Interesting experiment as always. Thank for sharing. Whats the maximum watt have you ever got from the 1.3 kw panel? I am curious because I want to know the maximum capacity of the charge controller.
A question for you on over panelling: What will happen to the inverter if we supply more current then the supported current from the PV module? For example, if the inverter support 18A, but we supply 20A or more?
Hello sir. I have a UTL 1KV 24V. I did over paneling 4 * 450, I have connected in parallel am seeing only 10 amp current and charging battery at 4 amp. It doest charge battery and max I see 25.5, but when battery is charged in mains it charges the battery till 27.5 and stops. I have connected 2 battery in series. I am using 6 sqmm polycab solar calv3 and using 20 meter cable. Should the SPV not show 24 amps considering if each panels draws 6 amps.. kindly suggest. Am using 2 Exide 150Ah C10 battery. Each day it generates 2 units.
Actually there are many variables. I suggest you take time to watch these videos- th-cam.com/video/R69XP5_Bvhc/w-d-xo.html th-cam.com/video/C5BKd3GntVc/w-d-xo.html
@@ZenInnovations .. thank you sir. I will check again. Very informative videos and thanks for helping with my queries. I spoke with UTL and have shared the videos of my reading. Thank you.. thank you for replying to my queries.
Sir ...For utl gama plus 24v model i have installed 335 /24v× 3 solar panel for this kind of setup what capacity mcb or spd need to be used ...please help
सर जी इसमें कौनसा सोलर चार्ज कंट्रोलर लगेगा और कौनसे कंपनी का अच्छा रहेगा बताओ 🙏 मेरे पास 👇👇 नीचे वाला सिंगल पैनल है Maximum Power [Pmax] Open circuit Volt [Voc] Short circuit current [sc] 335.0 W 46.80 V 9.30 A Maximum Power Voltage (Vmp) 38.10 V Maximum Power Current
I have 760 watt panel on utl gamma plus want to add more 180 watt 2 panels in series. Answer as per your technical knowledge? Utl company personnel suggest 160 watt 2 panels .
In this video, you are using 2 batteries for UTL gamma plus 12v inverter, that means you are using 2 batteries in parallel right? I already have 335watts poly panel - 2 nos, I'm planning to buy 540watts half cut mono panel,can I use three panels in parallel for obtaining 1210 watts. Can I do that connection?
Sir microtek 3kva me 3kw watt penal lga sakte hai or 5kva me 5kw penal lga sakte hai jo maximum seema hai to kya esme 300 watt ya 400 watt penal over lga sakte hai kya please batao 🙏❤️🌹
225 AH means 22 ya 23A le sakta ha. If one charge controller is 10A, other should be set at 13A More details here- th-cam.com/video/1RMkdRQ1vg4/w-d-xo.html
You'll need an MPPT with good VOC support, Like this one- (12V/24V : 40Amps : Max.Voc - 95V) amzn.to/3J4gC2Y (12/24/36/48V: 80Amp, Voc:210V) amzn.to/374S6BH (12/24/36/48V : 80Amps :Max.Voc - 165V) amzn.to/3K9OQnd
Dear Subscriber, Its nice that you want me to Test & compare various Products. However, I cannot keep buying all the products. Hence what you can do is to tweet these companies to send me a review sample.
Bro, i have a doubt. I have 75w panel while testing in multimeter its shows 20v x 3.4A (short circuit current). But while connected with UTL GAMMA PLUS it's shows 14V x 2.8 Ampere current. Whats actually happening here?
Try again with better sun angles. Some variation between advertised & real values is present as explained in solar QNA ep 18. Its also possible it has a bad diodes.
@@ZenInnovations while checking amp with short circuit it's shows 3.4 amp and while connected my multimeter with series its shows 2.8 amps. I've checked with both pwm controller and utl gamma plus.
