"Watch how this incredible HVAC technician TAMES a noisy AC unit like a boss

แชร์
ฝัง

ความคิดเห็น • 65

  • @thebaba9511
    @thebaba9511 3 ปีที่แล้ว +16

    I learn a lot from the these videos man, I appreciate the work you do putting these out to help us technicians get better at what we do. Nothing but love from me man 👍 please keep these coming!

  • @carlwheeler3403
    @carlwheeler3403 3 ปีที่แล้ว +5

    I started maintaining my R22 AC units (3&5 ton) myself about 10 years ago because some knucklehead overcharged my 3 ton unit ( and charged me for it). With the exception of a fan motor going out, my units have been running flawlessly for 10 years. I spent about $2K on equipment but I have saved 3 times that much by doing it myself. I knew nothing about AC 10 years ago but I'm very knowledgeable now.

  • @Channel-cm7yc
    @Channel-cm7yc 3 ปีที่แล้ว +5

    Bet they noticed a big difference in cooling performance. I remember back in my helper days they would always say it was cooling good and you look at the numbers and listen to it grinding itself to death and go that’s not even possible lol lol..
    Glad to see all of yah making videos are workin’ out there!!

  • @JosephGetchel
    @JosephGetchel 3 ปีที่แล้ว +2

    Nothing like having a bit of room around the condenser unit to be able to work on it! 8>)

  • @andycensus
    @andycensus 3 ปีที่แล้ว +1

    Good video, hard to believe how small the lots are in Texas (as big as Texas is) makes it tough working around the units

  • @agostinodibella9939
    @agostinodibella9939 3 ปีที่แล้ว +3

    It’s funny how first impressions can be deceiving making you think the fan motor was bad! Your careful, professional method of trouble shooting revealed the true problem of the bad compressor.

    • @JP-zz5rm
      @JP-zz5rm 3 ปีที่แล้ว

      True that!

  • @Straycurrent
    @Straycurrent 3 ปีที่แล้ว

    That condensing unit had done its duty. Nice video - thanks for brings us along.

  • @travisewing1795
    @travisewing1795 3 ปีที่แล้ว

    I dig this dudes video. Keep it up! I’m over here near Galveston, so your vids are hitting close to home

  • @carlwheeler3403
    @carlwheeler3403 3 ปีที่แล้ว +3

    It looked way overcharged to me, the compressor was making noise because it was being slugged by to much liquid. Meter readings should have been 70 by 190. Did you check the SH and SC, that would have been a dead give away. Looks like someone charged it to 410 pressure specs.

  • @treylyde999
    @treylyde999 ปีที่แล้ว

    I like that tile

  • @jo6520
    @jo6520 3 ปีที่แล้ว

    Good work you can't save them all. It would be to expensive to replace the compressor. Have a good day and stay cool

  • @charlesjones290
    @charlesjones290 3 ปีที่แล้ว +3

    With a R22 system change of condenser the pressures are higher aren't you worried about the difference in pressures on the evaporator coil and you converted from a txv to a piston drivin ? Thats chancing a rupture don't you think?

    • @drodriguez394
      @drodriguez394 3 ปีที่แล้ว

      Incorrect. A lot of newer R22 evap a were rated “R22 or 410a” then it said to confirm at condenser l.

    • @texasoutlaw210
      @texasoutlaw210 3 ปีที่แล้ว +2

      I’m thinking the air handler was replaced with a 410 coil and r22 txv so all he had to do was change the condenser and replace metering device.

  • @Eddy63
    @Eddy63 3 ปีที่แล้ว

    Staying busy ... Stay safe out there ...

  • @BIGBOB-ew9oo
    @BIGBOB-ew9oo 3 ปีที่แล้ว +3

    As soon as you pulled up. I knew the brand and that the compressor was making that noise. That compressor will lock up.

  • @HNIC86
    @HNIC86 3 ปีที่แล้ว +2

    Man here in Fayetteville NC we reached 97 degrees heat index 106 high humidity.

