynaldoguarra5690 7 หลายเดือนก่อน

    Thank you sir!
    From Philippines

  • @jitubhai18
    @jitubhai18 3 ปีที่แล้ว

    You have good knowledge ,keep posting such vdos

  • @ramkrishnan7347
    @ramkrishnan7347 ปีที่แล้ว

    Sir is it compulsory to provide stone masonry wall as support to plinth beams.

  • @anvarpkhan1939
    @anvarpkhan1939 ปีที่แล้ว

    Things to b noted in construction of plinth beam over column footings?

  • @annaduraikamaraj9732
    @annaduraikamaraj9732 8 หลายเดือนก่อน

    Is the hook bend angle enough ? Is not it supposed to be 135 angle and 3” length ?

  • @untouchable9917
    @untouchable9917 2 ปีที่แล้ว

    Thanks nice video, why is all the rods not going through the centre of the column? one rod is on the outside of the column

  • @shaktisehgal9777
    @shaktisehgal9777 2 ปีที่แล้ว +1

    Sir, isn't it better to put stones or AAC blocks in plinth beam as they are stronger than normal bricks and water proof too ?

  • @preetishidgirimath7707
    @preetishidgirimath7707 3 ปีที่แล้ว

    Which sand is good msand or river sand

  • @maheshthakar
    @maheshthakar 3 ปีที่แล้ว

    Pls show right from foundation, columns with stone walls as shown in this video. If stone foundation is used, is it necessary to provide columns?

    • @A2ZHomeGadgets
      @A2ZHomeGadgets  3 ปีที่แล้ว

      Sure complete foundation video comming soon👍

    • @kabircivilstudy5554
      @kabircivilstudy5554 3 ปีที่แล้ว

      As your wish , Stability increases if you use columns.

  • @TheBujji777
    @TheBujji777 9 หลายเดือนก่อน

    Stirrups must be bent 135 degrees. No support at tension zone.

  • @ShringeshPrasadkmjncv
    @ShringeshPrasadkmjncv 3 ปีที่แล้ว

    For basement below the plinth beam what should be the depth of excavation

    • @A2ZHomeGadgets
      @A2ZHomeGadgets  3 ปีที่แล้ว +1

      It's suggested to go for atleast 5 feet below natural ground level, and it also depends on the type of soil and ground conditions.

  • @sajithamm7521
    @sajithamm7521 2 ปีที่แล้ว

    How to calculate length of plinth beam.. please answer

  • @iqbalqureshi6679
    @iqbalqureshi6679 3 ปีที่แล้ว

    Sar dhiraj wala bed ki making video jarur bnao

  • @sreedharabhi9095
    @sreedharabhi9095 3 ปีที่แล้ว +1

    Sir I need plan Ground parking+ 1bhk
    1st &2nd floor 2bhk+1bhk
    3rd floor 1bhk 3 units
    30*43 size 30 feet road South face
    Pls help me

  • @Vinay-go1rg
    @Vinay-go1rg 2 ปีที่แล้ว

    Sir , I have seen civil engg. with 4-5 yrs of expirence are paid 25 - 30k
    Why civil engg. are paid very less inspite of working hard in harsh conditions ?

  • @jayashreekadampur5427
    @jayashreekadampur5427 2 ปีที่แล้ว

    Sir, where the 4 no of bars in plinth beam was wrong. In the situation beam should be have the bottom of 3 bars atleast, because concrete weak in tension at a dia of 12 mm

  • @ashokkumar7505
    @ashokkumar7505 2 ปีที่แล้ว

    Why two roda in between coloum

  • @venkatvurukuti6124
    @venkatvurukuti6124 2 ปีที่แล้ว

    So many mistakes in this beam...
    1.Use more no of steel rods in bottom than top, atleast 3 rods at bottom and 2 on top
    2.Stirrups should be placed at 6 inches each or 150mm to 200 mm
    3.hooks should be bend at 90 degrees
    4. Provide 1 feet development length at end of beam

    • @BEST_AUTO_SALE
      @BEST_AUTO_SALE ปีที่แล้ว

      Yeah exactly

    • @BEST_AUTO_SALE
      @BEST_AUTO_SALE ปีที่แล้ว

      Please suggest me for g + 1 structure 20 × 40 construction

  • @santurakshit1651
    @santurakshit1651 3 ปีที่แล้ว

    Sir plinth beam k niche kya bichange? Plastic/bricks? Mistri bole rehi hai. Plastic bichaiyenge

  • @mdsuleman2526
    @mdsuleman2526 3 ปีที่แล้ว

    Column rods r bend why?

  • @sumankoley1146
    @sumankoley1146 7 หลายเดือนก่อน

    Sir ji app England pe nahi ho kripya hindi main hi bataye , sabko english acche se nahi ata, hindi main batayiye taki sabko samjh main ayee.

  • @Vicky-yo5kc
    @Vicky-yo5kc ปีที่แล้ว

    beam size for g+1

  • @Blackmamba-007
    @Blackmamba-007 3 ปีที่แล้ว

    Anchorage is not provided properly...

  • @kamrulzoha9223
    @kamrulzoha9223 3 ปีที่แล้ว

    Hamare yaha 4 x 16 and
    4 12 Bar

  • @rajasekarpv8893
    @rajasekarpv8893 10 หลายเดือนก่อน

    The location of your construction site??? One more mistake is also there...

  • @harshastyle3798
    @harshastyle3798 9 หลายเดือนก่อน

    Where is 135 degree
    Reply ok now

  • @prashant3329
    @prashant3329 ปีที่แล้ว

    Brick work below plinth totally wrong.plinth beam should on ground level comparing + PCC + Plinth beam+Brick work ( height as per site conditions)+ DPC

  • @rakeshtegginamani4690
    @rakeshtegginamani4690 3 ปีที่แล้ว

    Sir this totally worng sir

  • @anilkumara380
    @anilkumara380 3 ปีที่แล้ว

    U don wrong

  • @sonukumaryadav7319
    @sonukumaryadav7319 2 ปีที่แล้ว

    Wrong