Sir mere paas ek Vikram solar ka panel lga h jiska voc 49.4 h electrower ka solar pcu h jab chata hai to uska volt kav 20 25 30 37 btata kya mera panel kharab h please reply me
Aapko steplizer lagne ki jarurat ni hi utl gamma me 290 v se uper jate hi protection mode me aa jata hi or it mode me 260 se uper jate hi protection on ho jata hi , same low voltge me bhi hota hi ,age apke yha grid voltge kam aate hi to stabilizer lagana sahi hi verna koi fayda ni hi
@@ZenInnovations Hello sir, I have seen almost all of your UTL Gamma+ videos and go for the same setup, I have installed three UTL 400W mono panels (total 1200W) and 12V UTL Gamma Plus inverter . My panels are around 33 meters away from inverter and are connected with Polycab 4mm dc cable and tilt at an angle of 30-31 degrees Chandigarh , peak generation till date ( may-June 2022) is 30V X 21A = 610W , but you have mentioned your peak generation is around 900W, So should I upgrade dc wire to get full potential of solar panels or are there some other factors which you would suggest . Also I have one other question , the 12V gamma Plus has 40A charge controller so how does it supports 1000W panels as 40A X 12V = 480W is the maximum solar output which we can get from it.
@@ZenInnovations sir mane morning me app se pusha tha k Kea hum kese vi mara Matlab mppt ja pwm solar inverter pe panal laga kar sath me ambrroot rehub pe vi panel laga sakte h ja ne
bhai tune picha ka back nhi dikhaya ji 12 volt ka hai back penal dikhna tha bakwaas krne se yakin nhi hota dikhna bhi hota hai upar se 2 battery use kra
Nice video
Thanks RP
Interesting experiment as always. Thank for sharing. Whats the maximum watt have you ever got from the 1.3 kw panel? I am curious because I want to know the maximum capacity of the charge controller.
Approx 900w
A question for you on over panelling:
What will happen to the inverter if we supply more current then the supported current from the PV module?
For example, if the inverter support 18A, but we supply 20A or more?
Please Join Telegram group for detailed discussion.
Yes eska wait tha mujhe.... jaldi sir
Tonight at 8.30 aa jao premiere pe.
Sir 1280 watt ka solar panal say din m or night m12 v ke 2 bettery 300 ah say kha kha chaltio ho ta ke supply ke jarorat na pady
Everything except AC.
You have to upgrade the battery bank.
Solar saving testing very good 👍
Ji Sir.
Hello sir. I have a UTL 1KV 24V. I did over paneling 4 * 450, I have connected in parallel am seeing only 10 amp current and charging battery at 4 amp. It doest charge battery and max I see 25.5, but when battery is charged in mains it charges the battery till 27.5 and stops. I have connected 2 battery in series. I am using 6 sqmm polycab solar calv3 and using 20 meter cable. Should the SPV not show 24 amps considering if each panels draws 6 amps.. kindly suggest. Am using 2 Exide 150Ah C10 battery. Each day it generates 2 units.
Actually there are many variables. I suggest you take time to watch these videos-
th-cam.com/video/R69XP5_Bvhc/w-d-xo.html
th-cam.com/video/C5BKd3GntVc/w-d-xo.html
@@ZenInnovations .. thank you sir. I will check again. Very informative videos and thanks for helping with my queries. I spoke with UTL and have shared the videos of my reading. Thank you.. thank you for replying to my queries.
Sir muje j batae k Kea hum pwm solar inverter pe panal laga kar sath me ambrroot rehub pe vi panel laga sakte h ja nahe
Yes. You can use Dual Controller Method discussed here-
th-cam.com/video/fOzkVHWq7nA/w-d-xo.html
180 ltr 4 star normal fridge chala sakte hai kya??
Aur agar chalaye to kya hoga??
Fridge discussion here-
th-cam.com/video/X5-3Xs_eghY/w-d-xo.html
Sir ...For utl gama plus 24v model i have installed 335 /24v× 3 solar panel for this kind of setup what capacity mcb or spd need to be used ...please help
MCB calculation
th-cam.com/video/moUnOA0o7b4/w-d-xo.html
सर जी इसमें कौनसा सोलर चार्ज कंट्रोलर लगेगा और कौनसे कंपनी का अच्छा रहेगा बताओ 🙏 मेरे पास 👇👇 नीचे वाला सिंगल पैनल है
Maximum Power [Pmax] Open circuit Volt [Voc] Short circuit current [sc] 335.0 W 46.80 V 9.30 A Maximum Power Voltage (Vmp) 38.10 V Maximum Power Current
No Repeating Pls.