    • @staycoolwithrob
      @staycoolwithrob 3 ปีที่แล้ว +1

      IM in charlotte i already know

    • @HNIC86
      @HNIC86 3 ปีที่แล้ว

      @@staycoolwithrob yeah man this heat is getting dangerous but we do got some cool days ahead.

  • @HNIC86
    @HNIC86 3 ปีที่แล้ว

    Make them big dollars dawg. Ayeeee great call great roll call. New unit

  • @enormity8797
    @enormity8797 3 ปีที่แล้ว

    I would've used a txv and I hoped he flush the lines. Those pressures and sound I thought maybe overcharged

  • @texasmade2684
    @texasmade2684 3 ปีที่แล้ว +1

    You try to discharge the capacitor with your drill I wonder if the capacitor has a charge one day itll burn up your drill

  • @HNIC86
    @HNIC86 3 ปีที่แล้ว +2

    Yeah that compressor is giving out. On it's last leg.

  • @Dadoftwins48
    @Dadoftwins48 3 ปีที่แล้ว +1

    Cut the resistor on that hard start and test it again.

  • @victorblackwood3727
    @victorblackwood3727 3 ปีที่แล้ว

    You can not get a true reading on the capacitor till you cut the diode off one side. Then you can tell if it is good or bad. If it is good put a clip on diode on it. You get clip on diode at HVAC supply house.

  • @richielittlewood867
    @richielittlewood867 2 หลายเดือนก่อน

    You forgot to see if the unit is level on its base .every part you put on it was rolling off towards you ????

  • @jameslandrey1130
    @jameslandrey1130 3 ปีที่แล้ว

    Why did you go from a txv valve to a piston and how do you figure it’s more efficient?

    • @caru3257
      @caru3257 3 ปีที่แล้ว

      he can't figured out that is more efficient. It is like going from an inverter compressor to a scroll or reciprocating compressor.

    • @ronniebuchanan6575
      @ronniebuchanan6575 3 ปีที่แล้ว

      Pistons are much easier to deal with TXV suppose to make it 1/2 SEER higher.

  • @jinjrhaynes
    @jinjrhaynes 3 ปีที่แล้ว +2

    Don't you have to give the system time to equalize before starting back up?

  • @alannewsome1729
    @alannewsome1729 3 ปีที่แล้ว +1

    Damn how many cats did they have? Lol!

  • @neatfixhvacr4195
    @neatfixhvacr4195 3 ปีที่แล้ว +1

    You are awesome bro keep it up

  • @ehtishamjutt4162
    @ehtishamjutt4162 3 ปีที่แล้ว

    Bro me work also your work is very good 🧐

  • @andyhernandez1048
    @andyhernandez1048 3 ปีที่แล้ว

    You the man , good job.

  • @arcticarrowhvacr
    @arcticarrowhvacr 3 ปีที่แล้ว

    Man that compressor's angry!

  • @realestateservicessaleshea99
    @realestateservicessaleshea99 3 ปีที่แล้ว

    Keep um come'n !! 👍🏻
    🥃🥃🍺🍺🍺🍇🎳
    Stay safe.
    Retired (werk'n)keyboard super tech. Wear your safety glasses.

  • @blackericdenice
    @blackericdenice 3 ปีที่แล้ว

    3:30 I thought when you hear a hum. The contact was bad.

    • @mattthomas1217
      @mattthomas1217 3 ปีที่แล้ว

      If the contactor is humming then should have to ohm out the coil to see if it is bad. But some will hum and they will still be ok.

    • @tkgotwings_6401
      @tkgotwings_6401 3 ปีที่แล้ว

      the good ole death buzz

  • @Matts_Crafty
    @Matts_Crafty 3 ปีที่แล้ว +1

    Reeds are shot in compressor def on it way to the bone yard! I see the cart is doing its job money well spent ... Nice video Walt.

    • @stephenbierlein2517
      @stephenbierlein2517 3 ปีที่แล้ว +2

      True I would have done pump down test to find condition of valves.