I have 760 watt panel on utl gamma plus want to add more 180 watt 2 panels in series. Answer as per your technical knowledge? Utl company personnel suggest 160 watt 2 panels .
th-cam.com/video/Prm9R6jUafg/w-d-xo.html
Waiting
Tonight at 8.30
Excellent testing video.
Thank you! Cheers!
In this video, you are using 2 batteries for UTL gamma plus 12v inverter, that means you are using 2 batteries in parallel right?
I already have 335watts poly panel - 2 nos,
I'm planning to buy 540watts half cut mono panel,can I use three panels in parallel for obtaining 1210 watts. Can I do that connection?
Yes at your own risk.
@ZenInnovations utl gama + 12 inverter की guide copy मे VOC 15-45, 30-90 लिखा हुआ है 30_90 क्या अर्थ हुआ
That is for. 24v model.
Sir mere pass 100 watt ke 2 penal.75 watt ke 3 panal h.enko utl gama main install kr sakte h kya.agar ha to kese kru taki out put accha mile
Mix panels parallel me lagaye ja sakte hai. More information here- th-cam.com/video/_i1C4Y6Hi5I/w-d-xo.html
th-cam.com/video/T_s7uQ2JJF4/w-d-xo.html
Sir r u using parallel battary bank till now after 3 years. And adverse effects. I am also planning same. Pls share experiences after 3 years.
About 10 years. Parallel setup is very good. Make sure to watch th-cam.com/video/zVMnJFe0vDs/w-d-xo.html
Mere khyal se saving aur jyada ho sakti thi.Shayed load kam hoga.Thanks.
Yes. Correct Guessing.
Cooler Lagane ke baad saving badh jayega.
Perfect and niece video
Thanks Ganesh ji
मुझे समझ नही आया आपका चैनल या व्यू इतने कम केसे है। ये सब कहीं नहीं मिलेगा। लोगों की नजर में नही। आप इसको प्रमोट करो। चाहे पैड हो
Thanks for the inspiration!
Sir solar panels accurate angel ?
Use solar CT app
My utl gamma plus cooling fan does not move whole charging with panel, may I know what is the reason behind. Adding, tell me how to repair
Query unclear.
Sir microtek 3kva me 3kw watt penal lga sakte hai or 5kva me 5kw penal lga sakte hai jo maximum seema hai to kya esme 300 watt ya 400 watt penal over lga sakte hai kya please batao 🙏❤️🌹
At your own risk.
Sir , Apne jo 320 watt ka pannel use kar rahe ho uska Voc & Vmp kitna hai....??
I'll share sticker when I go near.
Utl gamma plus inverter hai 200ah battery laga hai kya aur 150ah ka battery jod sakte hai ya 200ah ka dono battery hona chahiye
th-cam.com/video/zVMnJFe0vDs/w-d-xo.html
Invarter me peeche ki taraf ek red colour ka blaf laga hai
Wo blaf sahi canection karne pe jalta hai ya glat pe
Reverse wire pe jalega.
Sir 33% load puri rat chal jata hai is battery bank se
सर।ईन्वर्टर के आउटपुट वायर पर स्टेबलाइजर लगाने से क्या होगा?क्या ऐसा कर सकते हैं?
Not recommended
Nice
Thanks RC
Sar may gama pals invrtar 6*4150=900wat penal. Betriy setup 150ah+75ah=225ah... betriy cage amp kitne rakhe ................................. over penal 200wat charge controller liuminas 10amp
225 AH means 22 ya 23A le sakta ha. If one charge controller is 10A, other should be set at 13A
More details here-
th-cam.com/video/1RMkdRQ1vg4/w-d-xo.html
Sir mere pass JA solar panel 455w ka hai jo ki 48v de raha hai... To sir mein es pr 12v ka inverter or battery ksise chalaye...???
You'll need an MPPT with good VOC support, Like this one-
(12V/24V : 40Amps : Max.Voc - 95V) amzn.to/3J4gC2Y
(12/24/36/48V: 80Amp, Voc:210V) amzn.to/374S6BH
(12/24/36/48V : 80Amps :Max.Voc - 165V) amzn.to/3K9OQnd
Sir 400 watt ke 2 pannel + 330 ka 1 pannel laga sakte he 1000 va machine me
Check QNA EP 6 & 18
Hello sir utl gamma plus pe whipool 215L refrigerator chalake dikha ye
Dear Subscriber, Its nice that you want me to Test & compare various Products. However, I cannot keep buying all the products. Hence what you can do is to tweet these companies to send me a review sample.