    • @stephenbierlein2517
      @stephenbierlein2517 3 ปีที่แล้ว +2

      Pump down test first.

    • @Matts_Crafty
      @Matts_Crafty 3 ปีที่แล้ว

      @@stephenbierlein2517 I just look at the gauges / amps and listen to it, def leaking back to suction side.

    • @andyhernandez1048
      @andyhernandez1048 3 ปีที่แล้ว

      Reeds? On an 06E those can be changed out
      Not on that residential compressor.

    • @stephenbierlein2517
      @stephenbierlein2517 3 ปีที่แล้ว

      The last I knew valve plates changed in cast iron compressors. Pump down only sure way when valves don't seem right. The readings were very marginal.

  • @theduffster2581
    @theduffster2581 3 ปีที่แล้ว

    Gotta change out that evap coil bud that’s half assed work 😱

    • @juelzd7172
      @juelzd7172 3 ปีที่แล้ว +1

      Customer probably just wanted to get condenser replaced instead but whole new unit

    • @theduffster2581
      @theduffster2581 3 ปีที่แล้ว

      @@juelzd7172 still not the right way how much more was an evap coil ? just a way to make a quick buck I guess I’ve never done that 😱

    • @andrewwelch5668
      @andrewwelch5668 3 ปีที่แล้ว +2

      @@theduffster2581 Easy for other techs to say that all of the equipment needs to be changed out sitting from an armchair perspective instead of being on the same job this guy was on. If the customer ain't paying for it, would you do it? Sometimes they want the bare minimum to get them back up and running again because they don't have the funds to "do it the right way". This guy is trying all he can to help the homeowner(s) out on a budget. He shouldn't be shamed for doing all he can without breaking the bank.

    • @theduffster2581
      @theduffster2581 3 ปีที่แล้ว +2

      @@andrewwelch5668 it’s still not the right way in my opinion an old r22 coil will not hold up I’ve been doing hvac work in Chicago for 30 plus years and I don’t do the quick fix plus the price of a new coil wouldn’t be that much more and it would be done the proper way and no I’m not on my couch lol just have seen a lot of failures with that procedure I guess that’s just me 👍🏻 keep hydrated and be safe 👍🏻

    • @realsthvac7942
      @realsthvac7942 3 ปีที่แล้ว

      Here its code if you replace compressor bearing equipment all must be changed can use existing lines set if so choose.

  • @ShyRage1
    @ShyRage1 2 ปีที่แล้ว

    both cmpressors sounded the same

  • @lancelawrence3259
    @lancelawrence3259 3 ปีที่แล้ว

    Nice work

  • @stephwaylonwells3218
    @stephwaylonwells3218 3 ปีที่แล้ว

    👍

  • @realsthvac7942
    @realsthvac7942 3 ปีที่แล้ว +2

    You should of ohm out the compressor winding since you had the fan out

  • @dontarguewithfools
    @dontarguewithfools 3 ปีที่แล้ว

    On video sounds like it's overcharged

  • @rickys2674
    @rickys2674 3 ปีที่แล้ว

    I’ve had that happen when power cuts on and off rapidly
    Compressor sounds like the polarity is switched on a 3 phase system
    If you let it run to long that way compressor will fail
    If you hear this turn system off for a few minutes but most homeowners will just let it run that way

    • @Chris2745100
      @Chris2745100 3 ปีที่แล้ว +1

      I would cut the breakers to the HVAC units if a bad electrical storm was coming. Just one close lightning strike on a nearby utility pole could put you out 10,000-20,000$ I have had it to where my condenser would not start for a few hours after a nearby lightning strike on a pole. Probably a electrical board got a little juiced if you know what I mean. I got lucky there as there were no performance issues afterwards.

  • @stephenbierlein2517
    @stephenbierlein2517 3 ปีที่แล้ว

    In most cases relay causes capacitor to go bad. I would have tried to add a little oil to compressor .

  • @jrod3515
    @jrod3515 3 ปีที่แล้ว

    You might need to get a helper