Bhai may month ke load testing video banao
This time I cannot Brother.
👍👍 good info
Thanks 👍
Pannel to Investor tak kitnay mm wire use kiya ... Ac H ya Dc wire
Kindly Reply..
12mm
Sir kaya 2000va gumma plus main 1600w panel lagba saktay??
th-cam.com/video/ThpBQb5RyCM/w-d-xo.html
Sir why connection of solar plate in parallel? Plz tell me
depends on your needs & VOC.
Bro, i have a doubt. I have 75w panel while testing in multimeter its shows 20v x 3.4A (short circuit current). But while connected with UTL GAMMA PLUS it's shows 14V x 2.8 Ampere current. Whats actually happening here?
Try again with better sun angles. Some variation between advertised & real values is present as explained in solar QNA ep 18.
Its also possible it has a bad diodes.
@@ZenInnovations while checking amp with short circuit it's shows 3.4 amp and while connected my multimeter with series its shows 2.8 amps. I've checked with both pwm controller and utl gamma plus.
@@ramanathansrinivasan2524 because there's difference between ISC & IMP.
VOC & VMP.
Its also mentioned on panel sticker.
Sir, हमें य़ह बताएं कि मेरा 370 watt का 2 पैनल है और मैं इसपर 330 watt का एक और पैनल लगाना चाहता हूं क्या ठीक रहेगा
Yes, if VOC is same.
Sir 1kv solar produce 4 unit electricity. Then why ur setup produce 2.5. mppt inverter make 5 or 6 unit???
Depends on the load.
Production depends on the load.
Sour palet lagane par invarter me me jo baitri walA box bana hai ushame uper se neeche ki taraf aata hai aisha kyo ishki jaankari chahiye
Query unclear.
Sir ye fuse se solar voltage par fark to nhi padta
No Losses in Fuse Observed.
jada penal lagane se kuch problem to nahi hota hai na❤️❤️❤️❤️
Watch the video carefully...
Sir mere paas ek Vikram solar ka panel lga h jiska voc 49.4 h electrower ka solar pcu h jab chata hai to uska volt kav 20 25 30 37 btata kya mera panel kharab h please reply me
Maybe Joint or connector is not good.
@@ZenInnovations sir voltage aa rha hai but inverter on karne ke baad doun ho ja raha hai
Maybe you have PWM inverter.
@@ZenInnovations sir mere paas Electrower ka mppt best h
@@mdjlaluddin1355 Ok. Join my Telegram group for detailed Discussion.
Bhai mujha pcu lana cheye ya fir solar inverter
This was discussed long ago in QNA EP 1 & 2.
Mane utl gamma + liya hai aur us se 300 ltr Ka chest freezer Nahi chal raha hai please help sir
Fridge discussion here-
th-cam.com/video/X5-3Xs_eghY/w-d-xo.html
Dude ru promoter of UTL Gamma plus?
No. But I am an Avid Promoter of Green Energy.
जेन जी ये बताएं कि आपके 1.3kw पैनल्स से पूरी धूप पर मैक्सिमम कितने वाट्स का लोड चल जाता है?
700 to 800w.
@@ZenInnovations मैंने rehub 40A का सोलर चार्ज कंट्रोलर एवं 1200वाट्स के पैनल लगाए हैं 24v बैटरी है।peak output 700-800 वाट्स ही मिलता है।
@@ashokkumardubey2524 sahi hai.
If you are using mppt than you will get around 90-95% output but if you are using PWM then you will get only 65-70%. This is my personal experience.
@@vdagar7352 Yes, thats a given.
Your Solar plate voltage?
45v
@@ZenInnovations tell rated voltage not VOC. Which comes as 12v, 24v, 48v
What you are saying is known as nominal system voltage. and its a senseless standard.
24v for you.
165watt ke 5 panel 12v chal sakta hai 220ah 12 battery
yes.
Aapko steplizer lagne ki jarurat ni hi utl gamma me 290 v se uper jate hi protection mode me aa jata hi or it mode me 260 se uper jate hi protection on ho jata hi , same low voltge me bhi hota hi ,age apke yha grid voltge kam aate hi to stabilizer lagana sahi hi verna koi fayda ni hi
Stabilizer is good for Running sensitive equipments.
0.5 hp motor chalti hai ya nahi
For Running motor-
th-cam.com/video/hUtVfS9g0yk/w-d-xo.html
It is not possible a front loading washing machine run on 1 kw pcu.
th-cam.com/video/-kTYyBdBV5s/w-d-xo.html
th-cam.com/video/bs1Yp1X0bUc/w-d-xo.html
Utl gama 12volt ka voc kitna? 15-45 or 32-90?
15 to 49.5 In latest model.
@@ZenInnovations inverter की guide copy मे voc 15-45, 30-90 लिखा हुआ है 30_90 क्या अर्थ हुआ
मुझे लगता है कि अगर मीटर से रीडिंग लेंगे तो ये ज्यादा यूनिट होंगे क्योंकि बैटरी से जो चलता है वो तो इस रीडिंग में नहीं आएगा
Battery charge bhi solar se hoga, to uska reading aa jayega apne aap.
Sir 320 watt k 4 panel gamma plus pr 12v setup pr koi Problem nhi aye apko
Personally no. Mast chal raha hai.
@@ZenInnovations Hello sir, I have seen almost all of your UTL Gamma+ videos and go for the same setup, I have installed three UTL 400W mono panels (total 1200W) and 12V UTL Gamma Plus inverter . My panels are around 33 meters away from inverter and are connected with Polycab 4mm dc cable and tilt at an angle of 30-31 degrees Chandigarh , peak generation till date ( may-June 2022) is 30V X 21A = 610W , but you have mentioned your peak generation is around 900W, So should I upgrade dc wire to get full potential of solar panels or are there some other factors which you would suggest . Also I have one other question , the 12V gamma Plus has 40A charge controller so how does it supports 1000W panels as 40A X 12V = 480W is the maximum solar output which we can get from it.
@@grewal630 pls upgrade to 10mm wire also watch QNA ep 18.
@@ZenInnovations Should I change wires to 10mm or add new 6mm positive as well as negative wires to existing 4mm wires.
@@grewal630 you can add 6mm but joints need to be very properly. Soldering recommended.
यूटीएल गम्मा पुलिस खरीदना चाहिए या नही
th-cam.com/video/pleFXQMESpA/w-d-xo.html
Hello 👋 sir good morning
Hi
@@ZenInnovations reply my 2 Question sir
@@gursharansingh2911 sure. When I'm on Laptop.
@@ZenInnovations sir mane morning me app se pusha tha k Kea hum kese vi mara Matlab mppt ja pwm solar inverter pe panal laga kar sath me ambrroot rehub pe vi panel laga sakte h ja ne
You can use but battery Bank must be huge.
Mera refrigerator nahi chal raha gamma ➕
th-cam.com/video/X5-3Xs_eghY/w-d-xo.html
इसपे हाप hp पानी पम्प चलेगा
for 0.5HP Pump watch this-
th-cam.com/video/hUtVfS9g0yk/w-d-xo.html
Sir mai ek dukandar hu mujhe utl chager or charger card display lena hai up lakhimpur kheri distributor ka number dedo sir
Bro I am not a dealer. You can buy UTL product online here-
amzn.to/3qKnwBq
bhai tune picha ka back nhi dikhaya ji 12 volt ka hai back penal dikhna tha bakwaas krne se yakin nhi hota dikhna bhi hota hai upar se 2 battery use kra
Those who don't trust me can leave the video.
bhai ham to aankhon dekhi pe bahrosha karta hai tb naa k insaan pe
Bahut ghatiya generation hai 1.3kw panel se it should be around 150 units
.
Sir mera charge controller 10amp Ka Hai To Kya Isme 200 watt ka solar panel Laga sakte hain
Maximum panel wattage is mentioned on controller or user manual.
165watt
@@pushpendrayadav185 don't use
Sir, UTL GAMMA + kitna surge load utha sakta hai, pls reply
About 800 to 1000w